Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DEAD TIME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dead-time Corrected Disdrometer Data

Original and dead-time corrected disdrometer results for observations made at SGP and TWP. The correction is based on the technique discussed in Sheppard and Joe, 1994. In addition, these files contain calculated radar reflectivity factor, mean Doppler velocity and attenuation for every measurement for both the original and dead-time corrected data at the following wavelengths: 0.316, 0.856, 3.2, 5, and 10cm (W,K,X,C,S bands). Pavlos Kollias provided the code to do these calculations.

54 ENVIRONMENTAL SCIENCES↗

SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60 gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.

07 ISOTOPE AND RADIATION SOURCES↗

On the Time Interval Distribution Between Neutron Counts in a 3 He Proportional Counter with Detector Dead Time

For materials where a spontaneously fissioning isotope (e.g. 238 U or 240 Pu) initiates fission chains which propagate within a quantity of fissile material (e.g. 235 U or 239 Pu), the neutrons are not generated according to a Poisson process because a single random event | the spontaneous fission of a radioactive nucleus | can generate many neutrons. We propose a perturbative theory to correct the time interval distribution between neutron counts for materials that spontaneously generate fission chains to accommodate the detector dead time inherent in 3 He proportional counters. We also propose a perturbative correction for multi-element detectors where the dead time applies only to neutrons counted within a single element.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Theory of particle detection and multiplicity counting with dead time effects

The subject of this paper is the investigation of the effect of the dead time on the statistics of the particle detection process. A theoretical treatment is provided with the application of the methods of renewal theory. The detector efficiency and various types of the dead time are accounted for. Exact analytical results are derived for the probability distribution functions, the expectations and the variances of the number of detected particles. Explicit solutions are given for a few representative cases. The results should serve for the evaluation of the measurements in view of the dead time correction effects for the higher moments of the detector counts. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Live-timer method of automatic dead-time correction for precision counting

Automatic correction for dead time losses in nuclear counting experiments is implemented by a simple live timer arrangement in which each counting interval is extended for compensation for the dead time during that interval. this method eliminates repetitious manual calculations, source of error, and dependence upon paralysis shifts.

Porges, K. G.↗

The Feynman-Y Statistic in Relation to Shift-Register Neutron Coincidence Counting: Precision and Dead Time

The Feynman-Y statistic is a type of autocorrelation analysis. It is defined as the excess variance-to-mean ratio, Y = VMR - 1, of the number count distribution formed by sampling a pulse train using a series of non-overlapping gates. It is a measure of the degree of correlation present on the pulse train with Y = 0 for Poisson data. In the context of neutron coincidence counting we show that the same information can be obtained from the accidentals histogram acquired using the multiplicity shift-register method, which is currently the common autocorrelation technique applied in nuclear safeguards. In the case of multiplicity shift register analysis however, overlapping gates, either triggered by the incoming pulse stream or by a periodic clock, are used. The overlap introduces additional covariance but does not alter the expectation values. In this paper we discuss, for a particular data set, the relative merit of the Feynman and shift-register methods in terms of both precision and dead time correction. Traditionally the Feynman approach is applied with a relatively long gate width compared to the dieaway time. The main reason for this is so that the gate utilization factor can be taken as unity rather than being treated as a system parameter to be determined at characterization/calibration. But because the random trigger interval gate utilization factor is slow to saturate this procedure requires a gate width many times the effective 1/e dieaway time. In the traditional approach this limits the number of gates that can be fitted into a given assay duration. We empirically show that much shorter gates, similar in width to those used in traditional shift register analysis can be used. Because the way in which the correlated information present on the pulse train is extracted is different for the moments based method of Feynman and the various shift register based approaches, the dead time losses are manifested differently for these two approaches. The resulting estimates for the dead time corrected first and second order reduced factorial moments should be independent of the method however and this allows the respective dead time formalism to be checked. We discuss how to make dead time corrections in both the shift register and the Feynman approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Innovative dead-time correction and background subtraction for neutron multiplicity measurements using neural networks

Abstract The number of neutrons emitted from a nuclear reaction plays a crucial role in various fields, including nuclear theory, nuclear nonproliferation, nuclear energy and nuclear criticality safety. Accurate determination of neutron multiplicities requires the application of several corrections, with dead-time correction and background subtraction being particularly significant. These corrections become more challenging for neutron detectors with time-dependent neutron capture. In this work, we perform a comprehensive study of three existing methods used for dead-time correction and background subtraction in neutron detectors with time-dependent neutron capture. The methods were tested for dead-times in the range from 0 to 1 μs using a Monte Carlo model simulating the dead-time and background effects in the standard neutron multiplicity probability distribution of $$^{252}$$ 252 Cf. The previous methods showed larger than desired uncertainty or systematic trade off. Those uncertainties prompted the development of a novel approach using neural networks trained with data from Monte Carlo simulations. The Neural Network method enabled the correction of neutron multiplicity probabilities more accurately than the other methods with fractional errors smaller than 3% for multiplicities around the peak of $$^{252}$$ 252 Cf. A similar approach using neural networks could be applied to problems where the system being studied can be accurately simulated without having an accurate analytical description available. The neural network method presented in this paper can be easily expanded if multiplicities greater than 10 are expected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dead-Time Correction of Pulsed Neutron Source Experiments with the Backward Extrapolation Method

This paper introduces a novel procedure to correct pulsed neutron source experimental data for dead-time effects. The procedure is based on the application of the backward extrapolation method to the reaction rate value in each time interval (bin) of the neutron counts distribution as a function of time. The theoretical framework has been successfully applied to the experimental data (timestamps) from the YALINA Thermal facility driven by a pulsed D-D neutron source. Dead-time effects may have more than 500 pcm (1 pcm=1 E-5) impact on the effective multiplication factor calculated by the area method. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Extension of the Dytlewski-style dead time correction formalism for neutron multiplicity counting to any order

Here, neutron multiplicity counting using shift-register calculus is an established technique in the science of international nuclear safeguards for the identification, verification, and assay of special nuclear materials. Typically passive counting is used for Pu and mixed Pu-U items and active methods are used for U materials. Three measured counting rates, singles, doubles and triples are measured and, in combination with a simple analytical point-model, are used to calculate characteristics of the measurement item in terms of known detector and nuclear parameters. However, the measurement problem usually involves more than three quantities of interest, but even in cases where the next higher order count rate, quads, is statistically viable, it is not quantitatively applied because corrections for dead time losses are currently not available in the predominant analysis paradigm. In this work we overcome this limitation by extending the commonly used dead time correction method, developed by Dytlewski, to quads. We also give results for pents, which may be of interest for certain special investigations. Extension to still higher orders, may be accomplished by inspection based on the sequence presented. We discuss the foundations of the Dytlewski method, give limiting cases, and highlight the opportunities and implications that these new results expose. In particular there exist a number of ways in which the new results may be combined with other approaches to extract the correlated rates, and this leads to various practical implementations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dead-time effects in microchannel-plate imaging detectors

The observed counting rates of microchannel plate (MCP) based detectors for high resolution observations of celestial EUV and X-ray sources vary over many orders of magnitude; the counting capability of an individual channel, however, is not high, and is associated with dead-times ranging from 0.1 msec to 1 sec. The dead-time increases with the area illuminated; attention is presently given to laboratory determinations of the count rate characteristics of a MCP detector as a function of illuminated area, and a model is developed for these results' use in the interpretation of space observations.

Zombeck, Martin V.↗

A Sensorless Coil Detection Scheme based on Dead-Time Effect in Dynamic Wireless Power Transfer Systems

The detection of electric vehicles in dynamic wireless power transfer (DWPT) systems is important to reduce the standby losses and comply with the electromagnetic-field emission guidelines recommended by the International Commission for Non-Ionizing Radiation Protection. This paper discusses a novel sensorless coil detection scheme, which exploits the phenomenon of voltage-polarity reversal/notches caused by the dead-time effect in the full-bridge inverter. The variations in the system impedance and dead-time effects are collectively exploited to detect the receiver coil in the DWPT system. The proposed coil detection scheme is accomplished at low excitation voltage, which reduces the inverter standby losses. The theoretical analysis of the notch occurrence and open-loop simulation results are presented using a DWPT model developed in the piecewise linear electrical circuit simulation software.

Kavimandan, Utkarsh↗

Online condition monitoring based dead-time compensation for high frequency SiC voltage source inverter

Dead-time, device output capacitance, and other non-ideal characteristics cause voltage error for the midpoint PWM voltage of the semiconductor phase-leg employed in a voltage-source inverter (VSI). Voltage-second balancing is a well-known concept to mitigate this distortion and improve converter power quality. This paper proposes a unique voltage-second balancing scheme for a SiC based voltage source inverter using online condition monitoring of turn-off delay time and drain-source voltage rise/fall time. This data is sent to the micro-controller to be used in an algorithm to actively adjust the duty cycle of the input PWM gate signals to match the voltage-second of the non-ideal output voltage with an ideal output voltage-second. The monitoring system also allows for this implementation to eliminate the need for precise current sensing and allows for the implementation to be load independent. Dynamic current sensing is still a developing technology, and each load has a unique effect on the output voltage distortion. Test results for a 1 kW half-bridge inverter implementing this monitoring system and voltage-second balancing scheme show a 70% enhancement on the error against the ideal fundamental current value of the output current and a 2% THD improvement on the output current low frequency harmonics.

Dyer, Jacob↗

Report on Task USA A 0931 (A.252) Implementation of Fast, Front-End Electronics for Improved Low-Dead Time Neutron Counting

The International Atomic Energy Agency's (IAEA) Department of Safeguards is working on the elaboration and implementation of advanced Non-Destructive Assay (NDA) methods, generally known as neutron noise analysis, for the verification of critical and sub-critical cores containing substantial quantities of direct use nuclear material. These verification methods rely on interpreting time properties of the neutron multiplication process, which are to be extracted from measured neutron pulse trains. The interpretations are highly dependent on the quality of the measured data, which is directly related to the capability of an employed neutron detector to resolve very close detection events originating from neutron bursts produced in a highly multiplying medium. Therefore, the application of detectors with minimum dead-time, pile-up, and other distortion effects is required. This report describes the work under Task USA A 0931 (A.252 Implementation of fast, front-end electronics for improved low-dead time neutron counting).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗