Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Co”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ames-2021 CO 2 Dipole Moment Surface and IR Line Lists: Toward 0.1% Uncertainty for CO 2 IR Intensities

A highly accurate CO 2 ab initio dipole moment surface (DMS), Ames-2021, is reported along with 12 C 16 O 2 infrared (IR) intensity comparisons approaching a 1–4‰ level of agreement and uncertainty. The Ames-2021 DMS was accurately fitted from CCSD(T) finite-field dipoles computed with the aug-cc-pVXZ (X = T, Q, 5) basis for C atom and the d-aug-cc-pVXZ (X = T, Q, 5) basis for O atoms, and extrapolated to the one particle basis set limit. Fitting σ(rms) is 3.8 × 10^(–7) au for 4443 geometries below 15 000 per cm . The corresponding IR intensity, S Ames-2021 , are computed using the Ames-2 potential energy surface (PES), which is the best PES available for CO 2 . Compared to high accuracy IR studies for 2001i–00001 and 3001i–00001 bands, S Ames-2021 matches NIST experiment-based intensities [S NIST-HIT16 or S HIT20 ] to −1.0 ± 1.3‰, or matches DLR experiment-based intensities [S DLR-HIT16/UCL/Ames ] to 1.9 ± 3.7‰. This indicates the systematic deviations and uncertainties have been significantly reduced in S Ames-2021 . The S UCL2015 (or S HITRAN2016 ) have larger deviations (vs S DLR ) and uncertainties (vs S DLR , S NIST ) which are attributed to the less accurate Ames-1 PES adopted in UCL-296 line list calculation. The S Ames-2021 intensity of 12 C 16 O 2 and 13 C 16 O 2 is utilized to derive new absolute 13 C/ 12 C ratios for Vienna PeeDee Belemnite (VPDB) with uncertainty reduced by 1/3 or 2/3. Further evaluation of S Ames-2021 are carried out on those CO 2 bands discussed in the HITRAN2020 update paper. Consistent improvements and better accuracies are found in band-by-band analysis, except for those bands strongly affected by Coriolis couplings, or very weak bands measured with relatively larger experimental uncertainties. The Ames-2021 296 K IR line lists are generated for 13 CO 2 isotopologues, with 18,000 per and S 296K > 1E–31) cm/molecule cutoff and then combined with CDSD line positions (except 14 C 16 O 2 ). The Ames-2021 DMS and 296 K IR line lists represent a major improvement over previous CO 2 theoretical IR intensity studies, including Ames-2016, UCL-296, and recent UCL DMS 2021 update. A real 1 permille level of agreement and uncertainty will definitely require both more accurate PES and more accurate DMS.

Chemical calculations↗

29P/Schwassmann–Wachmann 1: A Rosetta Stone for Amorphous Water Ice and CO↔CO 2 Conversion in Centaurs and Comets?

Centaur 29P/Schwassmann–Wachmann 1 (SW1) is a highly active object orbiting in the transitional "Gateway" region between the Centaur and Jupiter-family comet (JFC) regions. SW1 is unique among the Centaurs in that it experiences quasi-regular major outbursts and produces CO emission continuously; however, the source of the CO is unclear. We argue that, due to its very large size (∼32 km radius), SW1 is likely still responding, via amorphous water ice (AWI) conversion to crystalline water ice (CWI), to the "sudden" change in its external thermal environment produced by its Myrs-long dynamical migration from the Kuiper Belt to its current location at the inner edge of the Centaur region. It is this conversion process that is the source of the abundant CO and dust released from the object during its quiescent and outburst phases. If correct, these arguments have a number of important predictions testable via remote sensing and in situ spacecraft characterization, including the quick release on Myr timescales of CO from AWI conversion for any few kilometer-scale scattered disk Kuiper Belt Objects transiting into the inner system; that to date SW1 has only converted between 50% and 65% of its nuclear AWI to CWI; that volume changes on AWI conversion could have caused subsidence and cave-ins, but not significant mass wasting or crater loss; that SW1's coma should contain abundant amounts of CWI+CO 2 "dust" particles; and that when SW1 transits into the inner system within the next 10,000 yr, it will be a very different kind of JFC.

Centaur 29P/Schwassmann–Wachmann 1(SW1)↗

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell↗

CO-oxidation catalysts: Low-temperature CO oxidation over Noble-Metal Reducible Oxide (NMRO) catalysts

Oxidation of CO to CO2 is an important reaction technologically and environmentally and a complex and interesting reaction scientifically. In most cases, the reaction is carried out in order to remove CO as an environmental hazard. A major application of heterogeneous catalysts is catalytic oxidation of CO in the exhaust of combustion devices. The reaction over catalysts in exhaust gas is fast and often mass-transfer-limited since exhaust gases are hot and O2/CO ratios are high. The main challenges to catalyst designers are to control thermal sintering and chemical poisoning of the active materials. The effect of the noble metal on the oxide is discussed, followed by the effect of the oxide on the noble metal, the interaction of the noble metal and oxide to form unique catalytic sites, and the possible ways in which the CO oxidation reaction is catalyzed by the NMRO materials.

Herz, Richard K.↗

Electron-temperature dependence of dissociative recombination of electrons with CO(+)-(CO)n-series ions

A microwave afterglow mass spectrometer apparatus is used to determine the dependence on electron temperature T sub e of the recombination coefficients alpha sub n of the dimer and trimer ions of the series CO+.(CO) sub n. It is found that alpha sub 1 = (1.3 + or - 0.3)x 0.000001 (T sub e(K)/300) to the -0.34; and alpha sub 2 = (1.9 + or - 0.4)x 0.000001 (T sub e(K)/300) to the -0.33 cu cm/sec. These dependences on T sub e are quite different from those obtained previously for polar-cluster ions of the hydronium and ammonium series but are similar to that for simple diatomic ions.

Whitaker, M.↗

Electrospraying and Electrospinning of Polymers for Biomedical Applications. Poly(Lactic-Co-Glycolic Acid) and Poly(Ethylene-Co-Vinylacetate)

Significant opportunities exist for the processing of polymers (homopolymers and blends) using electric fields. Specific attention is given here to electrospinning, but we note that electroaerosol formation and field-modulated film casting represent additional processing options. Of particular interest is the ability to generate polymer fibers of sub-micron dimensions using electrospinning, down to about 0.05 microns (50 nm), a size range that has been traditionally difficult to access. In our work, poly(lactic-co-glycolic acid), PLA/PGA, poly(lactic acid) PLA, and poly(ethylene-co-vinylacetate) (PEVA) have been deposited from solutions in methylene chloride or chloroform by electrospraying or electrospinning to afford morphologically tailored materials for tissue engineering and related applications. Low solution concentrations tend to favor electrostatic spraying ('electro-aerosolization') while higher concentrations lead to spinning on fibrous mats. Preliminary observations of muscle cell growth on PLA electrospun mats are reported.

Stitzel, Joel D.↗