Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bidirectional Charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Introduction of a Variable Inductance Transformer for the Design of Resonant Power Converters

Magnetic integration is a hot topic in power electronics that concerns the use of a transformer’s leakage and magnetizing inductances purposefully in isolated power electronic converters, thereby giving the opportunity to save the cost and footprint of any additional inductor. This is of prime interest, especially in CLLLC resonant converters which require up to three inductors. For a complete integration of these inductances, the concept of a variable inductance transformer (VIT) is introduced in this thesis. A VIT is an adaptive magnetic structure that facilitates an easy adjustment of both magnetizing and leakage inductances to meet their desired values. However, for a more promising design, an accurate estimation of these inductances is necessary. While the evaluation of magnetizing inductance is quite straightforward, the calculation of leakage inductance is rather convoluted, because the leakage inductance is influenced by both the winding layout and the operating frequency. In this thesis, three new semi-analytical methods for calculating the frequency-independent leakage inductance, and a novel semi-analytical method for evaluating the frequency-dependent leakage inductance are proposed. These methods can calculate the respective leakage inductances of a VIT within an outstanding ±5% uncertainty. Finally, a bidirectional CLLLC resonant dc-dc converter is investigated for the constant current constant voltage (CCCV) charging of the next-generation 900 V traction battery of an electric vehicle. A new voltage gain equation is derived for designing the CLLLC resonant tank, and a small-signal model is presented for designing the variable-frequency feedback controller. Furthermore, a new methodology to design a VIT is developed to overcome the challenges associated with small coupling coefficients and guarantee a complete magnetic integration of the tank inductances. All theoretical results presented herein are verified through simulations and experiments performed on hardware prototypes designed in the lab.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Evolution of microstructures in radiation fields using a coupled binary-collision Monte Carlo phase field approach

The simulation of radiation effects in materials broadly falls into two categories. At short time and length scales lies the modeling of primary radiation damage, such as point defect creation, energy deposition, and ballistic mixing. This is followed by the modeling at longer time scales of thermally activated microstructure evolution and defect reactions, such as recombination, clustering, and coarsening. The binary collision Monte Carlo method is an established, numerically efficient method for the computation of primary radiation damage. Conversely, the phase field method is a state of the art method for microstructure evolution on longer time and length scales. Here we present a concurrent coupling of these two methods, overcoming the difference between the discrete object Monte Carlo paradigm for primary radiation damage and the continuum field variable approach for microstructure evolution. The coupling is bidirectional, in which the microstructure evolution in the MOOSE finite element frame- work provides the spatial scattering data set for the charged particle trans- port and receives point defect, mass transport, and heat source terms from the simulated collision cascades that contribute to the field variable evolution. The concurrent coupling scheme is implemented in the code Magpie and demonstrated by investigating patterning for a model irradiated immiscible binary alloy. The results from the coupled binary collision Monte Carlo/phase field simulations reproduce the results of analytical models for phase separation, phase mixing, and patterning, supporting the approach and indicating its utility for modeling real materials systems.

36 MATERIALS SCIENCE↗

A low temperature unitized regenerative fuel cell realizing 60% round trip efficiency and 10 000 cycles of durability for energy storage applications

Unitized regenerative fuel cells (URFC) convert electrical energy to and from chemical bonds in hydrogen. URFCs have the potential to provide economical means for efficient long-term, seasonal, energy storage and on-demand conversion back to electrical energy. We first optimize the catalyst layer for discrete electrolyzer and fuel cell and then configure the URFC. The goal is to identify a cost competitive configuration for URFCs, and demonstrate it in terms of upper limit of round trip efficiencies (RTEs). Two possible configurations of URFCs are compared via experiments and techno-economic analysis (TEA), which emphasize the advantages of the unconventional constant-electrode (CE) URFC over the traditional constant-gas (CG) configuration. We also study the stability via accelerated stress tests (ASTs) and demonstrate steady state operation in a daily cycle for day to night energy shifting. From the investigations, the optimum composition of the URFC anode catalyst layer is 90 at% Ir-black balanced by Pt-black for both CE and CG configurations. At 80 °C and 1 A cm -2 , the optimized CE URFC achieves 57% and 60% RTE with air and O 2 as the reductant gases, respectively. We then evaluated the differences in durability using an AST over 10k charge–discharge cycles; the results reveal that the wider potential window at the anode in CE (0.05–1.55 V) has minimal effect on catalyst layer stability compared to CG (0.55–1.55 V). Furthermore, there was no degradation up to the range of 2k–5k cycles; beyond that the fuel cell (discharge) performance degraded while the electrolyzer (charge) performance was still stable. Finally, the observations here indicate substantial potential to employ URFCs as efficient and cost-effective bidirectional energy-conversion devices within energy storage and utilization systems after appropriate technological and operational optimizations.

25 ENERGY STORAGE↗

Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

High-Power Oak Ridge Converter (ORC) for Extreme Fast Charging Applications

This project report presents a novel power converter system called Oak Ridge Converter (ORC), a patented technology developed by the Oak Ridge National Laboratory (ORNL) for XFC wireless EV charging systems. ORC integrates the grid interface converter (also known as the active front-end rectifier with power factor correction) with the high-frequency inverter stage, promoting size and cost-effective charging technology with reduced infrastructure costs. The integration of the front-end rectifier with the high-frequency inverter truly eliminates one power conversion stage and achieves more than 33% size, weight, volume, and cost reduction on the wireless charging systems. Furthermore, ORC eliminates the primary side direct current (DC) bus bulk capacitors that are usually aluminum electrolytic capacitors and replaces them with very small, cost-effective, highly reliable, and high-temperature operation-capable alternate current (AC) film capacitors. ORC is also applicable to both single-phase and poly-phase couplers. When used with polyphase couplers, ORC further improves the power density of the overall system with higher power density power electronics. Moreover, ORC is inherently bidirectional and allows the system to provide power back to the grid for grid ancillary or grid support services. The ORC, based on a patented ORNL technology, is an excellent approach to resolving the high-power charging problems as described above, which directly converts the 60 hertz (Hz) line frequency into high frequency (i.e., 85 kilohertz (kHz)) to use with a high-frequency isolation transformer or wireless charging coils while eliminating the primary side number of power conversion stages from two to one. The result of the project is a prototype and reference design for a high-power wireless charging system—including power electronics, magnetics, and thermal—serving as a baseline for product development. The proposed system results are demonstrated for 270 kW of output power, with the system's overall efficiency of 92% from the AC grid, achieving less than 3% current total harmonic distortion (THD) and around 0.99 power factor (PF).

33 ADVANCED PROPULSION SYSTEMS↗

A Learning-based Supervisory Control Architecture for Electric Vehicle Charging System Paired with Energy Storages

A Machine Learning-based predictive model is developed for optimal dispatching energy storage system integrated with Electric Vehicle battery charger. The model is effectively trained using transfer learning algorithm and successfully validated via measurement data to achieve high fidelity and accuracy. The study findings provide possibilities for future development of the presented approach to implement computational heavy predictive algorithms with multi-step predictions in emerging modular bidirectional charger topologies to realize vehicle-to-grid (V2G) technology. The online tuning can be explored using the new measurements obtained during the operation, henceforth, enhancing the controller performance for integrating multiple DERs into distribution power networks that shows huge interest for the utilities and regulatory agencies. Multiple operation scenatios have been evaluated and simulation results are discussed to verify intended performance of the proposed control solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications: Preprint

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaNbased DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50 W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaN-based DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Characterization of InCharge™ ICE-66 V2X Bidirectional DC Fast Charger

Vehicle-to-grid (V2G) technology extends the role of Plug-in Hybrid Vehicle’s (PHEV) and Battery Electric Vehicle’s (BEV) batteries beyond transportation by enabling bidirectional power transfer between the vehicle's onboard energy storage and the utility grid. Modern battery-powered vehicles are equipped with high-capacity battery packs that remain stationary and underutilized for the majority of their operational life. A vehicle used for daily commuting may be parked and connected to charging infrastructure for 18–20 hours per day, representing a significant untapped energy resource. When considered at scale, the aggregated storage capacity of a modest fleet of 10–15 vehicles within a single parking facility can reach the MWh range, sufficient to partially offset peak demand for a mid-size commercial building or contribute meaningful ancillary services to the local grid. The ability to charge during off-peak periods when electricity prices are low and discharge during peak demand when prices are high positions EV batteries as distributed energy arbitrage assets, with the potential to offset vehicle ownership and charging costs. Beyond energy arbitrage, V2G-capable assets can provide ancillary grid services through active and reactive power injections. Active power supports grid frequency regulation, while reactive power supports local voltage regulation. Together, these capabilities establish V2G as a technically promising and economically relevant pathway toward greater integration of battery-powered vehicles into the broader energy system.

33 ADVANCED PROPULSION SYSTEMS↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

2022 Component Innovation Awardee: Windurance

Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.

CIP↗

Preventing Voltage Divergence in Series-Stacked Bidirectional Battery Energy Storage DC-DC Converter under Asymmetrical Operating Conditions

DC stacked topologies have gained popularity for interfacing individual photovoltaic panels to a high-voltage DC bus. A similar approach can be used to interface individual battery packs to the same DC bus, which allows active balancing of battery substrings and the use of lower voltage switches. Any imbalance in battery current, however, can cause the converter output voltages to diverge. This paper describes the source of voltage divergence and demonstrates a solution that allows seamless stacking of multiple battery packs to be interfaced to a high voltage DC bus. To prevent the voltage divergence phenomenon and allow asymmetrical battery charging for efficient battery state of charge management, the PI-based decentralized voltage control enabling both capacitor voltage sharing and asymmetrical capacitor voltage control is proposed. The effectiveness of the decentralized voltage control strategy is demonstrated through controller hardware-in-the-loop test results.

Kim, Namwon↗

Hardware Design and Demonstration of a 100kW, 99% Efficiency Dual Active Half Bridge Converter Based on 1700V SiC Power MOSFET

High efficiency, high density and galvanically isolated power converters are attractive for numerous medium voltage high power applications. This paper presents a 1.5kVdc, 100kW bidirectional Dual Active Half Bridge (DAHB) using newly developed 1.7kV SiC MOSFET modules. The DAHB achieved an efficiency of 98.6% at full load of 100kW and a maximum of 99% at 45kW, operating as an isolated DC/DC converter. The converter also achieved an efficiency of 97.8% operating as an isolated DC/AC inverter. An optimized PCB-based busbar design has significantly reduced the voltage overshoot across the device, making the design suitable for 1500Vdc input application such as 1500V PV inverters. Typical partial discharge inception voltage (PDIV) of the optimized PCB busbar is 1.7kVpeak with total charge <10pC. The power density of the DAHB converter is 1.8MVA/m 3 which is much higher than traditional two-stage industry products. The DAHB converter can be used as a building block for a 4.16kV/1MVA utility scale PV systems with input parallel and output series configuration.

Xu, Wei↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗