Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Detector Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation & Development of Algorithms & Techniques for Streaming Detector Readout

The advancement in microelectronics capabilities, computing, and data science in the last decade has been remarkable. With the start of the 12 GeV Science Program at Jefferson Lab (JLab) and the conceptual detector design for the upcoming Ion Collider (EIC) in mind, we have evaluated and developed the possibility of evolving and improving the existing nuclear science research workflow based on these advances. Specifically, we have prototyped components of streaming readout.

43 PARTICLE ACCELERATORS↗

Distributed state machine supervision for long-baseline gravitational-wave detectors

The Laser Interferometer Gravitational-wave Observatory (LIGO) consists of two identical yet independent, widely separated, long-baseline gravitational-wave detectors. Each Advanced LIGO detector consists of complex optical-mechanical systems isolated from the ground by multiple layers of active seismic isolation, all controlled by hundreds of fast, digital, feedback control systems. This article describes a novel state machine-based automation platform developed to handle the automation and supervisory control challenges of these detectors. The platform, called Guardian, consists of distributed, independent, state machine automaton nodes organized hierarchically for full detector control. User code is written in standard Python and the platform is designed to facilitate the fast-paced development process associated with commissioning the complicated Advanced LIGO instruments. While developed specifically for the Advanced LIGO detectors, Guardian is a generic state machine automation platform that is useful for experimental control at all levels, from simple table-top setups to large-scale multi-million dollar facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Yale High Energy Physics Research: Precision Studies of Reactor Antineutrinos

This report presents experimental research at the intensity frontier of particle physics with particular focus on the study of reactor antineutrinos and the precision measurement of neutrino oscillations. The experimental neutrino physics group of Professor Heeger and Senior Scientist Band at Yale University has had leading responsibilities in the construction and operation of the Daya Bay Reactor Antineutrino Experiment and made critical contributions to the discovery of non-zero$\theta_{13}$. Heeger and Band led the Daya Bay detector management team and are now overseeing the operations of the antineutrino detectors. Postdoctoral researchers and students in this group have made leading contributions to the Daya Bay analysis including the prediction of the reactor antineutrino flux and spectrum, the analysis of the oscillation signal, and the precision determination of the target mass yielding unprecedented precision in the relative detector uncertainty. Heeger's group is now leading an R\&D effort towards a short-baseline oscillation experiment, called PROSPECT, at a US research reactor and the development of antineutrino detectors with advanced background discrimination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fission Meter Information Barrier Attribute Measurement System: FY2018 Office of Nuclear Verification FNI/UKC Task 2 Documentation Package

The ORTEC Fission Meter is a neutron multiplicity detector developed by Oak Ridge, TN based Advanced Measurement Technology (AMETEK), ORTEC Division. Data analysis techniques developed for neutron multiplicity detectors allows determination of mass and multiplication of unknown objects of special nuclear material (SNM). This can be done based on the physics of fission neutrons with little or no a priori information about the object. The articulating panel design and “5-Mode Counter” neutron multiplicity data-acquisition hardware were licensed to ORTEC by Lawrence Livermore National Laboratory in 2005 based on a 2004 prototype. The “5-Mode Counter” development started in 2000 in order to produce a compact neutron multiplicity file containing the full neutron count timing distribution. Development of this hardware along with the prototype detector design continued through 2004. Photographs of the Fission Meter are shown in Figure 1. In 2011, the Lawrence Livermore National Laboratory developed a software-based information barrier (IB) for the Fission Meter to control transmission of some for potential use in treaty applications. This IB was extended over the next several years to include improvements to the algorithms, more automated processing, and list mode data acquisition and processing. This report provides design and operational documentation for the Fission Meter and the Information Barrier additions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced X-ray Collection and Collimation Optic

Incom Inc. and Brookhaven National Laboratory have a mutual interest in developing and testing an X-ray optic that will function in an advanced detector system. This optic leverages the development work already carried out at Incom in drawing hollow core capillary structures. Incom has developed a revolutionary method for fabricating arrays of hollow capillary structures out of several types of glass and is investigating several market applications for this technology, including large area (9”x9”) microchannel plates for electron amplification, hydrogen storage, and x-ray optics, the subject of this application. Methods have been developed for fabricating hexagonally arranged polycapillaries with outside diameters in the range of .020”-0.25” with capillary internal diameters from 2-350+ µm. Initial trials of capillary tapering have yielded promising results. BNL’s expertise in the development of X-ray optics, especially x-ray spectrometers will be utilized in the development of the unique lens concept and its integration into the spectrometer.

42 ENGINEERING↗

TH-A-17A-01: Innovation in PET Instrumentation and Applications

Innovation in PET instrumentation has led to the new millennium revolutionary imaging applications for diagnosis, therapeutic guidance, and development of new molecular imaging probes, etc. However, after several decades innovations, will the advances of PET technology and applications continue with the same trend and pace? What will be the next big thing beyond the PET/CT, PET/MRI, and Time-of-flight PET? How will the PET instrumentation and imaging performance be further improved by novel detector research and advanced imaging system development? Or will the development of new algorithms and methodologies extend the limit of current instrumentation and leapfrog the imaging quality and quantification for practical applications? The objective of this session is to present an overview of current status and advances in the PET instrumentation and applications with speakers from leading academic institutes and a major medical imaging company. Presenting with both academic research projects and commercial technology developments, this session will provide a glimpse of some latest advances and challenges in the field, such as using semiconductor photon-sensor based PET detectors to improve performance and enable new applications, as well as the technology trend that may lead to the next breakthrough in PET imaging for clinical and preclinical applications. Both imaging and image-guided therapy subjects will be discussed. Learning Objectives: Describe the latest innovations in PET instrumentation and applications Understand the driven force behind the PET instrumentation innovation and development Learn the trend of PET technology development for applications.

60 APPLIED LIFE SCIENCES↗

Advanced Mixed-Mode Pixel Array Detector for X-rays Above 20 keV (Final Report)

The objective of the work reported upon was to perform research and development and test advanced prototype imaging x-ray detectors needed to meet pressing scientific research needs at U.S. x-ray synchrotron user facilities. The high x-ray brightness of the Nation’s x-ray synchrotron sources in the DOE National Laboratories holds promise to advance science and technology in a broad range of fundamental and applied disciplines, including physics, chemistry, biomedical areas and engineering. At present, progress in many areas is being limited not by the x-ray source but by the lack of imaging x-ray detectors capable of meeting experimental needs. Specifically, there is pressing need for imaging detectors with high dynamic range, low noise, high frame rates and the ability to capture x-ray images with x-rays of energy > 20 keV. This Final Technical Report summarizes progress made at Cornell University on novel integrating x-ray detectors that address these characteristics.

36 MATERIALS SCIENCE↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science Addendum

Activation detectors developed at LLNL for measuring real-time neutron fluence from fusion sources are used in the broader fusion community. The recommended fluence operating range of this diagnostic is 5x10 2 – 1x10 6 n/cm2. The upper limit on this fluence range is set by the dead time caused by data transfer between the detector and data acquisition computer. Delaying the start of counting is a possible strategy to operate these detectors in higher fluences.

42 ENGINEERING↗

First results from the TUS orbital detector in the extensive air shower mode

TUS (Tracking Ultraviolet Set-up), the first orbital detector of extreme energy cosmic rays (EECRs), those with energies above 50 EeV, was launched into orbit on April 28, 2016, as a part of the Lomonosov satellite scientific payload. The main aim of the mission is to test a technique of registering fluorescent and Cherenkov radiation of extensive air showers generated by EECRs in the atmosphere with a space telescope. We present preliminary results of its operation in a mode dedicated to registering extensive air showers in the period from August 16, 2016, to November 4, 2016. No EECRs have been conclusively identified in the data yet, but the diversity of ultraviolet emission in the atmosphere was found to be unexpectedly rich. We discuss typical examples of data obtained with TUS and their possible origin. The data is important for obtaining more accurate estimates of the nocturnal ultraviolet glow of the atmosphere, necessary for successful development of more advanced orbital EECR detectors including those of the KLYPVE (K-EUSO) and JEM-EUSO missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Proton light yield in organic scintillators using a double time-of-flight technique

Recent progress in the development of novel organic scintillators necessitates modern characterization capabilities. As the primary means of energy deposition by neutrons in these materials is n-p elastic scattering, knowledge of the proton light yield is paramount. This work establishes a new model-independent method to continuously measure the proton light yield in organic scintillators over a broad energy range. Using a deuteron breakup neutron source at the 88-in. Cyclotron at Lawrence Berkeley National Laboratory and an array of organic scintillators, the proton light yield of EJ-301 and EJ-309, commercially available organic liquid scintillators from Eljen Technology, was measured via a double time-of-flight technique. The light yield was determined using a kinematically over-constrained system in the proton energy range of 1–20 MeV. The effect of the pulse integration length on the magnitude and shape of the proton light yield relation was also explored. In conclusion, this work enables accurate simulation of the performance of advanced neutron detectors and supports the development of next-generation neutron imaging systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoluminescence of radiation-induced color centers in lithium fluoride thin films for advanced diagnostics of proton beams

Systematic irradiation of thermally evaporated 0.8 μm thick polycrystalline lithium fluoride films on glass was performed by proton beams of 3 and 7 MeV energies, produced by a linear accelerator, in a fluence range from 10{sup 11} to 10{sup 15} protons/cm{sup 2}. The visible photoluminescence spectra of radiation-induced F{sub 2} and F{sub 3}{sup +} laser active color centers, which possess almost overlapping absorption bands at about 450 nm, were measured under laser pumping at 458 nm. On the basis of simulations of the linear energy transfer with proton penetration depth in LiF, it was possible to obtain the behavior of the measured integrated photoluminescence intensity of proton irradiated LiF films as a function of the deposited dose. The photoluminescence signal is linearly dependent on the deposited dose in the interval from 10{sup 3} to about 10{sup 6 }Gy, independently from the used proton energies. This behavior is very encouraging for the development of advanced solid state radiation detectors based on optically transparent LiF thin films for proton beam diagnostics and two-dimensional dose mapping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Particle and nuclear physics instrumentation and its broad connections

Subatomic physics shares with other basic sciences the need to innovate, invent, and develop tools, techniques, and technologies to carry out its mission to explore the nature of matter, energy, space, and time. In some cases, entire detectors or technologies developed specifically for particle physics research have been adopted by other fields of research or in commercial applications. In most cases, however, the development of new devices and technologies by particle physics for its own research has added value to other fields of research or to applications beneficial to society by integrating them in the existing technologies. Thus, detector research and development has not only advanced the current state of technology for particle physics, but has often advanced research in other fields of science and has underpinned progress in numerous applications in medicine and national security. At the same time particle physics has profited immensely from developments in industry and applied them to great benefit for the use of particle physics detectors. Finally, this symbiotic relationship has seen strong mutual benefits with sometimes unexpected far reach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrating Detectors to Meet National Facility Needs

The objective of the work reported upon was to perform research and develop and test advanced prototype imaging x-ray detectors needed to meet pressing scientific research needs at U.S. synchrotron x-ray user facilities. The high x-ray brightness of the Nation’s x-ray synchrotron sources in the DOE National Laboratories holds promise to advance science and technology in a broad range of fundamental and applied disciplines, including physics, chemistry, biomedical areas and engineering. At present, progress in many areas is limited not by the x-ray source but by the lack of imaging x-ray detectors capable of meeting experimental needs. Specifically, there is pressing need for imaging detectors with high dynamic range, low noise, high frame rates and the ability to capture x-ray images with x-rays of energy > 20 keV. This Final Technical Report summarizes progress made at Cornell University on novel integrating x-ray detector platforms that address these characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Materials for Gamma Radiation Sensors

Sensors used for spectroscopic measurements of gamma radiation are most often scintillator or semiconductor materials. An overview is provided in this chapter on the materials and development techniques used in producing spectroscopic gamma radiation sensors. Challenges that prevent a perfect sensor are discussed along with the reasons why some sensor materials are ubiquitous despite their performance limitations. The types of sensors commonly used as detectors are discussed along with their key physical properties and electronic characteristics. Materials commonly utilized in radiation detectors are then reviewed to highlight how sensor materials have advanced since the earliest gamma detectors were developed

Johns, Paul M.↗

Atomic-Scale Characterization of Oxide Interfaces and Superlattices Using Scanning Transmission Electron Microscopy

Scanning transmission electron microscopy (STEM) has become one of the fundamental tools to characterize oxide interfaces and superlattices. Atomic-scale structure, chemistry, and composition mapping can now be conducted on a wide variety of materials systems thanks to the development of aberration-correctors and advanced detectors. STEM imaging and diffraction, coupled with electron energy loss (EELS) and energy-dispersive X-ray (EDS) spectroscopies, offer unparalleled, high-resolution analysis of structure-property relationships. In this chapter we highlight investigations into key phenomena, including interfacial conductivity in oxide superlattices, charge screening effects in magnetoelectric heterostructures, the design of high-quality iron oxide interfaces, and the complex physics governing atomic-scale chemical mapping. These studies illustrate how unique insights from STEM characterization can be integrated with other techniques and first-principles calculations to develop better models for the behavior of functional oxides.

Characterization↗

Real-Time Detection Methods to Monitor TRU Compositions in UREX+Process Streams

The U.S. Department of Energy has developed advanced methods for reprocessing spent nuclear fuel. The majority of this development was accomplished under the Advanced Fuel Cycle Initiative (AFCI), building on the strong legacy of process development R&D over the past 50 years. The most prominent processing method under development is named UREX+. The name refers to a family of processing methods that begin with the Uranium Extraction (UREX) process and incorporate a variety of other methods to separate uranium, selected fission products, and the transuranic (TRU) isotopes from dissolved spent nuclear fuel. It is important to consider issues such as safeguards strategies and materials control and accountability methods. Monitoring of higher actinides during aqueous separations is a critical research area. By providing on-line materials accountability for the processes, covert diversion of the materials streams becomes much more difficult. The importance of the nuclear fuel cycle continues to rise on national and international agendas. The U.S. Department of Energy is evaluating and developing advanced methods for safeguarding nuclear materials along with instrumentation in various stages of the fuel cycle, especially in material balance areas (MBAs) and during reprocessing of used nuclear fuel. One of the challenges related to the implementation of any type of MBA and/or reprocessing technology (e.g., PUREX or UREX) is the real-time quantification and control of the transuranic (TRU) isotopes as they move through the process. Monitoring of higher actinides from their neutron emission (including multiplicity) and alpha signatures during transit in MBAs and in aqueous separations is a critical research area. By providing on-line real-time materials accountability, diversion of the materials becomes much more difficult. The objective of this consortium was to develop real time detection methods to monitor the efficacy of the UREX+ process and to safeguard the separated TRUs against unlawful diversion from within a processing facility. To achieve this, a comprehensive strategy was implemented to incorporate traditional detectors and advanced Tensioned Metastable Fluid (TMFD) metastable fluid detectors (developed, in part, under this project) into a novel detector assembly coupled to the UREX+ centrifugal contactor array. The sections below provide a brief summary of the technical achievements completed during this project. The principal outcomes are documented in more complete details contained the doctoral dissertations and masters theses, journal papers, conference proceedings and additional items for more than the 35 publications that are listed in the program bibliography in Section 3.

McDeavitt, Sean M.↗