Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR POLLUTION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

Monitoring of Air Pollution by Satellites (MAPS), phase 1

Results are reported upon which the design of a satellite remote gas filter correlation (RGFC) instrument can be based. Although a final decision about the feasibility of measuring some of the pollutants with the required accuracy is still outstanding and subject to further theoretical and experimental verifications, viable concepts are presented which permit the initiation of the design phase. The pollutants which are of concern in the troposphere and stratosphere were selected. The infrared bands of these pollutants were identified, together with the bands of interfering gases, and the line parameters of the pollutants as well as interfering gases were generated through a computer program. Radiative transfer calculations (line-by-line) were made to establish the radiation levels at the top of the atmosphere and the signal levels at the detector of the RGFC instrument. Based upon these results the channels for the RGFC were selected. Finally, the problem areas, which need further investigations, were delineated and the supporting data requirements were established.

Ludwig, C. B.↗

Microwave rotational spectroscopy: A physical technique for specific pollutant monitoring

Evidence is presented that microwave rotational spectroscopy can be developed for use in air pollution monitoring, with the employment of a diode-cavity spectrometer capable of detecting small concentrations of NO2, SO2, H2CO, and HN3 gas with very high specificity. The theory behind the technique is discussed, together with its application and experimental results.

Hrubesh, L. W.↗

Assessment of exposure to air pollution in children: Determining whether wearing a personal monitor affects physical activity

Highlights: • Personal air pollution exposure should not interfere with usual patterns of behavior. • Overall, personal pollution samplers did not influence usual patterns of behavior in children. • Small decreases in activity while wearing the monitors were noted among the youngest participants. Personal air pollution monitoring in research studies should not interfere with usual patterns of behavior and bias results. In an urban pediatric cohort study we tested whether wearing an air monitor impacted activity time based on continuous watch-based accelerometry. The majority (71%) reported that activity while wearing the monitor mimicked normal activity. Correspondingly, variation in activity while wearing versus not wearing the monitor did not differ greatly from baseline variation in activity (P = 0.84).

54 ENVIRONMENTAL SCIENCES↗

Potentially efficient forest and range applications of remote sensing using earth orbital space craft, circa 1980

Sixteen remote sensing applications or groups of related applications judged to be most important of any in the forestry and range disciplines were evaluated. In one application, major land classification, large amounts of useful data are anticipated to be contributed by space sensors in 1980. In four applications moderate amounts are anticipated to be so contributed. These are timber inventory, range inventory, fire weather forecasting, and monitoring snowfields. In the following seven applications small but significant amounts of data are anticipated to be contributed by space sensors: (1) detailed land classification; (2) inventory of wildlife habitat; (3) recreation resource inventory; (4) detecting stresses on the vegetation (5) monitoring air pollution caused by wildfires and prescribed burning; (6) monitoring water cycle, (7) pollution and erosion; and (8) evaluating damage to forests and ranges.

Wilson, R. C.↗

Hourly land-use regression models based on low-cost PM monitor data

Highlights: • A network of 23 low-cost PM monitors was deployed across an urban area. • Land use regression models predict the hourly intra-urban PM variations. • Coefficients of determination for hourly PM predictions ranged 0.66–0.76. • Low-cost PM monitor data need to be carefully evaluated before use. • The combination of low-cost monitors and modeling provides useful PM estimates. Land-use regression (LUR) models provide location and time specific estimates of exposure to air pollution and thereby improve the sensitivity of health effects models. However, they require pollutant concentrations at multiple locations along with land-use variables. Often, monitoring is performed over short durations using mobile monitoring with research-grade instruments. Low-cost PM monitors provide an alternative approach that increases the spatial and temporal resolution of the air quality data. LUR models were developed to predict hourly PM concentrations across a metropolitan area using PM concentrations measured simultaneously at multiple locations with low-cost monitors. Monitors were placed at 23 sites during the 2015/16 heating season. Monitors were externally calibrated using co-located measurements including a reference instrument (GRIMM particle spectrometer). LUR models for each hour of the day and weekdays/weekend days were developed using the deletion/substitution/addition algorithm. Coefficients of determination for hourly PM predictions ranged from 0.66 and 0.76 (average 0.7). The hourly-resolved LUR model results will be used in epidemiological studies to examine if and how quickly, increases in ambient PM concentrations trigger adverse health events by reducing the exposure misclassification that arises from using less time resolved exposure estimates.

54 ENVIRONMENTAL SCIENCES↗

TPSAS-NF1676L-30290-DND

The Summer 2017 Ozone Water Land Environmental Transition Study (OWLETS) mission set out to compare the differences in ozone concentrations between inland measurements of air quality, specifically at Langley Research Center (LaRC), and measurements taken over water, specifically on the Chesapeake Bay Bridge Tunnel (CBBT), as well as the vertical profiles above each location. Current weather models often predict a gradient in ozone concentration between land and ocean and this campaign attempted to capture this difference using hand-held Personal Ozone Monitors (POMs) in correspondence to ozonesondes and LIDAR measurements. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) is the first geostationary satellite that will take hourly measurements to monitor air pollutants across North America using solar backscatter. The small footprint allows for higher spatial resolution readings of many parameters including O3, NO2 , and aerosol. TEMPO’s higher resolution readings would benefit from validation techniques on the ground. Validation methods usually include comparison to air quality monitoring stations, but they could also incorporate other forms of validation such as comparison to small sensors. In cooperation with TEMPO, OWLETS aims to provide the user community high resolution temporal and spatial, both horizontal and vertical, variability of O3 simultaneously over the land and water during various air quality events to improve forecast models and air quality satellite retrievals. Together, these missions will improve spatial resolution and capture temporal variability of air quality over North America.

Emily Gargulinski↗

Comparisons of Spectral Aerosol Single Scattering Albedo in Seoul, South Korea

Quantifying aerosol absorption at ultraviolet (UV) wavelengths is important for monitoring air pollution and aerosol amounts using current (e.g., Aura/OMI (Ozone Monitoring Instrument)) and future (e.g., TROPOMI (TROPOspheric Monitoring Instrument), TEMPO (Tropospheric Emissions: Monitoring of POllution), GEMS (Geostationary Environment Monitoring Spectrometer) and Sentinel-4) satellite measurements. Measurements of column average atmospheric aerosol single scattering albedo (SSA) are performed on the ground by the NASA AERONET (AEROsol robotic NETwork) in the visible (VIS) and near-infrared (NIR) wavelengths and in the UV-VIS-NIR by the SKYNET (SKY radiometer NETwork) networks. Previous comparison studies have focused on VIS and NIR wavelengths due to the lack of co-incident measurements of aerosol and gaseous absorption properties in the UV. This study compares the SKYNET-retrieved SSA in the UV with the SSA derived from a combination of AERONET, MFRSR (MultiFilter Rotating Shadowband Radiometer), and Pandora (AMP) retrievals in Seoul, South Korea, in spring and summer 2016. The results show that the spectrally invariant surface albedo assumed in the SKYNET SSA retrievals leads to underestimated SSA compared to AMP values at near UV wavelengths. Re-processed SKYNET inversions using spectrally varying surface albedo, consistent with the AERONET retrieval improve agreement with AMP SSA. The combined AMP inversions allow for separating aerosol and gaseous (NO2 and O3) absorption and provide aerosol retrievals from the shortest UVB (305 nanometers) through VIS to NIR wavelengths (870 nanometers).

aerosol and gaseous absorption properties↗

Data Report for Monitoring at Six West Virginia Marcellus Shale Development Sites using NETL’s Mobile Air Monitoring Laboratory (July–November 2012)

The West Virginia Department of Environmental Protection’s Office of Oil and Gas was directed according to the Natural Gas Horizontal Well Control Act of December 14, 2011 (West Virginia Code §22-6A) to conduct studies of horizontal well drilling activities related to air quality. The planned study, “Noise, Light, Dust, Volatile Organic Compounds Related to Well Location Restrictions,” required determination of the effectiveness of a 625 ft minimum set-back from the center of the pad of a horizontal well drilling site to the nearest occupied dwelling. An investigation was conducted at seven drilling sites by West Virginia University (WVU) and the National Energy Technology Laboratory (NETL) to collect data on dust, hydrocarbon compounds and on noise, radiation, and light levels. NETL’s role in this study was to collect measurements of ambient pollutant concentrations at six of the seven selected sites using NETL’s Mobile Air Monitoring Laboratory. The trailer-based laboratory was situated a distance of 492–1,312 ft from each well pad, on which activities included well pad construction, vertical drilling, horizontal drilling, hydraulic fracturing, and flaring, with the objective of evaluating the air quality impact of each activity for 1–4 weeks per site. Measured pollutants included volatile organic compounds (VOCs), coarse and fine particulate matter (PM 10 and PM 2.5 , respectively), ozone, methane (CH 4 ), carbon dioxide (CO 2 ), carbon isotopes of CH 4 and CO 2 , organic carbon (OC), elemental carbon (EC), oxides of nitrogen (NOx), and sulfur dioxide (SO 2 ).

03 NATURAL GAS↗

Managing Toxicological Risks: The Legacy of Shuttle Operations

Space toxicology greatly matured as a result of research and operations associated with the Shuttle. Materials offgassing had been a manageable concern since the Apollo days, but we learned to pay careful attention to compounds that could escape containment, to combustion events, to toxic propellants, to overuse of utility compounds, and to microbial and human metabolites. We also learned that flying real-time hardware to monitor air pollutants was a pathway with unanticipated speed bumps. Each new orbiter was tested for any excess offgassing products that could pollute the air during flight. In the late 1990s toxicologists and safety experts developed a 5-level toxicity rating system to guide containment of toxic compounds. This system is now in use aboard the International Space Station (ISS). Several combustion events during Shuttle Mir and also during Shuttle free-flight impelled toxicologists to identify hardware capable of monitoring toxic products; however, rapid adaptation of the hardware for the unique conditions of spaceflight caused unexpected missteps. Current and planned combustion analyzers would be useful to commercial partners that wish to manage the risk of health effects from thermal events. Propellants received special attention during the Shuttle program because of the possibility of bringing them into the habitable volume on extravehicular activity suits. Monitors for the airlocks were developed to mitigate this risk. Utility materials, such as lubricants, posed limited toxicological problems because water was not recovered. One clearly documented case of microbial metabolites polluting the Shuttle atmosphere was noted, and this has implications for commercial flights and control of microbes. Finally, carbon dioxide, the major human metabolite, episodically presented air quality problems aboard Shuttle, especially when nominal air flows were obstructed. Commercial vehicles must maintain robust air circulation given the anticipated high density of human occupants.

James, John T.↗

“How do you know those particles are from cigarettes?”: An algorithm to help differentiate second-hand tobacco smoke from background sources of household fine particulate matter

Second-hand smoke (SHS) at home is a target for public health interventions, such as air quality feedback interventions using low-cost particle monitors. However, these monitors also detect fine particles generated from non-SHS sources. }The Dylos DC1700 reports particle counts in the coarse and fine size ranges. As tobacco smoke produces far more fine particles than coarse ones, and tobacco is generally the greatest source of particulate pollution in a smoking home, the ratio of coarse to fine particles may provide a useful method to identify the presence of SHS in homes.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Chemical Speciation Monitor (ACSM) Time-of-Flight (ToF) from Kennaook Cape Grim

When utilizing these data from Kennaook Cape Grim please acknowledge the Australian Bureau of Meteorology and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) for their long-term and continued support of the Kennaook Cape Grim Baseline Air Pollution Monitoring Station. In addition, please contact the Lead Scientists responsible for the collection of these data sets (melita.keywood@csiro.au, ruhi.humphries@csiro.au and Erin.dunne@csiro.au) to discuss collaboration and authorship opportunities.

54 ENVIRONMENTAL SCIENCES↗

Key scientific findings and policy- and health-relevant insights from the US. Environmental Protection Agency's Particulate Matter Supersites Program and related studies: an integration and synthesis of results

Over 400 peer-reviewed journal articles and likely more than 1000 presentations resulted from the research conducted through EPA's PM Supersites Program. From the start, the program was developed with a policy focus - providing new information on the accumulation and sources of PM in air on urban and regional scales that might allow for the development of more effective approaches to reducing ambient concentrations of PM to below NAAQS levels. This paper synthesizes and integrates the atmospheric sciences findings from which are interpreted a series of policy-relevant and health-relevant insights developed to support policy decisions on approaches to reduce PM in air and to assist the health-effects and exposure science communities with future research planning. 548 refs., 10 figs., 13 tabs.

01 COAL, LIGNITE, AND PEAT↗

Source apportionment: findings from the US supersites program

Receptor models are used to identify and quantify source contributions to particulate matter and volatile organic compounds based on measurements of many chemical components at receptor sites. These components are selected based on their consistent appearance in some source types and their absence in others. UNMIX, positive matrix factorization (PMF), and effective variance are different solutions to the chemical mass balance (CMB) receptor model equations and are implemented on available software. In their more general form, the CMB equations allow spatial, temporal, transport, and particle size profiles to be combined with chemical source profiles for improved source resolution. Although UNMIX and PMF do not use source profiles explicitly as input data, they still require measured profiles to justify their derived source factors. The U.S. Supersites Program provided advanced datasets to apply these CMB solutions in different urban areas. Still lacking are better characterization of source emissions, new methods to estimate profile changes between source and receptor, and systematic sensitivity tests of deviations from receptor model assumptions. 154 refs.

02 PETROLEUM↗