Axions beyond Gen 2

The QCD (Quantum ChromoDynamics) axion emerged as one of the best-motivated dark matter candidates. In 2018, the Axion Dark Matter eXperiment (ADMX), one of the U.S. Department of Energy’s “Gen 2” flagship dark-matter projects, demonstrated first sensitivity to the highly plausible “DFSZ” dark matter axion couplings over a small frequency range. We anticipate this development marks the first step in constructing yet more powerful experiments that can explore large swaths of the axion parameter space at high sensitivity and result in a discovery. But, realizing this requires advances in both our understanding of the theory and experiment design. Between 25 January and 27 January 2021, the “Axions Beyond Gen 2 Workshop” was held, where selected members of the community discussed our broad understanding of the QCD axion and charted a course for future experiments having sensitivity and mass reach well beyond the current “Gen 2” experiments. These proceedings are summaries of the topics presented and discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel frequency tunable systems for superconducting cavities (Abbreviated Report)

Ultra-low loss microwave resonant cavities are the backbone of quantum information science (QIS) and axion/dark matter detection (ADMX), but one of the challenges in developing 3D cavity systems has been finding a tuning mechanism that does not drastically reduce the cavity quality factor (Q) but still provides a large operating bandwidth. To alleviate this limitation, we proposed to fabricate a high-Q, 3D microwave cavity with an integrated hybrid mechanical/electrical tuning scheme to achieve both coarse and rapid fine tuning. We implemented two tuning schemes: one using a shift in kinetic inductance and one utilizing mechanical motion. We found that the kinetic inductance method did not yield any tunability in the cavity mode, but the mechanical adjustment successfully moved the cavity resonance. The quality factors obtained were lower than originally proposed, but there is potential to improve the design on further iterations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid Acceleration of Outcomes in Physics: Final Report for the Nuclear Physics, Particle Physics, Astrophysics, and Cosmology (NPAC) Umbrella Project

The Nuclear Physics, Particle Physics, Astrophysics, and Cosmology (NPAC) Initiative addresses the first question by supporting experiments that would directly detect dark matter when it interacts with very sensitive detectors. There are two leading candidates for dark matter that are plausibly detectable in terrestrial searches: axions and weakly-interacting massive particles, or WIMPs. Early NPAC investments supported PNNL involvement in the Axion Dark Matter eXperiment (ADMX), which has produced the world’s most sensitive axion search to date. Work associated with the current generation of the experiment is funded by the DOE Office of High Energy Physics (HEP), while R&D toward future searches for higher mass axions proceeds under NPAC. Likewise, early NPAC support for WIMP searches has graduated to the HEP-supported Super Cold Dark Matter Search (SuperCDMS) experiment. SuperCDMS has produced world-leading limits on potential WIMP candidates as well as a number of other exotic candidates and processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axion Dark Matter EXperiment 2A Cavity Characterization

The axion is a highly motivated dark matter candidate for its capacity to solve the strong CP problem in quantum chromodynamics. To detect the axion, the 2A phase of the Axion Dark Matter EXperiment (ADMX) utilizes four identical cylindrical resonant cavities that can detect the photons converted from axions in a strong magnetic field. We found the quality factors for various tunings in cavity D, and we also learned that the piezo motors are not currently equipped to handle cryogenic temperatures. However, the measured quality factors are much more promising than those shown in the last 2A cooldown, improving by about a factor of five.

Maglione, Diego↗

Axion Dark Matter Experiment Cavity Locking; System Development and Testing

This report documents the comparison of two frequency locking techniques for the four-cavity system under development for run 2A of the Axion Dark Matter eXperiment (ADMX). This report covers the requirements and technical challenges facing both of these techniques, a summary of tests performed at the University of Florida in late 2017 / early 2018 in order to compare them, and the final outcome and decision based on these tests and subsequent analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-mode Analysis of Surface Losses in a Superconducting Microwave Resonator in High Magnetic Fields

This paper reports on a surface impedance measurement of a niobium titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to $10\,{\rm T}$). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple $TM$ cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment (ADMX), because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.

43 PARTICLE ACCELERATORS↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105.This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

Axion Dark Matter EXperiment 2A Cavity Characterization

We cooled the ADMX 2A cavities down to 5K and found the Q-factors for various tunings, which were about a factor of five larger than the Q-factors from the previous cooldown. We also found that the tuning mechanism with the piezo motor and gearbox is not currently equipped to handle cryogenic temperatures. We created an experimental warm bead pull setup using piezo motors, an alumina bead, a pulley system, and a distance calibrating script. We found that the bead pull method can successfully show us the reflection-induced electric field mode structure. This technique allowed us to differentiate between different TE and TM modes near mode crossings. However, some bead pull sweeps produced noisy or asymmetrical results, possibly due to asymmetries in the tuning rod orientation or antenna. Future iterations of the bead pull method can help us estimate the cavity form factor and maximize our scan range near mode crossings.

Maglione, D.↗

Mechanical Actuation Mechanism Design for Cryogenic Microwave Cavities in Axion Dark Matter Searches

Resonant Microwave Cavities are placed in a strong magnetic field at cryogenic temperatures (~.1K) in order to try to convert axions into detectable photons. A major challenge is to tune the cavity to allow no interference with the desired environment used for the experiment, which enables the system to operate near absolute zero and maintain superconductivity, thereby reducing noise as much as possible. My project focuses on developing and testing a low-thermal-conductivity gear reduction system with a 1000:1 ratio for cavity tuning. This gear system could significantly improve the thermal and electromagnetic interference of the tuning mechanism, helping ADMX scan for axions more accurately.

Ortega, Giancarlo [Marquette U.; Fermilab]↗