Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ADMX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong 𝐶⁢𝑃 problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10 and 1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ADMX SLIC: Results from a Superconducting $\textit{LC}$ Circuit Investigating Cold Axions

Axions are a promising cold dark matter candidate. Haloscopes, which use the conversion of axions to photons in the presence of a magnetic field to detect axions, are the basis of microwave cavity searches such as the Axion Dark Matter eXperiment (ADMX). To search for lighter, low frequency axions in the sub-2 × 10 –7 eV (50 MHz) range, a tunable lumped-element $\textit{LC}$ circuit has been proposed. For the first time, through ADMX SLIC (Superconducting $\textit{LC}$ Circuit Investigating Cold Axions), a resonant $\textit{LC}$ circuit was used to probe this region of axion mass-coupling space. The detector used a superconducting $\textit{LC}$ circuit with piezoelectric driven capacitive tuning. The axion mass and corresponding frequency ranges 1.7498–1.7519 × 10 –7 eV (42.31–42.36 MHz), 1.7734–1.7738 × 10 –7 eV (42.88–42.89 MHz), and 1.8007–1.8015 × 10 –7 eV (43.54–43.56 MHz) were covered at magnetic fields of 4.5 T, 5.0 T, and 7.0 T, respectively. Exclusion results from the search data, for coupling below 10 –12 GeV –1 , are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cryogenic Gear System for ADMX Tuning Cavity

The Axion Dark Matter Experiment (ADMX) searches for axions by converting them into detectable photons using resonant microwave cavities at cryogenic temperatures. A precise tuning system is needed to adjust cavity frequency without adding thermal load or electromagnetic interference. This project developed and tested a 1000 to 1 gear reduction system made from PEEK, a low thermal conductivity plastic with good dimensional stability and self lubrication at low temperatures. A compound gear train design of five 3 to 1 stages and one 4 to 1 stage achieves high reduction within a 40 mm diameter compact housing. Prototypes were 3D printed and later CNC machined in PEEK using Fusion 360 and Bantam Tools to confirm manufacturability. Prototype testing showed smooth gear engagement and no slipping. The final gearbox improves cavity tuning precision for axion searches while protecting cryogenic conditions.

Ortega, Giancarlo [Marquette U.]↗

ADMX Axion Dark Matter Bounds around 3.3 μ eV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability

We report the results of a QCD axion dark matter search with discovery ability for Dine-Fischler-Srednicki-Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultralow noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 μ eV , assuming a standard halo model with a local energy density of 0.45 G e V / cm 3 made up 100% of axions. Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS↗

Axion dark matter experiment: Run 1B analysis details

Searching for axion dark matter, the ADMX Collaboration acquired data from January to October 2018, over the mass range 2.81–3.31 μeV, corresponding to the frequency range 680–790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 90% confidence level and 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for run 1B, motivating analysis choices informed by details specific to this run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnets are Weber Bar Gravitational Wave Detectors

When a gravitational wave (GW) passes through a dc magnetic field, it couples to the conducting wires carrying the currents which generate the magnetic field, causing them to oscillate at the GW frequency. The oscillating currents then generate an ac component through which the GW can be detected-thus forming a resonant mass detector or a nagnetic Weber bar. We quantify this claim and demonstrate that magnets can have exceptional sensitivity to GWs over a frequency range demarcated by the mechanical and electromagnetic resonant frequencies of the system; indeed, we outline why a magnetic readout strategy can be considered an optimal Weber bar design. The concept is applicable to a broad class of magnets, but can be particularly well exploited by the powerful magnets being deployed in search of axion dark matter, for example, by DMRadio and ADMX-EFR. Explicitly, we demonstrate that the MRI magnet that is being deployed for ADMX-EFR can achieve a broadband GW strain sensitivity of ∼10^{-20}/sqrt[Hz] from a few kHz to about 10 MHz, with a peak sensitivity down to ∼10^{-22}/sqrt[Hz] at a kHz exploiting a mechanical resonance.

Domcke, Valerie↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution Data Analysis: Plans and Prospects [Book Chapter]

Herein, a report on the progress on the high resolution data analysis of the ADMX experimental results is presented. In this paper, tools are developed and tested on a blind injection mimicking a Maxwellian like signal in the frequency domain. This blind injection will be used as a test bed which can be later implemented on all the high resolution data. The high resolution data is stored in the Fermilab server. In this analysis a PostgreSQL query was made to ensure the blind injection is in the middle of the frequency spectrum and 19 such files were found. The time series data is read using a c++ program. An apodization function is applied on the time series data and zero filled to reduce the frequency spacing in order to achieve a better interpolation. A FFTW header is used to compute the Fourier transform of the time series data. A Savitzky–Golay filter is applied on the unnormalized power which then can be used to remove the spectral shape. Each frequency spectrum has a bandwidth of 50 kHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic Axion Background detection using resonant cavity arrays

The axion is a well-motivated and generic extension of the Standard Model. If produced in the early universe, axions may still be relativistic today, forming a Cosmic Axion Background (CaB) potentially detectable in direct detection experiments. Although CaB is expected to be broadband, which makes it challenging to be detected, a high-quality-factor microwave cavity acts as a narrowband filter with response peaked at its resonant frequency. We propose a new strategy using multi-cavity arrays to distinguish signal from background noise by exploiting spatial correlations of the axion-induced electric field which are set by the cavity quality factor. We compute the two-point correlation function for electric fields in spatially separated cavities sourced by an isotropic CaB. Analyzing various cavity geometries, we find that stacked, wide-base cavity arrays offer coherent enhancement of the axion signal. We apply our formalism to prospective upgrades of the ADMX experiment, including configurations with four and eighteen coupled cavities. Although these arrays do not achieve a coherent enhancement, optimizing the geometry could potentially yield an $\mathcal{O}(1)$ improvement in the sensitivity to the CaB.

Axions and ALPs↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axion Dark Matter eXperiment: Run 1A analysis details

The ADMX Collaboration gathered data for its Run 1A axion dark matter search from January 2017 to June 2017, scanning with an axion haloscope over the frequency range 645–680 MHz ( 2.66 – 2.81 μ eV in axion mass) at Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) sensitivity. The resulting axion search found no axionlike signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonvirialized axion search sensitive to Doppler effects in the Milky Way halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki- Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. Here, we report the results of a non-virialized axion search over the mass range 2.81–3.31 µeV, corresponding to the frequency range 680–800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector’s motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of $\mathscr{O}$(10 -7 )c with 95% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗