Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “512-S”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

640 x 512 Pixels Long-Wavelength Infrared (LWIR) Quantum-Dot Infrared Photodetector (QDIP) Imaging Focal Plane Array

Epitaxially grown self-assembled. InAs-InGaAs-GaAs quantum dots (QDs) are exploited for the development of large-format long-wavelength infrared focal plane arrays (FPAs). The dot-in-a-well (DWELL) structures were experimentally shown to absorb both 45 degrees and normal incident light, therefore, a reflection grating structure was used to enhance the quantum efficiency. The devices exhibit peak responsivity out to 8.1 micrometers, with peak detectivity reaching approximately 1 X 10(exp 10) Jones at 77 K. The devices were fabricated into the first long-wavelength 640 x 512 pixel QD infrared photodetector imaging FPA, which has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60-K operating temperature.

quantum dots (QDs)↗

Principles of Neutron Scattering from Condensed Matter. By Andrew T. Boothroyd. Oxford University Press, 2020. Pp. 512. Price GBP 55.00. ISBN 9780198862314.

Neutron scattering user facilities are increasingly used by ‘non-expert’ users, opening neutron scattering to new science fields and greatly increasing the scientific impact of these facilities. This book aims to bring the needed introduction to the expanding area of neutron scattering techniques to this wider audience of scientists using neutron scattering as part of their experimental portfolio. In my opinion, it completely succeeds in that goal and provides the right balance of introduction and in-depth discussion. I also like the layout of the book, with some figures and notes in the margin making it easy to read and navigate. As a ‘long-time’ neutron scatterer, I am excited to add this book to my book shelf.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-512: Electromagnetic Simulations of the Dielectric Wall Accelerator

Purpose: To characterize and parametrically study the key components of a dielectric wall accelerator through electromagnetic modeling and particle tracking. Methods: Electromagnetic and particle tracking simulations were performed using a commercial code (CST Microwave Studio, CST Inc.) utilizing the finite integration technique. A dielectric wall accelerator consists of a series of stacked transmission lines sequentially fired in synchrony with an ion pulse. Numerous properties of the stacked transmission lines, including geometric, material, and electronic properties, were analyzed and varied in order to assess their impact on the transverse and axial electric fields. Additionally, stacks of transmission lines were simulated in order to quantify the parasitic effect observed in closely packed lines. Particle tracking simulations using the particle-in-cell method were performed on the various stacks to determine the impact of the above properties on the resultant phase space of the ions. Results: Examination of the simulation results show that novel geometries can shape the accelerating pulse in order to reduce the energy spread and increase the average energy of accelerated ions. Parasitic effects were quantified for various geometries and found to vary with distance from the end of the transmission line and along the beam axis. An optimal arrival time of an ion pulse relative to the triggering of the transmission lines for a given geometry was determined through parametric study. Benchmark simulations of single transmission lines agree well with published experimental results. Conclusion: This work characterized the behavior of the transmission lines used in a dielectric wall accelerator and used this information to improve them in novel ways. Utilizing novel geometries, we were able to improve the accelerating gradient and phase space of the accelerated particle bunch. Through simulation, we were able to discover and optimize design issues with the device at low cost. Funding: Morgridge Institute for Research, Madison WI; Conflict of Interest: Dr. Mackie is an investor and board member at CPAC, a company developing compact accelerator designs similar to those discussed in this work, but designs discussed are not directed by CPAC. Funding: Morgridge Institute for Research, Madison WI; Conflict of Interest: Dr. Mackie is an investor and board member at CPAC, a company developing compact accelerator designs similar to those discussed in this work, but designs discussed are not directed by CPAC.

43 PARTICLE ACCELERATORS↗

SU-E-T-512: Intrinsic Characteristics of the Nine Detectors and Evaluation of Their Performance in Non-Equilibrium Radiation Dosimetry

Purpose The aim for the study was to compare intrinsic characteristics of the nine detectors and evaluate their performance in non-equilibrium radiation dosimetry. Methods The intrinsic characteristics of the nine detectors that were evaluated are based on the composition and size of the active volume, operating voltage, initial recombination of the collected charge, temperature, the effective cross section of the detectors. The shortterm stability and collection efficiency has been investigated. The minimum radiation detection sensitivity and detectors leakage current has been measured. The sensitivity to changes in energy spectrum as well as change in incident beam angles were measured an analyzed. Results The short-term stability of the measurements within every detector showed consistency in the measured values with the highest value of the standard deviation of the mean not exceeding 0.5%. Air ion chamber detectors showed minimum sensitivity to change in incident beam angles while diode detectors underestimated measurements up to 16%. Comparing the slope of the tangents for detector’s sensitivity curve, diode detectors illustrate more sensitivity to change in photon spectrum than ion chamber detectors. The change in radiation detection sensitivity with increase in dose delivered has been observed for semiconductor detectors with maximum deviation 0.01% for doses between 1 Gy and 10 Gy. Leakage current has been mainly influenced by bias voltage (ion chamber detectors) and room light intensity (diode detectors). With dose per pulse varying from 1.47E−4 to 5.1E−4 Gy/pulse the maximum change in collection efficiency was 1.4% for the air ion chambers up to 8% for liquid filled ion chamber. Conclusion Broad range of measurements performed showed all the detectors susceptible to some limitations and while they are suitable for use in broad scope of applications, careful selection has to be made for particular range of measurements.

60 APPLIED LIFE SCIENCES↗

Analytic Framework for Optimal Sizing of Hydrogen Fueling Stations for Heavy Duty Vehicles at Ports (CRADA 512)

This CRADA presents the strategy that PNNL and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL) in properly sizing a hydrogen station for class 8 drayage trucks at the Port of Seattle (Port), as part of a coordinated plan of mixed uses for hydrogen. The proper sizing for the fueling station is unique from past experiences because it will be part of a coordinated plan for a multi-use scheme for the hydrogen, and not a stand-alone fueling station. The multiple use-streams, and their relative values, will impact all facets of station sizing and design, including fueling rates, storage technology and size, equipment selection, and safety considerations. The future deployment of this fueling station, and its proper sizing, is seen as a critical first step in the larger vision of utilizing hydrogen to address a range of issues for SCL and the Port. These include, but are not limited to, large scale fueling of medium duty (MD) and heavy duty (HD) vehicles to reduce emissions, support of adjacent light duty (LD) vehicles, support of critical port operation during extreme events (e.g. resiliency), mitigation of capital intensive electrical distribution system upgrades to support evolving port operations, a market resource that can be used by SCL to generate revenue, and support of planned future maritime operations that currently require heavy use of shipboard hydrogen. While the broader use of hydrogen by SCL and the Port is not the focus of this CRADA, how its use impacts the design of the initial vehicle fueling station, and the modular approach, are the central work. As such, this project will develop the framework and process for developing a modular station design that considers the broader range of coordinate uses of hydrogen as an energy resource.

08 HYDROGEN↗

Evaluation of ISDP Batch 2 Qualification Compliance to 512-S, DWPF, Tank Farm, and Saltstone Waste Acceptance Criteria

The purpose of this report is to document the acceptability of the second macrobatch (Salt Batch 2) of Tank 49H waste to H Tank Farm, DWPF, and Saltstone for operation of the Interim Salt Disposition Project (ISDP). Tank 49 feed meets the Waste Acceptance Criteria (WAC) requirements specified by References 11, 12, and 13. Salt Batch 2 material is qualified and ready to be processed through ARP/MCU to the final disposal facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Saturn 5 Launch Vehicle Flight Evaluation Report-AS-512 Apollo 17 Mission

An evaluation of the launch vehicle and lunar roving vehicle performance for the Apollo 17 flight is presented. The objective of the evaluation is to acquire, reduce, analyze, and report on flight data to the extent required to assure future mission success and vehicle reliability. Actual flight problems are identified, their causes are determined, and recommendations are made for corrective action. Summaries of launch operations and spacecraft performance are included. The significant events for all phases of the flight are analyzed.

Source record↗

The 512-channel correlator controller

A high-speed correlator for radio and radar observations was developed and a controller was designed so that the correlator could run automatically without computer intervention. The correlator controller assumes the role of bus master and keeps track of data and properly interrupts the computer at the end of the observation.

Brokl, S. S.↗

Radiation damage in a Tektronix 512 CCD

A Tektronix CCD was subjected to a proton beam. Comparisons were made of the CCD characteristics before, during, and after radiation. Gain and readout noise were not affected and charge transfer efficiency, full well, and dark current were. Permanent CTE damage resulted immediately upon radiation, but full well damage developed two days after radiation, while the dark current showed signs of recovery before permanent damage occurred. Histogram analysis showed that the most spiky-type behavior resulted from damage to defects existing in the CCD before radiation.

Brown, Larry W.↗

A 640 X 512-Pixel Portable Long-Wavelength Infrared Camera

A portable long-wavelength infrared electronic camera having a cutoff wavelength of 9 microns has been built around an image sensor in the form of a 640X512-pixel array of AlxGa(1-x)As/GaAs quantum-well infrared photodetectors (QWIPs). This camera is an intermediate product of a continuing program to develop high-resolution, high-sensitivity infrared cameras.

Gunapala, Sarath↗

Evaluation of no-MST operations in the SRS ARP for Hanford LAWPS

The Savannah River Site (SRS) Actinide Removal Process has been processing salt waste since 2008. This process includes a filtration step in the 512-S facility. Initial operations included the addition, or strike, of monosodium titanate (MST) to remove soluble actinides and strontium. The added MST and any entrained sludge solids were then separated from the supernate by cross flow filtration. During this time, the filter operations have, on many occasions, been the bottleneck process limiting the rate of salt processing. Recently, 512-S- has started operations utilizing “No-MST” where the MST actinide removal strike was not performed and the supernate was simply pre-filtered prior to Cs removal processing. Direct filtration of decanted tank supernate, as demonstrated in 512-S, is the proposed method of operation for the Hanford Low Activity Waste Pretreatment System (LAWPS) facility. Processing decanted supernate without MST solids has been demonstrated for cross flow filtration to provide a significant improvement in production with the SRS Salt Batches 8 and 9 feed chemistries. The average filtration rate for the first 512-S batch processing cycle using No-MST has increased filtrate production by over 35% of the historical average. The increase was sustained for more than double the amount of filtrate batches processed before cleaning of the filter was necessary. While there are differences in the design of the 512-S and Hanford filter systems, the 512-S system should provide a reasonable indication of LAWPS filter performance with similar feed properties. Based on the data from the 512-S facility and with favorable feed properties, the LAWPS filter, as currently sized at over twice the size of the 512-S filter (532 square feet filtration area versus 235 square feet), has the potential to provide sustained filtrate production at the upper range of the planned LAWPS production rate of 17 gpm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Operation of a Material Identification and Discrimination Imaging Spectroradiometer

Many imaging applications require quantitative determination of a scene's spectral radiance. This paper describes a new system capable of real-time spectroradiometric imagery. Operating at a full-spectrum update rate of 30Hz, this imager is capable of collecting a 30 point spectrum from each of three imaging heads: the first operates from 400 nm to 950 nm, with a 2% bandwidth; the second operates from 1.5 micro-m to 5.5 micro-m with a 1.5% bandwidth; the third operates from 5 micro-m to 12 micro-m, also at a 1.5% bandwidth. Standard image format is 256 x 256, with 512 x 512 possible in the VIS/NIR head. Spectra of up to 256 points are available at proportionately lower frame rates. In order to make such a tremendous amount of data more manageable, internal processing electronics perform four important operations on the spectral imagery data in real-time. First, all data in the spatial/spectral cube of data is spectro-radiometrically calibrated as it is collected. Second, to allow the imager to simulate sensors with arbitrary spectral response, any set of three spectral response functions may be loaded into the imager including delta functions to allow single wavelength viewing; the instrument then evaluates the integral of the product of the scene spectral radiances and the response function. Third, more powerful exploitation of the gathered spectral radiances can be effected by application of various spectral-matched filtering algorithms to identify pixels whose relative spectral radiance distribution matches a sought-after spectral radiance distribution, allowing materials-based identification and discrimination. Fourth, the instrument allows determination of spectral reflectance, surface temperature, and spectral emissivity, also in real-time. The spectral imaging technique used in the instrument allows tailoring of the frame rate and/or the spectral bandwidth to suit the scene radiance levels, i.e., frame rate can be reduced, or bandwidth increased to improve SNR when viewing low radiance scenes. The unique challenges of design and calibration are described. Pixel readout rates of 160 MHz, for full frame readout rates of 1000 Hz (512 x 512 image) present the first challenge; processing rates of nearly 600 million integer operations per second for sensor emulation, or over 2 billion per second for matched filtering, present the second. Spatial and spectral calibration of 66,536 pixels (262,144 for the 512 x 512 version) and up to 1,000 spectral positions mandate novel decoupling methods to keep the required calibration memory to a reasonable size. Large radiometric dynamic range also requires care to maintain precision operation with minimum memory size.

Dombrowski, Mark↗

Development of a 2K x 2K GaAs QWIP Focal Plane Array

We are developing the next generation of GaAs Quantum Well Infrared Photodetector (QWIP) focal plane arrays (FPAs) in preparation for future NASA space-borne Earth observing missions. It is anticipated that these missions will require both wider ground spatial coverage as well as higher ground imaging resolution. In order to demonstrate our capability in meeting these future goals we have taken a two-tiered approach in the next stage of advanced QWIP focal plane array development. We will describe our progress in the development of a 512 x 3,200 (512 x 3K) array format for this next generation thermal imaging array for the NASA Landsat project. However, there currently is no existing readout integrated circuit (ROIC) for this format array.so to demonstrate the ability to scale-up an existing ROIC we developed a 1,920 x 2,048 (2K x 2K) array and it hybridized to a Raytheon SB419 CTIA readout integrated circuit that was scaled up from their existing 512 x 640 SB339 ROIC. Two versions of the 512 x 3K QWIP array were fabricated to accommodate a future design scale-up of both the Indigo 9803 ROIC based on a 25 micron pixel dimension and a scale up of the Indigo 9705 ROIC based on a 30 micron pixel dimension. Neither readout for the 512 x 3K has yet to be developed but we have fabricated both versions of the array. We describe the design, development and test results of this effort as well as the specific applications these FPAs are intended to address.

Jhabvala, M.↗

A multi-frame, megahertz CCd imager

To record high-speed, explosively driven, events, a high efficiency, high speed, imager has been fabricated which is capable of framing rates of 2 MHz. This device utilizes a 512 x 512 pixel charge coupled device (CCD) with a 25cm{sup 2} active area, and incorporates an electronic shutter technology designed for back-illuminated CCD's, making this the largest and fastest back-illuminated CCD in the world. Characterizing an imager capable of this frame rate presents unique challenges. High speed LED drivers and intense radioactive sources are needed to perform the most basic measurements. We investigate properties normally associated with single-frame CCD's such as read noise, full-well capacity, sensitivity, signal to noise ratio, linearity and dynamic range. In addition, we investigate several properties associated with the imager's multi-frame operation such as transient frame response and frame-to-frame isolation while contrasting our measurement techniques and results with more conventional devices.

47 OTHER INSTRUMENTATION↗

Fast DRR generation for 2D to 3D registration on GPUs

Purpose: The generation of digitally reconstructed radiographs (DRRs) is the most time consuming step on the CPU in intensity based two-dimensional x-ray to three-dimensional (CT or 3D rotational x-ray) medical image registration, which has application in several image guided interventions. This work presents optimized DRR rendering on graphical processor units (GPUs) and compares performance achievable on four commercially available devices. Methods: A ray-cast based DRR rendering was implemented for a 512 Multiplication-Sign 512 Multiplication-Sign 72 CT volume. The block size parameter was optimized for four different GPUs for a region of interest (ROI) of 400 Multiplication-Sign 225 pixels with different sampling ratios (1.1%-9.1% and 100%). Performance was statistically evaluated and compared for the four GPUs. The method and the block size dependence were validated on the latest GPU for several parameter settings with a public gold standard dataset (512 Multiplication-Sign 512 Multiplication-Sign 825 CT) for registration purposes. Results: Depending on the GPU, the full ROI is rendered in 2.7-5.2 ms. If sampling ratio of 1.1%-9.1% is applied, execution time is in the range of 0.3-7.3 ms. On all GPUs, the mean of the execution time increased linearly with respect to the number of pixels if sampling was used. Conclusions: The presented results outperform other results from the literature. This indicates that automatic 2D to 3D registration, which typically requires a couple of hundred DRR renderings to converge, can be performed quasi on-line, in less than a second or depending on the application and hardware in less than a couple of seconds. Accordingly, a whole new field of applications is opened for image guided interventions, where the registration is continuously performed to match the real-time x-ray.

07 ISOTOPE AND RADIATION SOURCES↗

Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector

Purpose: The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. Methods: A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60 irradiator to achieve either a uniform dose or a 2-level “step-dose” pattern. Results: With 6% refractive index mismatching, a circular field of view of 85% of the diameter of a cylindrical sample can be reconstructed accurately. Reconstructed images of the test solution phantom were uniform (within 3%) inside this radius. However, the dose responses of the PRESAGE® samples were not spatially uniform, with variations of at least 5% in sensitivity. The variation appears as a “cupping” artifact with less sensitivity in the middle than at the periphery of the PRESAGE® cylinder. Polarization effects were also detected for these samples. Conclusions: The fiducial-based ray path measurement scheme, coupled with an iterative reconstruction algorithm, enabled optical CT scanning of PRESAGE® dosimeters immersed in mismatched refractive index solutions. However, improvements to PRESAGE® dose response uniformity are required.

60 APPLIED LIFE SCIENCES↗

Breath-Hold Target Localization With Simultaneous Kilovoltage/Megavoltage Cone-Beam Computed Tomography and Fast Reconstruction

Purpose: Hypofractionated high-dose radiotherapy for small lung tumors has typically been based on stereotaxy. Cone-beam computed tomography and breath-hold techniques have provided a noninvasive basis for precise cranial and extracranial patient positioning. The cone-beam computed tomography acquisition time of 60 s, however, is beyond the breath-hold capacity of patients, resulting in respiratory motion artifacts. By combining megavoltage (MV) and kilovoltage (kV) photon sources (mounted perpendicularly on the linear accelerator) and accelerating the gantry rotation to the allowed limit, the data acquisition time could be reduced to 15 s. Methods and Materials: An Elekta Synergy 6-MV linear accelerator, with iViewGT as the MV- and XVI as the kV-imaging device, was used with a Catphan phantom and an anthropomorphic thorax phantom. Both image sources performed continuous image acquisition, passing an angle interval of 90{sup o} within 15 s. For reconstruction, filtered back projection on a graphics processor unit was used. It reconstructed 100 projections acquired to a 512 x 512 x 512 volume within 6 s. Results: The resolution in the Catphan phantom (CTP528 high-resolution module) was 3 lines/cm. The spatial accuracy was within 2-3 mm. The diameters of different tumor shapes in the thorax phantom were determined within an accuracy of 1.6 mm. The signal-to-noise ratio was 68% less than that with a 180{sup o}-kV scan. The dose generated to acquire the MV frames accumulated to 82.5 mGy, and the kV contribution was <6 mGy. Conclusion: The present results have shown that fast breath-hold, on-line volume imaging with a linear accelerator using simultaneous kV-MV cone-beam computed tomography is promising and can potentially be used for image-guided radiotherapy for lung cancer patients in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sample variance in N-body simulations and impact on tomographic shear predictions

We study the effects of sample variance in N-body simulations as a function of the size of the simulation box, namely in connection with predictions on tomographic shear spectra. We make use of a set of eight ΛCDM simulations in boxes of 128, 256, and 512 h{sup −1} Mpc a side, for a total of 24, differing just by the initial seeds. Among the simulations with 128 and 512 h{sup −1} Mpc a side, we suitably select those closest and farthest from average. Numerical and linear spectra P(k,z) are suitably connected at low k to evaluate the effects of sample variance on shear spectra C{sub ij}(ℓ) for 5 or 10 tomographic bands. We find that shear spectra obtained by using 128 h{sup −1} Mpc simulations can vary up to ∼25%, just because of the seed. The sample variance lowers to ∼3.3% when using 512 h{sup −1} Mpc. These percentages could however slightly vary if other sets of the same number of realizations were considered. Accordingly, in order to match the ∼1% precision expected for the data, if still using eight boxes, we require a size of ∼1300–1700 h{sup −1} Mpc for them.

79 ASTRONOMY AND ASTROPHYSICS↗