Evaluation of Performance, Fatigue and Workload During Real-time, Reactive Telerobotic Mission Control Operations

Real-time, reactive telerobotic mission control operations require personnel to actively operate and manage remotely controlled vehicles or robots in real time. Due to the physical separation of the vehicle from the operator, such operations present many additional factors that can influence fatigue (i.e., degraded mental performance) and workload (i.e., mental and physical cost of task requirements), making it difficult to assess how long an individual can safely and accurately conduct operations. The upcoming Volatiles Investigating Polar Exploration Rover (VIPER) mission involves remotely controlling a lunar vehicle from an Earth-based mission control station. METHODS: In order to determine how long personnel could successfully maintain alertness and performance while operating a rover, we studied seven trained operators (i.e., 5 drivers, 2 real-time scientists) in a simulated mission control environment. We further assessed workload in order to determine whether perceived workload levels would change relative to time on task and by time of day. Operators completed two five-hour simulations in a randomized order, beginning at noon and at midnight. Performance was evaluated every 30 minutes using the psychomotor vigilance task (PVT), Karolinska Sleepiness Scale (KSS), and NASA Task Load Index (NASA-TLX). RESULTS: On average, participants rated themselves as sleepier (5.06 ± 2.28) on the night drives compared to the day drives (3.12 ± 1.44; P < .0001). Workload was rated higher during the day drives (37.93 ± 20.09) compared to night (32.09 ± 21.74; P < .01). Lastly, participants had no change in average reaction time between the two drives. CONCLUSIONS: From the analysis, we observed performance began to degrade after approximately three hours of driving. Our findings suggest that rotating drivers at least every three hours would be prudent to allow for breaks, and to minimize performance degradation, particularly during night shifts.

fatigue↗

Overview of Space Telerobotics

This chapter discusses the need for space teleoperators and robots, here generically called telerobots, and describes the basic elements of such systems as well as their current capabilities, limitations and need technical improvements.

space↗

Demonstration of A High-Fidelity Predictive/Preview Display Technique for Telerobotic Servicing in Space

A highly effective predictive/preview display technique for telerobotic servicing in space under several seconds communication time delay has been demonstrated on a large laboratory scale in May, 1993, involving the Jet Propulsion Laboratory as the simulated ground control station and, 2500 miles away, the Goddard Space Flight Center as the simulated satellite servicing set-up. The technique isbased on a high-fidelity calibration procedure that enables a high-fidelity overlay of 3-D graphics robot arm and object models over given 2-D TV camera images of robot arm and objects. Togenerate robot arm motions, the operator can confidently interact in real time with the graphics models of the robot arm and objects overlaid on an actual camera view of the remote work site. The technique also enables the operator to generate high-fidelity synthetic TV camera views showing motion events that are hidden in a given TV camera view or for which no TV camera views are available...

Bejczy, A. K.↗

Haptic device for telerobotic surgery

A haptic device for telerobotic surgery, including a base; a linkage system having first and second linkage members coupled to the base; a motor that provides a motor force; a transmission including first and second driving pulleys arranged such that their faces form an angle and their axes form a plane, first and second idler pulleys offset from the plane and arranged between the first and second driving pulleys such that their axes divide the angle between the first and second driving pulleys, and a cable that traverses the first and second driving pulleys and the set of idler pulleys and transfers the motor force to the linkage system; an end effector coupled to distal ends of the first and second linkage members and maneuverable relative to the base; and a controller that modulates the motor force to simulate a body part at a point portion of the end effector.

42 ENGINEERING↗

Telerobotics for Microsurgery

None given. Covers recent advances in robotics and their applicaiton to microsurgery.

telerobotics robotics medicine surgery robot assis↗

Telerobotic controller development

To meet NASA's space station's needs and growth, a modular and generic approach to robotic control which provides near-term implementation with low development cost and capability for growth into more autonomous systems was developed. The method uses a vision based robotic controller and compliant hand integrated with the Remote Manipulator System arm on the Orbiter. A description of the hardware and its system integration is presented.

Otaguro, W. S.↗

Sensing and perception research for space telerobotics at JPL

PIFLEX is a pipelined-image processor that can perform elaborate computations whose exact nature is not fixed in the hardware, and that can handle multiple images. A wire-wrapped prototype PIFEX module has been produced and debugged, using a version of the convolver composed of three custom VLSI chips (plus the line buffers). A printed circuit layout is being designed for use with a single-chip convolver, leading to production of a PIFEX with about 120 modules. A high-level language for programming PIFEX has been designed, and a compiler will be written for it. The camera calibration software has been completed and tested. Two more terms in the camera model, for lens distortion, probably will be added later. The acquisition and tracking system has been designed and most of it has been coded in Pascal for the MicroVAX-II. The feature tracker, motion stereo module and stereo matcher have executed successfully. The model matcher is still under development, and coding has begun on the tracking initializer. The object tracker was running on a different computer from the VAX, and preliminary runs on real images have been performed there. Once all modules are working, optimization and integration will begin. Finally, when a sufficiently large PIFEX is available, appropriate parts of acquisition and tracking, including much of the feature tracker, will be programmed into PIFEX, thus increasing the speed and robustness of the system.

Gennery, Donald B.↗

Dynamic evaluation of a traction-drive joint for space telerobots

Presented is an analysis and evaluation of a prototype traction-drive joint for robotic manipulators, developed under NASA sponsorship. A dynamic model is developed using the Lagrange formulation. Controllability, observability, dynamic stability, and response characteristics of the joint to test inputs are studied. A linear quadratic regulator (LQR) is implemented on the joint model to determine a basis for evaluating the performance of the traction-drive joint under servo control. An evaluation of the results and directions for future investigations are presented.

Desilva, Clarence W.↗

A telerobotic system for automated assembly of large space structures

Future space missions such as polar platforms and antennas are anticipated to require large truss structures as their primary support system. During the past several years considerable research has been conducted to develop hardware and construction techniques suitable for astronaut assembly of truss structures in space. A research program has recently been initiated to develop the technology and to demonstrate the potential for automated in-space assembly of large erectable structures. The initial effort will be focussed on automated assembly of a tetrahedral truss composed of 2-meter members. The facility is designed as a ground based system to permit evaluation of assembly concepts and was not designed for space qualification. The system is intended to be used as a tool from which more sophisticated procedures and operations can be developed. The facility description includes a truss structure, motionbases and a robot arm equipped with an end effector. Other considerations and requirements of the structural assembly describe computer control systems to monitor and control the operations of the assembly facility.

Rhodes, Marvin D.↗

Traction-drive force transmission for telerobotic joints

A mechanism which meets the requirements of a teleoperated manipulator and those of an autonomous robot is discussed. The mechanism is a traction-drive differential that uses variable preload mechanisms. The differential provides compact design, with dextrous motion range and torque density similar to geared systems. The traction drive offers high stiffness to backlash for good robotic performance. The variable-loading mechanism (VLM) minimizes the drive-train friction for improved teleoperation. This combination provides a mechanism to allow advanced manipulation with either teleoperated control or autonomous robotic operation. The design principles of both major components of the joint mechanism are described.

Williams, D. M.↗

Shuttle bay telerobotics demonstration

A demonstration of NASA's robotics capabilities should be a balanced agenda of servicing and assembly tasks combined with selected key technical experiments. The servicing tasks include refueling and module replacement. Refueling involves the mating of special fluid connectors while module replacement requires an array of robotic technologies such as special tools, the arm of a logistics tool, and the precision mating of orbital replacement units to guides. The assembly task involves the construction of a space station node and truss structure. The technological experiments will focus on a few important issues: the precision manipulation of the arms by a teleoperator, the additional use of several mono camera views in conjunction with the stereo system, the use of a general purpose end effector versus a caddy of tools, and the dynamics involved with using a robot with a stabilizer.

Chun, W.↗

High gain feedback and telerobotic tracking

Asymptotically stable linear time invariant systems are capable of tracking arbitrary reference signals with a bounded error proportional to the magnitude of the reference signal (and its derivatives). It is shown that a similar property holds for a general class of nonlinear dynamical systems which includes all robots. As in the linear case, the error bound may be made arbitrarily small by increasing the magnitude of the feedback gains which stabilize the system.

Koditschek, D. E.↗

Cooperative control in telerobotics

It is argued that autonomous robotics is not yet feasible, and that instantaneous human control may be difficult because of communication delay and expensive because of labor costs. Therefore, it is argued, human supervisory control with cooperation between man and a partially autonomous distant robot is the most viable engineering solution. Model control of image processing enables efficient visual displays. Cooperative control in paired manipulators required rapid controller signal information to be passed over a cross-filter in a heuristic study.

Stark, Lawrence W.↗