Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Verification of Advective Bar Elements Implemented in the Aria Thermal Response Code.

A verification effort was undertaken to evaluate the implementation of the new advective bar capability in the Aria thermal response code. Several approaches to the verification process were taken : a mesh refinement study to demonstrate solution convergence in the fluid and the solid, visually examining the mapping of the advective bar element nodes to the surrounding surfaces, and a comparison of solutions produced using the advective bars for simple geometries with solutions from commercial CFD software . The mesh refinement study has shown solution convergence for simple pipe flow in both temperature and velocity . Guidelines were provided to achieve appropriate meshes between the advective bar elements and the surrounding volume. Simulations of pipe flow using advective bars elements in Aria have been compared to simulations using the commercial CFD software ANSYS Fluent (r) and provided comparable solutions in temperature and velocity supporting proper implementation of the new capability. Verification of Advective Bar Elements iv Acknowledgements A special thanks goes to Dean Dobranich for his guidance and expertise through all stages of this effort . His advice and feedback was instrumental to its completion. Thanks also goes to Sam Subia and Tolu Okusanya for helping to plan many of the verification activities performed in this document. Thank you to Sam, Justin Lamb and Victor Brunini for their assistance in resolving issues encountered with running the advective bar element model. Finally, thanks goes to Dean, Sam, and Adam Hetzler for reviewing the document and providing very valuable comments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Implementation of Radiation-Hydrodynamics Verification Test Problems

Analytic solutions to the radiation-hydrodynamic equations are useful for verifying any large-scale numerical simulation software that solves the same set of equations. The one-dimensional, spherically symmetric Coggeshall No.9 and No.11 analytic solutions, cell-averaged over a uniform-grid have been developed to analyze the corresponding solutions from the Los Alamos National Laboratory Eulerian Applications Project radiation-hydrodynamics code xRAGE. These Coggeshall solutions have been shown to be independent of heat conduction, providing a unique opportunity for comparison with xRAGE solutions with and without the heat conduction module. Solution convergence was analyzed based on radial step size. Since no shocks are involved in either problem and the solutions are smooth, second-order convergence was expected for both cases. The global L1 errors were used to estimate the convergence rates with and without the heat conduction module implemented.

97 MATHEMATICS AND COMPUTING↗

TH-AB-202-02: Real-Time Verification and Error Detection for MLC Tracking Deliveries Using An Electronic Portal Imaging Device

Purpose: The added complexity of the real-time adaptive multi-leaf collimator (MLC) tracking increases the likelihood of undetected MLC delivery errors. In this work we develop and test a system for real-time delivery verification and error detection for MLC tracking radiotherapy using an electronic portal imaging device (EPID). Methods: The delivery verification system relies on acquisition and real-time analysis of transit EPID image frames acquired at 8.41 fps. In-house software was developed to extract the MLC positions from each image frame. Three comparison metrics were used to verify the MLC positions in real-time: (1) field size, (2) field location and, (3) field shape. The delivery verification system was tested for 8 VMAT MLC tracking deliveries (4 prostate and 4 lung) where real patient target motion was reproduced using a Hexamotion motion stage and a Calypso system. Sensitivity and detection delay was quantified for various types of MLC and system errors. Results: For both the prostate and lung test deliveries the MLC-defined field size was measured with an accuracy of 1.25 cm{sup 2} (1 SD). The field location was measured with an accuracy of 0.6 mm and 0.8 mm (1 SD) for lung and prostate respectively. Field location errors (i.e. tracking in wrong direction) with a magnitude of 3 mm were detected within 0.4 s of occurrence in the X direction and 0.8 s in the Y direction. Systematic MLC gap errors were detected as small as 3 mm. The method was not found to be sensitive to random MLC errors and individual MLC calibration errors up to 5 mm. Conclusion: EPID imaging may be used for independent real-time verification of MLC trajectories during MLC tracking deliveries. Thresholds have been determined for error detection and the system has been shown to be sensitive to a range of delivery errors.

60 APPLIED LIFE SCIENCES↗

New developments and verification of fusion blanket simulation capabilities in the MOOSE framework

Multiphysics modeling capabilities have a crucial role to play in the accelerated deployment of fusion energy. To that end, we developed new multiphysics fusion blanket simulation capabilities in the Multiphysics Object-Oriented Simulation Environment (MOOSE). Firstly, we expanded on the existing capabilities of the previously published work, by coupling 3D tritium transport modeling capabilities using the Tritium Migration Analysis Program, version 8 (TMAP8) to an existing tool including thermal hydraulics, fully three-dimensional (3D) heat transfer, and loosely coupled neutronics analysis. Secondly, we performed a thorough verification of the new capabilities and increased testing code coverage to meet MOOSE’s software quality standards. The MOOSE framework follows a strict software quality assurance plan to be Nuclear Quality Assurance, Level 1 compliant. The new multiphysics fusion blanket simulation capabilities are now held to the same standard. Thirdly, to demonstrate MOOSE’s new fusion blanket modeling capabilities, we performed a fully integrated, multiphysics simulation of a 3D solid ceramic breeder blanket design. This proof-of-concept simulation provides the temperature and tritium distribution across the blanket. In conclusion, the combined efforts towards software quality and the development of multiphysics coupling capabilities provide an effective and reliable framework for modeling solid ceramic fusion blankets using MOOSE.

modeling and simulation↗

National Rotor Testbed Requirements. Draft

This document serves both as a guide and a record for requirements management associated with design of retrofit rotors for the Sandia SWiFT turbines. The rotors will support a long-term experimental campaign. Data gathered during the campaign will support formal verification and validation of complex flow numerical models for prediction of metrics deemed important for wind energy plant efficiency. These integrated projects involve multiple years of effort, dozens of engineers and collaborators, and dozens of stakeholders in the form of the research community, National Lab staff, and DOE staff. Creating of formal, written requirements will ensure flow-down of activities from high-level goals, aid communication, and enable clear verification of activities. A custom requirements schema is created and described. Commercial requirements management software —IBM Rational DOORS—is used to organize the information and ensure traceability. This document serves as a record of the process as well as a record of the exported, detailed contents of the DOORS database.

17 WIND ENERGY↗

Examining Autonomous Inspection of Geologic Repositories

Geological repositories for nuclear waste, including spent nuclear fuel, present a significant challenge for traditional International Atomic Energy Agency (IAEA) safeguards tools due to their inaccessibility and demanding operational conditions. The IAEA has been working closely with Member State organizations currently involved in repository construction and planning including Euratom, the Finnish and Swedish regulatory authorities, and relevant facility operators. However, the verification challenge remains unsolved, and there persists an out-standing need for tools and approaches that will help the IAEA verify that no nuclear material is diverted from a repository environment. The challenge is also not static as activities must encompass verification of the design prior to and during the construction/operation phase, and post backfill. Throughout these various phases, it is imperative that the IAEA maintains a continuity of knowledge (CoK) of all material, including information on material inventory and flow. This paper highlights these challenges and outlines how they might be addressed by using remote or autonomous vehicles. Specifically, it discusses the current state of the art in robotic autonomy for known or partially known environment mapping and patrolling, as well as shared autonomy, where humans collaborate with closed loop autonomation to complete tasks. The feasibility of using rovers for these verification tasks is explored, along with the challenges associated with system implementation. Hardware and software suggestions are provided based on the adoption of similar technologies in other comparable areas and ability to close technical gaps. Finally, human-robotic interactions are considered based on the challenges of the environment of the repository and effective deployment and continued operation of the robot system

autonomous monitoring↗

Experiment Automation with a Robot Arm using the Liquids Reflectometer Instrument at the Spallation Neutron Source

The Liquids Reflectometer instrument installed at the Spallation Neutron Source (SNS) enables observations of chemical kinetics, solid-state reactions and phase-transitions of thin film materials at both solid and liquid surfaces. Effective measurement of these behaviors requires each sample to be calibrated dynamically using the neutron beam and the data acquisition system in a feedback loop. Since the SNS is an intense neutron source, the time needed to perform the measurement can be the same as the alignment process, leading to a labor-intensive operation that is exhausting to users. An update to the instrument control system, completed in March 2013, implemented the key features of automated sample alignment and robot-driven sample management, allowing for unattended operation over extended periods, lasting as long as 20 hours. We present a case study of the effort, detailing the mechanical, electrical and software modifications that were made as well as the lessons learned during the integration, verification and testing process.

automated alignment↗

Development and Assessment of CTF for Pin-resolved BWR Modeling

CTF is the modernized and improved version of the subchannel code, COBRA-TF. It has been adopted by the Consortium for Advanced Simulation for Light Water Reactors (CASL) for subchannel analysis applications and thermal hydraulic feedback calculations in the Virtual Environment for Reactor Applications Core Simulator (VERA-CS). CTF is now jointly developed by Oak Ridge National Laboratory and North Carolina State University. Until now, CTF has been used for pressurized water reactor modeling and simulation in CASL, but in the future it will be extended to boiling water reactor designs. This required development activities to integrate the code into the VERA-CS workflow and to make it more ecient for full-core, pin resolved simulations. Additionally, there is a significant emphasis on producing high quality tools that follow a regimented software quality assurance plan in CASL. Part of this plan involves performing validation and verification assessments on the code that are easily repeatable and tied to specific code versions. This work has resulted in the CTF validation and verification matrix being expanded to include several two-phase flow experiments, including the General Electric 3 3 facility and the BWR Full-Size Fine Mesh Bundle Tests (BFBT). Comparisons with both experimental databases is reasonable, but the BFBT analysis reveals a tendency of CTF to overpredict void, especially in the slug flow regime. The execution of these tests is fully automated, analysis is documented in the CTF Validation and Verification manual, and the tests have become part of CASL continuous regression testing system. This paper will summarize these recent developments and some of the two-phase assessments that have been performed on CTF.

Salko, Robert K↗

Evaluating Security Controls Based on Key Performance Indicators and Stakeholder Mission

Good security metrics are required to make good decisions about how to design security countermeasures, to choose between alternative security architectures, and to improve security during operations. Therefore, in essence, measurement can be viewed as a decision aid. The lack of sound practical security metrics is severely hampering progress in the development of secure systems. The Cyberspace Security Econometrics System (CSES) offers the following advantages over traditional measurement systems: (1) CSES reflects the variances that exist amongst different stakeholders of the same system. Different stakeholders will typically attach different stakes to the same requirement or service (e.g., a service may be provided by an information technology system or process control system, etc.). (2) For a given stakeholder, CSES reflects the variance that may exist among the stakes she/he attaches to meeting each requirement. The same stakeholder may attach different stakes to satisfying different requirements within the overall system specification. (3) For a given compound specification (e.g., combination(s) of commercial off the shelf software and/or hardware), CSES reflects the variance that may exist amongst the levels of verification and validation (i.e., certification) performed on components of the specification. The certification activity may produce higher levels of assurance across different components of the specification than others. Consequently, this paper introduces the basis, objectives and capabilities for the CSES including inputs/outputs and the basic structural and mathematical underpinnings.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-218: Validation of An In-Vivo Proton Range Verification Method for Reducing the Risk of Permanent Alopecia in the Treatment of Pediatric Medulloblastoma

Purpose: The clinical commissioning of a workflow for pre-treatment range verification/adjustment for the head treatment of pediatric medulloblastoma patients, including dose monitoring during treatment. Methods: An array of Si-diodes (DIODES Incorporated) is placed on the patient skin on the opposite side to the beam entrance. A “scout” SOBP beam, with a longer beam range to cover the diodes in its plateau, is delivered; the measured signal is analyzed and the extracted water equivalent path lengths (WEPL) are compared to the expected values, revealing if a range correction is needed. Diodes stay in place during treatment to measure dose. The workflow was tested in solid water and head phantoms and validated against independent WEPL measurements. Both measured WEPL and skin doses were compared to computed values from the TPS (XiO); a Markus chamber was used for reference dose measurements. Results: The WEPL accuracy of the method was verified by comparing it with the dose extinction method. It resulted, for both solid water and head phantom, in the sub-millimeter range, with a deviation less than 1% to the value extracted from the TPS. The accuracy of dose measurements in the fall-off part of the dose profile was validated against the Markus chamber. The entire range verification workflow was successfully tested for the mock-treatment of head phantom with the standard delivery of 90 cGy per field per fraction. The WEPL measurement revealed no need for range correction. The dose measurements agreed to better than 4% with the prescription dose. The robustness of the method and workflow, including detector array, hardware set and software functions, was successfully stress-tested with multiple repetitions. Conclusion: The performance of the in-vivo range verification system and related workflow meet the clinical requirements in terms of the needed WEPL accuracy for pretreatment range verification with acceptable dose to the patient.

60 APPLIED LIFE SCIENCES↗

Incorporation of Multi-Member Substructure Capabilities in FAST for Analysis of Offshore Wind Turbines: Preprint

FAST, developed by the National Renewable Energy Laboratory (NREL), is an aero-hydro-servo-elastic tool widely used for analyzing onshore and offshore wind turbines. This paper discusses recent modifications made to FAST to enable the examination of offshore wind turbines with fixed-bottom, multi-member support structures (which are commonly used in transitional-depth waters). ; This paperaddresses the methods used for incorporating the hydrostatic and hydrodynamic loading on multi-member structures in FAST through its hydronamic loading module, HydroDyn. Modeling of the hydrodynamic loads was accomplished through the incorporation of Morison and buoyancy loads on the support structures. Issues addressed include how to model loads at the joints of intersecting members and ontapered and tilted members of the support structure. Three example structures are modeled to test and verify the solutions generated by the modifications to HydroDyn, including a monopile, tripod, and jacket structure. Verification is achieved through comparison of the results to a computational fluid dynamics (CFD)-derived solution using the commercial software tool STAR-CCM+.

17 WIND ENERGY↗

A Runtime Verification Framework for Control System Simulation

n a standard workflow for the validation of a control system, the control system is implemented as an extension to a simulator. Such simulators are complex software systems, and engineers may unknowingly violate constraints a simulator places on extensions. As such, errors may be introduced in the implementation of either the control system or the simulator leading to invalid simulation results. This paper presents a novel runtime verification approach for verifying control system implementations within simulators. The major contribution of the approach is the two-tier specification process. In the first tier, engineers model constraints using a domain-specific language tailored to modeling a controller’s response to changes in its input. The language is high-level and effectively hides the implementation details of the simulator, allowing engineers to specify design-level constraints independent of low-level simulator interfaces. In the second tier, simulator developers provide mapping rules for mapping design-level constraints to the implementation of the simulator. Using the rules, an automated tool transforms the design-level specifications into simulator-specific runtime verification specifications and generates monitoring code which is injected into the implementation of the simulator. During simulation, these monitors observe the input and output variables of the control system and report changes to the verifier. The verifier checks whether these changes follow the constraints of the control system. We describe application of this approach to the verification of the constraints of an HVAC control system implemented with the power grid simulator GridLAB-D.

control system↗

Preparatory Verification of a New Monte Carlo Code cosRMC based on VERA Core Physics Benchmark

To promote nuclear power plant system design and simulation software self-reliance development, DOE of China approved a R and D key project to develop an integrated engine for pressurized water reactor core and system design and analysis, referred as COSINE hereafter. The scope of this code package includes reactor physics, thermal hydraulics, safety analysis, severe accidents, probability safety assessment and etc. Many universities, research institutes and nuclear related corporations in China are involved in the code development, among which the State Nuclear Power Software Development Center (SNPSDC) plays the leading role. With the requirement of accurate three-dimensional modeling of the advanced, special or new complex core in reactor neutronics and shielding analysis, Monte Carlo method is becoming a more powerful tool for reactor analysis. Thus, a new Monte Carlo transport code named cosRMC (abbreviation for COSINE Reactor Monte Carlo) has been developed jointly by SNPSDC and Department of Engineering Physics, Tsinghua University, the main developer of RMC code. The cosRMC now has many functions as criticality calculation, fixed-source calculation, burnup calculation, and etc. Some techniques for geometry treatment, new burnup algorithm, source convergence acceleration, massive tally and parallel calculation have been implemented in cosRMC to improve the efficiency. In order to ensure its reliability, several types of V and V work have been and are being carried out for cosRMC. In this paper, some preparatory verification results based on VERA Core Physics Benchmark are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using Process Load Cell Information for IAEA Safeguards at Enrichment Plants

Uranium enrichment service providers are expanding existing enrichment plants and constructing new facilities to meet demands resulting from the shutdown of gaseous diffusion plants, the completion of the U.S.-Russia highly enriched uranium downblending program, and the projected global renaissance in nuclear power. The International Atomic Energy Agency (IAEA) conducts verification inspections at safeguarded facilities to provide assurance that signatory States comply with their treaty obligations to use nuclear materials only for peaceful purposes. Continuous, unattended monitoring of load cells in UF{sub 6} feed/withdrawal stations can provide safeguards-relevant process information to make existing safeguards approaches more efficient and effective and enable novel safeguards concepts such as information-driven inspections. The IAEA has indicated that process load cell monitoring will play a central role in future safeguards approaches for large-scale gas centrifuge enrichment plants. This presentation will discuss previous work and future plans related to continuous load cell monitoring, including: (1) algorithms for automated analysis of load cell data, including filtering methods to determine significant weights and eliminate irrelevant impulses; (2) development of metrics for declaration verification and off-normal operation detection ('cylinder counting,' near-real-time mass balancing, F/P/T ratios, etc.); (3) requirements to specify what potentially sensitive data is safeguards relevant, at what point the IAEA gains on-site custody of the data, and what portion of that data can be transmitted off-site; (4) authentication, secure on-site storage, and secure transmission of load cell data; (5) data processing and remote monitoring schemes to control access to sensitive and proprietary information; (6) integration of process load cell data in a layered safeguards approach with cross-check verification; (7) process mock-ups constructed to provide simulated load cell data; (8) hardware and software implementation for process load cell data collection; (9) costs associated with unattended monitoring of load cells (for both operator and inspector) weighed against the potential benefits of having access to such data; (10) results from field tests of load cell data collection systems in operating facilities; and (11) use of unattended load cell data to increase efficiency of on-site inspection schedules and activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-815: In Vivo Dosimetry and Daily Arc Junction Verification Using EBT3 Gafchromic Film for Pediatric Cranio-Spinal Irradiation

Purpose: Perform dosimetric comparison between planned and delivered dose in the junction area, measure daily dose variation in the arc junction area for pediatric patients treated for medulloblastoma using Craniospinal axis irradiation(CSI) Material and methods Dose comparison in the junction area, daily dose variation in the arc junction area for a Rando Phantom and 5 pediatric patients treated using CSI technique were analyzed. Plans were created using the Eclipse treatment planning system. Two arcs for cranium and 1 arc for spine region were used. Planar dose matrix was created by projecting phantom and patient plan into the ArcCheck phantom. EBT3 film was placed in the middle of ArcCheck plug to measure dose distribution in the junction areaDuring patient treatment, strip of EBT3 film was placed daily at each junction area for verification. EBT3 films were scanned using a flatbed scanner, Epson Expression 10000 XL. Film QA pro software was used to analyze film. Scanning and analysis was performed according to vendor recommendations and AAPM TG-55 report. Films were scanned and analyzed daily after each treatment and at the end of treatment course. Planar dose distributions from films were compared with planar dose distribution from treatment planning system. Results: Comparison of planned vs. measured dose distributions for patients have passing rates of 90%–100% with 3% and 3 mm gamma analysis. In some of the treatment fractions, daily setup film showed variation in dose distribution in the junction area. Conclusion: It is critical to measure dose distribution in the arc junction area and use additional quality assurance measures to verify daily setup for CSI patient where one or more junctions are present. EBT3 film prove to be a good tool to achieve this task considering flexibility associated with the film such as symmetry, self-developing and ease of use.

60 APPLIED LIFE SCIENCES↗

Requirements Description of DASSH-F

This report reviews the modeling and simulation capabilities of Argonne National Laboratory’s DASSH code that is used in present reactor analysis activities. These capabilities will be used to establish the set of verification tasks necessary to verify DASSH for use on commercial projects. A similar approach was taken for the PERSENT, REBUS and DIF3D software packages. The DASSH program is a thermal analysis code designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. DASSH is a follow-on development to the SE2-ANL software and SUPERENERGY-2 software that it is based upon. DASSH was designed to account for both neutron and gamma heating and is inherently connected to the GAMSOR part of the ARC suite of fast reactor analysis software. SE2-ANL is a developed piece of software from the 1980s while DASSH is a modern implementation with notable improvements in geometry handling. The most important upgrade of DASSH relative to SE2-ANL is that it can analyze multiple time points in a single run where SE2-ANL can only treat a single time point. This allows the user to understand the impact of and search the flow distribution for the entire operational period of a reactor design considering pressure drop, peak coolant and fuel temperatures, and thermal striping. DASSH has three input paths that have to be verified. The first input path builds the geometry and power distribution based upon the DIF3D model but ignores the gamma heating aspects of the problem. The second input path also builds the geometry from the DIF3D model but it takes the neutron and gamma heating distributions from GAMSOR. The third input path is to take the geometry and power distribution directly from user input (i.e. not coupled to DIF3D or GAMSOR). DASSH also has many built in correlations for material properties along with a user defined specification of the fuel, structure, and coolant properties. There are correlations for flow split, mixing, pressure drop, and heat transfer coefficients (subchannel rather than a direct methodology). In total, verification of DASSH will require an extensive testing to cover all possible user features of the software.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WE-D-BRA-04: Online 3D EPID-Based Dose Verification for Optimum Patient Safety

Purpose: To develop an online 3D dose verification tool based on EPID transit dosimetry to ensure optimum patient safety in radiotherapy treatments. Methods: A new software package was developed which processes EPID portal images online using a back-projection algorithm for the 3D dose reconstruction. The package processes portal images faster than the acquisition rate of the portal imager (∼ 2.5 fps). After a portal image is acquired, the software seeks for “hot spots” in the reconstructed 3D dose distribution. A hot spot is in this study defined as a 4 cm{sup 3} cube where the average cumulative reconstructed dose exceeds the average total planned dose by at least 20% and 50 cGy. If a hot spot is detected, an alert is generated resulting in a linac halt. The software has been tested by irradiating an Alderson phantom after introducing various types of serious delivery errors. Results: In our first experiment the Alderson phantom was irradiated with two arcs from a 6 MV VMAT H&N treatment having a large leaf position error or a large monitor unit error. For both arcs and both errors the linac was halted before dose delivery was completed. When no error was introduced, the linac was not halted. The complete processing of a single portal frame, including hot spot detection, takes about 220 ms on a dual hexacore Intel Xeon 25 X5650 CPU at 2.66 GHz. Conclusion: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for various kinds of gross delivery errors. The detection of hot spots was proven to be effective for the timely detection of these errors. Current work is focused on hot spot detection criteria for various treatment sites and the introduction of a clinical pilot program with online verification of hypo-fractionated (lung) treatments.

60 APPLIED LIFE SCIENCES↗