Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quartz”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Stable cycling of high-mass loaded MnO 2 electrodes for sodium-ion batteries

Achieving cost-effective, sustainable solutions for large-scale energy storage are critical for advancing the global clean energy transition. In view of the challenges posed by limited lithium reserves, low-cost sodium-ion batteries (SIBs) have emerged as a promising direction, especially for grid-level energy storage. Among the various battery electrode materials, manganese dioxide (MnO 2 ) stands out as a favorable choice for such large-scale applications due to its earth abundance, cost-effectiveness, and non-toxic nature. Although MnO 2 is known as a pseudocapacitive material with superior cycling stability in aqueous electrolytes, its dissolution in non-aqueous electrolytes has restricted its use in long-lifetime batteries. In this study, we address two issues which have limited the use of MnO 2 electrodes in non-aqueous electrolytes. First, using electrochemical quartz crystal microbalance measurements in combination with other electrochemical methods, we demonstrate that diglyme (bis(2-methoxyethyl) ether) electrolyte can achieve stable cycling of electrodeposited ε-MnO 2 . These results enable us to tackle a second objective, that is increasing the mass loading of the MnO 2 electrode, since achieving high areal energy density is a significant factor in reducing manufacturing costs. Using 3D printed graphene aerogel (GA) as a scaffold, our studies show that the electrodeposited MnO 2 /GA electrodes possess scalable properties with mass loadings from 20 to 80 mg cm −2 . The resulting electrodes exhibit areal energy densities as high as 4.4 mA h cm −2 at a current density of 10 mA cm −2 . The high mass loaded MnO 2 electrodes were incorporated as a cathode in a SIB which used TiO 2 as the anode. The SIB device exhibited excellent performance with power densities in excess of 70 mW cm −2 . These studies highlight the promise of MnO 2 electrodes for use in a low-cost technology for large-scale energy storage.

25 ENERGY STORAGE↗

Investigation of electrode passivation during oxidation of a nitroxide radical relevant for flow battery applications

Nitroxide-radicals such as 2,2,6,6-tetramethylpiperidin-1-oxyl (TEMPO) and their derivatives have gained interest as redox-active organic molecules for applications in grid-scale energy storage. In particular, the higher solubility of 4-hydroxy-TEMPO in aqueous media greatly improves its energy density, but unusual kinetics associated with its surface-mediated electrooxidation have limited further development. Here, the apparent passivation behavior of species formed during 4-hydroxy-TEMPO electrooxidation in concentrated electrolytes is investigated. A combination of surface microscopy, X-ray photoelectron spectroscopy, and quartz-crystal gravimetry confirms the formation of a polymeric-type layer over the electrode surface composed of 4-hydroxy-TEMPO-like subunits, which is otherwise not observed with TEMPO. This study indicates that the design of high energy density and stable TEMPO-based redox molecules must also consider the reactivity that may occur due to the molecular characteristics of solubility-enhancing moieties. It is found that the extent of passivation is dependent on the voltage scan rate and 4-hydroxy-TEMPO concentration, underscoring the importance of studying materials at conditions relevant for their proposed applications. Evidence of incomplete passivation and an electrode self-cleaning process is presented, suggesting a materials design strategy to mitigate surface passivation from side reactions that may occur in redox active materials for energy storage applications.

Buchanan, Cailin [Argonne National Laboratory (ANL↗

Mixed-anion electrolytes: from bulk speciation to interfacial dynamics in divalent metal electrodeposition

Mixing anions is emerging as a promising strategy for multivalent electrolyte design, allowing for adjustment of the solvation structure of bulk cations and enhancing the efficiency of electrochemical processes (e.g. metal deposition for batteries and catalysis). Further progress in electrolyte development requires a fundamental understanding of how tailored electrolyte speciation in mixed anion systems can modify the dynamic electrochemical interface during metal cycling. In this study, we present an anode-focused mechanistic study of exemplar Mg electrolytes containing three different secondary anions, correlating electrochemical behavior with bulk speciation and operando interfacial dynamics. Electrospray Ionization-Mass Spectrometry (ESI-MS) results reveal a general trend of forming mixed anion contact ion pairs (CIPs) across various anions, with the extent of ion pairing influenced by the association strength of the secondary anion. Operando multiharmonic electrochemical quartz crystal microbalance with dissipation (EQCM-D) reveals how these bulk species influence interfacial mass uptake, viscoelasticity, and solvent-coupled hydrodynamic behavior during deposition and stripping. The results indicate that Mg-containing ion pairs and solvated complexes shape adsorption, nucleation, and deposit growth, leading to distinct anion-dependent interphases ranging from more permeable, solvent-coupled layers to relatively compact and rigid deposits. This work establishes a quantitative link between bulk speciation and interfacial dynamics in divalent metal electrodeposition and provides mechanistic guidance for electrolyte design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multi-wavelength streaked optical pyrometer for dynamic shock compression measurements above 2500 K

This work presents a concept and implementation of a calibrated streaked spectral pyrometer (SSP) temperature diagnostic used in dynamically driven shock experiments on a two-stage gas gun. This system relies upon measuring the total system response using a tunable monochromator, a NIST-traceable calibrated power meter, and a SSP. The diagnostic performance is validated against previously measured temperatures of shock driven z-cut quartz at 99 GPa and 93 GPa. The results are found to agree with the literature to within 5% and are discussed in this manuscript. The experimental setup utilizes measurements from multiple SSP systems per sample, providing several independent measurements and substantially increasing confidence in the extrapolated shock driven sample temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A microchip microcontroller-based transducer controller for non-contact scanning probe microscopy with phase-locked loop, amplitude, and Q control

An inexpensive yet versatile transducer controller for non-contact scanning probe microscopy (SPM) based on a PIC32 microcontroller from Microchip Technology, Inc is described. In addition to feedback control using the amplitude or phase of the signal from the non-contact transducer, the controller includes a phase-locked loop for frequency-shift feedback, as well as fixed-amplitude, quality factor (Q) control, and self-excitation modes. Apart from the input amplifiers, output buffers, and the Q-control circuit, all other functions of the controller are instantiated in software on the microchip, enabling rapid changes in operating parameters if needed. The controller communicates with a host personal computer via a simple serial connection. The controller has been tested with a quartz tuning-fork transducer but can be used with any oscillating non-contact transducer.

47 OTHER INSTRUMENTATION↗

High-precision shock equation of state measurements for metallic fluid carbon between 15 and 20 Mbar

Diamond is an efficient ablator material to convert the energy of high-power giant lasers into ablation pressure with applications for High-Energy-Density (HED) science, planetary science, and Inertial Confinement Fusion (ICF) research at the National Ignition Facility (NIF). Unfortunately, current theoretical equation of state models cannot reproduce all the observed experimental data in the multi-megabar regime particularly relevant for HED and ICF research. New experimental data on the behavior of carbon at extreme pressures and temperatures are, therefore, essential to improve our predictive capability to design and analyze dynamic compression experiments for HED or ICF research and build improved equation of state models in the future. In this paper, we report high-precision laser-driven shock compression measurements on diamond single crystals at the Omega Laser Facility. Using ultrafast Doppler optical Velocimetry Interferometer System for Any Reflector (VISAR) to track the leading shock front and a quartz plate as an in situ reference, we obtain relative pressure-density shock equation-of-state measurements between 15 and 20 Mbar with an impedance-matching procedure. We also report shock-and-release measurements in a spherical geometry at the NIF. The new data provide tight constraints on the compressibility of warm dense carbon along the Hugoniot of full density diamond, allowing us to discriminate between existing theoretical equation-of-state models. We find that both LLNL LEOS 9061 and LANL Sesame 7835 models capture well the shock compressibility in the explored range. LANL Sesame 7835 also reproduces well the observed shock-and-release behavior of diamond near 10–20 Mbar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ionization wave propagation in a He plasma jet in a controlled gas environment

Characterizing ionization wave propagation in low temperature plasma jets is critical to predicting production of reactive species and plasma–surface interactions for biomedical applications and surface functionalization. In this work, results from optical emission and laser induced fluorescence measurements of the ionization wave in a He plasma jet operating in a controlled gas environment are discussed and used for comparison with numerical modeling. Additionally, the ionization wave was observed using ICCD (Intensified Charge Coupled Device) imaging and characterized by time and spatially resolved electron density measurements using laser-collision-induced fluorescence. The plasma jet was initially characterized using pure He (nominally at 200 Torr), while varying pressure and voltage. When operating in pure He, the ionization wave broadly expands exiting the plasma tube. Increasing the operating pressure reduces the speed and isotropic expansion of the ionization wave. Furthermore, the jet operated with a humid He shroud was also studied. The humid He shroud results in the electron density increasing and having an annular profile due to the lower ionization potential of H2O compared to He and localized photoionization in the mixing region. Numerical modeling highlighted the importance of resonance radiation emitted by excited states of He, photoelectron emission from the quartz tube, and the kinetic behavior of the electrons produced by photoionization ahead of the ionization front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detailed diffraction imaging of x-ray optics crystals with synchrotron radiation

Rocking curve topography at the Advanced Photon Source’s beamline 1-BM measures the x-ray reflection from large (many cm 2 ) flat crystals on a sub-mm scale with microradian angular resolution. The $(01\bar{1}1)$ reflection at 8 keV is uniform across the crystal and close to theory for three thick quartz wafers well-polished with increasingly finer grit. However, the reflection is non-uniform for some ~ 0.1mmthin, bendable crystals that are made flat by optical contact with a flat substrate. Here, these thin crystals are bent to serve in certain x-ray diagnostics of plasmas, and similar non-uniformities could then occur in bent crystals as well. The same detail in x-ray reflection in bent crystals is unachievable with the existing topography setup: one way to get the desired resolution is with a standard microfocusing approach.

47 OTHER INSTRUMENTATION↗

Improved imaging using Mn He- α x rays at OMEGA EP

In this paper, we report on a crystal based x-ray imaging system fielded at the OMEGA EP laser facility. This new system has a pointing accuracy of +/100 μm, a temporal resolution down to 100 ps (depending on backlighter characteristics), variable magnification, and a spatial resolution of 21.9 µm at the object plane at a magnification of 15×. The system is designed to use a crystal along the crystal plane that satisfies the Bragg condition for the x ray of interest. The thin crystal is then bent into a spherical geometry and attached to a glass backing substrate to hold it in the diagnostic, and the x rays are imaged onto a charge coupled device. We report on data acquired with the new Los Alamos National Laboratory supplied spherical quartz crystal to image the Mn He-α 6.15 keV line emission.

Fiedler Kawaguchi, C. (ORCID:0000000175522370)↗

Quasiparticle electronic structure of phthalocyanine:TMD interfaces from first-principles GW

Interfaces formed between monolayer transition metal dichalcogenides and (metallo)phthalocyanine molecules are promising in energy applications and provide a platform for studying mixed-dimensional molecule-semiconductor heterostructures in general. An accurate characterization of the frontier energy level alignment at these interfaces is key in the fundamental understanding of the charge transfer dynamics between the two photon absorbers. Here, we employ the first-principles substrate screening GW approach to quantitatively characterize the quasiparticle electronic structure of a series of interfaces: metal-free phthalocyanine (H 2 Pc) adsorbed on monolayer MX 2 (M = Mo, W; X = S, Se) and zinc phthalocyanine (ZnPc) adsorbed on MoX 2 (X = S, Se). Furthermore, we reveal the dielectric screening effect of the commonly used α-quartz (SiO 2 ) substrate on the H 2 Pc:MoS 2 interface using the dielectric embedding GW approach. Our calculations furnish a systematic set of GW results for these interfaces, providing the structure–property relationship across a series of similar systems and benchmarks for future experimental and theoretical studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Vacuum Cherenkov Detector (VCD) for γ-ray measurements in inertial confinement fusion experiments

Inertial confinement fusion experiments at both the National Ignition Facility (NIF) and the Laboratory for Laser Energetics OMEGA laser facility currently utilize Cherenkov detectors, with fused silica as the Cherenkov medium. At the NIF, the Quartz Cherenkov Detectors improve the precision of neutron time-of-flight measurements; and at OMEGA, the Diagnostic for Areal Density provides measurements of capsule shell areal densities. An inherent property of fused silica is the radiator’s relatively low energy threshold for Cherenkov photon production (E threshold < 1 MeV), making it advantageous over gas-based Cherenkov detectors for experiments requiring low-energy γ detection. The Vacuum Cherenkov Detector (VCD) has been specifically designed for efficient detection of low energy γ’s. Its primary use is in implosion experiments, which will study reactions relevant to stellar and big-bang nucleosynthesis, such as T( 4 He,γ) 7 Li, 4 He( 3 He,γ) 7 Be, and 12 C(p,γ) 13 N. Further, the VCD is compatible with LLE’s standard Ten-Inch Manipulator diagnostic insertion module. This work will outline the design and characterization of the VCD as well as provide results from recent experiments conducted at the OMEGA laser facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility

The Imaging Spectroscopy Snout (ISS) used at the National Ignition Facility is able to simultaneously collect neutron pinhole images, 1D spatially resolved x-ray spectra, and time resolved x-ray pinhole images. To measure the x-ray spectra, the ISS can be equipped with up to four different transmission crystals, each offering different energy ranges from ∼7.5 to ∼12 keV and different resolutions. Characterizing and calibrating such instruments is of paramount importance in order to extract meaningful results from experiments. More specifically, we characterized different ISS transmission-type alpha-Quartz crystals by measuring their responses as a function of photon energy, from which we inferred the angle-integrated reflectivity for each crystal’s working reflections. These measurements were made at the Lawrence Livermore National Laboratory calibration station dedicated to the characterization of x-ray spectrometers. The sources used covered a wide x-ray range—from a few to 30 keV; the source diameter was ∼0.6 mm. The experimental results are discussed alongside theoretical calculations using the pyTTE model.

Dozieres, M. (ORCID:0000000286401459)↗

Shocked silica aerogel radiance transition

Silica (SiO 2 ) aerogel is widely used in high-energy-density shock experiments due to its low and adjustable density. Reported here are measurements of the shock velocity, optical radiance, and reflectivity of shocked SiO 2 aerogel with initial densities of 0.1, 0.2, and 0.3 g/cm 3 . These results are compared with similar data from three solid polymorphs of SiO 2 , silica, quartz, and stishovite with initial densities 2.2, 2.65, and 4.3 g/cm 3 , respectively. Interestingly, below a brightness temperature of T bright ≈ 35,000 K, the slope of the radiance vs shock velocity is the same for each of the SiO 2 aerogels and solid polymorphs. At T bright ≈ 35000 K, there is an abrupt change in the radiance vs shock velocity slope for aerogels, but not seen in the solid polymorphs over the pressures and temperatures explored here. An empirical model of shock front radiance as a function of SiO 2 density and laser drive parameters is reported to aid in the design of experiments requiring maximum shock front radiance.

42 ENGINEERING↗

Three-dimensional full-field velocity measurements in shock compression experiments using stereo digital image correlation

Shock compression plate impact experiments conventionally rely on point-wise velocimetry measurements based on laser-based interferometric techniques. This study presents an experimental methodology to measure the free surface full-field particle velocity in shock compression experiments using high-speed imaging and three-dimensional (3D) digital image correlation (DIC). The experimental setup has a temporal resolution of 100 ns with a spatial resolution varying from 90 to 200 μm/pixel. Experiments were conducted under three different plate impact configurations to measure spatially resolved free surface velocity and validate the experimental technique. First, a normal impact experiment was conducted on polycarbonate to measure the macroscopic full-field normal free surface velocity. Second, an isentropic compression experiment on Y-cut quartz–tungsten carbide assembly is performed to measure the particle velocity for experiments involving ramp compression waves. To explore the capability of the technique in multiaxial loading conditions, a pressure shear plate impact experiment was conducted to measure both the normal and transverse free surface velocities under combined normal and shear loading. The velocities measured in the experiments using digital image correlation are validated against previous data obtained from laser interferometry. Numerical simulations were also performed using established material models to compare and validate the experimental velocity profiles for these different impact configurations. The novel ability of the employed experimental setup to measure full-field free surface velocities with high spatial resolutions in shock compression experiments is demonstrated for the first time in this work.

47 OTHER INSTRUMENTATION↗

Heat capacity of microgram oxide samples by fast scanning calorimetry

Quantitative scanning calorimetry on microgram-sized samples opens a broad, new range of opportunities for studying the thermodynamic properties of quantity-limited materials, including those produced under extreme conditions or found as rare accessory minerals in nature. We calibrated the Mettler Toledo Flash DSC 2+ calorimeter to obtain quantitative heat capacities in the range 200–350 °C, using samples weighing between 2 and 11.5 μg. Our technique is applied to a new set of oxide materials to which it has never been used before, without the need for melting, glass transitions, or phase transformations. Heat capacity data were obtained for silica in the high pressure stishovite (rutile) structure, dense post-stishovite glass, standard fused quartz, and for TiO2 rutile. These heat capacities agree within 5%–15% with the literature values reported for rutile, stishovite, and fused SiO2 glass. The heat capacity of post-stishovite glass, made by heating stishovite to 1000 °C, is a newly reported value. After accurate calibrations, measured heat capacities were then used to calculate masses for samples in the microgram range, a substantial improvement over measurement in conventional microbalances, which have uncertainties approaching 50%–100% for such small samples. Since the typical uncertainty of heat capacities measured on 10–100 mg samples in conventional differential scanning calorimetry is typically 7% (1%–5% with careful work), flash differential scanning calorimetry, using samples a factor of 1000 smaller, increases the uncertainty of heat capacity measurements by a factor of <3, opening the door for meaningful measurements on ultra-small, high-pressure samples and other quantity-limited materials.

Instruments & Instrumentation↗

Developing compact tuning fork thermometers for sub-mK temperatures and high magnetic fields

There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. Here, we present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3 He and adapt hydrodynamic models to provide an improved description of temperature dependence in the high viscosity regime between 1 and 10mK. We demonstrate successful thermometer operation and discuss the feasibility of fast and compact thermal probes suitable for small samples.

47 OTHER INSTRUMENTATION↗

Plasma production and ion heating systems for the Material Plasma Exposure eXperiment

Plasma production and ion heating in the Material Plasma Exposure eXperiment (MPEX), whose design is nearing completion, is accomplished using continuous wave RF power with average power density up to 1.6 MW/m2 at the plasma interface. Plasma is produced using helicon waves coupled through a single helical antenna at 13.56 MHz with power supplied by three 100 kW fixed-frequency RF generators feeding a power combiner network followed by the matching network and launcher. The helicon source can utilize various gasses including hydrogen, deuterium, and helium, with a magnetic field strength in the source region up to 0.2 T, and maximum device |B| of 2.5 T. Power is coupled to ions via ion cyclotron heating at the fundamental resonance using a pair of phased helical antennas operating in the frequency range 4-9 MHz, that launch waves towards the resonance from the antenna region where ω > ωci. ICH power is supplied by a single 500 kW tunable RF transmitter through a 90° power splitter and matching/decoupling network. In the case of both the helicon and ICH systems the antennas are located external to the vacuum, with power transferred through novel water-cooled coaxial vacuum windows consisting of fused quartz outer cylinders and silicon nitride inner cylinders with forced convection water cooling between them. The antenna enclosures are pressurized with dry air to 3 bar absolute for voltage standoff.Several 3-D COMSOL models have been created to simulate the two systems. A model of the helicon region utilizing a cold plasma dielectric tensor with accurate magnetic field and realistic plasma density profiles has been used to calculate the plasma loading/complex antenna input impedance at the launcher feed for various ne and |B| values, for the purpose of estimating power handling. It also incorporates the geometry of all launcher structures relevant to this determination. A still more detailed model of the launcher together with a lossy dielectric plasma surrogate has been used to determine RF electric field values and power losses in the device components.Similar models have been produced to predict the performance and power handling of the ICH launcher. For this device the impedance matrix of the two-element antenna array is calculated using a warm plasma model, necessary to properly determine the wave propagation and absorption.

Goulding, Richard↗

Silicon implantation and annealing in β -Ga 2 O 3 : Role of ambient, temperature, and time

Optimizing thermal anneals of Si-implanted β-Ga 2 O 3 is critical for low resistance contacts and selective area doping. Here we report the impact of annealing ambient, temperature, and time on the activation of room temperature ion-implanted Si in β-Ga 2 O 3 at concentrations from 5 × 10 18 to 1 × 10 20 cm −3 , demonstrating full activation (>80% activation, mobilities >70 cm 2 /V s) with contact resistances below 0.29 Ω mm. Homoepitaxial β-Ga 2 O 3 films, grown by plasma-assisted molecular beam epitaxy on Fe-doped (010) substrates, were implanted at multiple energies to yield 100 nm box profiles of 5 × 10 18 , 5 × 10 19, and 1 × 10 20 cm −3 . Anneals were performed in an ultra-high vacuum-compatible quartz furnace at 1 bar with well-controlled gas compositions. To maintain β-Ga 2 O 3 stability, p O2 must be greater than 10 −9 bar. Anneals up to p O2 = 1 bar achieve full activation at 5 × 10 18 cm −3, while 5 × 10 19 cm −3 must be annealed with p O2 ≤ 10 −4 bar, and 1 × 10 20 cm −3 requires p O2 < 10 −6 bar. Water vapor prevents activation and must be maintained below 10 −8 bar. Activation is achieved for anneal temperatures as low as 850 °C with mobility increasing with anneal temperatures up to 1050 °C, though Si diffusion has been reported above 950 °C. At 950 °C, activation is maximized between 5 and 20 min with longer times resulting in decreased carrier activation (over-annealing). This over-annealing is significant for concentrations above 5 × 10 19 cm −3 and occurs rapidly at 1 × 10 20 cm −3 . Rutherford backscattering spectrometry (channeling) suggests that damage recovery is seeded from remnant aligned β-Ga 2 O 3 that remains after implantation; this conclusion is also supported by scanning transmission electron microscopy showing retention of the β-phase with inclusions that resemble the γ-phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗