Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Portable Tank Storage Pit Technical Documents and Associated Flooring Documents

The work performed under this section includes the surface preparation and application of protective floor coatings; furnishing all labor, materials, and equipment necessary to perform all operations in connection with the application required for satisfactory completion in accordance with the standards and practices set forth herein.

99 GENERAL AND MISCELLANEOUS↗

Introducing Kynema, an Open-Source Performance-Portable Flexible-Multibody-Dynamics Solver

In this talk we introduce Kynema, an open-source general flexible-multibody-dynamics solver that is well suited for simulating wind turbine structural dynamics. Kynema uses a Lie-group time integrator for constrained systems and runs on both CPUs and GPUs. Timing results for simulations are presented for the IEA 15-MW turbine with and without aerodynamic forces.

17 WIND ENERGY↗

Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science Addendum

Activation detectors developed at LLNL for measuring real-time neutron fluence from fusion sources are used in the broader fusion community. The recommended fluence operating range of this diagnostic is 5x10 2 – 1x10 6 n/cm2. The upper limit on this fluence range is set by the dead time caused by data transfer between the detector and data acquisition computer. Delaying the start of counting is a possible strategy to operate these detectors in higher fluences.

42 ENGINEERING↗

Developments in Performance and Portability for MadGraph5_aMC@NLO

Event generators simulate particle interactions using Monte Carlo techniques, providing the primary connection between experiment and theory in experimental high energy physics. These software packages, which are the first step in the simulation worflow of collider experiments, represent approximately 5 to 20% of the annual WLCG usage for the ATLAS and CMS experiments. With computing architectures becoming more heterogeneous, it is important to ensure that these key software frameworks can be run on future systems, large and small. In this contribution, recent progress on porting and speeding up the Madgraph5_aMC@NLO event generator on hybrid architectures, i.e. CPU with GPU accelerators, is discussed. The main focus of this work has been in the calculation of scattering amplitudes and "matrix elements", which is the computational bottleneck of an event generation application. For physics processes limited to QCD leading order, the code generation toolkit has been expanded to produce matrix element calculations using C++ vector instructions on CPUs and using CUDA for NVidia GPUs, as well as using Alpaka, Kokkos and SYCL for multiple CPU and GPU architectures. Performance is reported in terms of matrix element calculations per time on NVidia, Intel, and AMD devices. The status and outlook for the integration of this work into a production release usable by the LHC experiments, with the same functionalities and very similar user interfaces as the current Fortran version, is also described.

Valassi, Andrea↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Performance-portable Binary Neutron Star Mergers with AthenaK

We introduce an extension to the AthenaK code for general-relativistic magnetohydrodynamics (GRMHD) in dynamical spacetimes using a 3+1 conservative Eulerian formulation. Like the fixed-spacetime GRMHD solver, we use standard finite-volume methods to evolve the fluid and a constrained-transport scheme to preserve the divergence-free constraint for the magnetic field. We also utilize a first-order flux correction (FOFC) scheme to reduce the need for an artificial atmosphere and optionally enforce a maximum principle to improve robustness. We demonstrate the accuracy of AthenaK using a set of standard tests in flat and curved spacetimes. Using a SANE accretion disk around a Kerr black hole, we compare the new solver to the existing solver for stationary spacetimes using the so-called "HARM-like" formulation. We find that both formulations converge to similar results. We also include the first published binary neutron star (BNS) mergers performed on graphical processing units (GPUs). Thanks to the FOFC scheme, our BNS mergers maintain a relative error of $\mathcal{O}$(10 –11 ) or better in baryon mass conservation up to collapse. Finally, we perform scaling tests of AthenaK on OLCF Frontier, where we show excellent weak scaling of ≥80% efficiency up to 32,768 GPUs and 74% up to 65,536 GPUs for a GRMHD problem in dynamical spacetimes with six levels of mesh refinement. AthenaK achieves an order-of-magnitude speedup using GPUs compared to CPUs, demonstrating that it is suitable for performing numerical relativity problems on modern exascale resources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficacy of a portable, moderate-resolution, fast-scanning differential mobility analyzer for ambient aerosol size distribution measurements

Abstract. Ambient aerosol size distributions obtained with a compact scanning mobility analyzer, the “Spider” differential mobility analyzer (DMA), are compared to those obtained with a conventional mobility analyzer, with specific attention to the effect of mobility resolution on the measured size distribution parameters. The Spider is a 12 cm diameter radial differential mobility analyzer that spans the 10–500 nm size range with 30 s mobility scans. It achieves its compact size by operating at a nominal mobility resolution R=3 (sheath flow = 0.9 L min−1; aerosol flow = 0.3 L min−1) in place of the higher ratio of sheath flow to aerosol flow commonly used. The question addressed here is whether the lower resolution is sufficient to capture key characteristics of ambient aerosol size distributions. The Spider, operated at R=3 with 30 s up- and downscans, was co-located with a TSI 3081 long-column mobility analyzer, operated at R=10 with a 360 s sampling duty cycle. Ambient aerosol data were collected over 26 consecutive days of continuous operation, in Pasadena, CA. Over the 17–500 nm size range, the two instruments exhibit excellent correlation in the total particle number concentrations and geometric mean diameters, with regression slopes of 1.13 and 1.00, respectively. Our results suggest that particle sizing at a lower resolution than typically employed may be sufficient to obtain key properties of ambient size distributions, at least for these two moments of the size distribution. Moreover, it enables better counting statistics, as the wider transfer function for a given aerosol flow rate results in a higher counting rate.

54 ENVIRONMENTAL SCIENCES↗