Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “passivation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a simple yet effective statistical parameters based passive islanding scheme. The proposed scheme relies only the voltage data, measured at the point of common coupling (PCC), and is comprised of three stages. The Stage-1 quickly computes what is termed as mean based coarse islanding detection (MID), Stage-2 computes the decaying DC detector (DDCD), and 3) finally, MID is used in conjunction with DDCD as per the statistical digital relay logic (SRDL) is devised in Stage-3 to distinguish between islanding events from non islanding events. Various tests are investigated on the Banshee's industrial Microgrid (MG), modelled in the Real Time Digital Simulator (RTDS), on the basis of the IEEE-1547, UL 1741 standards. The validation of the proposed islanding detection methodology (PIDM) in RTDS platform ensures the viability of the proposed scheme in practical systems. The test results reveal that the PIDM can detect islanding within 2 cycles, and results in a very small non detection zone (NDZ). Moreover, the scheme can very well be used for single-phase MG too as it relies only on the single phase voltage information.

anti-islanding protection↗

Impact of carrier wafer on etch rate, selectivity, morphology, and passivation during GaN plasma etching

The choice of carrier wafer was found to significantly influence etch rates, selectivity, and morphology in GaN micropillar etching in a Cl 2 -Ar high-density inductively coupled plasma. 7 × 7 mm 2 GaN on sapphire chips with a plasma-enhanced chemical vapor deposition SiO 2 hard mask was etched on top of 4-in. fused silica, silicon carbide, silicon, sapphire, aluminum nitride, and high purity aluminum carriers. Silicon and silicon carbide carriers reduced GaN:SiO 2 selectivity because incidental SiCl x and CCl x etch products from the carriers attack the SiO 2 mask. Aluminum nitride and high-purity aluminum carriers yielded the highest GaN:SiO 2 selectivities due to the deposition of Al-based etched by-products, while the highest GaN etch rate was achieved using the sapphire carrier since it was the most inert carrier and did not sink any Cl 2 . Overall, results indicate that SiO 2 and Al may be used as passivation materials during GaN etching, as vertical profiles were achieved when SiO 2 or Al is redeposited from the fused silica and aluminum carriers, respectively. Floor pitting, trenching, sidewall roughness, and faceting were all influenced by carrier wafer type and will be discussed.

36 MATERIALS SCIENCE↗

Development of Passive HC/NOx Trap Catalysts for Low Temperature Gasoline Applications

This project aimed to develop fundamental understanding of the chemistry of NO adsorption and reaction in Pd/zeolites so as to facilitate the rational design of passive NOx adsorber catalysts. The approach adopted combined both experimental and computational methods, which together allow a deeper understanding of the governing chemistry than the use of either method alone. The workflow began with Pd/H-CHA and Pd/H-BEA catalyst synthesis and characterization, in which the Si/Al ratio and Al siting were systematically varied. This was followed by catalyst evaluation using temperature-programed adsorption/desorption methods, as well as in situ spectroscopic measurements to probe the chemistry of NO adsorption. In parallel, the adsorption of NO and other relevant species (H 2 O, CO, HCs) was studied by means of quantum chemical calculations in order to rationalize the experimental data and provide additional insights. Catalyst aging studies were also performed with the aim of elucidating the mechanism of catalyst degradation. Finally, the insights gained in this project were applied to the preparation of an optimized HC/NOx adsorber catalyst, the performance of which was studied using exhaust gas from an engine dynamometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microdroplet Electrospray Localized Laser Printing and Sintering of Nanoparticles for Passivating, Carrier-Selective Contacts (Final Technical Report)

In this project, the team used a nanoparticle electrospray laser deposition (NELD) process developed at the University of Central Florida (UCF) to address current limitations of passivating, carrier-selective contact technologies for crystalline silicon (c-Si) photovoltaic (PV) cells. The NELD process was used to print low bulk line resistivity Ag contacts directly onto transparent conductive oxides (TCOs), like indium tin oxide (ITO), for hydrogenated amorphous silicon (a-Si:H) based c-Si heterojunction (SHJ) cells without any subsequent contact firing step needed.

14 SOLAR ENERGY↗

Conceptual Design of Passive Neutron Albedo Reactivity and Active Neutron Albedo Reactivity Instruments for Various Arrangements of Pebble Bed Reactor Pebbles

MCNP6 simulations were performed to assess the anticipated capability of the Passive Neutron Albedo Reactivity technique for nuclear safeguards measurements of irradiated pebble/pebbles. Two physical setups were examined. One with a single pebble of three different burnups and one with 27 pebbles in a cube. For all cases the sensitivity to removing all the fissile material was examined. For both of the physical setups, 4 assay cases were examined: (a) singles count rates for which the only source neutrons were the inherent neutrons in the fuel, (b) singles count rates again except this time two relatively weak AmLi sources were placed above and below the top central pebble and the combined effect of both neutron source terms were examined, (c) doubles count rates for which the only source neutrons were the inherent neutrons in the fuel, and (d) doubles count rates again except this time two relatively weak AmLi sources were placed above and below the top central pebble and the combined effect of both neutron source terms were examined. Finally, a few parameters such as Cd near the 3 He tubes were perturbed to see if the results could be improved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strong Local Passivity in Unconventional Scenarios: A New Protocol for Amplified Quantum Energy Teleportation

Quantum energy teleportation (QET) has been proposed to overcome the restrictions of strong local passivity (SLP) and to facilitate energy transfer in quantum systems. Traditionally, QET has only been considered under strict constraints, including the requirements that the initial state be the ground state of an interacting Hamiltonian, that Alice’s measurement commute with the interaction terms, and that entanglement be present. These constraints have significantly limited the broader applicability of QET protocols. In this work, we demonstrate that SLP can arise beyond these conventional constraints, establishing the necessity of QET in a wider range of scenarios for local energy extraction. This leads to a more flexible and generalized framework for QET. Furthermore, we introduce the concept of a “local effective Hamiltonian,” which eliminates the need for optimization techniques in determining Bob’s optimal energy extraction in QET protocols. As an additional advantage, the amount of energy that can be extracted using our new protocol is amplified to be 7.2 times higher than that of the original protocol. These advancements enhance our understanding of QET and extend its broader applications to quantum technologies. To support our findings, we implement the protocol on quantum hardware, confirming its theoretical validity and experimental feasibility.

amplified energy extraction↗

All-Ceramic Passive Wireless Temperature Sensor Realized by Tin-Doped Indium Oxide (ITO) Electrodes for Harsh Environment Applications

In this work, an all-ceramic passive wireless inductor–capacitor (LC) resonator was presented for stable temperature sensing up to 1200 °C in air. Instead of using conventional metallic electrodes, the LC resonators are modeled and fabricated with thermally stable and highly electroconductive ceramic oxide. The LC resonator was modeled in ANSYS HFSS to operate in a low-frequency region (50 MHz) within 50 × 50 mm geometry using the actual material properties of the circuit elements. The LC resonator was composed of a parallel plate capacitor coupled with a planar inductor deposited on an Al2O3 substrate using screen-printing, and the ceramic pattern was sintered at 1250 °C for 4 h in an ambient atmosphere. The sensitivity (average change in resonant frequency with respect to temperature) from 200–1200 °C was ~170 kHz/°C. The temperature-dependent electrical conductivity of the tin-doped indium oxide (ITO, 10% SnO2 doping) on the quality factor showed an increase of Qf from 36 to 43 between 200 °C and 1200 °C. The proposed ITO electrodes displayed improved sensitivity and quality factor at elevated temperatures, proving them to be an excellent candidate for temperature sensing in harsh environments. The microstructural analysis of the co-sintered LC resonator was performed using a scanning electron microscope (SEM) which showed that there are no cross-sectional and topographical defects after several thermal treatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wireless Passive Ceramic Sensor for Far-Field Temperature Measurement at High Temperatures

A passive wireless high-temperature sensor for far-field applications was developed for stable temperature sensing up to 1000 °C. The goal is to leverage the properties of electroceramic materials, including adequate electrical conductivity, high-temperature resilience, and chemical stability in harsh environments. Initial sensors were fabricated using Ag for operation to 600 °C to achieve a baseline understanding of temperature sensing principles using patch antenna designs. Fabrication then followed with higher temperature sensors made from (In, Sn) O2 (ITO) for evaluation up to 1000 °C. A patch antenna was modeled in ANSYS HFSS to operate in a high-frequency region (2.5–3.5 GHz) within a 50 × 50 mm2 confined geometric area using characteristic material properties. The sensor was fabricated on Al2O3 using screen printing methods and then sintered at 700 °C for Ag and 1200 °C for ITO in an ambient atmosphere. Sensors were evaluated at 600 °C for Ag and 1000 °C for ITO and analyzed at set interrogating distances up to 0.75 m using ultra-wideband slot antennas to collect scattering parameters. The sensitivity (average change in resonant frequency with respect to temperature) from 50 to 1000 °C was between 22 and 62 kHz/°C which decreased as interrogating distances reached 0.75 m.

47 OTHER INSTRUMENTATION↗

Fabrication of Poly-Si on Locally Etched SiOx as Passivating Contacts for c-Si Solar Cells

Proof-of-concept for polysilicon on locally etched oxide (PLEO) contacts. Room temperature approach (via MACE) to engineer pinholes decouples charge-carrier transport across contact from passivation scheme of choice. 19 and 17% PLEO devices fabricated on double-side textured and saw-damage etched n Cz wafers, respectively. Preliminary work on polysilicon on locally etched nitride/oxide (PLENO) contacts. 0.2 fA/cm2 achieved with p PLENO; contact displays Ohmic behavior but still very resistive due to low pinhole density.

c-Si↗

Loss Analysis and Performance Optimization Pathways of 729-mV VocSi Solar Cells with Poly-Si on Locally-Etched Dielectric Passivating Contacts

In this article, the performance analysis of a 22.5% efficient polysilicon on silicon oxide (poly-Si/SiOx) passivated contact solar cells with deliberately introduced pinholes using metal-assisted chemical etching (MACE) has been performed with the help of optical analysis using Sunsolve and electrical analysis using Quokka3. The power loss is maximum due to recombination and resistive losses in the bulk (~0.76 mW/cm2 ) followed by power loss due to rear contact recombination (~0.35 mW/cm2 ). Recombination at the front surface also contributes to 0.24 mW/cm2. The effect of improving the bulk lifetime and lowering the recombination current density at the rear side on Voc, FF and efficiency has been investigated.

MACE↗

Self-Assembled Monolayer Procedure to Pattern Silicon Passivated Contacts

We utilize hexamethyldisilazane (HMDS)-based self-assembled monolayers to pattern polysilicon (polySi) passivated contacts. We find process conditions that allow for etching frontside n/polySi between fingers, thereby increasing Jsc. Importantly, the Voc does not degrade indicating the additional process steps do not introduce defects or impurities. HMDS layers remain on the surface for metallization without detriment to transport.

hexamethyldisilazane↗

Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Silicon Carbide Passive Temperature Sensors at INL

Discuss the SiC passive thermometry methods currently performed at INL and ORNL, decide on best path forward for establishing an ASTM Standard for processing SiC temperature monitors, and expand this ASTM benchmarking efforts to international collaborators (Netherlands, Canada, and Poland).

36 MATERIALS SCIENCE↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗