Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mass movements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Lidar measurements of Mount St. Helens effluents

Lidar measurements of the worldwide movement of stratospheric aerosols produced by the 18 May 1980 eruption of Mount St. Helens are described. Ground-based and airborne measurements show that the layers below 20 km produced by this eruption moved in an easterly direction while those above 20 km moved in a westerly direction. The effluent at jet stream altitudes of 10 to 12 km circled the globe in about 16 days and the effluent at 23 km (the highest altitude recorded) circled the globe in about 56 days. Mass calculations, using backscatter-to-mass conversion models, indicate that approximately half a million metric tons of new stratospheric material were produced by this eruption. Even though this represents a 200% increase in Northern Hemispheric aerosol, no significant long-term atmospheric temperature change should occur.

Mccormick, M. P.↗

Development of a High Fidelity Dynamic Module of the Advanced Resistive Exercise Device (ARED) Using Adams

NASA's Digital Astronaut Project (DAP) implements well-vetted computational models to predict and assess spaceflight health and performance risks, and enhance countermeasure development. DAP provides expertise and computation tools to its research customers for model development, integration, or analysis. DAP is currently supporting the NASA Exercise Physiology and Countermeasures (ExPC) project by integrating their biomechanical models of specific exercise movements with dynamic models of the devices on which the exercises were performed. This presentation focuses on the development of a high fidelity dynamic module of the Advanced Resistive Exercise Device (ARED) on board the ISS. The ARED module, illustrated in the figure below, was developed using the Adams (MSC Santa Ana, California) simulation package. The Adams package provides the capabilities to perform multi rigid body, flexible body, and mixed dynamic analyses of complex mechanisms. These capabilities were applied to accurately simulate: Inertial and mass properties of the device such as the vibration isolation system (VIS) effects and other ARED components, Non-linear joint friction effects, The gas law dynamics of the vacuum cylinders and VIS components using custom written differential state equations, The ARED flywheel dynamics, including torque limiting clutch. Design data from the JSC ARED Engineering team was utilized in developing the model. This included solid modeling geometry files, component/system specifications, engineering reports and available data sets. The Adams ARED module is importable into LifeMOD (Life Modeler, Inc., San Clemente, CA) for biomechanical analyses of different resistive exercises such as squat and dead-lift. Using motion capture data from ground test subjects, the ExPC developed biomechanical exercise models in LifeMOD. The Adams ARED device module was then integrated with the exercise subject model into one integrated dynamic model. This presentation will describe the development of the Adams ARED module including its capabilities, limitations, and assumptions. Preliminary results, validation activities, and a practical application of the module to inform the relative effect of the flywheels on exercise will be discussed.

Humphreys, B. T.↗

Ice sculpture in the Martian outflow channels

Viking Orbiter and terrestrial satellite images are examined at similar resolution to compare features of the Martian outflow channels with features produced by the movement of ice on earth, and many resemblances are found. These include the anastomoses, sinuosities, and U-shaped cross profiles of valleys; hanging valleys; linear scour marks on valley walls; grooves and ridges on valley floors; and the streamlining of bedrock highs. Attention is given to the question whether ice could have moved in the Martian environment. It is envisaged that springs or small catastrophic outbursts discharged fluids from structural outlets or chaotic terrains. These fluids built icings that may have grown into substantial masses and eventually flowed like glaciers down preexisting valleys. An alternative is that the fluids formed rivers or floods that in turn formed ice jams and consolidated into icy masses in places where obstacles blocked their flow.

Lucchitta, B. K.↗

The nakhlite meteorites: Augite-rich igneous rocks from Mars

The seven nakhlite meteorites are augite-rich igneous rocks that formed in flows or shallow intrusions of basaltic magma on Mars. They consist of euhedral to subhedral crystals of augite and olivine (to 1 cm long) in fine-grained mesostases. The augite crystals have homogeneous cores of Mg' = 63% and rims that are normally zoned to iron enrichment. The core-rim zoning is cut by iron-enriched zones along fractures and is replaced locally by ferroan low-Ca pyroxene. The core compositions of the olivines vary inversely with the steepness of their rim zoning - sharp rim zoning goes with the most magnesian cores (Mg' = 42%), homogeneous olivines are the most ferroan. The olivine and augite crystals contain multiphase inclusions representing trapped magma. Among the olivine and augite crystals is mesostasis, composed principally of plagioclase and/or glass, with euhedra of titanomagnetite and many minor minerals. Olivine and mesostasis glass are partially replaced by veinlets and patches of iddingsite, a mixture of smectite clays, iron oxy-hydroxides and carbonate minerals. In the mesostasis are rare patches of a salt alteration assemblage: halite, siderite, and anhydrite/ gypsum. The nakhlites are little shocked, but have been affected chemically and biologically by their residence on Earth. Differences among the chemical compositions of the nakhlites can be ascribed mostly to different proportions of augite, olivine, and mesostasis. Compared to common basalts, they are rich in Ca, strongly depleted in Al, and enriched in magmaphile (incompatible) elements, including the LREE. Nakhlites contain little pre-terrestrial organic matter. Oxygen isotope ratios are not terrestrial, and are different in anhydrous silicates and in iddingsite. The alteration assemblages all have heavy oxygen and heavy carbon, while D/H values are extreme and scattered. Igneous sulfur had a solar-system isotopic ratio, but in most minerals was altered to higher and lower values. High precision analyses show mass-independent fractionations of S isotopes. Nitrogen and noble gases are complex and represent three components: two mantle sources (Chas-E and Chas-S), and fractionated Martian atmosphere. The nakhlites are igneous cumulate rocks, formed from basaltic magma at approx.1.3 Ga, containing excess crystals over what would form from pure magma. After accumulation of their augite and olivine crystals, they were affected (to various degrees) by crystallization of the magma, element diffusion among minerals and magma, chemical reactions among minerals and magma, magma movement among the crystals, and post-igneous chemical equilibration. The extent of these modifications varies, from least to greatest, in the order: MIL03346, NWA817, Y000593, Nakhla = Governador Valadares, Lafayette, and NWA998. Chemical, isotopic, and chronologic data confirm that the nakhlites formed on Mars, most likely in thick lava flows or shallow intrusions. Their crystallization ages, referenced to crater count chronologies for Mars, suggest that the nakhlites formed on the large volcanic constructs of Tharsis, Elysium, or Syrtis Major. The nakhlites were suffused with liquid water, probably at approx.620 ma. This water dissolved olivine and mesostasis glass, and deposited iddingsite and salt minerals in their places. The nakhlites were ejected from Mars at approx.10.75Ma by an asteroid impact and fell to Earth within the last 10,000 years. Although the nakhlites are enriched in incompatible elements, their source mantle was strongly depleted. This depletion event was ancient, as the nakhlites source mantle was fractionated while short-lived radionuclides (e.g., t(sub 1/2 = 9 my) were still active. This differentiation event may have been core formation coupled with a magma ocean, as is inferred for the moon.

Treiman, Allan H.↗

ADEPT for Secondary Payloads

Deployable entry vehicles provide an enabling capability for large payloads at destinations across the solar system. The primary advantage of such systems derives from the fundamental limitation of available launch vehicle shroads preventing tried-and-true rigid aeroshell technology from being applied. However, little mission-pull exists for deployable entry vehicle technology for missions where the entry vehicle is the primary payload and can fit within available shrouds. The propensity toward applying rigid aeroshell technology is logical given that deployable concepts are higher risk and provide no marginal scientific benefit for missions where a rigid aeroshell is an option. A movement toward flying smaller spacecraft has emerged in recent years and is revealing novel applications for deployable entry vehicles as secondary payloads. Secondary payloads must minimize interference with the primary payload in order to ease accomodation. Advancements in small spacecraft technology have caught the attention of government entities who are now recognizing the high value proposition of small spacecraft for frequent, incremental technology development and science return rather than the traditional high cost and infrequent big-bang approaches. Worldwide, well over 200 small satellites (mass < 180 kg) have launched in recent years for such purposes as eduation, technology development, science, commerce, and defense. The Adaptable Deployable Entry and Placement Technology (ADEPT), a mechanically-deployable entry vehicle technology, has been under development at NASA since 2011. An Ames Center Innovation Fund (CIF) proposal was recently awarded to study ADEPT for EDL of small payloads. The unique capability of ADEPT for small science payloads comes from its ability to stow within a slender volume and deploy passively to achieve a mass-efficient drag surface with a high heat rate capability. The low ballistic coefficient results in entry heating and mechanical loads that can be met by a revolutionary three-dimensionally woven carbon fabric supported with rib structures. This carbon fabric has test-proven capability as both primary structure and payload thermal protection. This presentation will inform the EDL community of the capability of ADEPT for delivery of small secondary payloads as well as provide status of on-going technology development activities. Results of a mission applications study for secondary payloads to Mars and Venus will be presented. A primary goal of these mission design activities is to integrate high-value verification approaches wherever possible. For example, for some mission applications it is possible to test in NASA arc jet facilities at full-scale. This enables endto- end thermostructural requirement verification with a single test. Another important challenge that needs to be solved is the reliability of the decelerator to achieve the desired shape using simple passive mechanical actuators (such as springs) that do not require power from the primary payload for deployment. A configuration of ADEPT is being prototyped and used to evaluate the functionality and reliability of the deployment mechanism through bench-top testing. The prototype will then be tested in a low speed wind tunnel in late 2014 to evaluate aerodynamic load-carrying capability and deflected shape. Results of the deployment testing and status of wind tunnel test plans will be discussed.

Smith, B.↗

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell↗

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell↗

Skylab Experiment M516 - Crew Activities/Maintenance Study

Skylab required daily movement about the interior of a 340 cu m vehicle and the handling and transfer of numerous loose items. Planned and unplanned maintenance tasks were also included in the daily routine of activity. Experiment M516, Crew Activities/Maintenance Study, involved an investigation of crew activity during routine daily operations. The overall objective was to secure in-flight data relevant to the performance of tasks in the weightless environment. This paper will present an evaluation of man's ability to handle and transport items of various sizes and masses (logistics management) and to make equipment repairs (maintenance). Results and conclusions are based on subjective crew comments, motion-picture film, and television transmissions.

Bond, R. L.↗

Haughton-Mars Project Expedition 2005

The 2005 expedition to the Haughton-Mars Project (HMP) research station on Devon Island was part of a NASA-funded project on Space Logistics. A team of nine r&searchers from MIT went to the Canadian Arctic to participate in the annual I-IMP field campaign from July 8 to August 12, 2005. We investigated the applicability of the HMP research station as an analogue for planetary macro- and micro-logistics to the Moon and Mars, and began collecting data for modeling purposes. We also tested new technologies and procedures to enhance the ability of humans and robots to jointly explore remote environments. The expedition had four main objectives. We briefly summarize our key findings in each of these areas. 1. Classes of Supply: First, we wanted to understand what supply items existed at the HMP research station in support of planetary science and exploration research at and around the Haughton Crater. We also wanted to quantify the total amount of imported mass at HMP and compare this with predictions from existing parametric lunar base demand models. 2. Macro-Logistics Transportation Network: Our second objective was to understand the nodes, transportation routes, vehicles, capacities and crew and cargo mass flow rates required to support the HMP logistics network. 3. Agent and Asset Tracking: Since the current inventory management system on ISS relies heavily on barcodes and manual tracking, we wanted to test new automated technologies and procedures such as radio frequency identification RFID) to support exploration logistics. 4. Micro-Logistics (EVA): Finally, we wanted to understand the micro-logistical requirements of conducting both short (<1 day) and long traverses in the Mars-analog terrain on Devon Island. Micro-logistics involves the movement of surface vehicles, people and supplies from base to various exploration sites over short distances (<100 km).

deWeck, Olivier↗

Implicit Formulation of Muscle Dynamics in OpenSim

Astronauts lose bone and muscle mass during spaceflight. Exercise countermeasure is the primary method for counteracting bone and muscle mass loss in space. New spacecraft exercise device concepts are currently being developed for the NASAs new crew exploration vehicle. The NASA Digital Astronaut Project (DAP) uses computational modeling to help determine if the new exercise devices will be effective as countermeasures. The NASA Digital Astronaut Project is developing the ability to utilize predictive simulation to provide insight into the change in kinematics and kinetics with a change in device and gravitational environment (1-g versus 0-g). For example, in space exercise the subject's body weight is applied in addition to the loads prescribed for musculoskeletal maintenance. How and where these loads are applied obviously directly impacts bone and tissue loads. Additionally, due to space vehicle structural requirements, exercise devices are often placed on vibration isolation systems. This changes the apparent impedance or stiffness of the device as seen by the user. Data collection under these conditions is often impractical and limited. Predictive modeling provides a means to have a virtual subject to test hypotheses. Predictive simulation provides a virtual subject for which we are able to perform studies such as sensitivity to device loading and vibration isolation without the need for laboratory kinematic or kinetic test data.Direct Collocation optimization provides an efficient means to perform task based optimization and predictive modeling. It is relatively straight forward to structure a physical exercise task in a Direct Collocation mathematical formulation: perform a motion such that you start at an initial pose, achieve a given amount of deflection i.e a squat, return to the initial pose, and minimize muscle activation cost. Direct Collocation is advantageous in that it does not require numerical integration to evaluate the objective function. Instead, the system dynamics are transformed to discrete time and the optimizer is constrained such that the solution is not considered to be a valid unless the dynamic equations are satisfied at all time points. The simulation and optimization are effectively done simultaneously. Due to the implicit integration, time steps can be more coarse than in a differential equation solver. In a gait scenario this means that that the model constraints and cost function are evaluated at 100 nodes in the gait cycle versus 10,000 integration steps in a variable-step forward dynamic simulation. Furthermore, no time is wasted on accurate simulations of movements that are far from the optimum. Constrained optimization algorithms require a Jacobian matrix that contains the partial derivatives of each of the dynamic constraints with respect to of each of the state and control variables at all time points. This is a large but sparse matrix. An implicit dynamics formulation requires computation of the dynamic residuals f as a function of the states x and their derivatives, and controls u:f(x, dxdt, u) 0If the dynamics of musculoskeletal system are formulated implicitly, the Jacobian elements are often available analytically, eliminating the need for numerical differentiation; this is obviously computationally advantageous. Additionally, implicit formulation of musculoskeletal dynamics do not suffer from singularities from low mass bodies, zero muscle activation, or other stiff system or

physical exercise↗

Spatial and Temporal Deconfliction of Trajectories in the Presence of Uncertainties

Demonstration of conflict-free movement for multi-agent teams in challenging scenarios is crucial in developing trust and trustworthiness in an autonomous transport system. Tolerance verification queries are explored as a mechanism to enforce spatial and temporal deconfliction for a cooperating team of Unmanned Aerial Systems (UAS) with prescribed heterogeneous path-following performance. Obstacles in the environment are modelled as set of polyhedra, whereas each vehicle’s trajectory is represented as a sequence of polynomial curves with C2 continuity, expressed in a Bernstein basis. Each vehicle is modelled as a point mass and a safety distance, informed by the geometry of the UAS and the worst-case path-following error. This defines a tube around the trajectories where each UAS is most likely to fly through. In addition, obstacles in the environment have an associated safety buffer around them to account for the uncertainty in their location and geometric description. The tolerance verification queries explored in this paper combine the safety distance information from each UAS and environmental hazard to compute trajectories that are contained within the safe configuration space. Tolerance verification is also compared with other proximity queries to determine the suitability of each method along the different steps of the trajectory generation algorithm. This paper analyzes the fitness and performance of three proximity queries – collision, tolerance verification, and distance computations – between polyhedral and polynomial curves to ensure deconfliction between obstacles and vehicles, but also between polynomial curves to guarantee safe separation among cooperating UAS.

trajectory generation↗

Laboratory Evaluation to Increase Effectiveness of Field-Scale Soil Flushing in the Hanford 100 Areas

This laboratory study was initiated to develop an improved technical understanding of the key controlling geochemical and physical processes of mobilizing residual Cr(VI) in Hanford sediments to provide increased effectiveness in soil flushing activities planned for Hanford 100 Areas. This was accomplished by (1) quantifying Cr mass, release rate, and surface phase changes as Cr is leached from different Hanford sediments; (2) maximizing Cr leaching during soil flushing by evaluating different leach solutions and leach strategies; and (3) minimizing leaching of remaining residual Cr after soil flushing ends. To quantify geochemical controls on Cr leaching from sediments, sequential liquid extractions were used to identify aqueous, adsorbed, and solid Cr surface phases (precipitates or Cr incorporated into other phases) before and after water-saturated and unsaturated leach experiments with pH 8 artificial groundwater and with other amendment solutions. Changes in the Cr release rate from sediments were also correlated to changes in Cr surface phases. During unsaturated infiltration, water advection occurs primarily through larger pores, with less movement through smaller grain layers leading to a slower release of Cr trapped in smaller pores next to smaller grains. To quantify these physical controls on Cr leaching from sediments, 10 ft high 1-D infiltration experiments were conducted at differing leach solution application rates, and Cr leaching during application and subsequent residual water flow was quantified. Qualitative 2-D experiments were also conducted to evaluate surfactant addition to increase flow in low-permeability zones. Cr-contaminated Hanford sediments from the 100-H, 100-K, 100-D, and 200 East Areas exhibited a wide variety of leach behavior from rapid release of a small amount of Cr to fast (i.e., minutes) and slow (i.e., hours or more) release of high Cr. Sediments with low labile Cr (< 0.2 µg/g) exhibited fast Cr release but less overall release, and most (>95%) leached from the sediments within a few pore volumes in water-saturated columns. With nearly no sorption of chromate, aqueous and sorbed Cr (as chromate) were released quickly from sediment within the first few pore volumes, resulting in high leach concentrations, fast initial Cr release rates, and changes in pre- and post-leach extractions. In contrast, sediments with high labile Cr (0.2 to 20 µg/g) exhibited a combination of fast and slow Cr release due to multiple Cr surface phases contributing to Cr release from the sediment at different rates with greater overall release. This resulted in elevated Cr effluent concentrations even after dozens of pore volumes were leached. In addition, the Cr release rate decreased with increasing time during leaching. A decrease in labile Cr (aqueous Cr, adsorbed Cr, pH 5 acetate dissolved precipitates) in post-leach extractions compared to pre-leach extractions showed initial aqueous and adsorbed Cr release, followed by dissolution of high-solubility precipitates such as CaCrO 4 (if present), then slow dissolution of calcite that may contain some chromate and possibly BaCrO 4 . The labile Cr in all sediments correlated well with the Cr release rate (r 2 = 0.81). Labile Cr also correlated well with the leached mass in water-saturated columns (r 2 = 0.98), and therefore can be used for prediction of potential removal with flushing applications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geodetic and geophysical results from Lageos

Seven years of laser tracking of the Lageos spacecraft have been used to derive geodetic quantities describing the earth and its rotational motion. The dynamical motions of the solid-earth on its axis have been derived continuously since launch and changes in the length-of-day show very high correlation with variations in the atmospheric zonal winds between 1000 and 50 mbars. A significant improvement in the determination of the product of the earth's mass and the gravitational constant has been made. The high accuracy of the orbit determination of Lageos over the 7 years since launch has permitted the identification of a small deceleration in the nodal precession of the orbit. This deceleration is being caused by a small reduction in the flattening of the earth arising from the rebound of the earth after the last ice age. Measurements of the distances between the tracking stations over several years are showing changes consistent with tectonic plate motion and with general ideas of vertical movements.

Smith, D. E.↗

Isolation of Resistance-Bearing Microorganisms

To better exploit the principles of gas transport and mass transport during the processes of cell seeding of 3D scaffolds and in vitro culture of 3D tissue engineered constructs, the oscillatory cell culture bioreactor provides a flow of cell suspensions and culture media directly through a porous 3D scaffold (during cell seeding) and a 3D construct (during subsequent cultivation) within a highly gas-permeable closed-loop tube. This design is simple, modular, and flexible, and its component parts are easy to assemble and operate, and are inexpensive. Chamber volume can be very low, but can be easily scaled up. This innovation is well suited to work with different biological specimens, particularly with cells having high oxygen requirements and/or shear sensitivity, and different scaffold structures and dimensions. The closed-loop changer is highly gas permeable to allow efficient gas exchange during the cell seeding/culturing process. A porous scaffold, which may be seeded with cells, is fixed by means of a scaffold holder to the chamber wall with scaffold/construct orientation with respect to the chamber determined by the geometry of the scaffold holder. A fluid, with/without biological specimens, is added to the chamber such that all, or most, of the air is displaced (i.e., with or without an enclosed air bubble). Motion is applied to the chamber within a controlled environment (e.g., oscillatory motion within a humidified 37 C incubator). Movement of the chamber induces relative motion of the scaffold/construct with respect to the fluid. In case the fluid is a cell suspension, cells will come into contact with the scaffold and eventually adhere to it. Alternatively, cells can be seeded on scaffolds by gel entrapment prior to bioreactor cultivation. Subsequently, the oscillatory cell culture bioreactor will provide efficient gas exchange (i.e., of oxygen and carbon dioxide, as required for viability of metabolically active cells) and controlled levels of fluid dynamic shear (i.e., as required for viability of shear-sensitive cells) to the developing engineered tissue construct. This bioreactor was recently utilized to show independent and interactive effects of a growth factor (IGF-I) and slow bidirectional perfusion on the survival, differentiation, and contractile performance of 3D tissue engineering cardiac constructs. The main application of this system is within the tissue engineering industry. The ideal final application is within the automated mass production of tissue- engineered constructs. Target industries could be both life sciences companies as well as bioreactor device producing companies.

Venkateswaran, Kasthuri, J.↗

Oscillating Cell Culture Bioreactor

To better exploit the principles of gas transport and mass transport during the processes of cell seeding of 3D scaffolds and in vitro culture of 3D tissue engineered constructs, the oscillatory cell culture bioreactor provides a flow of cell suspensions and culture media directly through a porous 3D scaffold (during cell seeding) and a 3D construct (during subsequent cultivation) within a highly gas-permeable closed-loop tube. This design is simple, modular, and flexible, and its component parts are easy to assemble and operate, and are inexpensive. Chamber volume can be very low, but can be easily scaled up. This innovation is well suited to work with different biological specimens, particularly with cells having high oxygen requirements and/or shear sensitivity, and different scaffold structures and dimensions. The closed-loop changer is highly gas permeable to allow efficient gas exchange during the cell seeding/culturing process. A porous scaffold, which may be seeded with cells, is fixed by means of a scaffold holder to the chamber wall with scaffold/construct orientation with respect to the chamber determined by the geometry of the scaffold holder. A fluid, with/without biological specimens, is added to the chamber such that all, or most, of the air is displaced (i.e., with or without an enclosed air bubble). Motion is applied to the chamber within a controlled environment (e.g., oscillatory motion within a humidified 37 C incubator). Movement of the chamber induces relative motion of the scaffold/construct with respect to the fluid. In case the fluid is a cell suspension, cells will come into contact with the scaffold and eventually adhere to it. Alternatively, cells can be seeded on scaffolds by gel entrapment prior to bioreactor cultivation. Subsequently, the oscillatory cell culture bioreactor will provide efficient gas exchange (i.e., of oxygen and carbon dioxide, as required for viability of metabolically active cells) and controlled levels of fluid dynamic shear (i.e., as required for viability of shear-sensitive cells) to the developing engineered tissue construct. This bioreactor was recently utilized to show independent and interactive effects of a growth factor (IGF-I) and slow bidirectional perfusion on the survival, differentiation, and contractile performance of 3D tissue engineering cardiac constructs. The main application of this system is within the tissue engineering industry. The ideal final application is within the automated mass production of tissue- engineered constructs. Target industries could be both life sciences companies as well as bioreactor device producing companies.

Freed, Lisa E.↗

Topology of the germ plasm and development of primordial germ cells in inverted amphibian eggs

Inverted Xenopus eggs have reduced numbers of primordial germ cells (PGCs). The extent of the reduction varies from spawning to spawning. Histologic examination revealed that PGC counts were lowest in inverted eggs which displayed the greatest amount of shift in the vegetal mass of large yolk platelets, although the germ plasm itself always remained localized in the egg's original vegetal hemisphere. Even at blastulation the germ plasm continued to be localized in the egg's original vegetal hemisphere. In many cases, however, it was confined to the periphery of the embryo, which probably accounts for the reduced PGC number in some tadpoles. In other cases it may have been dispersed and therefore not detectable in histologic analyses. Although the altered site of involution in inverted embryos did not influence PGC development, subsequent cell movement patterns apparently did. Those embryos which displayed the largest degree of pattern reversal at the tail-bud stage also exhibited the most extreme reduction in PGC numbers. A brief cold shock (4 degrees C, 10 min) prior to first cleavage leads to a further reduction in PGC numbers in inverted embryos, probably as a result of the displacement of the germ plasm away from its original vegetal pole location.

Cell Polarity/physiology↗

Radionuclide surrogate aerosolization, resuspension and suppression in hazardous situations

Radioactive fire following nuclear accidents causes resuspension of radioactive contamination that can spread over large areas. Although many papers focus on particle deposition and resuspension, a limited number of studies model its suppression. Even less data is available for the comparison of emissions across particle size, surface, and mode of resuspension. In this study, cerium dioxide surrogate for internal hazards such as radionuclide particle matter was aerosolized into a large chamber and subsequently resuspended after sedimentation. Resuspension was induced by common modes of human movement including walking, wind, and driving on common surfaces including polyvinyl chloride (PVC), artificial grass (turf), and concrete in a 5.8 m long, 3.7 m wide and 3 m high tent. The resuspension was experimentally measured for two particle sizes (1 and 10 μm) at three different heights (0.3 m, 1.2 m, and 2.4 m) and compared across size, surface, and mode of resuspension. Particle size distribution was measured using an aerodynamic particle sizer and the resuspended particles were collected with the wetted wall cyclone aerosol collector and quantitated using inductively coupled plasma mass spectrometry. The testing was repeated with the F-500 fire retardant application to study its effect on resuspension. In this study, artificial grass flooring was found to generate the most resuspension, with walking on turf for the 1 μm particle testing yielding the highest factor overall. Concrete had the lowest resuspension, showing variations in the size distribution of aerosol as a function of height from the source resuspension factors. The application of fire retardant was found to significantly reduce surrogate resuspension, regardless of resuspension method or testing surface. Here, the results provide impactful information regarding the different modes of resuspension including human transport (walking and driving) and wind for the resuspension of radionuclide surrogate particles deposited onto common surfaces and the effect of fire retardant application on their resuspension, leading to higher levels of safety for nuclear energy plants and facilities.

42 ENGINEERING↗

Comparison of sleep parameters from wrist-worn ActiGraph and Actiwatch devices

Abstract Sleep and physical activity, two important health behaviors, are often studied independently using different accelerometer types and body locations. Understanding whether accelerometers designed for monitoring each behavior can provide similar sleep parameter estimates may help determine whether one device can be used to measure both behaviors. Three hundred and thirty one adults (70.7 ± 13.7 years) from the Baltimore Longitudinal Study of Aging wore the ActiGraph GT9X Link and the Actiwatch 2 simultaneously on the non-dominant wrist for 7.0 ± 1.6 nights. Total sleep time (TST), wake after sleep onset (WASO), sleep efficiency, number of wake bouts, mean wake bout length, and sleep fragmentation index (SFI) were extracted from ActiGraph using the Cole–Kripke algorithm and from Actiwatch using the software default algorithm. These parameters were compared using paired t-tests, Bland–Altman plots, and Deming regression models. Stratified analyses were performed by age, sex, and body mass index (BMI). Compared to the Actiwatch, the ActiGraph estimated comparable TST and sleep efficiency, but fewer wake bouts, longer WASO, longer wake bout length, and higher SFI (all p < .001). Both devices estimated similar 1-min and 1% differences between participants for TST and SFI (β = 0.99, 95% CI: 0.95, 1.03, and 0.91, 1.13, respectively), but not for other parameters. These differences varied by age, sex, and/or BMI. The ActiGraph and the Actiwatch provide comparable absolute and relative estimates of TST, but not other parameters. The discrepancies could result from device differences in movement collection and/or sleep scoring algorithms. Further comparison and calibration is required before these devices can be used interchangeably.

Liu, Fangyu (ORCID:0000000315541478)↗