Extended tables of stiffness and carry-over factor for structural members under axial load
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Big data generated by large-scale scientific and industrial applications need to be transferred between different geographical locations for remote storage, processing, and analysis. High-speed dedicated connections provisioned in High-performance Networks (HPNs) are increasingly utilized to carry out such big data transfer. HPN management highly relies on an important capability of performance (mainly throughput) prediction to reserve sufficient bandwidth and meanwhile avoid over-provisioning that may result in unnecessary resource waste. This capability is critical to improving the resource (mainly bandwidth) utilization of dedicated connections and meeting various user requests for data transfer. Conventional methods conduct performance prediction by fitting prior observed transfer history with predefined loss functions, without considering unobservable latent factors such as competing loads on end hosts. Such latent factors also have a significant impact on the application-level data transfer performance, which may result in an inaccurate prediction model. In this paper, we first investigate the impact of latent factors and propose a clustering-based method to eliminate their negative impact on performance prediction. We then develop a robust machine learning-based performance predictor by: i) incorporating the proposed latent factor elimination method into data preprocessing, and ii) adopting a customized domain guided loss function. Extensive experimental results show that our predictor achieves significantly higher prediction accuracy than several other state-of-the-art methods.
Stress-intensity factors calculated with a three-dimensional, finite-element analysis for shallow and deep semielliptical surface cracks in finite elastic isotropic plates subjected to tension or bending loads are presented. A wide range of configuration parameters was investigated. The ratio of crack depth to plate thickness ranged from 0.2 to 0.8 and the ratio of crack depth to crack length ranged from 0.2 to 2.0. The effects of plate width on stress-intensity variations along the crack front was also investigated. A wide-range equation for stress-intensity factors along the crack front as a function of crack depth, crack length, plate thickness, and plate width was developed for tension and bending loads. The equation was used to predict patterns of surface-crack growth under tension or bending fatigue loads. A modified form of the equation was also used to correlate surface-crack fracture data for a brittle epoxy material within + or - 10 percent for a wide range of crack shapes and crack sizes.
The benefits of nuclear thermal propulsion are numerous and relevant to the current NASA mission goals involving but not limited to the crewed missions to mars and the moon. They do however also present new and unique challenges to the design and logistics of launching/operating spacecraft. One of these challenges, relevant to this discussion, is the significant mass of the shielding which is required to ensure an acceptable radiation environment for the spacecraft and crew. Efforts to reduce shielding mass are difficult to accomplish from material and geometric design points of the shield itself, however by increasing the distance between the nuclear engines and the main body of the spacecraft the required mass of the shielding is lessened considerably. The mass can be reduced significantly per unit length, though any additional mass added by the structure to create this distance serves to offset those savings, thus the design of a lightweight structure is ideal. The challenges of designing the truss are bounded by several limiting factors including; the loading conditions, the capabilities of the launch vehicle, and achieving the ideal truss length when factoring for the overall mass reduced. Determining the overall set of mass values for a truss of varying length is difficult since to maintain an optimally designed truss the geometry of the truss or its members must change. Thus the relation between truss mass and length for these loading scenarios is not linear, and instead has relation determined by the truss design. In order to establish a mass versus length trend for various truss designs to compare with the mass saved from the shield versus length, optimization software was used to find optimal geometric properties that still met the design requirements at established lengths. By solving for optimal designs at various lengths, mass trends could be determined. The initial design findings show a clear benefit to extending the engines as far from the main structure of the spacecraft as the launch vehicle's payload volume would allow when comparing mass savings verse the additional structure.
A Deeply Embedded Ring Anchor (DERA) system has been developed as a cost-effective solution for mooring arrays of floating offshore wind turbines (FOWTs) to the seabed. The DERA boasts several key features, including its versatility in various soil types, compact size, compatibility with diverse mooring systems, multi-line potential, and robust performance even under unintentional loading conditions. While prior preliminary studies have provided valuable insights into how the DERA can enhance cost-effectiveness by offering a high load capacity, these studies have predominantly focused on optimizing anchor performance under translational horizontal and vertical loading. However, to design the DERA optimally, we must also consider its ability to handle inclined loading conditions in addition to lateral and axial loadings. Due to its shorter length compared to a conventional caisson, the DERA has less resistance to moments, making it more sensitive to horizontal load capacity and the optimal load attachment depth concerning load angle. For this reason, our study introduces an analytical approach to evaluate the effects of inclined loading on anchor performance, utilizing the previously validated upper bound plastic limit analysis (PLA) method. In investigating the optimal load attachment of the DERA, this paper conducts a parametric study to analyze how factors such as load attachment depth, anchor aspect ratio, and load inclination affect the DERA’s load capacity. Our findings indicate that PLA can serve as a valuable analytical tool for assessing the ultimate load capacity of the DERA, particularly under inclined loading conditions.
Techniques to predict the dynamic response and the structural dynamic loads of flat plate photovoltaic arrays due to wind turbulence were analyzed. Guidelines for use in predicting the turbulent portion of the wind loading on future similar arrays are presented. The dynamic response and the loads dynamic magnification factor of the two array configurations are similar. The magnification factors at a mid chord and outer chord location on the array illustrated and at four points on the chord are shown. The wind tunnel test experimental rms pressure coefficient on which magnification factors are based is shown. It is found that the largest response and dynamic magnification factor occur at a mid chord location on an array and near the trailing edge. A technique employing these magnification factors and the wind tunnel test rms fluctuating pressure coefficients to calculate design pressure loads due to wind turbulence is presented.
A revised gust-load formula with a new gust factor is derived to replace the gust-load formula and alleviation factor widely used in gust studies. The revised formula utilizes the same principles and retains the same simple form of the original formula but provides a more appropriate and acceptable basis for gust-load calculations. The gust factor is calculated on the basis of a one-minus-cosine gust shape and is presented as a function of a mass-ratio parameter in contrast to the ramp gust shape and wing loading, respectively, used for the alleviation factor. A summary of gust-velocity data from v-g records taken on civil transport airplanes from 1933 to 1950, reevaluated by the revised formula, is also presented.
11 tests were selected from two microcomputer-based performance test batteries because previously these tests exhibited rapid stability (less than 10 min, of practice) and high retest reliability efficiencies (r greater than 0.707 for each 3 min. of testing). The battery was administered three times to each of 108 college students (48 men and 60 women) and a factor analysis was performed. Two of the three identified factors appear to be related to information processing ("encoding" and "throughput/decoding"), and the third named an "output/speed" factor. The spatial, memory, and verbal tests loaded on the "encoding" factor and included Grammatical Reasoning, Pattern Comparison, Continuous Recall, and Matrix Rotation. The "throughput/decoding" tests included perceptual/numerical tests like Math Processing, Code Substitution, and Pattern Comparison. The output speed factor was identified by Tapping and Reaction Time tests. The Wonderlic Personnel Test was group administered before the first and after the last administration of the performance tests. The multiple Rs in the total sample between combined Wonderlic as a criterion and less than 5 min. of microcomputer testing on Grammatical Reasoning and Math Processing as predictors ranged between 0.41 and 0.52 on the three test administrations. Based on these results, the authors recommend a core battery which, if time permits, would consist of two tests from each factor. Such a battery is now known to permit stable, reliable, and efficient assessment.
The purpose of this study was to anchor thermal and fluid system models to data acquired from a ground test article (GTA) for the CRYogenic Orbital TEstbed - CRYOTE. To accomplish this analysis, it was broken into four primary tasks. These included model development, pre-test predictions, testing support at Marshall Space Flight Center (MSFC} and post-test correlations. Information from MSFC facilitated the task of refining and correlating the initial models. The primary goal of the modeling/testing/correlating efforts was to characterize heat loads throughout the ground test article. Significant factors impacting the heat loads included radiative environments, multi-layer insulation (MLI) performance, tank fill levels, tank pressures, and even contact conductance coefficients. This paper demonstrates how analytical thermal/fluid networks were established, and it includes supporting rationale for specific thermal responses seen during testing.
The antiplane shear problem for two bonded dissimilar half planes containing a semi-infinite crack or two arbitrarily located collinear cracks was considered. For the semi-infinite crack the problem was solved for a concentrated wedge load and the stress intensity factor and the angular distribution of stresses were calculated. For finite cracks the problem was reduced to a pair of integral equations. Numerical results were obtained for cracks fully imbedded in a homogeneous medium, one crack tip touching the interface, and a crack crossing the interface for various crack angles.
The antiplane shear problem for two bonded dissimilar half planes containing a semi-infinite crack or two arbitrarily located collinear cracks is considered. For the semi-infinite crack the problem is solved for a concentrated wedge load and the stress intensity factor and the angular distribution of stresses are calculated. For finite cracks the problem is reduced to a pair of integral equations. Numerical results are obtained for cracks fully imbedded in a homogeneous medium, one crack tip touching the interface, and a crack crossing the interface for various crack angles.
To assist analysis of riveted lap joints, stress intensity factors are determined for surface and corner cracks emanating from a wedge-loaded hole by using a 3-D weight function method in conjunction with a 3-D finite element method. A stress intensity factor equation for surface cracks is also developed to provide a closed-form solution. The equation covers commonly-encountered geometrical ranges and retains high accuracy over the entire range.
This paper evaluates the ruggedness testing of the newly released ASTM International E3097 Standard Test Method for Mechanical Uniaxial Constant Force Thermal Cycling of Shape Memory Alloys. The ruggedness experiment was designed with eight runs in two replicates, consisting of seven factors of strain rate (ė), heating and cooling rates (Ṫ(heat) and Ṫ(cool), respectively), upper and lower cycle temperatures (UCT and LCT, respectively), hold time (thold), and minimum load (Fmin) imparted on the samples. The results indicate that the hold time factor had no effect on any result variable. The minimum load factor, alternatively, had the greatest effect on several result variables, with the greatest influence on the strains at martensite start and finish (strain variation ~0.1 percent), and the strains at the upper and lower cycle temperatures (strain variation of 0.14 percent). The UCT was found to have a large effect on the austenite and martensite finish tangent line and data intersect, denoted by Af* and Mf*, by ~17 and 4 °C, respectively. The testing methodology, analysis techniques, and resulting conclusions on the ruggedness of the test methods are presented.
Load distribution schemes for minimizing the communication requirements of the Cholesky factorization of dense and sparse, symmetric, positive definite matrices on multiprocessor systems are presented. The total data traffic in factoring an n x n sparse symmetric positive definite matrix representing an n-vertex regular two-dimensional grid graph using n exp alpha, alpha not greater than 1, processors are shown to be O(n exp 1 + alpha/2). It is O(n), when n exp alpha, alpha not smaller than 1, processors are used. Under the conditions of uniform load distribution, these results are shown to be asymptotically optimal.
A broad parametric study which examines several critical aspects of low-heat-rate entry trajectories is performed. Low planform loadings associated with future winged earth-entry vehicles coupled with the potential application of metallic thermal protection systems (TPS) suggest that such trajectories are of particular interest. Studied are three heating conditions - reference, stagnation, and windward centerline, for both laminar and turbulent flow; configuration-related factors including planform loading and hypersonic angle of attack; and mission-related factors such as cross-range and orbit inclination. Results indicate benefits in the design of TPS to be gained by utilizing moderate angles of attack as opposed to high-lift coefficient, high angles of attack, during entry. An assessment of design and technology implications is made.
This paper evaluates the ruggedness testing of the recently released ASTM International E3098 Standard Test Method for Mechanical Uniaxial Pre-strain and Thermal Free Recovery of Shape Memory Alloys. The ruggedness experiment was designed with eight runs in two replicates, consisting of seven factors: strain rate (ė), heating and cooling rates (Ṫ heat and Ṫ cool , respectively), upper and lower cycle temperatures (UCT and LCT, respectively), hold time (t hold ), and minimum load (F min ) imparted on the samples. The results indicate that the strain rate factor had no effect on any result variable, whereas the minimum load factor had a large effect on several result variables including the austenite start and martensite finish temperatures as well as most of the strain measurements from the thermal cycle. The lower cycle temperature factor had a large effect on the stress at maximum strain during pre-straining (e i ), denoted by S i , at ~7.2 MPa, as well as the A f , at 5.47 °C. Closely following the LCT effect, Ṫ heat was found to have a large effect on the austenite start temperature (A s ), at a value of ~2.72 °C. The testing methodology, analysis techniques, and resulting conclusions on the ruggedness of the test method are presented.
This work examined the impact of large loads on utility distribution system models using the Sandia-developed open-source software DREAMS. It was shown that hosting capacity varies with location and changes after any asset is added to, or removed from, a system. Despite the tested models having similar rated voltages and other characteristics, their thermal and voltage constrained hosting capacity varied over 2 MW. The addition of a 3-phase balanced constant power large load with power factor of 1.0 exhibited non-linear reductions to all voltage constrained hosting capacities. The reductions to thermal constrained hosting capacity from a load with similar characteristics was more linear, related to the size of the added load, and did not impact all model buses. Co-located capacitors were shown to accommodate demand that was beyond the baseline voltage constrained hosting capacity limits, however, the costs and benefits from this approach were found to not be 1:1 and required additional available thermal capacity.
A plane elastic wedge-shaped solid was split through the application of a rigid punch. It was assumed that the coefficient of friction on the the contact area was constant, and the problem had a plane of symmetry with respect to loading and geometry, with the crack in the plane of symmetry. The problem was formulated in terms of a system of integral equations with the contact stress and the derivative of the crack surface displacement as the unknown functions. The solution was obtained for an internal crack and for an edge crack. The results include primarily the stress intensity factors at the crack tips, and the measure of the stress singularity at the wedge apex, and at the end points of the contact area.