Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Play Fairway Analysis: Structurally Controlled Geothermal Systems in the Eastern Great Basin Extensional Regime, Utah

A research team with membership from the University of Utah/Energy & Geoscience Institute, the University of Utah/Dept. of Geology & Geophysics, and the Utah Geological Survey, undertook a play fairway analysis (PFA) for geothermal resources in the Eastern Great Basin (EGB) extensional tectonic regime of western Utah. This is a high-priority region for geothermal exploration because active Basin and Range (B&R) extension with volcanism having a N-S strike is superimposed upon pre-existing E-W belts of plutonic rocks and large-scale structural lineaments. Cumulative heat flow along the N-S strike of the state totals approximately 5 GWt above background stable interior. Three electricity producing power plants currently exist with substantial potential for increase. Succinctly, our PFA approach aims to resolve potential sources of heat and permeability in the region, which are the two principal criteria for establishing a geothermal resource. An initial Phase 1 was carried out using only existing geoscientific data in the area. Criteria selected for focusing heat potential include direct heat flow measurements in boreholes, magnetotelluric (MT) low resistivity anomalies, fluid/gas geochemistry, and proximity to recent volcanic eruptions. Permeability is established through geological structures (fault density, critically stressed areas, seismicity, gravity), and MT low resistivity anomalies. In Phase II of this PFA project, additional geological, geophysical and geochemical data were acquired and analysis carried out primarily over promising composite common risk (CCR) areas initially identified in Phase I in order to focus prospectivity and prepare for drilling recommendations. These prospects are near the Twin Peaks rhyolite field, high heat flow areas north of the producing Cove Fort system, and geophysical structure beneath the Crater Knoll area off the northeast flank of the Mineral Mountains. Additional data included MT site fill-in, structural mapping and analysis using high-resolution imagery, gravity and on-ground mapping, Nodal 3C passive seismic collection, and passive 3He surveying. Heat source and permeability potential are again expressed in terms of their individual common risk segment (CRS) maps, with a color scheme using green for most favorable (low risk) and red for least favorable (high risk). Diverse data types are united through the technique of probability kriging, which establishes prospectivity thresholds for each data type and then computes probability of exceeding that threshold over the PFA area. Modified CRS and CCRS maps are compared to those of Phase I to highlight tighter prospectivity focus. In doing so, the prospectivity threshold for heat was increased significantly to narrow the targeting. In the final Phase III of this project where a recommended deep thermal gradient hole was sited, additional geophysical, geochemical and geological field collection and analysis was carried out to refine drill hole targeting. This includes prospect-scale MT, gravity, structure, passive seismic deployment (Cove Fort area), and detailed 3He isotope profiling. It was the recommendation of the DOE Technical Monitoring Team (TMT) that one or more holes be sited in the north-ern Cove Fort area where legacy TG gradient holes showed high cumulative heat flow. These were to be of moderate depth, 2000-3000 feet, to reach the geothermal fluid table expected to start in excess of 1000 feet depth. The drilling organization stipulated by the DOE/GTO was that of the USGS Research Drilling Program (RDP) centered in Las Vegas, NV. A detailed well plan, appended to this report, was developed principally by Dr. Ben Barker consulting to University of Utah, Dr. Steve Pye on the DOE TMT, Mr. Steven Crawford of the USGS-RDP, and the project PI Phil Wannamaker. However, temperature and possible H 2 S at the systems lead to cancellation of the drilling last-minute as this appeared outside the experience base of the USGS-RDP. We hope to have the opportunity to revisit the test drilling and expand the Play Fairway Analysis of this region at some point in the future.

15 GEOTHERMAL ENERGY↗

An Io thermal model with intermittent volcanism

Observations have indicated that heat flow out of Io at present may be several times greater than the heat input from enhanced tidal heating; this may indicate that the observed heat flow is intermittent, rather than continuous. A two-dimensional time-dependent thermal model of Io was constructed to examine the relationship between enhanced tidal heating, heat flow within the body, and surface volcanism. From the models one can conclude that (1) a simple homogeneous body cannot maintain enhanced tidal heating in a thin crust, but such heating is possible if the crust contains an insulating layer, as of sulfur; (2) this sulfur layer will be subject to melting by heat from the interior, resulting in hotspots which can expel heat much more rapidly than tidal heating inputs it; and (3) the location of these hotspots will vary in time and space; they can appear anywhere on the surface, even if tidal heating is concentrated at the poles, and they seem to occur roughly 10% of the time.

Consolmagno, G. J.↗

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE↗

The Lunar Geophysical Network Mission

Overarching Principles: Must be better than Apollo (coverage, duration, instrument performance); Learn from the Apollo experience. Lunar Geophysical Network (LGN) New Frontiers (NF)-class mission, as part of the NF-5 call. “This mission consists of several identical landers distributed across the lunar surface, each carrying geophysical instrumentation. The primary science objectives are to characterize the Moon’s internal structure, seismic activity, global heat flow budget, bulk composition, & magnetic field.” Global distribution of multiple stations. Each station should contain a seismometer, heat flow probe, electromagnetic sounder, laser retroreflector (lunar nearside). Each station must be long-lived (e.g., approximately10 years)to allow other stations (from other countries?) to be integrated with the anchor nodes to form the International Lunar Network. Why LGN? Planetary Science: Moon represents an end-member in planetary evolution (large small body, small rocky planet); Primary planetary differentiation preserved; Key to understanding terrestrial planet initial differentiation. Lunar Science: Heat flow probes yield crustal heat budget estimates; Combined with EMS (ElectroMagnetic Sounding), the temperature profile of the deep interior can be modeled along with mineralogy; Seismic and LLR (Lunar Laser Ranging) data also yield structure and compositional information of the lunar interior; High fidelity data from LGN would enhance the usefulness of the GRAIL (Gravity Recovery and Interior Laboratory) and SELENE (Selenological and Engineering Explorer) gravity data. Human Exploration: LGN must be established prior to renewed human lunar activity - we do not know the exact locations or causes of the shallow moonquakes (SMQs) - the largest magnitude seismic events recorded by Apollo (1 event per year of magnitude greater than or equal to 5); Establishing surface infrastructure near SMQ epicenters must be avoided.

Neal, C. R.↗

Effect of diffusion-thermal processes on the high-latitude topside ionosphere

The extent to which diffusion-thermal heat flow affects H(+) temperatures in the high-latitude topside ionosphere is studied. Such a heat flow occurs whenever there are H(+)-O(+) relative drifts. From our study we have found that at high-latitudes, where H(+) flows up and out of the topside ionosphere, diffusion-thermal heat flow acts to reduce H(+) temperatures by 500-600 K at altitudes above about 900 km.

Schunk, R. W.↗

Heat Analysis Manager (HAM), a Thermal Desktop API Based Heat Map Generation Software

Thermal engineers often create custom heat maps to analyze their thermal model. However, generating a heat map is difficult because thermal simulation only readily provide attributes of simulated nodes such as temperature, capacitance, heat generation, and a network of conductances. Heat flow values are a derived quantity from the nodal attributes, and the data processing and management of heat flow between nodes quickly become difficult for large models. Deriving a network of heat flow values requires vast amount of calculations and data handling, heat map generation process generally suffers from processing speed, loss of accuracy, and/or presentation of data in a useful format. Heat Analysis Manager (HAM) is a Thermal Desktop (TD) based free multi-purpose tool developed to aid thermal engineers in analyzing their thermal model, including a heat map generation functionality. HAM’s heat map generator retains accuracy and fast processing speed by utilizing TD’s application programming interface (API) and built-in TD’s “Qflow from Results.” Furthermore, HAM’s heat map output is presented in an easily customizable format in Excel, allowing users to create various custom visual heat maps. A full description of how HAM utilizes TD’s API to create a customizable heat map is provided. A simple model demonstration is included along with step-by-step procedures on creating custom heat maps. HAM’s heat map result has been verified against TD’s and other heat map generation software, and verification methods are also included.

Thermal desktop↗

Thermal coupling apparatus for electroexplosive devices

This paper describes the equipment for nondestructive testing of electroexplosive devices using a thermal coupling technique. The technique utilizes a self-balancing bridge to apply a nominal amount of power to the bridge wire of the device. The bridge wire behaving as a thermal sensor detects heat flow into the device when heat is preferentially directed down the center of the explosive column toward the bridge wire. Thermal equilibrium is upset and the change in power from the self-balancing bridge is measured directly in watts. Faults such as omissions, incorrect materials, contamination, and so on, can be detected by observing the rate of heat flow to the bridge wire. The response is indicative of the thermal resistance and diffusivity of the system. The paper also presents data on electroexplosive devices loaded with inert and explosive materials.

Menichelli, V. J.↗

Effect of a liquid-type temperature rise inhibitor on cement hydration

A liquid-type temperature rise inhibitor (L-TRI) based on modified sorbitol was developed to solve the thermal cracking issue by modulating the heat release from cement hydration during the early age. Both the exothermic process and phase evolution of cement pastes blended with/without L-TRI were investigated by the combination of isothermal calorimetry, in-situ XRD, ICP-OES and SEM. Also, the adsorption of the L-TRI in the cement paste was identified by total organic carbon analysis. The testing results suggested that the L-TRI affected the heat flow curve in two ways. It prolonged the induction period as a retarding effect. It also reduced the heat flow during the acceleration period and decreased the maximum heat flow as a depressing effect. The retarding effect was mainly caused by the complexation of unabsorbed molecules in the pore solution, and the depressing effect was caused by inhibiting the growth of C-S-H.

36 MATERIALS SCIENCE↗

Analysis of the effect of heated jet flow on the far field radiation from a noise source

The influence on jet noise radiation of the interaction with the heated moving flow of a parallel twin jet is investigated. An analytical model of jet shielding is developed which consists of the sound field emitted from a stationary, discrete frequency point source impinging on a cylinder of locally parallel flow. The zones in which the various shielding mechanisms dominate are analyzed using the model. The effects of parameters such as jet temperature and flow speed are examined. It is found that the results obtained using the model are comparable to the experimental results for a point noise source impinging on a subsonic isothermal air jet.

Gerhold, C.↗

Magnetic Heat Pump Containing Flow Diverters

Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

Howard, Frank S.↗

A study of leeside flow field heat transfer on Shuttle Orbiter configuration

A coupled inviscid and viscous theoretical solution of the flow about the entire configuration is the desirable and comprehensive approach to defining thermal environments about the space shuttle orbiter. Simplified methods for predicting entry heating on leeside surfaces of the orbiter are considered. Wind tunnel heat transfer and oil flow data at Mach 6 and 10 and Reynolds numbers ranging from 500,000 to 73 million were used to develop correlations for the wing upper surface and the top surface of the fuselage. These correlations were extrapolated to flight Reynolds number and compared with heating data obtained during the shuttle STS-2 reentry. Efforts directed toward the wing leeside surface resulted in an approach which generally agreed with the flight data. Heating predictions for the upper fuselage were less successful due to the extreme complexity of local flow interactions and the associated heating environment.

Baranowski, L. C.↗

Flow Boiling Heat Transfer Characteristics of Water for Metal-foam-filled Horizontal Tubes

The goal of this paper is to enhance the in-tube flow boiling heat transfer of water while accounting for potential increase in pressure drop. Metal foams are a class of cellular structure with large surface-area-to-volume ratio and tortuous structure which has shown promising results for various energy conversion and storage applications. The higher heat transfer area and higher nucleation sites density due to the porous media can effectively enhance the heat transfer of water in both single-phase and two-phase operations. This paper presents the local heat transfer and pressure drop measurements of water in a partially metal-foam-filled horizontal copper tube. The ranges of parameters in the experiments are: mass flux from 80 to 200 kg/s-m2, heat flux from 3.5 to 105 kW/m2, and vapor quality from subcooled to 0.3. The results in the metal-foam-filled tube are compared with that of the bare copper tube. The effect of metal foam on the thermal hydraulic characteristics is discussed and analyzed. In addition, the two-phase flow behavior in a transparent tube filled with the same metal foam was visualized and investigated by high-speed imaging system. The experiments were also conducted in the tube without the metal foam for comparison.

Nawaz, Kashif↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical solution of fluid flow and heat tranfer problems with surface radiation

This paper presents a numerical scheme, based on the finite element method, to solve strongly coupled fluid flow and heat transfer problems. The surface radiation effect for gray, diffuse and isothermal surfaces is considered. A procedure for obtaining the view factors between the radiating surfaces is discussed. The overall solution strategy is verified by comparing the available results with those obtained using this approach. An analysis of a thermosyphon is undertaken and the effect of considering the surface radiation is clearly explained.

Ahuja, S.↗

Boundary-layer computational model for predicting the flow and heat transfer in sudden expansions

Fully developed turbulent and laminar flows through symmetric planar and axisymmetric expansions with heat transfer were modeled using a finite-difference discretization of the boundary-layer equations. By using the boundary-layer equations to model separated flow in place of the Navier-Stokes equations, computational effort was reduced permitting turbulence modelling studies to be economically carried out. For laminar flow, the reattachment length was well predicted for Reynolds numbers as low as 20 and the details of the trapped eddy were well predicted for Reynolds numbers above 200. For turbulent flows, the Boussinesq assumption was used to express the Reynolds stresses in terms of a turbulent viscosity. Near-wall algebraic turbulence models based on Prandtl's-mixing-length model and the maximum Reynolds shear stress were compared.

Lewis, J. P.↗

Heat exchanger with oscillating flow

Various heat exchange apparatuses are described in which an oscillating flow of primary coolant is used to dissipate an incident heat flux. The oscillating flow may be imparted by a reciprocating piston, a double action twin reciprocating piston, fluidic oscillators, or electromagnetic pumps. The oscillating fluid flows through at least one conduit in either an open loop or a closed loop. A secondary flow of coolant may be used to flow over the outer walls of at least one conduit to remove heat transferred from the primary coolant to the walls of the conduit.

Scotti, Stephen J.↗