Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rocket observations of electron density in the nighttime E region using Faraday rotation

A rocket radio propagation experiment is described in which the electron density profile of the nighttime E region is obtained with an accuracy of 100 per cu cm. The factors limiting the accuracy of the experiment are found to be related to atmospheric and receiver noise and to the use of a magnetometer to determine the spin rate of the rocket. The Fourier analysis used for the frequency measurement may also contribute error under conditions of steep electron density gradients. The accuracy being achieved appears to be adequate for present applications of the experiment.

Smith, L. G.↗

Experimental and experimental-theoretical topological characteristics of the electron density distribution in the crystal of N{sup CN}-(2-pyridinecarbonitrile)-(3,6-di-tert-butylcatecholato)triphenylantimony(v)

Experimental and experimental-theoretical studies (the invariom approach, whole-molecule aspherical scattering factors) of the electron density distribution were carried out to compare its topological characteristics at the critical points (3, −1) of the N{sup CN}-(2-pyridinecarbonitrile)-(3,6-di-tert-butylcatecholato)triphenylantimony(v) complex. The topological characteristics of the electron density distribution at the critical points (3, −1) and the atomic volumes determined in experimental studies are almost in quantitative agreement with the results of experimental-theoretical investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global GNSS-RO Electron Density in the Lower Ionosphere

Lack of instrument sensitivity to low electron density (Ne) concentration makes it difficult to measure sharp Ne vertical gradients (four orders of magnitude over 30 km) in the D/E-region. A robust algorithm is developed to retrieve global D/E-region Ne from the high-rate GNSS radio occultation (RO) data, to improve spatio-temporal coverage using recent SmallSat/CubeSat constellations.The new algorithm removes F-region contributions in the RO excess phase profile by fitting a linear function to the data below the D-region.The new GNSS-RO observations reveal many interesting features in the diurnal, seasonal, solar-cycle, and magnetic-field-dependent variations in the Ne morphology. While the D/E-region Ne is a function of solar zenith angle (c), it exhibits strong latitudinal variations for the same c with a distribution asymmetric about noon. In addition, large longitudinal variations are observed along the same magnetic field pitch angle. The summer-midlatitude Ne and sporadic-E(Es) show a distribution similar to each other. The distribution of auroral electron precipitation correlates better with the pitch angle from the magnetosphere than from one at100 km. Finally, anew TEC retrieval technique is developed for the high-rate RO data with a top reaching at least 120 km. For better characterization of the E-to-F transition in Ne and more accurate TEC retrievals, it is recommended to have all GNSS-RO acquisition routinely up to 220 km.

GNSS radio occultation↗

Technical Note: Exploring the limit for the conversion of energy-subtracted CT number to electron density for high-atomic-number materials

Purpose: For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the authors had previously proposed a novel conversion of the energy-subtracted CT number to an electron density (ΔHU–ρ{sub e} conversion), which provides a single linear relationship between ΔHU and ρ{sub e} over a wide ρ{sub e} range. The purpose of this study is to address the limitations of the conversion method with respect to atomic number (Z) by elucidating the role of partial photon interactions in the ΔHU–ρ{sub e} conversion process. Methods: The authors performed numerical analyses of the ΔHU–ρ{sub e} conversion for 105 human body tissues, as listed in ICRU Report 46, and elementary substances with Z = 1–40. Total and partial attenuation coefficients for these materials were calculated using the XCOM photon cross section database. The effective x-ray energies used to calculate the attenuation were chosen to imitate a dual-source CT scanner operated at 80–140 kV/Sn under well-calibrated and poorly calibrated conditions. Results: The accuracy of the resultant calibrated electron density,ρ{sub e}{sup cal}, for the ICRU-46 body tissues fully satisfied the IPEM-81 tolerance levels in radiotherapy treatment planning. If a criterion of ρ{sub e}{sup cal}/ρ{sub e} − 1 is assumed to be within ±2%, the predicted upper limit of Z applicable for the ΔHU–ρ{sub e} conversion under the well-calibrated condition is Z = 27. In the case of the poorly calibrated condition, the upper limit of Z is approximately 16. The deviation from the ΔHU–ρ{sub e} linearity for higher Z substances is mainly caused by the anomalous variation in the photoelectric-absorption component. Conclusions: Compensation among the three partial components of the photon interactions provides for sufficient linearity of the ΔHU–ρ{sub e} conversion to be applicable for most human tissues even for poorly conditioned scans in which there exists a large variation of effective x-ray energies owing to beam-hardening effects arising from the mismatch between the sizes of the object and the calibration phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-202-02: A Preliminary Study Evaluating Beam-Hardening Artifact Reduction On CT Direct Electron-Density Images

Purpose: A prototype reconstruction algorithm that can provide direct electron density (ED) images from single energy CT scans is being currently developed by Siemens Healthcare GmbH. This feature can eliminate the need for kV specific calibration curve for radiation treatemnt planning. An added benefit is that beam-hardening artifacts are also reduced on direct-ED images due to the underlying material decomposition. This study is to quantitatively analyze the reduction of beam-hardening artifacts on direct-ED images and suggest additional clinical usages. Methods: HU and direct-ED images were reconstructed on a head phantom scanned on a Siemens Definition AS CT scanner at five tube potentials of 70kV, 80kV, 100kV, 120kV and 140kV respectively. From these images, mean, standard deviation (SD), and local NPS were calculated for regions of interest (ROI) of same locations and sizes. A complete analysis of beam-hardening artifact reduction and image quality improvement was conducted. Results: Along with the increase of tube potentials, ROI means and SDs decrease on both HU and direct-ED images. The mean value differences between HU and direct-ED images are up to 8% with absolute value of 2.9. Compared to that on HU images, the SDs are lower on direct-ED images, and the differences are up to 26%. Interestingly, the local NPS calculated from direct-ED images shows consistent values in the low spatial frequency domain for images acquired from all tube potential settings, while varied dramatically on HU images. This also confirms the beam -hardening artifact reduction on ED images. Conclusions: The low SDs on direct-ED images and relative consistent NPS values in the low spatial frequency domain indicate a reduction of beam-hardening artifacts. The direct-ED image has the potential to assist in more accurate organ contouring, and is a better fit for the desired purpose of CT simulations for radiotherapy.

60 APPLIED LIFE SCIENCES↗

Alternative trajectories of electron density to plot the atomic connectivity graph in the region of nondirectional interactions

Model supramolecular associates possessing nondirectional intermolecular interactions were investigated in order to demonstrate the opportunity of plotting of an atomic connectivity graph based on trajectories of Hessian eigenvector of electron density corresponding to the largest eigenvalue. Such trajectories are a reasonable alternative to the gradient bond paths in the case of proximity of the latter to the T-shaped form upon the presence of parallel surface of the zero-flux of electron density in the neighborhood of gradient-based trajectory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser collisional induced fluorescence electron density measurements as a function of ring bias and the onset of anode spot formation in a ring cusp magnetic field

In this paper, two-dimensional electron density measurements are made in a magnetic ring cusp discharge using laser collisional induced fluorescence. The magnet rings are isolated from the anode structure such that they can be biased independently in order to modulate electron flows through the magnetic cusps. Electron density images are captured as a function of bias voltage in order to assess the effects of current flow through the cusp on the spatial extent of the cusp. We anticipated that for a fixed current density being funneled through the magnetic cusp, the leak width would necessarily increase. Unexpectedly, the leak width, as measured by LCIF images, does not increase. This suggests that the current density is not constant, and that possibly either electrons are being heated or additional ionization events are occurring within the cusp. Spatially resolving electron temperature would be needed to determine if electrons are being heated within the cusp. Finally, we also observe breakdown of the anode magnetosheath and formation of anode spots at high bias voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Differential equation for the Dirac single-particle first-order density matrix in terms of the ground-state electron density

The March-Suhai (MS) partial differential equation for the Dirac density matrix {gamma}{sub s}(r,r'), proved for one- and two-level occupancies, involves both the ground-state density n(r), with its low-order derivatives, and the positive definite kinetic energy density t{sub s}(r). Here, we examine the relation between the equation of motion for {gamma}{sub s}(r,r'), with input now being the one-body potential of density-functional theory, and the MS equation. The important link is the differential virial theorem, which can be used to remove t{sub s}(r) from the MS differential equation. For multiple occupancy, the Pauli potential enters in an important manner. In one dimension, however, the appearance of the Pauli potential can be avoided, obtaining a necessary condition for {gamma}{sub s}(x,x{sup '}) to satisfy for arbitrary level occupancy, in the form of a MS-type differential equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency effects on the electron density and {alpha}-{gamma} mode transition in atmospheric radio frequency discharges

In this paper, a one-dimensional model is explored to investigate the frequency effects on the characteristics of atmospheric radio frequency discharges at a given power. The simulation data and analytical results show that the improvement of electron density can be observed with better discharge stability by increasing excitation frequency in an appropriate range. Using the analytical equations deduced from the model, the mean electron density could be inferred by means of the measured parameters. The {alpha}-{gamma} mode transition especially in high frequency discharges is also analytically discussed based on the theoretical equations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements in the order, isotropy and electron density of glypican-1 crystals by controlled dehydration

The anisotropy of crystals of glypican-1 was significantly reduced by controlled dehydration using the HC1 device, allowing the building of previously disordered parts of the structure. The use of controlled dehydration for improvement of protein crystal diffraction quality is increasing in popularity, although there are still relatively few documented examples of success. A study has been carried out to establish whether controlled dehydration could be used to improve the anisotropy of crystals of the core protein of the human proteoglycan glypican-1. Crystals were subjected to controlled dehydration using the HC1 device. The optimal protocol for dehydration was developed by careful investigation of the following parameters: dehydration rate, final relative humidity and total incubation time T{sub inc}. Of these, the most important was shown to be T{sub inc}. After dehydration using the optimal protocol the crystals showed significantly reduced anisotropy and improved electron density, allowing the building of previously disordered parts of the structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diagnostics principle of microwave cut-off probe for measuring absolute electron density

A generalized diagnostics principle of microwave cut-off probe is presented with a full analytical solution. In previous studies on the microwave cut-off measurement of weakly ionized plasmas, the cut-off frequency ω{sub c} of a given electron density is assumed to be equal to the plasma frequency ω{sub p} and is predicted using electromagnetic simulation or electric circuit model analysis. However, for specific plasma conditions such as highly collisional plasma and a very narrow probe tip gap, it has been found that ω{sub c} and ω{sub p} are not equal. To resolve this problem, a generalized diagnostics principle is proposed by analytically solving the microwave cut-off condition Re[ε{sub r,eff}(ω = ω{sub c})] = 0. In addition, characteristics of the microwave cut-off condition are theoretically tested for correct measurement of the absolute electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous streak and frame interferometry for electron density measurements of laser produced plasmas

A system of two collinear probe beams with different wavelengths and pulse durations was used to capture simultaneously snapshot interferograms and streaked interferograms of laser produced plasmas. The snapshots measured the two dimensional, path-integrated, electron density on a charge-coupled device while the radial temporal evolution of a one dimensional plasma slice was recorded by a streak camera. This dual-probe combination allowed us to select plasmas that were uniform and axisymmetric along the laser direction suitable for retrieving the continuous evolution of the radial electron density of homogeneous plasmas. Demonstration of this double probe system was done by measuring rapidly evolving plasmas on time scales less than 1 ns produced by the interaction of femtosecond, high intensity, laser pulses with argon gas clusters. Experiments aimed at studying homogeneous plasmas from high intensity laser-gas or laser-cluster interaction could benefit from the use of this probing scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field-aligned electron density irregularities near 500 km Equator to polar cap topside sounder observations

In addition to spread F, evidence for field-aligned electron density irregularities is commonly observed on Alouette 2 topside sounder ionograms recorded near perigee (500 km). This evidence is provided by distinctive signal returns from sounder-generated Z mode waves. At low latitudes these waves become guided in wave ducts caused by field-aligned electron density irregularities and give rise to strong long-duration echoes. At high latitudes, extending well into the polar cap, these Z mode waves (and stimulated electrostatic waves at the plasma frequency) produce a series of vertical bars on the ionogram display as the satellite traverses discrete field-aligned density structures. The radio frequency (RF) noise environment to be expected in the 400 to 500 km altitude region from low to high latitudes was examined by analyzing perigee Alouette 2 topside sounder data. All observed noise bands were scaled on nearly 200 topside sounder ionograms recorded near perigee at low, mid, and high latitude telemetry stations. The minimum and maximum frequencies of each noise band were entered into a data base or computer analysis. The signals of primary interest in the perigee study were found to be sounder-generated.

Benson, R. F.↗

Rocket measurements of ion and electron densities in the D-region during sunrise.

Results from two rockets launched near sunrise at White Sands, N. Mex., when positive ion and electron densities were measured in the D-region for solar zenith angles of 91 and 79 deg. The measurements cover the height range 80 to 110 km and complement previous vlf observations and rocket measurements of electron density. It is shown that the majority of negative ions in this height range are detached near to after ground sunrise. On the basis of these measurements it is possible to discuss electron affinity of negative ions and ion production functions during twilight.

Pedersen, A.↗