Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Thermal Analysis of Wireless Power Transfer Coils for Dynamic Wireless Electric Vehicle Charging

In this paper, safe operating conditions of a wireless power transfer coil were identified and road infrastructure for a dynamic wireless electric vehicle charging system was studied. Magneto-thermal simulations were used to map the power loss directly into the computed fluid dynamics solver. This method allowed the authors to analyze the heating pattern of the enclosed wireless power transfer coil in the road structure, as well as for the vehicle coil. Thermal heating patterns for three types of rectangular coil structures were analyzed. Heating patterns were analyzed for 200 kW coils and different magnetic field densities in the magnetic core.

Wojda, Rafal↗

Computer Simulation Performed for Columbia Project Cooling System

This demo shows a high-fidelity simulation of the air flow in the main computer room housing the Columbia (10,024 intel titanium processors) system. The simulation asseses the performance of the cooling system and identified deficiencies, and recommended modifications to eliminate them. It used two in house software packages on NAS supercomputers: Chimera Grid tools to generate a geometric model of the computer room, OVERFLOW-2 code for fluid and thermal simulation. This state-of-the-art technology can be easily extended to provide a general capability for air flow analyses on any modern computer room. Columbia_CFD_black.tiff

Ahmad, Jasim↗

Pulsed laser generation of ultrasound in a metal plate between the melting and ablation thresholds

The generation of ultrasound in a metal plate exposed to nanosecond pulsed laser heating, sufficient to cause melting but not ablation, is treated. Consideration is given to the spatial and temporal profiles of the laser pulse, penetration of the laser beam into the sample, the evolution of the melt pool, and thermal conduction in the melt and surrounding solid. The excitation of the ultrasound takes place over a few nanoseconds, and occurs predominantly within the thermal diffusion length of a micron or so beneath the surface. Because of this, the output of the thermal simulations can be represented as axially symmetric transient radial and normal surface force distributions. The epicentral displacement response at the opposite surface to these forces is obtained by two methods, the one based on the elastodynamic Green’s functions for plate geometry determined by the Cagniard generalized ray method, and the other using a finite element numerical method. The two approaches are in very close agreement. Numerical simulations are reported of the epicentral displacement response of a 3.12mm thick tungsten plate irradiated with a 4 ns pulsed laser beam with Gaussian spatial profile, at intensities below and above the melt threshold. Comparison is made between results obtained using available temperature dependent thermophysical data, and room temperature materials constants except near the melting point.

36 MATERIALS SCIENCE↗

xEMU Thermal Vacuum Testing Overview

The Exploration Extravehicular Mobility Unit (xEMU) project was the culimation of over a decade of spacesuit development that was performed in-house at the NASA Johnson Space Center. This project reached a level where almost fully completed development fidelity spacesuits had been designed, assembled and tested in an integrated configuration. The xEMU Development-Verification-Test (DVT) hardware was assembled into two different xEMU test articles and underwent a series of thermal-vacuum tests at the Johnson Space Center’s Chamber B. These tests not only gathered data on thermal performance, but also exercised the life support system, communication system, suit information systems, and suit avionics. This complex test has and will continue to produce many meaningful reports ranging from component level test results (for example on spacesuit boots), test design of heater cages to simulate thermal environments for a spacesuit test article, and higher level thermal performance of subsystems (such as the Portable Life Support System) or the entire assembly. This paper provides an overview of the test configuration and also top level results from this highly successful integrated test of the xEMU.

PLSS↗

xEMU Thermal Vacuum Testing Overview

The Exploration Extravehicular Mobility Unit (xEMU) project was the culimation of over a decade of spacesuit development that was performed in-house at the NASA Johnson Space Center. This project reached a level where almost fully completed development fidelity spacesuits had been designed, assembled and tested in an integrated configuration. The xEMU Development-Verification-Test (DVT) hardware was assembled into two different xEMU test articles and underwent a series of thermal-vacuum tests at the Johnson Space Center’s Chamber B. These tests not only gathered data on thermal performance, but also exercised the life support system, communication system, suit information systems, and suit avionics. This complex test has and will continue to produce many meaningful reports ranging from component level test results (for example on spacesuit boots), test design of heater cages to simulate thermal environments for a spacesuit test article, and higher level thermal performance of subsystems (such as the Portable Life Support System) or the entire assembly. This paper provides an overview of the test configuration and also top level results from this highly successful integrated test of the xEMU.

PLSS↗

Online thermal profile prediction for large format additive manufacturing: A hybrid CNN-LSTM based approach

Large format additive manufacturing (LFAM) is an advanced 3D printing technique that efficiently fabricates large-scale components through a layer-by-layer extrusion and deposition process. Accurate surface layer temperature monitoring is essential to prevent manufacturing failures and ensure final product quality. Traditional physics-based offline approaches for simulating thermal behavior are often inefficient and complex, posing challenges on real-time, in-situ monitoring. Here, to address this, we propose a data-driven hybrid CNN-LSTM model to predict sequential thermal images of arbitrary length using real-time infrared thermal imaging. In this approach, a Convolutional Neural Networks (CNN) is trained offline to capture spatial features, reduce dimensional complexity, and enhance time efficiency, while a stacked Long Short-Term Memory (LSTM) is applied online to capture temporal information for improved prediction of future thermal behavior in subsequent printing layers. Model performance is evaluated using MSE, SSIM, and PSNR metrics and is benchmarked against stacked LSTM and convolutional LSTM models, demonstrating superior accuracy and applicability. Additionally, to mitigate noise from moving extruders and gantry backgrounds in thermal images, a fine-tuned semantic segmentation model is implemented offline to extract printing geometry, enabling precise temperature tracking along the tool path for further thermal analysis. The frameworks developed in this study significantly advance temperature monitoring, thermal analysis, and in-situ manufacturing control for LFAM, bridging the gap between theoretical modeling and practical application.

Geometry extraction↗

DC Microgrid Reliability Enhancement with Adaptive Converter Thermal Management

Due to the different device selections, aging levels, and thermal dissipation performance, some converters may take additional thermal stress on switching devices than others in paralleled converter systems, which will reduce system reliability. To address this problem, this paper proposes a power-sharing strategy with adaptive thermal management. First, the temperature-based power loss model and electrical-thermal model are established. Based on that, a high-accuracy IGBT junction temperature estimate considering the power loss-temperature coupling can be achieved. Further, the thermal-sharing for all the switching devices in paralleled converters can be achieved with the proposed adaptive thermal management strategy. The proposed strategy can change the power-sharing ratio adaptively according to the system operation conditions, which will contribute to the system reliability enhancement. The effectiveness of the proposed strategy is verified through PLECS thermal simulation and joint real-time simulation with Dspace and RT-box.

DC microgrid↗

Influences and Interactions of Inundation, Peat, and Snow on Active Layer Thickness: Modeling Archive

The Advanced Terrestrial Simulator was used to simulate thermal hydrological conditions across varied environmental conditions for an ensemble of 1D models of Arctic permafrost. The thickness of organic soil is varied from 2 to 40cm, snow depth is varied from approximately 0 to 1.2 meters, water table depth was varied from -51cm below the soil surface to 31 cm above the soil surface. A total of 15,960 ensemble members are included. Data produced includes the third and fourth simulation year: active layer thickness, time of deepest thaw depth, temperature of the unfrozen soil, and unfrozen liquid saturation, for each ensemble member. Input files used to run the ensemble are also included. File formats in the data package: .py, .h5, .xml, .exo, .txt, and .pdf.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Thermal relaxation of a two dimensional plasma in a dc magnetic field. Part 2: Numerical simulation

The thermal relaxation process for a spatially uniform two dimensional plasma in a uniform dc magnetic field is simulated numerically. Thermal relaxation times are defined in terms of the time necessary for the numerically computer Boltzman H-function to decrease through a given part of the distance to its minimum value. Dependence of relaxation time on two parameters is studied: number of particles per Debye square and ratio of gyrofrequency to plasma frequency.

Hsu, J. Y.↗

Full-Scale System for Quantifying Loads and Leak Rates of Seals for Space Applications

NASA is developing advanced space-rated vacuum seals in support of future space exploration missions to low-Earth orbit and other destinations. These seals may be 50 to 60 in. (127 to 152 cm) in diameter and must exhibit extremely low leak rates to ensure that astronauts have sufficient breathable air for extended missions to the International Space Station or the Moon. Seal compression loads must be below prescribed limits so as not to overload the mechanisms that compress them during docking or mating, and seal adhesion forces must be low to allow two mated systems to separate when required. NASA Glenn Research Center has developed a new test apparatus to measure leak rates and compression and adhesion loads of candidate full-scale seals under simulated thermal, vacuum, and engagement conditions. Tests can be performed in seal-on-seal or seal-on-flange configurations at temperatures from -76 to 140 F (-60 to 60 C) under operational pressure gradients. Nominal and off-nominal mating conditions (e.g., incomplete seal compression) can also be simulated. This paper describes the main design features of the test apparatus as well as techniques used to overcome some of the design challenges.

Dunlap, Patrick H., Jr.↗

A quasi-static Monte Carlo algorithm for the simulation of sub-prompt critical transients

A pseudo-time-dependent Monte Carlo algorithm suitable for simulating thermal reactor transients with timescales on the order of seconds is presented. An initial experimental implementation has been written into the Monte Carlo Application ToolKit (MCATK) developed at Los Alamos National Laboratory. The algorithm is essentially a combination of the fully time-dependent Monte Carlo algorithm, including the explicit simulation of delayed neutron precursors, and a quasi-static algorithm that does not use the point-kinetics equations. The fully time-dependent calculation is performed for some number of inactive and active micro time steps. The dynamic reactor time constant and delayed neutron precursor production rates are calculated directly from the active cycles, rather than from point-kinetics parameters. These quantities are then used to advance the neutron population and delayed neutron precursors forward in time across a macro time step. As a result, the method is applied to the C5G7-TD benchmark operating in steady state and in transient mode.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Test Facilities in Support of High Power Electric Propulsion Systems

Successful development of space fission systems requires an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system performance and lifetime can be attained through non-nuclear testing. Through demonstration of systems concepts (designed by DOE National Laboratories) in relevant environments, this philosophy has been demonstrated through hardware testing in the High Power Propulsion Thermal Simulator (HPPTS). The HPPTS is designed to enable very realistic non-nuclear testing of space fission systems. Ongoing research at the HPPTS is geared towards facilitating research, development, system integration, and system utilization via cooperative efforts with DOE labs, industry, universities, and other NASA centers. Through hardware based design and testing, the HPPTS investigates High Power Electric Propulsion (HPEP) component, subsystem, and integrated system design and performance.

VanDyke, Melissa↗

Layer Time Control for Large Scale Additive Manufacturing Using High Performance Computing

This work proposes to optimize an additive manufacturing AM process to reduce energy and printing cost. The polymer AM process is inherently dependent on the time-temperature history of each layer to maintain geometric tolerances and mechanical integrity. Our preliminary study shows that regression-based layer time control model using thermal images could result in up to 30% build time reduction for simple geometries. This proposed work would use high-performance computing (HPC) to couple the data-driven model with thermal simulation for better predicting layer temperature profiles, improving throughput of large-scale additive manufacturing, and reducing its energy cost. We have developed a method to optimize a layer deposition time (a.k.a. layer time) for large-scale AM via physics-based simulations. A long layer time leads to an over-cooled surface on which a new layer is deposited, and therefore, it may result in a weak bonding or debonding between layers, cracking, or warping. A short layer time leads to a high temperature of the structure due to insufficient cooling, and therefore, the structure may not be stiff enough and may collapse during manufacturing. Therefore, it is important to estimate the optimal layer time in additive manufacturing for a high-quality product. The temperature of a top layer right before deposition is recommended to be slightly higher than the glass temperature of the material. A temperature cooling was approximated to an exponential function of time, and the optimized layer time was obtained based on a target temperature while maintaining a minimal printing time. The material used is carbon fiber-reinforced polycarbonate (CF/PC), and the large-scale deposition system used is LSAM TM from Thermwood Corporation. Three different layer time cases were used for experiments, and a series of thermal images were obtained via an infra-red (IR) camera during the entire AM processes. AM process simulations were performed using a finite element method and the temperature profiles from the simulation were in good agreements with those from experiments. The layer time optimization was performed based on the temperature profiles from the simulations. A layer temperature with the optimal layer time was confirmed as the target temperature through simulation. In addition to the development of a layer time optimization method, we have developed a numerical framework for AM simulation with element activations in sync with toolpath, based on an open source finite element framework, DEAL.II. A major portion of this work was presented at SAMPE 2022 Conference and Exhibition on May 2022, and published in Proceedings of SAMPE 2022.

42 ENGINEERING↗

Orbiter TPS development and certification testing at the NASA/JSC 10 MW Atmospheric Reentry Materials and Structures Evaluation Facility

Thermal performance of the Space Shuttle Orbiter Thermal Protection System (TPS) has been verified by extensive ground testing at the NASA/JSC 10 MW Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF). Major test programs have included current TPS materials (RSI, RCC and ablators) and advanced TPS materials (AFRSI and FRCI-12). Testing by electrically heating a gas mixture simulating air and expanding it (supersonically or hypersonically) through channel or conical nozzles has produced simulated thermal and pressure environments on models representative of the Orbiter TPS acreage and penetration regions. Tests have established Orbiter TPS thermal design requirements, verified Orbiter TPS thermal performance, and supported Orbiter TPS flight anomaly investigations and resolutions.

Rochelle, W. C.↗

Simulations for Field-Enhanced Conduction-Cooled Superconducting RF Electron Source

We present a novel RF design for a field enhanced electron source driven by field emission cathodes. The proposed electron source relies on the enhanced high electric field gradients at the cathode to simultaneously extract and accelerate electrons. The system will be tested in a conduction-cooled superconducting radiofrequency cavity recently demonstrated at Fermilab. In this work, we present electromagnetic and thermal simulations of the setup that support the feasibility of the design.

43 PARTICLE ACCELERATORS↗

Low-E Retrofit Demonstration and Educational Program

The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment air leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low-E performed better than the other. COMMERCIAL CASE STUDIES: (a) A 12-story office building in Philadelphia was retrofitted by adding a double-pane low-E insulating glass unit to the existing single pane windows, to create a triple glazed low-E system. A detailed side-by-side comparison in two pairs of perimeter offices facing north and east showed a 39-60% reduction in heating energy use, a 9-36% reduction in cooling energy use, and a 10% reduction in peak electrical cooling demand. An analysis of utility bills estimated the whole building heating and cooling energy use was reduced by over 25%. Additionally, the retrofit window temperatures were commonly 20 degrees warmer on winter days, and 10-20 degrees cooler on summer days, leading to increased occupant comfort. (b) Two large 4-story office buildings in New Jersey were retrofitted with a similar system, but using two low-E coatings in the retrofit system. The energy savings are being monitored by a separate GPIC project; this work quantified the changes in glass surface temperatures, thermal comfort, and potential glass thermal stress. The low-E retrofit panels greatly reduced daily variations in the interior window surface temperatures, lowering the maximum temperature and raising the minimum temperature by over 20F compared to the original single pane windows with window film. The number of hours of potential thermal discomfort, as measured by deviation between mean radiant temperature and ambient air temperature by more than 3F, were reduced by 93 percent on the south orientation and over two-thirds on the west orientation. Overall, the low-E retrofit led to substantially improved occupant comfort with less periods of both overheating and feeling cold. (c) No significant thermal stress was observed in the New Jersey office building test window when using the low-E retrofit system over a variety of weather conditions. The surface temperature difference only exceeded 10F (500 psi thermal stress) for less than 1.5% of the monitored time, and in all cases, the maximum surface temperature difference never exceeded 35F (1,750 psi thermal stress). LOW-E STORM WINDOW OUTREACH AND EDUCATION PROGRAM: (a) The project team assisted the State of Pennsylvania in adding low-E storm windows as a cost effective weatherization measure on its priority list for the state weatherization assistance program. (b) No technical barriers that could hinder widespread application were identified in the case studies. However, educational barriers have been identified, in that weatherization personnel commonly misunderstand how the application of low-E storm windows is very different than much more expensive full window replacement. (c) A package of educational materials was developed to help communicate the benefits of low-E storm windows and retrofits as a cost effective tool for weatherization personnel. (d) Using detailed thermal simulations, more accurate U-factor and solar heat gain coefficient (SHGC) values were determined for low-E storm windows installed over different primary windows. IN SUMMARY, this work confirmed the potential for low-E storm windows, panels, and retrofit systems to provide significant energy savings, reductions in air leakage, and improvements in thermal comfort in both residential and commercial existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fatigue-test acceleration with flight-by-flight loading and heating to simulate supersonic-transport operation

Possibilities for reducing fatigue-test time for supersonic-transport materials and structures were studied in tests with simulated flight-by-flight loading. In order to determine whether short-time tests were feasible, the results of accelerated tests (2 sec per flight) were compared with the results of real-time tests (96 min per flight). The effects of design mean stress, the stress range for ground-air-ground cycles, simulated thermal stress, the number of stress cycles in each flight, and salt corrosion were studied. The flight-by-flight stress sequences were applied to notched sheet specimens of Ti-8Al-1Mo-1V and Ti-6Al-4V titanium alloys. A linear cumulative-damage analysis accounted for large changes in stress range of the simulated flights but did not account for the differences between real-time and accelerated tests. The fatigue lives from accelerated tests were generally within a factor of two of the lives from real-time tests; thus, within the scope of the investigation, accelerated testing seems feasible.

Imig, L. A.↗

Advanced Signal Processing for Integrated LES-RANS Simulations: Anti-aliasing Filters

Currently, a wide variety of flow phenomena are addressed with numerical simulations. Many flow solvers are optimized to simulate a limited spectrum of flow effects effectively, such as single parts of a flow system, but are either inadequate or too expensive to be applied to a very complex problem. As an example, the flow through a gas turbine can be considered. In the compressor and the turbine section, the flow solver has to be able to handle the moving blades, model the wall turbulence, and predict the pressure and density distribution properly. This can be done by a flow solver based on the Reynolds-Averaged Navier-Stokes (RANS) approach. On the other hand, the flow in the combustion chamber is governed by large scale turbulence, chemical reactions, and the presence of fuel spray. Experience shows that these phenomena require an unsteady approach. Hence, for the combustor, the use of a Large Eddy Simulation (LES) flow solver is desirable. While many design problems of a single flow passage can be addressed by separate computations, only the simultaneous computation of all parts can guarantee the proper prediction of multi-component phenomena, such as compressor/combustor instability and combustor/turbine hot-streak migration. Therefore, a promising strategy to perform full aero-thermal simulations of gas-turbine engines is the use of a RANS flow solver for the compressor sections, an LES flow solver for the combustor, and again a RANS flow solver for the turbine section.

Schlueter, J. U.↗