Engineering Papers⌕ Search

NASA NTRS · 20240000686

xEMU Thermal Vacuum Testing Overview

Abstract

The Exploration Extravehicular Mobility Unit (xEMU) project was the culimation of over a decade of spacesuit development that was performed in-house at the NASA Johnson Space Center. This project reached a level where almost fully completed development fidelity spacesuits had been designed, assembled and tested in an integrated configuration. The xEMU Development-Verification-Test (DVT) hardware was assembled into two different xEMU test articles and underwent a series of thermal-vacuum tests at the Johnson Space Center’s Chamber B. These tests not only gathered data on thermal performance, but also exercised the life support system, communication system, suit information systems, and suit avionics. This complex test has and will continue to produce many meaningful reports ranging from component level test results (for example on spacesuit boots), test design of heater cages to simulate thermal environments for a spacesuit test article, and higher level thermal performance of subsystems (such as the Portable Life Support System) or the entire assembly. This paper provides an overview of the test configuration and also top level results from this highly successful integrated test of the xEMU.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David Westheimer, Liana Rodriggs, Eric A Falconi, Ben J Swartout, Michael Lewandowski. 2024-07-21. xEMU Thermal Vacuum Testing Overview. https://ntrs.nasa.gov/citations/20240000686

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

EMU Ventilation Loop Simulation and Assessment of Contamination of the EMU Sublimator Hydrophilic Coating

Controlling moisture is a critical function performed in the space suit during extra vehicular activity (EVA) missions. Currently, this function is carried out by a sublimator, which is coated with a hydrophilic material. Tests have shown that siloxane compounds can off gas from the helmet absorption pad extension (HAP-E) and helmet absorption band (HAB) when they are at elevated temperatures and initial testing indicated that siloxanes could damage the hydrophilic coating. Therefore, more representative testing was needed. Important test considerations were source and destination kinetics, system geometries, scrubbing efficacy by the activated charcoal from the Metox canister, and other benefits that derive from active condensation occurring on the hydrophilic coating during exposure. A ventilation loop that was originally constructed to test hardware for control of CO2 and trace contaminants under EVA conditions was modified to conduct the siloxane off gassing tests. A vacuum compatible acrylic chamber was installed to simulate the suit volume. A steel beaker located in the chamber contained the HAP-E and HAB materials and was heated with two band heaters. The flow exiting the chamber passed through a LiOH cannister, which contained carbon beds to simulate their function in the Metox. The flow then was directed into a smaller volume that contained a coupon, which was coated with the hydrophilic material and was maintained at 10°C (50°F). Moisture was injected upstream of the suit volume simulator to maintain the dew point between 12.7°C (55°F) and 18.3°C (65°F). The pressure was controlled to between 3.8 and 4.4 psia, and the flow was held at 6 acfm. The system was run for an equivalent of 25 ten-hour EVAs, where the HAP-E/HAB materials were changed out after each EVA. The effect of the potential off gassing on the coupon was measured after each EVA period.

PLSS↗

Analytical Review of Exploration Extravehicular Mobility Unit Heat Rejection Performance

The Primary Thermal Control Loop (PTCL) in the Exploration Extravehicular Mobility Unit (xEMU) uses a Spacesuit Water Membrane Evaporator (SWME) to provide cooling for the crew member and spacesuit avionics. A secondary emergency cooling system, the Auxiliary Thermal Control Loop (ATCL), also uses a smaller version of the SWME, called the Mini-ME, in the event of a failure in the primary system. These are integral to the comfort of the crew member (through heat rejection) during an Extravehicular Activity (EVA). This paper examines the effectiveness of the heat rejection of the PTCL and the ATCL during thermal vacuum testing and the absolute limit of heat rejection to maintain an approximately 10C outlet temperature. During this thermal vacuum test, the PTCL was taken from a heat input of 0W up to 900W, far past the design point, and the ATCL was tested from 0W to 300W. Testing showed that the PTCL and the ATCL can maintain crew member outlet temperature throughout an entire 8-hour thermally controlled EVA environment (hot and cold). The results and effectiveness of the test will be detailed throughout this paper for all EVAs (whether a full mapping profile or a standard continuous heat load).

PLSS↗

xEMU Thermal Vacuum Testing Overview

The Exploration Extravehicular Mobility Unit (xEMU) project was the culimation of over a decade of spacesuit development that was performed in-house at the NASA Johnson Space Center. This project reached a level where almost fully completed development fidelity spacesuits had been designed, assembled and tested in an integrated configuration. The xEMU Development-Verification-Test (DVT) hardware was assembled into two different xEMU test articles and underwent a series of thermal-vacuum tests at the Johnson Space Center’s Chamber B. These tests not only gathered data on thermal performance, but also exercised the life support system, communication system, suit information systems, and suit avionics. This complex test has and will continue to produce many meaningful reports ranging from component level test results (for example on spacesuit boots), test design of heater cages to simulate thermal environments for a spacesuit test article, and higher level thermal performance of subsystems (such as the Portable Life Support System) or the entire assembly. This paper provides an overview of the test configuration and also top level results from this highly successful integrated test of the xEMU.

PLSS↗