Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Skylab-EREP studies in computer mapping of terrain in the Cripple Creek-Canon City area of Colorado

Multispectral-scanner data from satellites are used as input to computers for automatically mapping terrain classes of ground cover. Some major problems faced in this remote-sensing task include: (1) the effect of mixtures of classes and, primarily because of mixtures, the problem of what constitutes accurate control data, and (2) effects of the atmosphere on spectral responses. The fundamental principles of these problems are presented along with results of studies of them for a test site of Colorado, using LANDSAT-1 data.

Smedes, H. W.↗

Inflight Rotor Stability Monitor

An inflight rotor stability monitor developed at Sikorsky Aircraft to support stability testing of new rotorcraft is described. The monitor has as its core a damping estimation algorithm which embodies spectral analysis techniques. The interactive system is activated and controlled from a cathode ray tube (CRT) and operates on-line in a flight test telemetry environment. Accurate estimates of the level of damping of critical system modes are generated within one minute of the completion of a prescribed test maneuver. The stability monitor was used successfully to support various Sikorsky research and development flight programs including the UTTAS, CH-53E, S-67 Fan-in-Fin, and ABC.

Kuczynski, W. A.↗

A three-D circulation model study of the radiative-dynamic coupling within the stratosphere

The role of radiative transfer processes in the general circulation of the stratosphere was studied by comparing the thermal and dynamical structure of the stratosphere as simulated by two controlled numerical experiments performed with the aid of a spectral 3-dimensional quasi-geostrophic circulation model. In the first experiment, a detailed radiative transfer model is employed to treat the longwave radiative transfer in the stratosphere. In the second experiment, longwave radiative transfer is accounted for by employing the Newtonian cooling approximation. It is found that the exchange of longwave radiation between the troposphere and lower stratosphere has a net heating effect on the lower stratosphere. It is shown that this heating effect contributes partly to the maintenance of the warm high-latitude belt in the lower stratosphere during winter and spring seasons. The strong temperature dependence of the Newtonian cooling coefficient plays an important role in determining the zonal temperatures and has a significant influence on the transmissivity of stratosphere to propagating planetary scale waves.

Ramanathan, V.↗

Baseband-processed SS-TDMA communication system architecture and design concepts

The architecture and system design for a commercial satellite communications system planned for the 1990's was developed by Motorola for NASA's Lewis Research Center. The system provides data communications between individual users via trunking and customer premises service terminals utilizing a central switching satellite operating in a time-division multiple-access (TDMA) mode. The major elements of the design incorporating baseband processing include: demand-assigned multiple access reservation protocol, spectral utilization, system synchronization, modulation technique and forward error control implementation. Motorola's baseband processor design, which is being proven in a proof-of-concept advanced technology development, will perform data regeneration and message routing for individual users on-board the spacecraft.

Attwood, S.↗

Lidar instruments proposed for Eos

Lidar, an acronym for light detection and ranging, represents a class of instruments that utilize lasers to send probe beams into the atmosphere or onto the surface of the Earth and detect the backscattered return in order to measure properties of the atmosphere or surface. The associated technology has matured to the point where two lidar facilities, Geodynamics Laser Ranging System (GLRS), and Laser Atmospheric Wind Sensor (LAWS) were accepted for Phase 2 studies for Eos. A third lidar facility Laser Atmospheric Sounder and Altimeter (LASA), with the lidar experiment EAGLE (Eos Atmospheric Global Lidar Experiment) was proposed for Eos. The generic lidar system has a number of components. They include controlling electronics, laser transmitters, collimating optics, a receiving telescope, spectral filters, detectors, signal chain electronics, and a data system. Lidar systems that measure atmospheric constituents or meteorological parameters record the signal versus time as the beam propagates through the atmosphere. The backscatter arises from molecular (Rayleigh) and aerosol (Mie) scattering, while attenuation arises from molecular and aerosol scattering and absorption. Lidar systems that measure distance to the Earth's surface or retroreflectors in a ranging mode record signals with high temporal resolution over a short time period. The overall characteristics and measurements objectives of the three lidar systems proposed for Eos are given.

Grant, William B.↗

Wide-angle astrometry with the Mark III stellar interferometer

Astrometric measurements made with the Mark III stellar interferometer on five nights in August-September 1988 yielded average formal 1-sigma errors for 12 FK5 stars of 6 mas in declination and 10 mas in right ascension. This improvement in precision over previously reported measurements with this instrument made in 1986 is attributable to several factors: a second 12 m baseline; oriented E-S, was added to the instrument to improve the determination of right ascension; two-color analysis was included in the data-reduction process, along with a new central-fringe identification algorithm using three spectral channels, in order to reduce atmospheric errors; thermal control was greatly improved; and changes were made to observational procedures and hardware to monitor variations in the delay offset due to residual thermal drifts. Approximately half of the new positions are within 50 mas of their FK5 positions. However, an extended series of measurements are needed to ascertain the accuracy that can be achieved by interferometry.

Shao, M.↗

Nonscanning climate sensor study

The Nonscanning Climate Sensor represents a new instrument for climate research and global monitoring of the earth radiation budget. It contains a mosaic of array of detectors which measures the outgoing radiation of the earth in all directions without the need for mechanical scanning. The goal is to eliminate all moving parts and obtain highly calibrated measurements for up to one solar cycle (11 years) without being susceptible to mechanical failure. Over set intervals of time, the angular measurements are integrated up to produce total reflected and emitted flux values from each target area on the Earth. To achieve the require sensitivity while maintaining a flat spectral response, an improved dual cavity detector with digital control loop was developed. The detector is self calibrating to maintain high precision over the life of the instrument. Prototype detectors and a complete set of electronics with a microprocessor controller were fabricated and tested. Measurements show that the new detectors are more than an order of magnitude more sensitive than previous versions.

Hoffman, James W.↗

Three-Dimensional High-Order Spectral Finite Volume Method for Unstructured Grids

Many areas require a very high-order accurate numerical solution of conservation laws for complex shapes. This paper deals with the extension to three dimensions of the Spectral Finite Volume (SV) method for unstructured grids, which was developed to solve such problems. We first summarize the limitations of traditional methods such as finite-difference, and finite-volume for both structured and unstructured grids. We then describe the basic formulation of the spectral finite volume method. What distinguishes the SV method from conventional high-order finite-volume methods for unstructured triangular or tetrahedral grids is the data reconstruction. Instead of using a large stencil of neighboring cells to perform a high-order reconstruction, the stencil is constructed by partitioning each grid cell, called a spectral volume (SV), into 'structured' sub-cells, called control volumes (CVs). One can show that if all the SV cells are partitioned into polygonal or polyhedral CV sub-cells in a geometrically similar manner, the reconstructions for all the SVs become universal, irrespective of their shapes, sizes, orientations, or locations. It follows that the reconstruction is reduced to a weighted sum of unknowns involving just a few simple adds and multiplies, and those weights are universal and can be pre-determined once for all. The method is thus very efficient, accurate, and yet geometrically flexible. The most critical part of the SV method is the partitioning of the SV into CVs. In this paper we present the partitioning of a tetrahedral SV into polyhedral CVs with one free parameter for polynomial reconstructions up to degree of precision five. (Note that the order of accuracy of the method is one order higher than the reconstruction degree of precision.) The free parameter will be determined by minimizing the Lebesgue constant of the reconstruction matrix or similar criteria to obtain optimized partitions. The details of an efficient, parallelizable code to solve three-dimensional problems for any order of accuracy are then presented. Important aspects of the data structure are discussed. Comparisons with the Discontinuous Galerkin (DG) method are made. Numerical examples for wave propagation problems are presented.

Liu, Yen↗

Electro-optic imaging Fourier transform spectrometer

An Electro-Optic Imaging Fourier Transform Spectrometer (EOIFTS) for Hyperspectral Imaging is described. The EOIFTS includes an input polarizer, an output polarizer, and a plurality of birefringent phase elements. The relative orientations of the polarizers and birefringent phase elements can be changed mechanically or via a controller, using ferroelectric liquid crystals, to substantially measure the spectral Fourier components of light propagating through the EIOFTS. When achromatic switches are used as an integral part of the birefringent phase elements, the EIOFTS becomes suitable for broadband applications, with over 1 micron infrared bandwidth.

Chao, Tien-Hsin↗

NASA Tech Briefs, November 2004

Topics include: Multifunction Imaging and Spectroscopic Instrument; Position-Finding Instrument Built Around a Magnetometer; Improved Measurement of Dispersion in an Optical Fiber; Probe for Sampling of Interstitial Fluid From Bone; Neuropsychological Testing of Astronauts; Method of Calibration for a Large Cathetometer System; Four-Channel PC/104 MIL-STD-1553 Circuit Board; Improved Method of Locating Defects in Wiring Insulation; Strobe Traffic Lights Warn of Approaching Emergency Vehicles; Improved Timing Scheme for Spaceborne Precipitation Radar; Concept for Multiple-Access Free-Space Laser Communications; Variable Shadow Screens for Imaging Optical Devices; Verifying Diagnostic Software; Initial Processing of Infrared Spectral Data; Activity-Centric Approach to Distributed Programming; Controlling Distributed Planning; New Material for Surface-Enhanced Raman Spectroscopy; Treated Carbon Nanofibers for Storing Energy in Aqueous KOH; Advanced Infant Car Seat Would Increase Highway Safety; Development of Biomorphic Flyers; Second-Generation Six-Limbed Experimental Robot; Miniature Linear Actuator for Small Spacecraft; Process for Making Single-Domain Magnetite Crystals; A New Process for Fabricating Random Silicon Nanotips; Resin-Transfer-Molding of a Tool Face; Improved Phase-Mask Fabrication of Fiber Bragg Gratings; Tool for Insertion of a Fiber-Optic Terminus in a Connector; Nanofluidic Size-Exclusion Chromatograph; Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs; Using Redundancy To Reduce Errors in Magnetometer Readings; Compact Instrument for Measuring Profile of a Light Beam; Multilayer Dielectric Transmissive Optical Phase Modulator; Second-Generation Multi-Angle Imaging Spectroradiometer; Real-Time Adaptive Color Segmentation by Neural Networks; Research and Development in Optical Communications; Tests of Multibeam Scintillation Mitigation on Laser Uplinks; and Spaceborne Infrared Atmospheric Sounder.

Source record↗

Portable Laser Spectrometer for Airborne and Ground-Based Remote Sensing of Geological CO2 Emissions

A 24 kilogram, suitcase-sized, CW (Continuous Wave) Laser Remote Sensing Spectrometer (LARSS) with an approximately 2-kilometer range has been developed. It has demonstrated its flexibility in measuring both atmospheric CO2 from an airborne platform and terrestrial emission of CO2 from a remote mud volcano, Bledug Kuwu, Indonesia, from a ground-based sight. This system scans the CO2 absorption line with 20 discrete wavelengths, as opposed to the typical two-wavelength online-offline instrument. This multi-wavelength approach offers an effective quality control, bias control, and confidence estimate of measured CO2 concentrations via spectral fitting. The simplicity, ruggedness, and flexibility in the design allow for easy transportation and use on different platforms with a quick setup in some of the most challenging climatic conditions. While more refinement is needed, the results represent a stepping stone towards widespread use of active one-sided gas remote sensing in the earth sciences.

_______________________↗

State-space solutions to standard H2 and H(infinity) control problems

Simple state-space formulas are derived for all controllers solving the standard H(infinity) problem of finding, for a given number gamma greater than 0, all controllers such that the H(infinity) norm of the closed-loop transfer function is (strictly) less than gamma. It is known that a controller exists if and only if the unique stabilizing solutions to two algebraic Riccati equations are positive definite and the spectral radius of their product is less than gamma squared. Under these conditions, a parameterization of all controllers solving the problem is given as a linear fractional transformation (LFT) on a contractive stable free parameter. The state dimension of the coefficient matrix for the LFT, constructed using the two Riccati solutions, equals that of the plant and has a separation structure reminiscent of classical LQG (i.e., H2) theory. A standard H2 solution is developed in parallel.

Doyle, John C.↗

Contributions of tidal lung inflation to human R-R interval and arterial pressure fluctuations

We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.

Clinical Trial↗

Method and circuit for controlling the evolution time interval of a laser output pulse

The invention is a method and circuit for controlling the evolution time interval of a laser output pulse used for making precise spectral measurements. It comprises the means for pumping a laser medium in a resonator that includes a Q-switch and polarizer that act in combination to control the loss in the resonator. A photodiode senses the resulting fluorescence which is applied to a two level Q-switch and polarizer from high to intermediate to substantially zero loss states to control the evolution time interval of the resulting laser output pulse.

Barnes, Norman P.↗

Low Cost Micro-Spectrometer for Resource Mapping on Mars

Scientific measurements within craters and along steep embankments on Mars pose extreme challenges since astronauts and rovers cannot access them. However, these areas offer the potential for thegreatest scientific return. NASA Langley Research Center (LaRC) has invented a deployable wireless micro-spectrometer [1-13] capable of accessing thosechallenging areas and, using telemetry, send measurements to a receiver safely outside those extreme environments. A prototype of the micro-spectrometer concept was fabricated and successfullytested for measurement of dopamine as a neural probe [14]. The bullet-sized micro-spectrometer concept can be designed for deployment by an astronaut, a rover, an aerial drone, or a lander, and the measurements broadcasted back to a receiver [13,15,16]. This device can also be installed on rovertires, under the astronaut’s boots, or a cane stick. The bullet-like consumable micro-spectrometer can penetrate soil to spectrally identify the components ofthe soil, such as water or minerals. The signals of the soil assay data are transmitted to a mother station through a telemetry system. The LaRC developed micro-spectrometer bullet consists of micro-spectrometer optics with an all imbedded burst-mode LED UV light source, a super-capacitor with control electronics, and telemetry electronics. Prototypes have been fabricated to demonstrate spectral assay of soil components. Further maturation of this technology would be necessary for demonstration on Mars. Future work includes a potential R&D program that includes other NASA Centers and industry partners interested in developing a business case that requires knowledge of the locations of extraterrestrial ice, for instance.

micro-spectrometer, mineral assay, resource mappin↗

Optically addressed asymmetric Fabry-Perot modulator

A low power, high contrast optically addressed modulator, operating with normal incidence, has been fabricated. Optically controlled reflection modulation is achieved through optically induced absorption modulation in a periodically delta-doped InGaAs/GaAs multiple quantum well structure inserted in an integrated asymmetric Fabry-Perot resonator. A contrast ratio over 60:1 was measured using a spectrally matched low power InGaAs/GaAs quantum well laser to generate the write (control) signal. The insertion loss for the normally off modulator is 4.6 dB at the highest write signal power (30 mW) used. The device lends itself to the fabrication of arrays for optically addressed spatial light modulation.

Larsson, A.↗

Land use/land cover mapping (1:25000) of Taiwan, Republic of China by automated multispectral interpretation of LANDSAT imagery

Three methods were tested for collection of the training sets needed to establish the spectral signatures of the land uses/land covers sought due to the difficulties of retrospective collection of representative ground control data. Computer preprocessing techniques applied to the digital images to improve the final classification results were geometric corrections, spectral band or image ratioing and statistical cleaning of the representative training sets. A minimal level of statistical verification was made based upon the comparisons between the airphoto estimates and the classification results. The verifications provided a further support to the selection of MSS band 5 and 7. It also indicated that the maximum likelihood ratioing technique can achieve more agreeable classification results with the airphoto estimates than the stepwise discriminant analysis.

Sung, Q. C.↗