Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building Energy Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Puerto Rico Solar-for-All: LMI PV Rooftop Technical Potential and Solar Savings Potential

The Puerto Rico Solar-For-All dataset provides Census Tract level estimates of residential low-to-moderate income (LMI) PV rooftop technical potential as well as solar electric bill savings potential for LMI communities at the municipality level. Each dataset is broken out by income group, defined by the Area Median Income (AMI), by tenure, and by building type. The underlying LiDAR data used the estimation were collected in 2015-2017 and the American Community Survey (ACS) data are from 2011-2015. This Puerto Rico Solar-For-All dataset is intended to extend the SEEDSII Solar-For-All estimates for the US 50-states ( https://www.nlr.gov/docs/fy18osti/70901.pdf ) for the territory of Puerto Rico using updated methods. Please see the data documentation for details.

14 SOLAR ENERGY↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

Evaluating Building Energy Code Compliance and Savings Potential through Large-Scale Simulation with Models Inferred by Field Data

Building energy code compliance is the crucial link between the actual energy savings and the efficiency prescribed in energy codes. A research project aiming to identify opportunities to reduce energy consumption in new single-family residential construction by increasing compliance with the building energy code was conducted in several states of the United States. The study was comprised of three phases: (1) a baseline study to document typical practice and identify opportunities for improvement based on empirical data gathered from the field; (2) an education and training phase targeting the opportunities identified; and (3) a post-study to assess whether a reduction in average state-wide energy use could be achieved following the education and training phase. We proposed a novel methodology based on large-scale building energy simulation inferred by limited field data to assess the performance of a large population of homes. This paper presents the methodology, findings, and results of this study. The state-wide average energy consumption decreased at Phase III from Phase I for five of the seven states involved in the analysis. The measure-level savings potential analysis shows an overall reduction. Overall, the training and education phase plays a recognizable role in improving compliance with building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Development and validation of a second-order thermal network model for residential buildings

Heating, Ventilation, and Air Conditioning (HVAC) systems can maintain the space air temperature of residential buildings, either directly by heating/cooling the air, or indirectly via heat transfer to and from the building structure that acts as a thermal mass. Hence, HVAC systems can help achieve load shifting, peak load reduction, and/or energy cost saving, thus enabling grid-interactive HVAC operation. A home thermal model that can accurately reflect the dynamics of the space air and interior wall surface temperatures, is therefore valuable. This paper develops such a model using the standard RC (resistance-capacitance) approach. The model contains a virtual envelope node and an internal space node and is thus second-order. A hybrid parameter identification scheme, made up of the least-squares and optimal search methods, is also developed. The proposed model and scheme were validated using data collected from a test home. It was found that a modest amount of training data was sufficient to yield reliable parameter estimates and accurate prediction. It was also found that when making 24-hour-ahead prediction of the space air temperature, both methods had comparable performances when the training data began in a transition season. However, when they began in an HVAC season, the optimal search method performed better. Furthermore, the least-squares method is recommended during a transition season due to its lower computational burden, while the optimal search method is recommended during an HVAC season due to its better estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Field Test Best Practices

This report can be used as a resource for advice on every stage of field research in residential buildings. It can be used as a reference document to find descriptions of specific types of common measurements and tricks of the trade, or as a primer on home field research providing a basic education on the subject. The report begins with descriptions of field experiment design and discusses advantages and disadvantages of different types of data acquisition systems. The bulk of the paper describes the common measurements needed in residential field work, the hardware options for making the measurements, and field notes on with tips, tricks, and cautions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Equivalent Battery Model Representations for Thermostatically Controlled Loads in Commercial Buildings

Models for thermostatically controlled loads in commercial buildings often include many parameters and variables compared to residential buildings. As such, it is beneficial to use reduced-order models to represent these resources. A classic example of such a model is the Virtual Battery or Equivalent Battery Model (EBM). In this paper, the typical EBM is extended to higher-order commercial Heating, Ventilation, and Air-conditioning (HVAC) models and adapted for electric water heaters. Finally, we compare the performance of EBMs with detailed thermal models using three classic optimization problems - energy maximization, energy minimization, and power reference tracking. Our results show that the EBM-constrained and detailed thermal model-constrained problems produce similar outcomes in terms of temperature, power, and total energy consumption.

commercial buildings↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Deep Reinforcement Learning for Autonomous Water Heater Control

Electric water heaters represent 14% of the electricity consumption in residential buildings. An average household in the United States (U.S.) spends about USD 400–600 (0.45 ¢/L–0.68 ¢/L) on water heating every year. In this context, water heaters are often considered as a valuable asset for Demand Response (DR) and building energy management system (BEMS) applications. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity cost of a water heater under a time-of-use (TOU) electricity pricing policy by only using standard DR commands. In this approach, a set of RL agents, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on an unseen pair of price and hot water usage profiles. The testing results showed that the RL agents can help save electricity cost in the range of 19% to 35% compared to the baseline operation without causing any discomfort to end users. Additionally, the RL agents outperformed rule-based and model predictive control (MPC)-based controllers and achieved comparable performance to optimization-based control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Layered Thermal Insulation Systems for Industrial and Commercial Applications

From the high performance arena of cryogenic equipment, several different layered thermal insulation systems have been developed for industrial and commercial applications. In addition to the proven areas in cold-work applications for piping and tanks, the new Layered Composite Insulation for Extreme Environments (LCX) has potential for broader industrial use as well as for commercial applications. The LCX technology provides a unique combination of thermal, mechanical, and weathering performance capability that is both cost-effective and enabling. Industry applications may include, for example, liquid nitrogen (LN2) systems for food processing, liquefied natural gas (LNG) systems for transportation or power, and chilled water cooling facilities. Example commercial applications may include commercial residential building construction, hot water piping, HVAC systems, refrigerated trucks, cold chain shipping containers, and a various consumer products. The LCX system is highly tailorable to the end-use application and can be pre-fabricated or field assembled as needed. Product forms of LCX include rigid sheets, semi-flexible sheets, cylindrical clam-shells, removable covers, or flexible strips for wrapping. With increasing system control and reliability requirements as well as demands for higher energy efficiencies, thermal insulation in harsh environments is a growing challenge. The LCX technology grew out of solving problems in the insulation of mechanically complex cryogenic systems that must operate in outdoor, humid conditions. Insulation for cold work includes equipment for everything from liquid helium to chilled water. And in the middle are systems for LNG, LN2, liquid oxygen (LO2), liquid hydrogen (LH2) that must operate in the ambient environment. Different LCX systems have been demonstrated for sub-ambient conditions but are capable of moderately high temperature applications as well.

thermal conductivity↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2021 Thermal Energy Storage Systems for Buildings Workshop: Priorities and Pathways to Widespread Deployment of Thermal Energy Storage in Buildings

The 2021 U.S. Department of Energy's (DOE) "Thermal Energy Storage Systems for Buildings Workshop: Priorities and Pathways to Widespread Deployment of Thermal Energy Storage in Buildings" was hosted virtually on May 11 and 12, 2021. This report provides an overview of the workshop proceedings. Organized by DOE's Building Technologies Office (BTO), the National Renewable Energy Laboratory, Lawrence Berkeley National Laboratory, and Oak Ridge National Laboratory, the workshop convened more than 600 stakeholders from around the world to discuss the need for advancing the deployment of thermal energy storage (TES) in buildings. This workshop was designed to build on BTO's webinar series and 2019 workshop. The goals of this workshop were to promote discussion on TES related to: 1. Market adoption and deployment barriers, 2. Key applications and value drivers, 3. System cost, performance, and market requirements, and 4. End-use specific needs. The workshop took place over two days and consisted of keynote presentations, moderated panels, breakout sessions, and open discussion forums. The keynote presentations introduced opportunities for building TES, barriers to widespread deployment, and future visions. Moderated panel discussions presented diverse perspectives, breakout sessions provided opportunities for more intimate conversations, and open discussions captured feedback from the entire workshop group. Over the course of the two days, attendees exchanged experiences and ideas surrounding multiple aspects of TES in buildings. The first section of this report provides background on the motivations behind advancing TES for residential and commercial buildings and elaborates on the workshop objectives. The second section details the workshop structure and participant demographics. The third section provides key findings of the discussions that took place during the breakout sessions. Finally, this report details recommendations and actions to increase the TES deployment. Several recommendations from workshop attendees are presented in Table ES-1. TES holds significant potential to help increase building efficiency, grid-interactivity, and energy resilience, as well as reduce associated carbon emissions. The outputs generated from this workshop will aid stakeholders in advancing TES in buildings through a deeper understanding of the opportunities and barriers surrounding widespread deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP↗

Pathways for decarbonization of the buildings sector in Ukraine

The paper focuses on Ukraine’s intention to achieve a two-thirds reduction in buildings’ energy consumption for heating and cooling by 2050, concurrently aiming for net zero greenhouse gas emissions and heightened energy security. Here, the study examines the outcomes of retrofitting existing residential, commercial, and public buildings with highly efficient materials, improving construction standards, and transitioning to advanced heating systems. However, Russia’s invasion in 2022 inflicted substantial damage, prompting a shift from retrofit and decarbonization to reconstruction. The Ukrainian government’s Reconstruction Plan emphasizes clean, sustainable, and resilient energy systems. The study employs energy system and integrated assessment models (TIMES-Ukraine and GCAM-Ukraine) to explore scenarios taking into consideration the war, reconstruction, and a net zero CO 2 pathway. Using two models allowed the inter-model comparison. The analysis addresses vital questions on energy resiliency measures and the compounding effects of decarbonization. Findings indicate that Ukraine’s energy goals can be met through strategic retrofitting and economy-wide decarbonization, emphasizing the importance of low-carbon alternatives like district heating with renewable sources. Electrification with renewables and fuel-switching emerges as crucial for achieving building decarbonization. The study offers valuable insights into navigating energy challenges amidst the war and outlines a pathway for Ukraine’s sustainable energy future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the Performance, Application, and Cost of Retrofit Wall Systems for Residential Buildings

The Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and the University of Minnesota have been conducting a three-year study of residential retrofit wall systems. The researchers have identified, tested, and verified the hygrothermal performance of 16 wall assemblies in retrofit applications. The approach to this study includes a comprehensive literature review, the involvement of an advisory group of thermal enclosure experts, smallscale experimental in situ testing of the wall assemblies at the University of Minnesota’s Cloquet Residential Research Facility, and energy and hygrothermal simulation of wall assemblies using EnergyPlus, THERM, and WUFI. Simulation and experimental results are then combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits.This presentation summarizes the findings of this research project and is intended to guide architects and designers on how to retrofit existing wall assemblies without creating durability issues.

Desjarlais, Andre Omer↗

Electrical Switching of Nematic Plasmonic Nanocolloids for Infrared Solar Gain Control

Controlling solar gain is essential to reduce the energy consumption by residential and commercial buildings, which are responsible for ≈40% of all energy generated globally. However, the dynamic control of solar gain in the near-infrared that corresponds to ≈50% of the overall Sun's energy at the Earth's surface, separately from the visible spectral range has been a challenge, albeit commercial coatings provide passive control while retaining highly visible transmission. To address this problem, in this paper switchable silver colloids (SSCs) are demonstrated, colloidal analogs of the common silver coatings used for solar gain control. When dispersed in a nematic liquid crystal, orientations of such plasmonic silver nanoplates are controlled by ≈1 V low-voltage electric fields, allowing for sub-second switching of the near-infrared-based solar gain. Installed and retrofit products made from thin films of such nanoplate dispersions confined between glass and plastic substrates, respectively, exhibit electrically controlled infrared-based solar gain while retaining high visible-range transparency, low haze, and high color rendering index. Furthermore, this study's findings reveal a great potential of soft-matter systems in addressing energy-related problems.

36 MATERIALS SCIENCE↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗