Characterizing W sources in the all-W wall, all-RF WEST tokamak environment

In this work, experimental data, together with interpretive modeling tools, are examined to study trends in the tungsten (W) source in the all-W environment of the WEST tokamak, both from the divertor and from the main chamber. In particular, a poloidal limiter protecting an ion cyclotron resonance heating (ICRH) antenna is used as proxy for main chamber sourcing. The key study is carried out by stepping up lower hybrid current drive (LHCD) power, as the only auxiliary power source. Limiter and divertor W sources exhibit a qualitatively similar proportionality to the total power crossing the separatrix, P SEP , although the main chamber source remains substantially lower than the divertor source, for the range of P SEP accessible in the experiments. Intepretive modeling of the limiter source is carried out with a particle-in-cell (PIC) sheath model coupled to a surface sputtering model. Oxygen is used as a proxy for all light impurity species allowing for characterization of the critical W erosion regions. To get a good quantitative match to the data, it is necessary to assume that the oxygen arrives at the surface mostly at high ionization stages (4+ and above). A separate simulation with SOLEDGE-EIRENE, constrained to measured upstream scrape-off-layer plasma profiles, gives oxygen fractional abundances that are compatible with the PIC simulation result. This is understood to arise from transport processes that dominate over recombination. Substituting the LHCD by ICRH, in an equivalent experiment, the local W source exhibits a 3× enhancement. This can be matched by the simulation, by assuming local RF electric field rectification, based on ~100 eV peak-to-peak, near-antennna electric field. This work has highlighted the particular importance of understanding the ion charge state balance of light impurities as these are most likely the dominant sputtering species in fusion devices with high-Z walls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developments in Fullerene Ion Propulsion Research

Several reports of successful operation of DC discharges using fullerene vapor have been made. However, degradation of the propellant molecules in the vapor source and in contact with the filament cathode was observed in each case. Because disintegration of the fullerene cage could result in poor performance or thruster failure, we have developed an RF ion thruster for use with C 60 propellant to avoid the presence of electrodes inside the discharge chamber. Also, we conducted a series of experiments to ascertain the stability of fullerenes at high temperatures. We find that when C 60 and C 70 are maintained at temperatures above 1073 K, or are exposed to hot metal surfaces, significant degradation occurs. We find an activation energy of 261.5 kJ/mol for this process. At temperatures below 873 K, no breakdown of fullerenes can be detected, even after heating for 6 hours. The effect of these findings on C 60 ion thruster design is discussed.

fullerenes↗

Surface plasma source with saddle antenna radio frequency plasma generator

A prototype RF H{sup -} surface plasma source (SPS) with saddle (SA) RF antenna is developed which will provide better power efficiency for high pulsed and average current, higher brightness with longer lifetime and higher reliability. Several versions of new plasma generators with small AlN discharge chambers and different antennas and magnetic field configurations were tested in the plasma source test stand. A prototype SA SPS was installed in the Spallation Neutron Source (SNS) ion source test stand with a larger, normal-sized SNS AlN chamber that achieved unanalyzed peak currents of up to 67 mA with an apparent efficiency up to 1.6 mA/kW. Control experiments with H{sup -} beam produced by SNS SPS with internal and external antennas were conducted. A new version of the RF triggering plasma gun has been designed. A saddle antenna SPS with water cooling is fabricated for high duty factor testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Cold and Hot Electron Populations, Temperatures and Their Transports in the Edge Plasma of the ORNL CAPRICE ECR Ion Source

The edge plasma of the ORNL CAPRICE ECR ion source is studied by directly measuring, with electrical probes, its local plasma parameters such as plasma density, temperature and electron energy distribution characteristics at different rf power levels, at various pressures, at various axial magnetic field strengths and different distances from the resonant zone. It is found that the edge plasma can be approximated to be bi-Maxwellian, whose characteristics become more pronounced at the more distant positions from the ECR zone, at lower source pressures and at increased magnetic field strengths. These trends are consistently explained in terms of long-range electron-electron and electron-ion Coulomb scattering collisions that occur during the transport of hot electrons from the ECR plasma to the probe and their frequency dependence on electron temperature and density.

43 PARTICLE ACCELERATORS↗

Spin Resonance Strength Calculations

In calculating the strengths of depolarizing resonances it may be convenient to reformulate the equations of spin motion in a coordinate system based on the actual trajectory of the particle, as introduced by Kondratenko, rather than the conventional one based on a reference orbit. It is shown that resonance strengths calculated by the conventional and the revised formalisms are identical. Resonances induced by radiofrequency dipoles or solenoids are also treated; with rf dipoles it is essential to consider not only the direct effect of the dipole but also the contribution from oscillations induced by it.

43 PARTICLE ACCELERATORS↗

Plasma production and ion heating systems for the Material Plasma Exposure eXperiment

Plasma production and ion heating in the Material Plasma Exposure eXperiment (MPEX), whose design is nearing completion, is accomplished using continuous wave RF power with average power density up to 1.6 MW/m2 at the plasma interface. Plasma is produced using helicon waves coupled through a single helical antenna at 13.56 MHz with power supplied by three 100 kW fixed-frequency RF generators feeding a power combiner network followed by the matching network and launcher. The helicon source can utilize various gasses including hydrogen, deuterium, and helium, with a magnetic field strength in the source region up to 0.2 T, and maximum device |B| of 2.5 T. Power is coupled to ions via ion cyclotron heating at the fundamental resonance using a pair of phased helical antennas operating in the frequency range 4-9 MHz, that launch waves towards the resonance from the antenna region where ω > ωci. ICH power is supplied by a single 500 kW tunable RF transmitter through a 90° power splitter and matching/decoupling network. In the case of both the helicon and ICH systems the antennas are located external to the vacuum, with power transferred through novel water-cooled coaxial vacuum windows consisting of fused quartz outer cylinders and silicon nitride inner cylinders with forced convection water cooling between them. The antenna enclosures are pressurized with dry air to 3 bar absolute for voltage standoff.Several 3-D COMSOL models have been created to simulate the two systems. A model of the helicon region utilizing a cold plasma dielectric tensor with accurate magnetic field and realistic plasma density profiles has been used to calculate the plasma loading/complex antenna input impedance at the launcher feed for various ne and |B| values, for the purpose of estimating power handling. It also incorporates the geometry of all launcher structures relevant to this determination. A still more detailed model of the launcher together with a lossy dielectric plasma surrogate has been used to determine RF electric field values and power losses in the device components.Similar models have been produced to predict the performance and power handling of the ICH launcher. For this device the impedance matrix of the two-element antenna array is calculated using a warm plasma model, necessary to properly determine the wave propagation and absorption.

Goulding, Richard↗

On the merit of hot ion mode for tearing mode stabilization

The stabilization of tearing modes with rf driven current benefits from the cooperative feedback loop between rf power deposition and electron temperature within the island. This effect, termed rf current condensation, can greatly enhance and localize the current driven within magnetic islands. It has previously been shown that the condensation effect opens the possibility of passive stabilization with broad rf profiles, as would be typical of LHCD for steady state operation. Here, we show that this self-healing effect can be dramatically amplified by operation in a hot ion mode, due to the additional electron heat source provided by the hotter ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma ion dynamics and beam formation in electron cyclotron resonance ion sources

In electron cyclotron resonance ion sources it has been demonstrated that plasma heating may be improved by means of different microwave to plasma coupling mechanisms, including the ''frequency tuning'' and the ''two frequency heating''. These techniques affect evidently the electron dynamics, but the relationship with the ion dynamics has not been investigated in details up to now. Here we will try to outline these relations: through the study of ion dynamics we may try to understand how to optimize the electron cyclotron resonance ion sources brightness. A simple model of the ion confinement and beam formation will be presented, based on particle-in-cell and single particle simulations.

43 PARTICLE ACCELERATORS↗

The K{sub a}-band 10-kW continuous wave gyrotron with wide-band fast frequency sweep

The dual-frequency gyrotron with fast 2% frequency sweep at about 28 GHz is designed to power an electron cyclotron resonance ion source (ECRIS). Operation with an output power of up to 10 kW in CW mode and efficiency of 20% was demonstrated at both frequencies. Frequency manipulation has a characteristic time of about 1 ms and is based on magnetic field variation with an additional low-power coil. Fast frequency sweep will supposedly increase the ion current and the average ion charge of ECRIS. The possibility of 100% power modulation is demonstrated using the same control method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wall charging of a helicon antenna wrapped plasma filled dielectric tube

Dielectric wall charging of a cylindrical glass wall surrounded by a helicon antenna of 18 cm length is measured in a linear helicon plasma device with a diverging magnetic field. The ions because of their lesser mobility do not respond to the high frequency electric field and the electrons charge the wall to a negative DC potential also known as the DC self-bias. The wall potential in this device is characterized for different neutral pressure, magnetic field, and radio frequency (RF) power. Axial variation of wall potential shows higher self-bias potentials near the antenna rings. Ion magnetization in the source chamber increases both wall charging and plasma potential of the source due to confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active cleaning technique device

The objective of this program was to develop a laboratory demonstration model of an active cleaning technique (ACT) device. The principle of this device is based primarily on the technique for removing contaminants from optical surfaces. This active cleaning technique involves exposing contaminated surfaces to a plasma containing atomic oxygen or combinations of other reactive gases. The ACT device laboratory demonstration model incorporates, in addition to plasma cleaning, the means to operate the device as an ion source for sputtering experiments. The overall ACT device includes a plasma generation tube, an ion accelerator, a gas supply system, a RF power supply and a high voltage dc power supply.

Shannon, R. L.↗

Laser ion source for heavy ion inertial fusion

The proposed heavy ion inertial fusion (HIF) scenarios require ampere class low charge state ion beams of heavy species. A laser ion source (LIS) is recognized as one of the promising candidates of ion beam providers, since it can deliver high brightness heavy ion beams to accelerators. A design of LIS for the HIF depends on the accelerator structure and accelerator complex following the source. In this article, we discuss the specifications and design of an appropriate LIS assuming two major types of the accelerators: radio frequency (RF) high quality factor cavity type and non-resonant induction core type. We believe that a properly designed LIS satisfies the requirements of both types, however some issues need to be verified experimentally.

43 PARTICLE ACCELERATORS↗

Recent progress on the superconducting ion source VENUS

The 28 GHz Ion Source VENUS (versatile ECR for nuclear science) is back in operation after the superconducting sextupole leads were repaired and a fourth cryocooler was added. VENUS serves as an R and D device to explore the limits of electron cyclotron resonance source performance at 28 GHz with its 10 kW gryotron and optimum magnetic fields and as an ion source to increase the capabilities of the 88-Inch Cyclotron both for nuclear physics research and applications. The development and testing of ovens and sputtering techniques cover a wide range of applications. Recent experiments on bismuth demonstrated stable operation at 300 e{mu}A of Bi{sup 31+}, which is in the intensity range of interest for high performance heavy-ion drivers such as FRIB (Facility for Rare Isotope Beams). In addition, the space radiation effects testing program at the cyclotron relies on the production of a cocktail beam with many species produced simultaneously in the ion source and this can be done with a combination of gases, sputter probes, and an oven. These capabilities are being developed with VENUS by adding a low temperature oven, sputter probes, as well as studying the RF coupling into the source.

43 PARTICLE ACCELERATORS↗

Beam formation in the alternative JLEIC ion complex

The proposed alternative design approach for the JLab-EIC (JLEIC) ion complex uses a more compact linac and pre-booster, and consolidates the electron storage ring (ering) as a large booster for the ions. Following a parameter study showing the feasibility of this design approach, we have adapted the e-ring lattice by adding RF sections to accelerate ion beams. In this study, we focus on the transverse beam formation for protons and lead ions from the ion source to collision point including the linac, pre-booster, e-ring and collider ring. Effects such as stripping injection, space charge, intra-beam scattering and beam cooling determine the total charge accumulated in each ring and the final luminosity of the collider.

Mustapha, Brahim↗

Tunable Microwave Cavity For Ion Source

Movable probe and tuning wall adjusted to obtain resonance at microwave frequency used to generate plasma in cell at one end of microwave cavity. Electroless discharge without disadvantages of dc-cathode-discharge and RF-induction methods. To achieve precise positioning, coaxial probe extends into microwave cavity through tube.

Nakanishi, Shigeo↗

An adaptable multiple power source for mass spectrometry and other scientific instruments

Power supplies are commonly used in the operation of many types of scientific equipment, including mass spectrometers and ancillary instrumentation. A generic modern mass spectrometer comprises an ionization source, such as electrospray ionization (ESI), ion transfer devices such as ion funnels and multipole ion guides, and ion signal detection apparatus. Very often such platforms include, or are interfaced with ancillary elements in order to manipulate samples before or after ionization. In order to operate such scientific instruments, numerous direct current (DC) channels and radio frequency (RF) signals are required, along with other controls such as temperature regulation. In particular, DC voltages in the range of ±400 V, along with MHz range RF signals with peak-to-peak amplitudes in the hundreds of volts range are commonly used to transfer ionized samples under vacuum. Additionally, an ESI source requires a high voltage (HV) DC source capable of producing several thousand volts and heaters capable of generating temperatures up to 300°C. All of these signals must be properly synchronized and managed in order to carry out ion trapping, accumulation and detection.

47 OTHER INSTRUMENTATION↗

Improved efficiency and precise temperature control of low-frequency induction-heating pure iron vapor source on ECR ion source

Multiply charged ions to be used prospectively are produced from solid pure material in an electron cyclotron resonance ion source (ECRIS). Recently a pure iron source is also required for the production of caged iron ions in the fullerene in order to control cells in vivo in bio-nano science and technology. We adopt directly heating iron rod by induction heating (IH) because it has non-contact with insulated materials which are impurity gas sources. We choose molybdenum wire for the IH coils because it doesn't need water cooling. To improve power efficiency and temperature control, we propose to the new circuit without previously using the serial and parallel dummy coils (SPD) for matching and safety. We made the circuit consisted of inductively coupled coils which are thin-flat and helix shape, and which insulates the IH power source from the evaporator. This coupling coils circuit, i.e. insulated induction heating coil transformer (IHCT), can be move mechanically. The secondary current can be adjusted precisely and continuously. Heating efficiency by using the IHCT is much higher than those of previous experiments by using the SPD, because leakage flux is decreased and matching is improved simultaneously. We are able to adjust the temperature in heating the vapor source around melting point. And then the vapor pressure can be controlled precisely by using the IHCT. We can control {+-}10K around 1500 Degree-Sign C by this method, and also recognize to controlling iron vapor flux experimentally in the extreme low pressures. Now we come into next stage of developing induction heating vapor source for materials with furthermore high temperature melting points above 2000K with the IHCT, and then apply it in our ECRIS.

74 ATOMIC AND MOLECULAR PHYSICS↗

Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source

A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.