Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOAD DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Evaluating Domestic Hot Water Distribution System Options With Validated Analysis Models

A developing body of work is forming that collects data on domestic hot water consumption, water use behaviors, and energy efficiency of various distribution systems. A full distribution system developed in TRNSYS has been validated using field monitoring data and then exercised in a number of climates to understand climate impact on performance. This study builds upon previous analysis modelling work to evaluate differing distribution systems and the sensitivities of water heating energy and water use efficiency to variations of climate, load, distribution type, insulation and compact plumbing practices. Overall 124 different TRNSYS models were simulated. Of the configurations evaluated, distribution losses account for 13-29% of the total water heating energy use and water use efficiency ranges from 11-22%. The base case, an uninsulated trunk and branch system sees the most improvement in energy consumption by insulating and locating the water heater central to all fixtures. Demand recirculation systems are not projected to provide significant energy savings and in some cases increase energy consumption. Water use is most efficient with demand recirculation systems, followed by the insulated trunk and branch system with a central water heater. Compact plumbing practices and insulation have the most impact on energy consumption (2-6% for insulation and 3-4% per 10 gallons of enclosed volume reduced). The results of this work are useful in informing future development of water heating best practices guides as well as more accurate (and simulation time efficient) distribution models for annual whole house simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Domestic Hot Water Distribution System Options with Validated Analysis Models

A developing body of work is forming that collects data on domestic hot water consumption, water use behaviors, and energy efficiency of various distribution systems. Transient System Simulation Tool (TRNSYS) is a full distribution system developed that has been validated using field monitoring data and then exercised in a number of climates to understand climate impact on performance. In this study, the Building America team built upon previous analysis modeling work to evaluate differing distribution systems and the sensitivities of water heating energy and water use efficiency to variations of climate, load, distribution type, insulation and compact plumbing practices. Overall, 124 different TRNSYS models were simulated. The results of this work are useful in informing future development of water heating best practices guides as well as more accurate (and simulation time efficient) distribution models for annual whole house simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of advanced reduced-basis methods for transient structural analysis

Two advanced reduced-basis methods for linear, transient structural analysis, the force-derivative method and the Lanczos method, are compared to two widely-used modal methods, the mode-displacement method and the mode-acceleration method. Comparisons are made for two linear example problems: a proportionally-damped cantilevered beam subject to a discrete tip load which varies linearly with time, and a discretely-damped multispan beam subject to a uniformly distributed load which varies as a quintic function of time. Results from the methods are compared in terms of the number of basis vectors required to obtain a desired level of accuracy and the associated computational times. The results are problem dependent, and it is shown that for the cantilevered beam problem, the mode-acceleration and force-derivative methods are the most efficient in terms of the number of basis vectors and computational time. The force-derivative method is shown to be the most effective method for solving the multispan beam problem with closely-spaced frequencies. In general, the force-derivative method is shown to produce an accurate solution using very few basis vectors and to require less computational time as compared to the other methods studied.

Mcgowan, David M.↗

Divertor configuration and heat load studies for the ARIES-CS fusion power plant

The critical issue of divertor configuration for heat and particle flux control in a conceptual ARIES compact stellarator (CS) reactor is addressed. The goal is to determine a divertor location and geometry with a peak heat load of not more than 10 MW/m(2) for a CS equilibrium based on the configuration to be used in the NCSX experiment, optimized for high beta (6.4%) and designed for low alpha-particle power loss fraction (<= 5%). The surface heat flux on the target has three components: thermal particles, lost energetic alphas, and radiation from the core and the scrape-off layer. The first two components are dominant and their magnitudes can be comparable. To maintain a tritium-breeding ratio of 1.1, the total target area should not exceed 15% of the boundary plasma surface area. The divertor concept consists of two pairs of target plates per field period, one pair each at the top and bottom of the plasma. The heat flux profile is assessed by assuming that the parallel transport can be represented by field line mapping and that cross-field transport can be modeled with a prescribed field line diffusion scheme. In this manner, the poloidal and toroidal extents of the plates and their shape and distance to the plasma are designed to intercept all the heat flux and to minimize the peak thermal heat load. An approximate scheme, based on particle drift orbits in the core and field line tracing in the edge, is derived to estimate the alpha-particle heat load distribution over the plates and the first wall. The best plate configuration to date yields total peak heat loads (thermal + alpha) ranging from 5 to 18 MW/m(2). Further optimization of the target plates is required to reach the design goal, which will be addressed in a future study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The stresses in columns under combined axial and side loads

The problem before us is to determine the total stresses in an axially loaded column of any degree of restraint which is also subject to transverse bending both from a uniformly distributed load and from concentrated loads.

COLUMNS - STRESSES↗

Understanding Customer Dissatisfaction with Underutilized Distributed File Servers

An important trend in the design of storage subsystems is a move toward direct network attachment. Network-attached storage offers the opportunity to off-load distributed file system functionality from dedicated file server machines and execute many requests directly at the storage devices. For this strategy to lead to better performance, as perceived by users, the response time of distributed operations must improve. In this paper we analyze measurements of an Andrew file system (AFS) server that we recently upgraded in an effort to improve client performance in our laboratory. While the original server's overall utilization was only about 3%, we show how burst loads were sufficiently intense to lead to period of poor response time significant enough to trigger customer dissatisfaction. In particular, we show how, after adjusting for network load and traffic to non-project servers, 50% of the variation in client response time was explained by variation in server central processing unit (CPU) use. That is, clients saw long response times in large part because the server was often over-utilized when it was used at all. Using these measures, we see that off-loading file server work in a network-attached storage architecture has to potential to benefit user response time. Computational power in such a system scales directly with storage capacity, so the slowdown during burst period should be reduced.

Riedel, Erik↗

Critical impact of experimentally-driven strut level anisotropic material models in advanced stress analysis of additively manufactured lattice structures

The rapid acceleration in materials discovery may overshadow the importance of thoroughly understanding the mechanical performance of newly developed materials in demanding environments. The recent interest in combining parametric studies with machine learning techniques to explore how changes in specific processing parameters or model inputs affect the overall behavior of a material system can only be truly beneficial if the governing constitutive relations describing material behavior are accurately established. In this study, we demonstrate the critical impact of accurately representing strut-level anisotropic material behavior in advanced stress analysis of additively manufactured lattice structures (AMLS). We introduce a systematic experimental and modeling approach for developing strut-level anisotropic elastoplastic material models that account for the influence of microstructural features such as porosity, texture, and surface roughness on the development of local anisotropic mechanical properties, which vary with strut orientation relative to the build direction (BD). As a result the presented material model captures and relates the statistics of spatially varying struts’ microstructural features to the local stress distribution. Our findings suggest that incorporating strut-level anisotropic material behavior into unit cell analysis significantly influences the load distribution and evolution of local stresses within the structure. Therefore, accounting for this anisotropy is critical for developing an understanding of unit cell behavior and performance, including subsequent topology/component design optimization based on this analysis.

Sahoo, Subhadip [University of Arizona]↗

Modeling Framework and Validation of a Smart Grid and Demand Response System for Wind Power Integration

Electricity generation from wind power and other renewable energy sources is increasing, and their variability introduces new challenges to the power system. The emergence of smart grid technologies in recent years has seen a paradigm shift in redefining the electrical system of the future, in which controlled response of the demand side is used to balance fluctuations and intermittencies from the generation side. This paper presents a modeling framework for an integrated electricity system where loads become an additional resource. The agent-based model represents a smart grid power system integrating generators, transmission, distribution, loads and market. The model incorporates generator and load controllers, allowing suppliers and demanders to bid into a Real-Time Pricing (RTP) electricity market. The modeling framework is applied to represent a physical demonstration project conducted on the Olympic Peninsula, Washington, USA, and validation simulations are performed using actual dynamic data. Wind power is then introduced into the power generation mix illustrating the potential of demand response to mitigate the impact of wind power variability, primarily through thermostatically controlled loads. The results also indicate that effective implementation of Demand Response (DR) to assist integration of variable renewable energy resources requires a diversity of loads to ensure functionality of the overall system.

Demand Response↗

Flight inspection data and crack initiation times

Lockheed C-130 service-flight inspection data is reduced by means of fracture mechanics and statistical analysis into a form from which the probability of time to crack initiation and the distribution of initial flaw sizes for various locations on the aircraft can be determined. Crack sizes are normalized by extrapolating a growing crack backwards from its first recorded size to .03 inches (crack initiation size) yielding the time to crack initiation. In a similar fashion, the crack is grown backwards to a time equal to zero to yield an initial flaw size. In order to perform the discussed computations, crack growth constants were computed for each individual location and were analyzed statistically. Statistical distributions were fitted to times to crack initiation and to initial flaw sizes in order to describe their expected behavior. Weibull and Johnson distributions have been found to fit the data reasonably well but for a better fit convolution integrals of Poisson load distributions and Weibull strength distributions are needed.

Johnson, W. S.↗

Large Load Impacts to Distribution System Hosting Capacity

This work examined the impact of large loads on utility distribution system models using the Sandia-developed open-source software DREAMS. It was shown that hosting capacity varies with location and changes after any asset is added to, or removed from, a system. Despite the tested models having similar rated voltages and other characteristics, their thermal and voltage constrained hosting capacity varied over 2 MW. The addition of a 3-phase balanced constant power large load with power factor of 1.0 exhibited non-linear reductions to all voltage constrained hosting capacities. The reductions to thermal constrained hosting capacity from a load with similar characteristics was more linear, related to the size of the added load, and did not impact all model buses. Co-located capacitors were shown to accommodate demand that was beyond the baseline voltage constrained hosting capacity limits, however, the costs and benefits from this approach were found to not be 1:1 and required additional available thermal capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical investigation of plasma edge transport and limiter heat fluxes in Wendelstein 7-X startup plasmas with EMC3-EIRENE

Here the results of a first systematic assessment of plasma edge transport processes for the limiter startup configuration at Wendelstein 7-X are presented. This includes an investigation of transport from intrinsic and externally injected impurities and their impact on the power balance and limiter heat fluxes. The fully 3D coupled plasma fluid and kinetic neutral transport Monte Carlo code EMC3-EIRENE is used. The analysis of the magnetic topology shows that the poloidally and toroidally localized limiters cause a 3D helical scrape-off layer (SOL) consisting of magnetic flux tubes of three different connection lengths L C . The transport in the helical SOL is governed by L C as topological scale length for the parallel plasma loss channel to the limiters. A clear modulation of the plasma pressure with L C is seen. The helical flux tube topology results in counter streaming sonic plasma flows. The heterogeneous SOL plasma structure yields an uneven limiter heat load distribution with localized peaking. Assuming spatially constant anomalous transport coefficients, increasing plasma density yields a reduction of the maximum peak heat loads from 12 MWm -2 to 7.5 MWm -2 and a broadening of the deposited heat fluxes. The impact of impurities on the limiter heat loads is studied by assuming intrinsic carbon impurities eroded from the limiter surfaces with a gross chemical sputtering yield of 2 . The resulting radiative losses account for less than 10% of the input power in the power balance with marginal impact on the limiter heat loads. It is shown that a significant mitigation of peak heat loads, 40–50%, can be achieved with controlled impurity seeding with nitrogen and neon, which is a method of particular interest for the later island divertor phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sea, ice and surface water circulation, Alaskan continental shelf

The author has identified the following significant results. ERTS-1 imagery has been extremely useful in understanding the tidal water movements in a large estuary such as Cook Inlet. As more imagery obtained during various tidal stages become available it appears that complex and fast changing micro-circulation patterns develop in various regions of Cook Inlet during each advancing and receding tide. More ERTS-1 synoptic imagery is needed to fully understand the effect of the approach of tidal front on the water movements in the various regions through the estuary. The conventional onboard ship data gathered during various cruises although revealed the overall circulation pattern in Cook Inlet but failed to show micro-subgyres which develop in various regions during each tide which are discernible on ther ERTS-1 imagery. Suspended load distribution in the Bering Sea during summer varies significantly. In areas of phytoplankton bloom and at the river mouths the suspended load is higher than the 1 mg/1 which is found over most areas. The influence of major rivers on temperature, salinity, and suspended load in surface water as well as at shallow depth is apparent. On the Bering shelf a strong pycnocline generally at depth 10-20 m is formed by surface fresh water flow which retains sediment in suspension over extended periods.

Sharma, G. D.↗

Vibrations of three-dimensional pipe systems with acoustic coupling

A general algorithm is developed to calculate the beam-type dynamic response of three dimensional multiplane finite length pipe systems, consisting of elbow and straight ducts with continuous interfaces. Emphasis is on secondary acoustic wave effects giving rise to coupling mechanisms; and the simulation accounts for one-dimensional elastoacoustic coupling from a plane acoustic wave and secondary loads resulting from wave asymmetries. The transfer matrix approach is adopted in modeling the elastodynamics of each duct, with allowance for distribution loads. Secondary loads from plane wave distortion are considered with a solution of the Helmholtz equation in an equivalent rigid waveguide, and effects of path imperfection are introduced as a perturbation from the hypothetical perfectly straight pipe. Computations indicate that the one-dimensional acoustic assumption is valid for frequencies below one-half the first cut-off frequency, and the three-dimensional acoustic effects produce an increase in response levels near and above cut-off.

El-Raheb, M.↗

The application and results of a new flight test technique

The application of a flight test maneuver auto-pilot test technique for collecting aerodynamic and structural flight research data on a highly maneuverable aircraft is described. This newly developed flight test technique was applied at the Dryden Flight Research Facility of the NASA Ames Research Center on the highly maneuverable aircraft technology (HiMAT) vehicle. A primary flight experiment was done to verify the design techniques used to develop the HiMAT aerodynamics and structures. This required the collection of large quantities of high-quality pressure distribution, loads, and deflection data. The effectiveness of the flight test technique is illustrated with a flight test example comparing various pressure distribution measurements.

Duke, E. L.↗

Combined Loads Test Fixture for Thermal-Structural Testing Aerospace Vehicle Panel Concepts

A structural test requirement of the National Aero-Space Plane (NASP) program has resulted in the design, fabrication, and implementation of a combined loads test fixture. Principal requirements for the fixture are testing a 4- by 4-ft hat-stiffened panel with combined axial (either tension or compression) and shear load at temperatures ranging from room temperature to 915 F, keeping the test panel stresses caused by the mechanical loads uniform, and thermal stresses caused by non-uniform panel temperatures minimized. The panel represents the side fuselage skin of an experimental aerospace vehicle, and was produced for the NASP program. A comprehensive mechanical loads test program using the new test fixture has been conducted on this panel from room temperature to 500 F. Measured data have been compared with finite-element analyses predictions, verifying that uniform load distributions were achieved by the fixture. The overall correlation of test data with analysis is excellent. The panel stress distributions and temperature distributions are very uniform and fulfill program requirements. This report provides details of an analytical and experimental validation of the combined loads test fixture. Because of its simple design, this unique test fixture can accommodate panels from a variety of aerospace vehicle designs.

Fields, Roger A.↗

Determination of the Stresses Produced by the Landing Impact in the Bulkheads of a Seaplane Bottom

The present report deals with the determination of the impact stresses in the bulkhead floors of a seaplane bottom. The dynamic problem is solved on the assumption of a certain elastic system, the floor being assumed as a weightless elastic beam with concentrated masses at the ends (due to the mass of the float) and with a spring which replaces the elastic action of the keel in the center. The distributed load on the floor is that due to the hydrodynamic force acting over a certain portion of the bottom. The pressure distribution over the width of the float is assumed to follow the Wagner law. The formulas given for the maximum bending moment are derived on the assumption that the keel is relatively elastic, in which case it can be shown that at each instant of time the maximum bending moment is at the point of juncture of the floor with the keel. The bending moment at this point is a function of the half width of the wetted surface c and reaches its maximum value when c is approximately equal to b/2 where b is the half width of the float. In general, however, for computing the bending moment the values of the bending moment at the keel for certain values of c are determined and a curve is drawn. The illustrative sample computation gave for the stresses a result approximately equal to that obtained by the conventional factory computation.

Darevsky, V. M.↗

Short-Term Load Forecasting Error Distributions and Implications for Renewable Integration Studies: Preprint

Load forecasting in the day-ahead timescale is a critical aspect of power system operations that is used in the unit commitment process. It is also an important factor in renewable energy integration studies, where the combination of load and wind or solar forecasting techniques create the net load uncertainty that must be managed by the economic dispatch process or with suitable reserves. An understanding of that load forecasting errors that may be expected in this process can lead to better decisions about the amount of reserves necessary to compensate errors. In this work, we performed a statistical analysis of the day-ahead (and two-day-ahead) load forecasting errors observed in two independent system operators for a one-year period. Comparisons were made with the normal distribution commonly assumed in power system operation simulations used for renewable power integration studies. Further analysis identified time periods when the load is more likely to be under- or overforecast.

17 WIND ENERGY↗

Space shuttle SRM interim contract, part 1

Essential studies and analyses required to integrate the SRM into the booster and overall space shuttle system. Emphasis was placed on the case, nozzle, insulation, and propellant components with resulting performance, weight, and structural load characteristics being generated. Effort conducted during the time period of this contract included studies, analyses, planning, and preliminary design activities. Technical requirements identified in the SRM Project Request for Proposal No. 8-1-4-94-98401 and Thiokol's proposed SRM design (designated Configuration 0) established the basis for this effort. The requirements were evaluated jointly with MSFC and altered where necessary to incorporate new information that evolved after issuance of the RFP and during the course of this interim contract. Revised water impact loads and load distributions were provided based on additional model test data and analytical effort conducted by NASA subsequent to the RFP release. Launch pad peaking loads into the SRM aft skirt were provided which also represented a change from RFP requirements. A modified SRM/External Tank (ET) attachment configuration with new structural load data was supplied by NASA, and direction was received to include a 2 percent inert weight contingency.

Source record↗