Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SPiRaL: a multiresolution global tomography model of seismic wave speeds and radial anisotropy variations in the crust and mantle

SUMMARY SPiRaL is a joint global-scale model of wave speeds (P and S) and anisotropy (vertical transverse isotropy, VTI) variations in the crust and mantle. The model is comprised of >2.1 million nodes with five parameters at each node that capture velocity variations for P- and S-waves travelling at arbitrary directions in transversely isotropic media with a vertical symmetry axis (VTI). The crust (including ice, water, sediments and crystalline layers) is directly incorporated into the model. The default node spacing is approximately 2° in the lower mantle and 1° in the crust and upper mantle. The grid is refined with ∼0.25° minimum node spacing in highly sampled regions of the crust and upper mantle throughout North America and Eurasia. The data considered in the construction of SPiRaL includes millions of body wave traveltimes (crustal, regional and teleseismic phases with multiples) and surface wave (Rayleigh and Love) dispersion. A multiresolution inversion approach is employed to capture long-wavelength heterogeneities commonly depicted in global-scale tomography images as well as more localized details that are typically resolved in more focused regional-scale studies. Our previous work has demonstrated that such global-scale models with regional-scale detail can accurately predict both teleseismic and regional body wave traveltimes, which is necessary for more accurate location of small seismic events that may have limited signal at teleseismic distances. SPiRaL was constructed to predict traveltimes for event location and long-period waveform dispersion for seismic source inversion applications in regions without sufficiently tuned models. SPiRaL may also serve as a starting model for full-waveform inversion (FWI) with the goal of fitting waves with periods 10–50 s over multiple broad regions (thousands of kilometres) and potentially the globe. To gain insight to this possibility, we simulated waveforms for a small set of events using SPiRaL and independent waveform-based models for comparison. For the events tested, the performance of the traveltime-based SPiRaL model is shown to be generally on par with regional 3-D waveform-based models in three regions (western United States, Middle East, Korean Peninsula) suggesting SPiRaL may serve as a starting model for FWI over broad regions.

58 GEOSCIENCES↗

Seismic imaging of the Ecuadorian forearc and arc from joint ambient noise, local, and teleseismic tomography: catching the Nazca slab in the act of flattening

SUMMARY The Ecuadorian Andes are a complex region characterized by accreted oceanic terranes driven by the ongoing subduction of the oceanic Nazca plate beneath South America. Present-day tectonics in Ecuador are linked to the downgoing plate geometry featuring the subduction of the aseismic, oceanic Carnegie Ridge, which is currently entering the trench. Using seismic tomography, we jointly invert arrival times of P and S waves from local and teleseismic earthquakes with surface wave dispersion curves to image the structure of the forearc and magmatic arc of the Ecuadorian Andes. Our data set includes > 100 000 traveltimes recorded at 294 stations across Ecuador. Our images show the basement of the central forearc is composed of accreted oceanic terranes with high elastic wave speeds. Inboard of the Carnegie Ridge, the westernmost forearc and coastal cordilleras display relatively low Vp and Vs and high Vp/Vs values, which we attribute to the increased hydration and fracturing of the overriding plate due to the subduction of the thick oceanic crust of the Carnegie Ridge. We additionally image across-arc differences in magmatic architecture. The frontal volcanic arc overlies accreted terranes and is characterized by low velocities and high Vp/Vs indicative of partial melt reservoirs which are limited to the upper crust. In contrast, the main arc displays regions of partial melt across a wider range of depths. The Subandean zone of Ecuador has two active volcanoes built on continental crust suggesting the arc is expanding eastwards. The mid to lower crust does not show indications of being modified from the magmatic process. We infer that the slab is in the process of flattening as a consequence of early-stage subduction of the buoyant Carnegie Ridge.

58 GEOSCIENCES↗

In-situ heating-and-electron tomography for materials research: from 3D ( In-situ 2D) to 4D ( In-situ 3D)

In-situ observation has expanded the application of transmission electron microscopy (TEM) and has made a significant contribution to materials research and development for energy, biomedical, quantum, etc. Recent technological developments related to in-situ TEM have empowered the incorporation of three-dimensional observation, which was previously considered incompatible. In this review article, we take up heating as the most commonly used external stimulus for in-situ TEM observation and overview recent in-situ TEM studies. Then, we focus on the electron tomography (ET) and in-situ heating combined observation by introducing the authors’ recent research as an example. Assuming that in-situ heating observation is expanded from two dimensions to three dimensions using a conventional TEM apparatus and a commercially available in-situ heating specimen holder, the following in-situ heating-and-ET observation procedure is proposed: (i) use a rapid heating-and-cooling function of a micro-electro-mechanical system holder; (ii) heat and cool the specimen intermittently and (iii) acquire a tilt-series dataset when the specimen heating is stopped. This procedure is not too technically challenging and can have a wide range of applications. Essential technical points for a successful 4D (space and time) observation will be discussed through reviewing the authors’ example application.

36 MATERIALS SCIENCE↗

Atom Probe Tomography Investigation of Clustering in Model P 2 O 5 -Doped Borosilicate Glasses for Nuclear Waste Vitrification

Atom probe tomography (APT) has been utilized to investigate the microstructure of two model borosilicate glasses designed to understand the solubility limits of phosphorous pentoxide (P 2 O 5 ). This component is found in certain high-level radioactive defence wastes destined for vitrification, where phase separation can potentially lead to a number of issues relating to the processing of the glass and its long-term chemical and structural stability. The development of suitable focused ion beam (FIB)-preparation routes and APT analysis conditions were initially determined for the model glasses, before examining their detailed microstructures. In a 3.0 mol% P 2 O 5 -doped glass, both visual inspection and sensitive statistical analysis of the APT data show homogeneous microstructures, while raising the content to 4.0 mol% initiates the formation of phosphorus-enriched nanoscale precipitates. This study confirms the expected inhomogeneities and phase separation of these glasses and offers routes to characterizing these at near-atomic scale resolution using APT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scanning Transmission Electron Microscopy–Atom Probe Tomography Correlative Analysis for the Characterization of Solute-defect Interactions

Atom probe tomography (APT) and (scanning) transmission electron microscopy ((S)TEM) are complementary techniques that provide spatially resolved chemical and structural information at the atomic scale. Here, in this study, we employ two different STEM/APT correlative analysis methods to investigate Cr segregation at dislocation loops in ultra-high purity Fe–Cr alloys. APT needles for the correlative analysis were extracted either from bulk material or from thinned TEM lamellae. STEM analysis was used to determine the Burgers vectors of ion-irradiation-induced dislocation loops, while APT reconstruction of the same region revealed the Cr segregation to these loops. We extended the g•b = 0 invisibility criterion of dislocation loops from TEM mode in a lamella to STEM mode in a needle-shaped specimen. STEM and APT analysis on the same needle provide straightforward correlative analysis, although it is limited by a small observation volume. In contrast, iterative STEM analysis of TEM lamellae, followed by the selective extraction of specific regions of interest for APT analysis, expands the observation area by up to 100 times but requires additional time-consuming steps for APT needle extraction from the lamellae.

47 OTHER INSTRUMENTATION↗

Atom Probe Tomography for the Observation of Hydrogen in Materials: A Review

Atom probe tomography (APT) is an emerging microscopy technique that has high sensitivity for hydrogen with sub-nanometre-scale spatial resolution, which makes it a unique method to investigate the atomic-scale distribution of hydrogen at interfaces and defects in materials. This article introduces the basics of APT-based hydrogen analysis, particularly the challenge of distinguishing a hydrogen background signal in APT by using hydrogen isotopes, along with strategies to yield high-quality analysis. This article also reviews several important findings on hydrogen distribution in a range of materials, including both structural alloys and functional materials, enabled by using APT. Limitations and future opportunities for hydrogen analysis by APT are also discussed.

42 ENGINEERING↗

Evaluation of Electron Tomography Capabilities for Shale Imaging

Despite the advantageous resolution of electron tomography (ET), reconstruction of three-dimensional (3D) images from multiple two-dimensional (2D) projections presents several challenges, including small signal-to-noise ratios, and a limited projection range. This study evaluates the capabilities of ET for thin sections of shale, a complex nanoporous medium. A numerical phantom with 1.24 nm pixel size is constructed based on the tomographic reconstruction of a Barnett shale. A dataset of 2D projection images is numerically generated from the 3D phantom and studied over a range of conditions. First, common reconstruction techniques are used to reconstruct the shale structure. The reconstruction uncertainty is quantified by comparing overall values of storage and transport metrics, as well as the misclassification of pore voxels compared to the phantom. We then select the most robust reconstruction technique and we vary the acquisition conditions to quantify the effect of artifacts. We find a strong agreement for large pores over the different acquisition workflows, while a wider variability exists for nanometer-scale features. Furthermore, the limited projection range and reconstruction are identified as the main experimental bottlenecks, thereby suggesting that sample thinning, advanced holders, and advanced reconstruction algorithms offer opportunities for improvement.

3D scanning transmission electron microscopy↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined computed tomography and position-resolved X-ray diffraction of an intact Roman-era Egyptian portrait mummy

Hawara Portrait Mummy 4, a Roman-era Egyptian portrait mummy, was studied with computed tomography (CT) and with CT-guided synchrotron X-ray diffraction mapping. These are the first X-ray diffraction results obtained non-invasively from objects within a mummy. The CT data showed human remains of a 5-year-old child, consistent with the female (but not the age) depicted on the portrait. Physical trauma was not evident in the skeleton. Diffraction at two different mummy-to-detector separations allowed volumetric mapping of features including wires and inclusions within the wrappings and the skull and femora. Additionally, the largest uncertainty in origin determination was approximately 1.5 mm along the X-ray beam direction, and diffraction- and CT-determined positions matched. Diffraction showed that the wires were a modern dual-phase steel and showed that the 7 × 5 × 3 mm inclusion ventral of the abdomen was calcite. Tracing the 00.2 and 00.4 carbonated apatite (bone's crystalline phase) reflections back to their origins produced cross-sectional maps of the skull and of femora; these maps agreed with transverse CT slices within approximately 1 mm. Coupling CT and position-resolved X-ray diffraction, therefore, offers considerable promise for non-invasive studies of mummies.

60 APPLIED LIFE SCIENCES↗

Characterizing Midcircuit Measurements on a Superconducting Qubit Using Gate Set Tomography

Measurements that occur within the internal layers of a quantum circuit—midcircuit measurements—are a useful quantum-computing primitive, most notably for quantum error correction. Midcircuit measurements have both classical and quantum outputs, so they can be subject to error modes that do not exist for measurements that terminate quantum circuits. In this work, we show how to characterize midcircuit measurements, modeled by quantum instruments, using a technique that we call quantum instrument linear gate set tomography (QILGST). We then apply this technique to characterize a dispersive measurement on a superconducting transmon qubit within a multiqubit system. By varying the delay time between the measurement pulse and subsequent gates, we explore the impact of residual cavity photon population on measurement error. QILGST can resolve different error modes and quantify the total error from a measurement; in our experiment, for delay times above 1000 ns we measure a total error rate (i.e., half diamond distance) of ϵ$\diamond$ = 8.1 ± 1.4%, a readout fidelity of 97.0 ± 0.3%, and output quantum-state fidelities of 96.7 ± 0.6% and 93.7 ± 0.7 % when measuring 0 and 1, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automatic 3D image registration for nano-resolution chemical mapping using synchrotron spectro-tomography

Nano-resolution synchrotron X-ray spectro-tomography has been demonstrated as a powerful tool for probing the three-dimensional (3D) structural and chemical heterogeneity of a sample. By reconstructing a number of tomographic data sets recorded at different X-ray energy levels, the energy-dependent intensity variation in every given voxel fingerprints the corresponding local chemistry. The resolution and accuracy of this method, however, could be jeopardized by non-ideal experimental conditions, e.g. instability in the hardware system and/or in the sample itself. Herein is presented one such case, in which unanticipated sample deformation severely degrades the data quality. Here, to address this issue, an automatic 3D image registration method is implemented to evaluate and correct this effect. The method allows the redox heterogeneity in partially delithiated Li x Ta 0.3 Mn 0.4 O 2 battery cathode particles to be revealed with significantly improved fidelity.

3D image registration↗

Improving reproducibility in synchrotron tomography using implementation-adapted filters

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep-learning methods for contrast enhancement and artifact reduction in cryo-electron tomography: a systematic analysis of the state of the art and proposed improvements

Cryo-electron tomography (cryo-ET) has emerged as the preferred technique for visualizing the organization of macromolecular complexes in situ and resolving their structures at subnanometre resolution [Tegunov et al. (2021)View full citation, Nat. Methods, 18, 186–193]. Despite improvements in data quality as a result of advances in detector technology, microscope stability and stage precision, the analysis and interpretation of tomograms remains challenging due to a low signal-to-noise ratio and reconstruction artifacts stemming from experimental constraints in specimen tilt during data collection resulting in a missing wedge in the Fourier space. Recently, self-supervised deep-learning methods have been proposed for contrast enhancement and reduction of resolution anisotropy in reconstructed tomograms. Here, we evaluate several state-of-the-art deep-learning methods which aim to improve the interpretability of cryo-ET reconstructions, with a focus on their performance on downstream tasks of template matching, sub­tomogram averaging and segmentation. We propose new training architectures and a loss function based on Fourier shell correlation that show improved performance over the standard U-Net with L1/L2 losses. We demonstrate our analysis on four diverse experimental datasets: purified 80S ribosomes, in situ Chlamydomonas reinhardtii, immature HIV-1 virus-like particles and INS-1E cells.

contrast enhancement↗

Composition Quantification of SiGeSn Alloys Through Time-of-Flight Secondary Ion Mass Spectrometry: Calibration Methodologies and Validation With Atom Probe Tomography

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07 < x < 0.83) and Ge1-zSnz (0.066 < z < 0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011 < x < 0.113, 0.863 < y < 0.935 and 0.023 < z < 0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. Furthermore, the proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.

36 MATERIALS SCIENCE↗

MemXCT: Design, Optimization, Scaling, and Reproducibility of X-Ray Tomography Imaging

Here, this work extends our previous research entitled "MemXCT: Memory-centric X-ray CT Reconstruction with Massive Parallelization" that was originally published at SC19 conference (Hidayetoglu et al., 2019) with reproducibility of the computational imaging performance. X-ray computed tomography (XCT) is regularly used at synchrotron light sources to study the internal morphology of materials at high resolution. However, experimental constraints, such as radiation sensitivity, can result in noisy or undersampled measurements. Further, depending on the resolution, sample size and data acquisition rates, the resulting noisy dataset can be in the order of terabytes. Advanced iterative reconstruction techniques can produce high-quality images from noisy measurements, but their computational requirements have made their use an exception rather than the rule. We propose a novel memory-centric approach that avoids redundant computations at the expense of additional memory complexity. We develop a memory-centric iterative reconstruction system, MemXCT, that uses an optimized SpMV implementation with two-level pseudo-Hilbert ordering and multi-stage input buffering. We evaluate MemXCT on various supercomputer architectures involving KNL and GPU. MemXCT can reconstruct a large (11Kx11K) mouse brain tomogram in 10 seconds using 4096 KNL nodes (256K cores). The results presented in our original article at the SC19 were based on large-scale supercomputing resources. The MemXCT application was selected for the Student Cluster Competition (SCC) Reproducibility Challenge and evaluated on a variety of cloud computing resources by universities around the world in the SC20 conference. We summarize the results of the top-ranked SCC Reproducibility Challenge teams and identify the most pertinent measures for ensuring the reproducibility of our experiments in this article.

47 OTHER INSTRUMENTATION↗

Ductile failure and damage localization in Al6061-T6 characterized by in situ X-ray computed tomography and neural network segmentation

Damage initiation and localization in uniaxial tension tests of an Al6061-T6 alloy are evaluated and quantified using in situ X-ray computed tomography and a neural network segmentation strategy. This segmentation strategy offers significant advantages over traditional thresholding in quantifying microstructural and damage evolution metrics. Void nucleation was observed to occur throughout the deformation process, whereas void volume did not grow significantly until later stages of deformation. Localized analysis determined that void nucleation begins in and around the necked region during the early stages of deformation, whereas limited damage nucleation occurs outside of the neck until late stages of deformation. Lastly, inhomogeneities in void and particle spacing in the initial undeformed state of the material are observed to correlate well with the location of damage localization and necking during deformation. These results provide new insights into the ductile failure of Al alloys and how preexisting defects influence damage and rupture.

36 MATERIALS SCIENCE↗

Development of polarization-sensitive optical coherence tomography imaging platform and metrics to quantify electrostimulation-induced peripheral nerve injury in vivo in a small animal model

Neuromodulation devices are rapidly evolving for the treatment of neurological diseases and conditions. Injury from implantation or long-term use without obvious functional losses is often only detectable through terminal histology. New technologies are needed that assess the peripheral nervous system (PNS) under normal and diseased or injured conditions. We aim to demonstrate an imaging and stimulation platform that can elucidate the biological mechanisms and impacts of neurostimulation in the PNS and apply it to the sciatic nerve to extract imaging metrics indicating electrical overstimulation. A sciatic nerve injury model in a 15-rat cohort was observed using a newly developed imaging and stimulation platform that can detect electrical overstimulation effects with polarization-sensitive optical coherence tomography. The sciatic nerve was electrically stimulated using a custom-developed nerve holder with embedded electrodes for 1 h, followed by a 1-h recovery period, delivered at above-threshold Shannon model k-values in experimental groups: sham control (SC, n = 5, 0.0 mA / 0 Hz), stimulation level 1 (SL1, n = 5, 3.4 mA / 50 Hz, and k = 2.57), and stimulation level 2 (SL2, n = 5, 6.8 mA / 100 Hz, and k = 3.17). The stimulation and imaging system successfully captured study data across the cohort. When compared to a SC after a 1-week recovery, the fascicle closest to the stimulation lead showed an average change of +4 % / – 309 % (SL1/SL2) in phase retardation and –79 % / – 148 % in optical attenuation relative to SC. Analysis of immunohistochemistry (IHC) shows a +1 % / – 36 % difference in myelin pixel counts and –13 % / + 29 % difference in axon pixel counts, and an overall increase in cell nuclei pixel count of +20 % / + 35 % . These metrics were consistent with IHC and hematoxylin/eosin tissue section analysis. The poststimulation changes observed in our study are manifestations of nerve injury and repair, specifically degeneration and angiogenesis. Optical imaging metrics quantify these processes and may help evaluate the safety and efficacy of neuromodulation devices.

60 APPLIED LIFE SCIENCES↗

Quantitative Scanning Transmission Electron Microscopy for Materials Science: Imaging, Diffraction, Spectroscopy, and Tomography

Scanning transmission electron microscopy (STEM) is one of the most powerful characterization tools in materials science research. Due to instrumentation developments such as highly coherent electron sources, aberration correctors, and direct electron detectors, STEM experiments can examine the structure and properties of materials at length scales of functional devices and materials down to single atoms. STEM encompasses a wide array of flexible operating modes, including imaging, diffraction, spectroscopy, and 3D tomography experiments. This review outlines many common STEM experimental methods with a focus on quantitative data analysis and simulation methods, especially those enabled by open source software. The hope is to introduce both classic and new experimental methods to materials scientists and summarize recent progress in STEM characterization. The review also discusses the strengths and weaknesses of the various STEM methodologies and briefly considers promising future directions for quantitative STEM research.

36 MATERIALS SCIENCE↗