Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEM imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A study of real-world micrograph data quality and machine learning model robustness

Abstract Machine-learning (ML) techniques hold the potential of enabling efficient quantitative micrograph analysis, but the robustness of ML models with respect to real-world micrograph quality variations has not been carefully evaluated. We collected thousands of scanning electron microscopy (SEM) micrographs for molecular solid materials, in which image pixel intensities vary due to both the microstructure content and microscope instrument conditions. We then built ML models to predict the ultimate compressive strength (UCS) of consolidated molecular solids, by encoding micrographs with different image feature descriptors and training a random forest regressor, and by training an end-to-end deep-learning (DL) model. Results show that instrument-induced pixel intensity signals can affect ML model predictions in a consistently negative way. As a remedy, we explored intensity normalization techniques. It is seen that intensity normalization helps to improve micrograph data quality and ML model robustness, but microscope-induced intensity variations can be difficult to eliminate.

36 MATERIALS SCIENCE↗

Property Variations in Modern REBCO Coated Conductors from Multiple Manufacturers

The complex, multilayer structure of REBCO Coated Conductor (CC) poses significant challenges in the fabrication of high magnetic field devices where large stresses may initiate various forms of damage. Our goal is to peer below the cartoon representations of CC so that, amongst other things, we might better understand whether a CC from one manufacturer is interchangeable with that from another. This involves knowledge of a broad range of electromagnetic, geometric, microstructural, and J c (θ,B,T) properties, and their variations that collectively pose challenges for the fault tolerance of REBCO CC devices. Accordingly, comparative measurements of J c , visualization of flux penetration with Magneto-Optical Imaging (MOI), tape geometry from Scanning Electron Microscopy (SEM) of polished cross-sections, and extensive optical microscopy was performed on recently purchased samples from multiple manufacturers. Our analyses reveal many deviations from or characteristics absent from manufacturers’ specifications, while a comparison of different manufacturers’ mechanically and laser slit tapes shows a diverse array of slitting characteristics amongst the manufacturers and variation in properties those made to the same specification. Laser slit tapes from several manufacturers reveal ablated edges with damaged regions extending up to 50 μm, comparable to the damaged region found in the mechanically slit CC of this study. Overall, the aim of this study is to flesh out appropriate ways to understand the real conductor below the manufacturers’ cartoons to avoid surprises in our REBCO CC coil development program. The goal of this work was to perform a broad array of characterizations of the type needed for validation of purpose for making high field magnets: to our surprise we found a wide range of properties which greatly impact the mechanical strength and electromagnetic performance of solenoids composed of these conductors and reinforced the need for a broad characterization program for each conductor prior to its implementation.

Bradford, G.↗

Contactless Growth of ZnSe Single Crystals by Physical Vapor Transport

ZnSe crystals were grown by self-seeded physical vapor transport (PVT) technique in the horizontal configuration. The source materials were heat treated by H2 reduction to remove the oxide followed by baking under dynamic vacuum to adjust the source composition toward that of congruent sublimation. Contactless growth of ZnSe single crystals have been performed consistently using three different source materials. The crystals grew away from the wall during the later stage of the growth with large (110) facets tend to align parallel to the gravity direction. The Scanning Electron Micrography (SEM) micrographs and the Atomic Force Microscope (AFM) images showed that large (110) terraces and steps dominate the as-grown facets. The measured residual gas pressures in the processed ampoules agree well among various source materials and the major components were CO and H2. No preferred growth direction was found. The one-dimensional diffusion model on the mass flux of a multi-species PVT system was employed to analyze the conditions for contactless growth. The calculated thermal profile for supersaturation is very close to the thermal profile measured inside the empty furnace bore in the region of contactless growth. The effects of convective flows in the vapor phase inside the ampoule on the growth processes are discussed.

Su, Ching-Hua↗

A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for the Surface of Mars: An Instrument for the Planetary Science Community

The Miniaturized Variable Pressure Scanning Electron Microscope(MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Science (ROSES), will build upon previous miniaturized SEM designs for lunar and International Space Station (ISS) applications and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. By the end of the PICASSO work, a prototype of the primary proof-of-concept components (i.e., the electron gun, focusing optics and scanning system)will be assembled and preliminary testing in a Mars analog chamber at the Jet Propulsion Laboratory will be completed to partially fulfill Technology Readiness Level to 5 requirements for those components. The team plans to have Secondary Electron Imaging(SEI), Backscattered Electron (BSE) detection, and Energy Dispersive Spectroscopy (EDS) capabilities through the MVP-SEM.

Mars↗

Characterizing Damage Accumulation in CMCs

Silicon carbide / silicon carbide ceramic matrix composites (SiC/SiC CMCs) are structural ceramics that are well-suited for the extreme environment conditions of aerospace applications largely due to their low weight, creep resistance, damage tolerance, and high specific strength. In CMCs, the initiation and evolution of damage is influenced by a number of factors including characteristics of the constituent landscape (porosity, interfacial properties, and geometric distribution of CMC constituents), thermo-mechanical loading parameters, and environmental conditions. However, much is still unknown about these factors and the interactions between them. In order to accurately predict the lifetimes of these advanced composites, it is critical to understand the evolution of damage and to characterize which early damage mechanisms (and their relationship to key microstructural features) subsequently lead to crack coalescence and macroscopic failure. This research focuses on the use of a multi-modal, experimental approach to examine the relative activity of surface and subsurface damage mechanisms in CMCs. The impact of fabrication choices on the evolution of damage to final failure, and the influence of constituent architecture on early damage mechanisms, are investigated. This approach combines acoustic emission (AE) with microscale deformation tracking via digital image correlation inside a scanning electron microscope (SEM-DIC). The potential application of this combined approach towards characterization of damage in SiC/SiC CMCs under more complex testing conditions is explored.

Swaminathan, Bhavana↗

Effects of low earth orbit on the optical performance of multi-layer enhanced high reflectance mirrors

Two mirror designs developed for space applications were flown along with a standard mid-infrared design on the leading and trailing edges of the Long Duration Exposure Facility (LDEF). Preliminary observations of induced changes in optical performance of ZnS-coated mirrors and impact-related microstructural and microchemical effects are described in the proceedings of the First LDEF Post-Retrieval Symposium. In this paper, effects of the induced environment and meteoroid/debris impacts on mirror performance are described in more detail. Also, an analysis of reflectance spectra using the results of Auger and secondary ion mass spectroscopy (SIMS) profiling measurements are used to identify an optical-degradation mechanism for the ZnS-coated mirrors. Structural damage associated with a high-velocity impact on a (Si/Al2O3)-coated mirror was imaged optically and with scanning electron and atomic force microscopy (SEM and AFM). Scanning Auger and SIMS analysis provided chemical mapping of selected impact sites. The impact data suggest design and fabrication modifications for obtaining improved mechanical performance using a design variation identified in preflight laboratory simulations. Auger surface profile and SIMS imaging data verified the conclusion that secondary impacts are the source of contamination associated with the dendrites grown on the leading-edge ZnS-coated test samples. It was also found that dendrites can be grown in the laboratory by irradiating contaminated sites on a trailing-edge ZnS-coated sample with a rastered electron beam. These results suggest a mechanism for dendrite growth.

Donovan, Terence↗

In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics

A novel, in-situ, scanning electron microscope (SEM) mechanical testing capability for materials at the microscale which provides experimental validation to a machine learning (ML) toolset for full-field validation of physics-based micromechanics models is being developed by researchers at NASA Glenn Research Center. These are enabling technologies for the integration of multiscale digital twins for materials into system level models which will result in the improved performance, material discovery, reduced production cost and time, rapid characterization, and prognostic structural health monitoring (SHM) for materials and structures for extreme environments in support of NASA space exploration missions. In order to bridge the material structure-to-system gap for digital twins, physics-based models must be experimentally validated at multiple length scales. Seminal microscale experiments, conducted at the Air Force Research Laboratory (AFRL), were limited to transverse compression of single-layer, unidirectional thermoset polymer matrix composite (PMC) micropillar specimens [1]. The early phases of the current project followed those initial results and setup to reproduce the compression testing of PMC material on the custom-built piezoelectric actuated micromechanical testing rig built by MicroTesting Solutions LLC. In this work, samples of thermoplastic PMC material were first machined into 3 mm cubes, and then further machining and final milling was done using a Focused Ion Beam (FIB). The initial experiment was done on a pillar roughly 20 µm x 20 µm x 40 µm tall. Additional pillars were milled with final sizes ranging from 20 µm x 20 µm x 40 µm tall to 40 µm x 40 µm x 65 µm tall. A speckle pattern for in-situ full-field measurements using Digital Image Correlation (DIC) was applied with platinum, which was coated on the surface, and then the FIB was used to mill away some of the coating to produce an irregular pattern of Pt on the pillar surface. The samples were loaded into the custom testing rig and placed into the SEM and loaded under compression until failure. Images were collected in the SEM during testing. Post-processing of the images was conducted using DIC to obtain full-field displacement and strain measurements elucidating the role of the matrix as well as fiber-fiber interaction at the microscale within the composite subjected to compression loading well into the non-linear regime of the material. Moreover, the evolution of fiber-matrix debonding and matrix cracking is observed in-situ at the microscale. This data, along with images segmented with a newly developed ML toolset [2], was used to create and validate physics-based micromechanics models. An image of the failed micropillar is shown in Figure 1. The techniques developed in the initial compression experiment was tailored to the validation needs of the models and expanded to include different sized samples as well as possibly tension and fatigue.

Laura Wilson↗

A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for In-Situ Mars Surface Sample Analysis

The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.

Microscope↗

Evidence of lithium mobility under neutron irradiation

Understanding the evolution of intermetallic materials in high-radiation environments is of great importance for fusion science and national security. Tritium ( 3 H) and lithium ( 6 Li, 7 Li) transport within neutron irradiated claddings coated with aluminide (FeAl3) has been investigated using state-of-the-art multimodal imaging. Specifically, scanning electron microscopy – focused ion beam (SEM-FIB) was used to prepare irradiated coating lift-out samples for follow-on microanalysis. Here, scanning transmission electron microscopy (STEM) was used to acquire atomic-scale information on the carbonaceous structure and elemental mapping. Atomic force microscopy (AFM) was used to determine lift-out dimensions nondestructively. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) spectral and depth profiling show unexpected lithium isotopic distributions in the irradiated cladding, raising an important evidence of possible light isotope mobility within the cladding under elevated temperature and irradiation. ToF-SIMS three-dimensional chemical mappings of mid- and bottom-cladding coatings show light isotopic (e.g., 3 H, 6 Li, 7 Li) distributions in the irradiated coating and give new insights into the fundamental mechanism related to transport mechanisms within the cladding. Multimodal imaging is power to link microstructure, chemistry, and nanoscale defects that impact reliability of these materials. Furthermore, chemical mapping offers observations of the microstructural evolution due to irradiation and provides insights into unexpected material transport under extreme conditions.

36 MATERIALS SCIENCE↗

Xylan Is Critical for Proper Bundling and Alignment of Cellulose Microfibrils in Plant Secondary Cell Walls

Plant biomass represents an abundant and increasingly important natural resource and it mainly consists of a number of cell types that have undergone extensive secondary cell wall (SCW) formation. These cell types are abundant in the stems of Arabidopsis, a well-studied model system for hardwood, the wood of eudicot plants. The main constituents of hardwood include cellulose, lignin, and xylan, the latter in the form of glucuronoxylan (GX). The binding of GX to cellulose in the eudicot SCW represents one of the best-understood molecular interactions within plant cell walls. The evenly spaced acetylation and 4-O-methyl glucuronic acid (MeGlcA) substitutions of the xylan polymer backbone facilitates binding in a linear two-fold screw conformation to the hydrophilic side of cellulose and signifies a high level of molecular specificity. However, the wider implications of GX–cellulose interactions for cellulose network formation and SCW architecture have remained less explored. In this study, we seek to expand our knowledge on this by characterizing the cellulose microfibril organization in three well-characterized GX mutants. The selected mutants display a range of GX deficiency from mild to severe, with findings indicating even the weakest mutant having significant perturbations of the cellulose network, as visualized by both scanning electron microscopy (SEM) and atomic force microscopy (AFM). We show by image analysis that microfibril width is increased by as much as three times in the severe mutants compared to the wild type and that the degree of directional dispersion of the fibrils is approximately doubled in all the three mutants. Further, we find that these changes correlate with both altered nanomechanical properties of the SCW, as observed by AFM, and with increases in enzymatic hydrolysis. Results from this study indicate the critical role that normal GX composition has on cellulose bundle formation and cellulose organization as a whole within the SCWs.

09 BIOMASS FUELS↗

Construction of a Virtual Scanning Electron Microscope (VSEM)

The Imaging Technology Group (ITG) proposed to develop a Virtual SEM (VSEM) application and supporting materials as the first installed instrument in NASA s Virtual Laboratory Project. The instrument was to be a simulator modeled after an existing SEM, and was to mimic that real instrument as closely as possible. Virtual samples would be developed and provided along with the instrument, which would be written in Java.

Fried, Glenn↗

Microscopic Observation of Self-Propagation of Calcifying Nanoparticles (Nanobacteria)

Biologists typically define living organisms as carbon and water-based cellular forms with :self-replication" as the fundamental trait of the life process. However, this standard dictionary definition of life does not help scientists to categorize self-replicators like viruses, prions, proteons and artificial life. CNP also named nanobacteria were discovered in early 1990s as about 100 nanometer-sized bacteria-like particles with unique apatite mineral-shells around them, and found to be associated with pathological-calcification related diseases. Although CNP have been isolated and cultured from mammalian blood and diseased calcified tissues, and their biomineralizing properties well established, their biological nature and self-replicating capability have always been severely challenged. The terms "self-replication", "self-assembly" or "self-propagation" have been widely used for all systems including nanomachines, crystals, computer viruses and memes. In a simple taxonomy, all biological and non-biological "self replicators", have been classified into "living" or "nonliving" based on the properties of the systems and the amount of support they require to self-replicate. To enhance our understanding about self-replicating nature of CNP, we have investigated their growth in specific culture conditions using conventional inverted light microscope and BioStation IM, Nikon s latest time-lapse imaging system. Their morphological structure was examined using scanning (SEM) and transmission (TEM) electron microscopy. This present study, in conjunction with previous findings of metabolic activity, antibiotic sensitivity, antibody specificity, morphological aspects and infectivity, all concomitantly validate CNP as living self-replicators.

Mathew, Grace↗

TPSAS-NF1676L-17800-DND

Currently, there are two national challenge problems that guide much of the research in durability and damage tolerance at NASA Langley. The first, Airframe Digital Twin, is a concept that combines as-built vehicle components, as-experienced loads and environments, and other vehicle-specific characteristics to enable ultrahigh fidelity modeling of aircraft and spacecraft throughout their service lives. The second, Materials Genome Initiative, is an analog to the Human Genome Project, and is intended to improve the rate at which materials scientists can discover, understand fundamental physics, and improve material systems. This presentation will highlight several research projects ongoing at NASA Langley that are in support of the above challenge problems. Two of those topics will be the subject of detailed discussion. First, investigations of microstructurally-small fatigue cracking (MSFC) in Al-2Cu and Al-4Cu, fabricated in-house, will be presented. Single- and oligo-crystals of Al-Cu specimens were loaded in uniaxial fatigue, while high-resolution in-situ measurements of deformation were made using image correlation (IC) in a scanning-electron microscope (SEM). The Al-Cu specimens were then replicated as crystal plasticity finite element models (CPFEM), where evolution of slip localization near grain boundaries was computed. Comparison among experiment and CPFEM is made. In addition, XRay diffraction measurements of the as-fabricated specimens were carried out, where direct measurements of the embedded copper precipitates were made, and their influence on growing MSFCs were directly observed. The second main topic will illustrate ongoing work in the area of so-called damage-sensing particles. In this work, shape-memory alloys are embedded in an aluminum alloy matrix. Upon the propagation of a fatigue crack, these particles undergo a strain-induced phase transformation which is detected using an acoustic sensor, providing real-time information on propagating cracks. Experiments and simulations regarding the development of this system will also be detailed.

Jacob Hochhalter↗

Isothermal oxidation of zirconium using steam

Oxidation of zirconium and its alloys under any atmosphere is generally characterised by a protective and non-protective stage. During the protective stage, the kinetics of oxidation are quasi-parabolic, while the oxide scale formed on the surface of the metal is black, compact, and protective in nature. For the non-protective stage, the oxidation rate becomes linear, while the protective oxide film turns into a deteriorated white scale. Breakaway is known as the transition point from protective to non-protective stage. The actual mechanism leading to breakaway of zirconium is still a matter of controversy, however some of the most common factors affecting breakaway are the following: - Impurities on the metal (Carbon, Oxygen, Nitrogen); - Oxidizing atmosphere (Presence of H{sub 2}O (g) or N{sub 2} (g)); - Sample preparation (Chemically etched or polished); - Temperature (LWR, LOCA). This research investigates the effect of temperature on 'breakaway' when zirconium is oxidized isothermally in steam for 60 min at 800 and 900 deg. C using thermogravimetric and optical microscopic imaging techniques. 1. Steam isothermal oxidations were performed on zirconium at 800 and 900 deg. C using a Thermogravimetric Analyzer (TGA). 2. Log-log plots of mass gain vs time were obtained from thermogravimetric results to calculate the reaction orders (n) and reaction rate constants (K) during oxidation. 3. Results of the kinetics of reaction were correlated with optical microscopic images form Light Microscope (LM) and Scanning Electron Microscope (SEM). Breakaway depends very strongly on temperature. At 800 deg. C, the weight gain followed a cubic-parabolic behaviour with evidence of a protective oxide film. On the other hand, oxidation at 900 deg. C showed signs of breakaway since the oxide film was cracked and oxidation rate was almost linear throughout the reaction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Loading Frequency on Fatigue Behavior of Additively Manufactured Short Fiber Thermoplastics via Infrared Thermography

Fracture, Fatigue, Failure, Damage Evolution and Thermomechanics & Infrared Imaging, Volume 4 of the Proceedings of the 2025 SEM Annual Conference & Exposition on Experimental and Applied Mechanics, the fourth volume of five from the Conference, brings together contributions to this important area of research and engineering. The collection presents early findings and case studies on a wide range of areas, including: • 3D Deformation and Failure • In-situ Techniques and Microscale Effects on Mechanical Behavior • Vibration and Cyclic Fatigue • Integration of Models and Experiments • Interface-Mediated Damage and Failure • Fracture and Fatigue in Brittle Materials • Material Characterizations Using Thermography • Fatigue, Damage & Fracture Evaluation Using Infrared Thermography

Pathak, Pharindra [Auburn University]↗

Data Mining – Image Analysis of Radiography for Zr Redistribution

The research effort described in this report represents a first attempt to investigate the radial redistribution of Zr in ternary fuel alloys U-xPu-10Zr (x = 0, 8, 19) irradiated in the in-reactor fuel experiments during the operation of the U.S. Department of Energy’s (DOE’s) Experimental Breeder Reactor II (EBR-II) at Idaho National Laboratory (INL) using methods of image processing on post-irradiation neutron radiographs. Approximately 130,000 metal fuel pins were irradiated in EBR-II during its 30 years of operation to develop and characterize existing and prospective fuels. For many of the metal fuel irradiation experiments, neutron radiography imaging was performed historically now allowing application of modern image analysis techniques to characterize fuel behavior, such as fuel swelling, fluff formation, and now, fuel alloy constituent redistribution. The redistribution of fuel components depends on the temperature field, radially, within the fuel. Specifically, Zr is expected to redistribute radially towards the center of the pin, as well as towards the outer zones. Currently, direct imaging of a pin cross-section through optical methods or scanning electron microscopy (SEM) is used to study the constituents’ redistribution, which is very time-consuming and can only be applied to a limited number of pins. An automated image processing technique allowing for the investigation of fuel radial redistribution zones would significantly accelerate data analysis. In general, if the fuel temperature is hot enough, three redistribution zones are expected, corresponding to the main fuel components (e.g., U, Pu, Zr). While more assessment will be performed in fiscal year (FY)-2023, it seems possible to differentiate the pins according to their fuel composition using image analysis techniques on neutron radiographs of metallic fuel pins based on the analysis to date.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The MOCHII ISS National Laboratory: The First Spacecraft Based Scanning Electron Microscope

Introduction: Scanning electron microscopy (SEM) in concert with element identification by energy dispersive Xray (EDX) spectroscopy has become an indispensable tool in the analyses of extraterrestrial materials. Nevertheless, to-date, SEM-EDX instrumentation has remained purely in the purview of terrestrial laboratories due to their size, complexity, and operational requirements. However, in January 2022 a miniaturized SEM-EDX called MOCHII became the first successful space-based instrument of its kind, following its deployment onboard the International Space Station (ISS). It represents the culmination of nearly 40 years of technological development. We have performed an on-orbit study with MOCHII with the goal of evaluating its potential as the progenitor of a new generation of spacecraftbased instruments for use in future manned and robotic planetary exploration missions. Out goal has been to validate the on-orbit investigation of samples relevant to astromaterials and astrobiology. We have performed in-situ analyses on standards and a freshly fractured fragment of the Martian meteorite Allan Hills 84001 which was first analyzed, prior to launch, using an engineering MOCHII ground unit located at Johnson Space Center in Houston. Results of both imaging and compositional analyses substantiates the utility of remote SEM-EDX analyses in low Earth orbit (LEO).

Miniature Scanning Electron Microscope↗

NanoSIP: NanoSIMS Applications for Microbial Biology

High-resolution imaging with secondary ion mass spectrometry (nanoSIMS) has become a standard method in systems biology and environmental biogeochemistry and is broadly used to decipher ecophysiological traits of environmental microorganisms, metabolic processes in plant and animal tissues, and cross-kingdom symbioses. When combined with stable isotope-labeling—an approach we refer to as nanoSIP—nanoSIMS imaging offers a distinctive means to quantify net assimilation rates and stoichiometry of individual cell-sized particles in both low- and high-complexity environments. While the majority of nanoSIP studies in environmental and microbial biology have focused on nitrogen and carbon metabolism (using 15 N and 13 C tracers), multiple advances have pushed the capabilities of this approach in the past decade. The development of a high-brightness oxygen ion source has enabled high-resolution metal analyses that are easier to perform, allowing quantification of metal distribution in cells and environmental particles. New preparation methods, tools for automated data extraction from large data sets, and analytical approaches that push the limits of sensitivity and spatial resolution have allowed for more robust characterization of populations ranging from marine archaea to fungi and viruses. Further, NanoSIMS studies continue to be enhanced by correlation with orthogonal imaging and ‘omics approaches; when linked to molecular visualization methods, such as in situ hybridization and antibody labeling, these techniques enable in situ function to be linked to microbial identity and gene expression. Here we present an updated description of the primary materials, methods, and calculations used for nanoSIP, with an emphasis on recent advances in nanoSIMS applications, key methodological steps, and potential pitfalls.

07 ISOTOPE AND RADIATION SOURCES↗