Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Pressure dependence of Poisson’s ratio of glassy Baltic amber studied by Brillouin scattering spectroscopy

Amber is a typical natural glass with very long aging time. Elastic properties of amber at high pressures have been studied using Brillouin scattering and a diamond anvil cell. Both longitudinal and transverse acoustic modes have been observed up to 12 GPa. The pressure dependences of longitudinal, shear, Young’s, and bulk moduli, compressibility, and Poisson’s ratio were determined. The longitudinal, shear, Young’s, bulk moduli show the remarkable increase, and compressibility shows a marked decrease with increasing pressure. However, it is found that the pressure dependence of Poisson’s ratio is very small. The mechanism of this small pressure dependence was discussed. Finally, the Cauchy type relation between longitudinal and shear moduli was examined. Its coefficients show the deviation from the Cauchy relation owing to the coexistence of different intermolecular interactions in amber.

07 ISOTOPE AND RADIATION SOURCES↗

A CO-to-H{sub 2} Ratio of ≈10{sup -5} toward the Herbig Ae Star HK Ori

Measurements of gas mass in protoplanetary gas disks form the basis for estimating the conditions of planet formation. Among the most important constraints derived from disk diagnostics are the abundances of gas-phase species critical for understanding disk chemistry. Toward this end, we present direct line-of-sight measurements of H{sub 2} and CO, employing UV absorption spectroscopy from Hubble Space Telescope Cosmic Origins Spectrograph to characterize disk composition, molecular excitation temperatures, and spatial distribution in the circumstellar material around the Herbig Ae stars HK Ori and T Ori. We observe strong CO (N(CO) = 10{sup 15.5} cm{sup −2}; T {sub rot}(CO) = 19 K) and H{sub 2} (N(H{sub 2}) = 10{sup 20.34} cm{sup −2}; T {sub rot}(H{sub 2}) = 141 K) absorption toward HK Ori with a CO/H{sub 2} ratio of (≡N(CO)/N(H{sub 2})) = 1.3{sub −0.7}{sup +1.6} × 10{sup −5}. These measurements place direct empirical constraints on the CO-to-H{sub 2} conversion factor in the disk around a Herbig Ae star for the first time, although there is uncertainty concerning the exact viewing geometry of the disk. The spectra of T Ori show CO (N(CO) = 10{sup 14.9} cm{sup −2}; T {sub rot}(CO) = 124 K) absorption. Interestingly, we do not detect any H{sub 2} absorption toward this star (N(H{sub 2}) < 10{sup 15.9} cm{sup −2}). We discuss a potential scenario for the detection of CO without H{sub 2}, which deserves further investigation. The low abundance ratio measured around HK Ori suggests significant depletion of CO in the circumstellar gas, which conforms with the handful of other recent CO abundance measurements in protoplanetary disks.

47 OTHER INSTRUMENTATION↗

The Chocolate Chip Cookie Model: Dust-to-metal Ratio of H ii Regions

Using a sample of face-on star-forming galaxies selected from the Sloan Digital Sky Survey, we statistically derive the typical optical depth $\tau$ cl of individual H II regions based on the "Chocolate Chip Cookie" model of Lu et al. (2022). By binning galaxies into stellar mass and gas-phase metallicity bins and interpreting $\tau$ cl as the dust-to-gas ratio (DGR) of H II regions, we further investigate the correlations between DGR and stellar mass and between DGR and gas-phase metallicity, respectively. We find that DGR increases monotonically with the stellar mass of galaxies. At a given stellar mass, DGR shows a linear correlation with the gas-phase metallicity, which implies a constant dust-to-metal ratio (DTM) of galaxies at a given stellar mass. These results adequately indicate that the DTM of galaxies is simply a function of their stellar masses. In terms of gas-phase metallicity, because of the mass–metallicity relation, DTM increases with increasing metallicity with a power-law index 1.45 in the low-metallicity region, while it remains constant at the high-metallicity end.

79 ASTRONOMY AND ASTROPHYSICS↗

Achieving Diesel-Like Efficiency in a High Stroke-to-Bore Ratio DISI Engine under Stoichiometric Operation

This work explores pathways to achieve diesel-like, high-efficiency combustion with stoichiometric 3-way catalyst compatible spark ignition (SI). A high stroke-to-bore engine design (1.5:1) with cooled exhaust gas recirculation (EGR) and high compression ratio (r c ) was used to improve engine efficiency by up to 30% compared with a production turbocharged gasoline direct injection spark ignition engine. To achieve efficiency improvements, engine experiments were coupled with computational fluid dynamics simulations to guide and explain experimental trends between the original engine and the high stroke-to-bore ratio design (1.5:1). The effects of EGR and late intake valve closing (IVC) and fuel characteristics are investigated through their effects on knock mitigation. Direct injection of 91 RON E10 gasoline, 99 RON E0 gasoline, and liquified petroleum gas (i.e., propane/autogas) were evaluated with geometric rc ranging from 13.3:1 to 16.8:1. Finally, engine experiments demonstrated 47% gross thermal efficiency, and 45% net thermal efficiency at stoichiometric engine operation, at up to 17 bar IMEP and 2000 r/min with 16.8:1 rc.

42 ENGINEERING↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

System and method for control of compression in internal combustion engine via compression ratio and elastic piston

The present disclosure relates to a system for controlling ignition of an air/fuel mixture intake charge directed into an internal combustion engine. The system may have a longitudinally movable inner cylinder liner configured to fit within a cylinder wall portion of an internal combustion engine, and able to receive a piston of the engine therein. A portion of the inner cylinder liner defines an internal volume forming a combustion chamber, and the internal volume controls a compression ratio of the cylinder. The system also has a cylinder head assembly operatively associated with the inner cylinder liner and able to move linearly to cause longitudinal displacement of the inner cylinder liner relative to the cylinder wall portion. This enables the volume of the combustion chamber to be further varied, to thus further vary the compression ratio.

Flowers, Daniel L.↗

Neutron-induced capture-to-fission cross section ratio measured at LANSCE

Capture-to-fission cross section ratios are used as an alternative to absolute cross section measurements. This is due to the simplification on the calculations and the reduction of the uncertainties with respect to an absolute measurement of the cross section by eliminating experimental complications like self-absorption, beam/target overlap and non-uniformities. Different capture-to-fission reactions have been measured through the years at the Los Alamos Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL) using the Detector for Advanced Neutron Capture Experiments (DANCE) combined with different fission detectors. Some of these are a Parallel Plate Avalanche Counter (PPAC) to detect fission fragments (FF), and the NEUtron detector array at DANCE (NEUANCE) to detect fission neutrons. As DANCE detects the γ-rays produced in capture and fission reactions, the fission instrument placed inside the DANCE cavity is used to tag the fission γ-rays for background identification and subtraction. Some examples of capture-to-fission ratio measurements performed with DANCE in the last years are the 233 U, 235 U and 239 Pu. The measurement technique, the different setups, and other potential applications of the instruments will be explained.

Nuclear Criticality Safety Program (NCSP)↗

Development of online pulse-finding algorithms for the Mu2e Stopping Target Monitor and an evaluation of the signal to background ratio for the Mu2e stopped-muon rate determination

This thesis presents a determination of the acceptance of the Mu2e Stopping Target Monitor (STM) detector for both signal and background events. The rate of X-rays of a specific energy in the STM is used to determine the rate of stopped muons in the aluminium stopping target, which is used as the normalisation for all Mu2e measurements, particularly the branching ratio for a charged lepton flavour violating (cLFV) process. The acceptance for the 347\,keV $2p-1s$ aluminium signal X-ray is determined to be $(8.03 \pm 0.05) \times 10^{-10}$\,cm$^{-2}$ and the acceptance for the background photons (at 347\,keV) to be $(3.19 \pm 0.21) \times 10^{-8}$\,cm$^{-2}$. This results in a signal-to-background ratio of approximately two which is significantly higher than had previously been estimated. These signal-to-background rates are used to determine the time required to achieve a statistical uncertainty of 10\% on the number of 347\,keV X-rays as a function of the detector resolution and back ground rate. For a resolution of 2\,keV, and the background rate determined in this thesis, approximately one minute of data is required. The three corrections needed to be applied to the measured 347\,keV rate to determine the rate of stopped muons are also determined and potential sources of bias arising from the background shape, background fit range and energy calibration are investigated and found to be insignificant. The raw energy of the particles in the STM detector comes from a 16-bit ADC digitising at $\sim 300$\,MHz. It is not possible to store all the raw digitisations and online algorithms have been developed to rapidly select pulses in the detector and reconstruct their energy. The performance of these algorithms has been characterised with simulated data as a function of detector rate and resolution and optimum operating points for the algorithms have been defined. The integrity of the algorithms has also been demonstrated and characterised on test-beam data at high r ates and with radioactive sources at low rates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Experimental Investigation of Air-Fuel Equivalence Ratio Effects on Advanced Dual-fuel Diesel/Ammonia Combustion on a Single-Cylinder Medium-Duty Diesel Engine at High Load

Ammonia (NH3) has gathered a lot of interest as a low-lifecycle-carbon fuel in sectors with high weight and distance requirements, such as shipping. The International Maritime Organization (IMO) mandates a 70-80% greenhouse gas (GHG) reduction by 2040, which is only possible with advanced engine technologies and fuels like NH3. Prior research studies at the US Department of Energy’s Oak Ridge National Laboratory have shown strong performance with NH3 under dual-fuel mode using conventional diesel combustion (CDC) manifold air pressure (MAP) settings. Diesel airflow was initially used to simplify retrofitting (no turbocharger modification), which resulted in air-fuel equivalence ratios (λ) greater than 1.5. To characterize potential improvements in dual-fuel NH3 combustion performance at richer in-cylinder conditions, a global λ sweep using a diesel pilot ignition (DPI) strategy with diesel fuel injected near top-dead center (TDC) and a reactivity-controlled compression ignition (RCCI) injection strategy with diesel fuel injected earlier during the compression stroke were compared. The experiments were conducted at 1200 RPM and 12.6 bar (75% load), and λ was varied by decreasing the commanded air flow to the engine at greater than 90% ammonia energy substitution (AES) level. A diesel injection timing sweep was conducted for both the combustion modes at fixed λ, and the timing with the lowest engine-out N2O emissions was identified. The results indicated an optimal balance between CO2, eq and thermal efficiency benefits for both DPI and RCCI injection strategy cases compared to CDC at a λ of 1.4. The indicated N-based emissions exhibited a strong correlation to the ratio of CA5–50 and ignition delay for DPI, but no apparent trend emerged for the RCCI injection strategy at the tested boundary conditions.

Tyrewala, Daanish [ORNL] (ORCID:0000000208599324)↗

Validation of the DESI-DR1 3x2-pt analysis: scale cut and shear ratio tests

Combined survey analyses of galaxy clustering and weak gravitational lensing (3x2-pt studies) will allow new and accurate tests of the standard cosmological model. However, careful validation is necessary to ensure that these cosmological constraints are not biased by uncertainties associated with the modelling of astrophysical or systematic effects. In this study we validate the combined 3x2-pt analysis of the Dark Energy Spectroscopic Instrument Data Release 1 (DESI-DR1) spectroscopic galaxy clustering and overlapping weak lensing datasets from the Kilo-Degree Survey (KiDS), the Dark Energy Survey (DES), and the Hyper-Suprime-Cam Survey (HSC). By propagating the modelling uncertainties associated with the non-linear matter power spectrum, non-linear galaxy bias and baryon feedback, we design scale cuts to ensure that measurements of the matter density and the amplitude of the matter power spectrum are biased by less than 30% of the statistical error. We also test the internal consistency of the data and weak lensing systematics by performing new measurements of the lensing shear ratio. We demonstrate that the DESI-DR1 shear ratios can be successfully fit by the same model used to describe cosmic shear correlations, and analyse the additional information that can be extracted about the source redshift distributions and intrinsic alignment parameters. This study serves as crucial preparation for the upcoming cosmological parameter analysis of these datasets.

Emas, N. [Swinburne U., Ctr. Astrophys. Supercompu↗

Measurement of the Neutron Elastic Electromagnetic Form Factor Ratio at Large Momentum Transfer

Exploring nucleon structure is vital both for understanding its origin and existence as well as for the advancement of the sciences. It helps us answer key questions such as how quark and gluon dynamics create 99% of the nucleon mass. Electron- nucleon scattering has been widely used for precision studies of the nucleon and nuclear structure since the Nobel Prize winning investigations by Robert Hofstadter and collaborators in the 1950s. These studies provide information about the spatial charge and current densities of the nucleon in terms of the electromagnetic form factors. The form factors are functions of four momentum transfer squared (Q2). Extending the electromagnetic form factor measurements to higher Q2 plays a critical role in furthering the understanding of nucleon structure. This motivated the Super BigBite Spectrometer (SBS) program at Jefferson Lab. The open nature of the spectrometers and the direct line of sight from the target to the tracking detector locations in experimental setups such as SBS creates high levels of background at the detectors. This necessitates the use of tracking detectors with high rate capability and good position resolution. Gas Electron Multiplier (GEM) detectors are an excellent choice for tracking detectors in such experiments. Understanding the performance of the GEM detectors is important not just for SBS experiments but also for future high-luminosity experiments. This thesis reports the exploratory results from the measurement of the neutron elastic electromagnetic form factor ratio (Gn E/Gn M) at high momentum transfer. A longitudinally polarized electron beam was scattered off a polarized 3He target, used as an effective polarized neutron target. In this experiment, the polarized 3He target achieved a world record polarization weighted luminosity at a beam current of 45 µA. Double spin asymmetry of the scattered neutron events is used to extract the neutron form factor ratio. Measurements were taken at Q2 = 3.0, 6.8, 9.8 (GeV/c)2. The lowest Q2 measurement is in good agreement with the existing world data, and the higher-Q2 measurements extend the Q2 reach well beyond the existing world data and are expected to remain unmatched for a long time.

Gamage, Vimukthi Haththotuwa [Univ. of Virginia, C↗

Strong Lensing Cosmology with Population-level Calibrated Neural Ratio Estimation

Strong gravitational lensing contains key information about cosmic acceleration. Modern and next-generation galaxy imaging surveys are expected to provide high-quality data on $\mathcal{O}(10^5)$ galaxy-galaxy lensing systems. The plethora and complexity of the data are likely to present computational challenges for parameter inference methods for fitting high-dimensional likelihoods, which are often analytically intractable. Neural Ratio Estimation (NRE) efficiently computes individual likelihood ratios that can be combined into population-level posteriors. We use simulations to study the capacity of NRE to jointly predict the dark energy equation-of-state parameter $w$ and the total matter density $Ω_{m}$ from lensing images and companion spectroscopic information. We also introduce a post hoc posterior coverage calibration procedure that mitigates the model overconfidence that is typically found in neural density estimation applications. Our experiments show that the errors on both parameters decrease with increasing inference population sizes. In particular, for 100 lenses in a standard $Λ$CDM Universe, our calibrated NRE model achieves median fractional uncertainty of $22.8\%$ in $w$ and $2.9\%$ in $Ω_{m}$. This proof of concept demonstrates a potentially scalable approach for efficient cosmological parameter inference with large populations of galaxy-scale lenses observed in future surveys.

Jarugula, Sreevani [Fermilab] (ORCID:0000000253867↗

Remote Sensing Low Signal-to-Noise-Ratio Target Detection Enhancement

In real-time remote sensing application, frames of data are continuously flowing into the processing system. The capability of detecting objects of interest and tracking them as they move is crucial to many critical surveillance and monitoring missions. Detecting small objects using remote sensors is an ongoing, challenging problem. Since object(s) are located far away from the sensor, the target’s Signal-to-Noise-Ratio (SNR) is low. The Limit of Detection (LOD) for remote sensors is bounded by what is observable on each image frame. In this paper, we present a new method, a “Multi-frame Moving Object Detection System (MMODS)”, to detect small, low SNR objects that are beyond what a human can observe in a single video frame. This is demonstrated by using simulated data where our technology-detected objects are as small as one pixel with a targeted SNR, close to 1:1. We also demonstrate a similar improvement using live data collected with a remote camera. The MMODS technology fills a major technology gap in remote sensing surveillance applications for small target detection. Our method does not require prior knowledge about the environment, pre-labeled targets, or training data to effectively detect and track slow- and fast-moving targets, regardless of the size or the distance.

47 OTHER INSTRUMENTATION↗

ABC -Auxetics: An Implicit Design Approach for Negative Poisson's Ratio Materials

A novel methodology is introduced for designing auxetic (negative Poisson's ratio) structures based on topological principles and is demonstrated by investigating a new class of auxetics based on two-dimensional (2D) textile weave patterns. Conventional methodology for designing auxetic materials typically involves determining a single deformable block (a unit cell) of material whose shape results in auxetic behavior. Consequently, patterning such a unit cell in a 2D (or 3D) domain results in a larger structure that exhibits overall auxetic behavior. Such an approach naturally relies on some prior intuition and experience regarding which unit cells may be auxetic. Second, tuning the properties of the resulting structures is typically limited to parametric variations of the geometry of a specific type of unit cell. Thus, most of the currently known auxetic structures belong to a selected few classes of unit cell geometries that are explicitly defined in accordance with a specified topological (i.e., grid structure). Herein, a new class of auxetic structures is demonstrated that, while periodic, can be generated implicitly, i.e., without reference to a specific unit cell design. The approach leverages weave-based parameters (A–B–C), resulting in a rich design space for auxetics that is previously unexplored.

36 MATERIALS SCIENCE↗

Manipulating Na/TM Ratio‐Driven Structural Heterogeneity of O3‐NaNi 1/3 Fe 1/3 Mn 1/3 O 2 Cathode for High‐Voltage Sodium‐Ion Batteries

The stability of O3-type NaNi 1/3 Fe 1/3 Mn 1/3 O 2 under high-voltage cycling is dictated by how synthesis encodes lattice strain and redox heterogeneity. Here, in this study, the role of Na:TM stoichiometry is systematically resolved by tuning the NaOH:precursor ratio during solid-state synthesis. The stoichiometric condition (Na:TM = 1.00) yields minimized microstrain, enabling uniform O3–P3 phase evolution and homogeneous multi-metal redox with preserved octahedral symmetry. In contrast, Na-excess compositions inherit disordered intermediates and heterogeneous distortion fields that trigger abrupt multiphase transitions and promote localized charge redistribution. In situ XRD captures the divergence in phase-transition pathways, TXM resolves particle-level redox heterogeneity, and XANES corroborates a stronger and more reversible Fe redox contribution at stoichiometry, shifting to diminished Fe participation and spatially inhomogeneous redox at higher Na content. These results establish Na:TM stoichiometry as a critical synthesis parameter controlling both structural coherence and redox stability. Electrochemically, the stoichiometric composition exhibits smooth voltage profiles with minimal polarization growth and retains nearly 80% of its initial capacity after 100 cycles even at an extended 4.2 V cutoff, whereas Na-excess compositions show significantly reduced initial coulombic efficiency and rapid voltage fade. Precise stoichiometric tuning provides a scalable route to defect-suppressed O3 frameworks, enabling structurally resilient, high-voltage sodium-layered cathodes.

36 MATERIALS SCIENCE↗

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗