Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Morrow1 Model - No Capillary Pressure

Farnsworth Unit (FWU) CO2EOR Eclipse compositional model: Morrow1 model uses the Morrow1 relative permeability curve with no capillary pressure assigned.

capillary pressure↗

Morrow1 Model - with Capillary Pressure

Farnsworth Unit (FWU) CO2EOR Eclipse compositional model: Morrow1 model uses the Morrow1 relative permeability curve with capillary pressure assigned homogeneously

Capillary Pressure↗

Hydrostratigraphic Region 4 Model - with HSUPc

Farnsworth Unit (FWU) CO2EOR Eclipse compositional model: Hydrostratigraphic Region 4 model uses the Morrow2 (UNOCAL) relative permeability curve with capillary pressure assigned heterogeneously by hydrostratigraphic unit

Capillary Pressure↗

Hydrostratigraphic Region 4 Model - with HSU3-4Pc

Farnsworth Unit (FWU) CO2EOR Eclipse compositional model: Hydrostratigraphic Region 4 model uses the Morrow2 (UNOCAL) relative permeability curve with HSU3-4 capillary pressure assigned homogeneously

Capillary Pressure↗

Hydrostratigraphic Region 1 Model

Farnsworth Unit (FWU) CO2EOR Eclipse compositional model: Hydrostratigraphic Region 1 model uses the HS1 relative permeability curves assigned heterogeneously by hydrostratigraphic unit. The model with capillary pressure applies the HS1 curves heterogeneously by hydrostratigraphic unit.

Capillary Pressure↗

Hydrostratigraphic Region 3 Model - with and without HSU Capillary Pressure

Farnsworth Unit (FWU) CO2EOR Eclipse compositional model: Hydrostratigraphic Region 3 model uses the HS3 relative permeability curves assigned heterogeneously by hydrostratigraphic unit. The model with capillary pressure applies the HS3 curves heterogeneously by hydrostratigraphic unit.

Capillary Pressure↗

Farnsworth Unit Gas Composition Analyses

This data set includes gas composition analyses that were provided to the Southwest Regional Partnership on Carbon Sequestration (SWP) by the operators of the Farnsworth Field Unit in Ochiltree County Texas.

CO2 CCUS,Farnsworth,Gas Compositions,Morrow Sandst↗

Integrated Flue Gas Purification and Latent Heat Recovery for Pressurized Oxy-Combustion (Final Scientific/Technical Report)

Pressurized oxy-combustion has been identified by DOE as a transformational technology for coal power with carbon capture due to the advantages that are realized when the combustion process is pressurized. The staged pressurized oxy-combustion (SPOC) process is particularly attractive as the efficiency of the process is almost 6 percentage points greater than that of first generation oxy-combustion. A critical component of the SPOC process, and potentially other pressurized combustion processes, is the Direct Contact Cooler (DCC) where the latent heat of the flue gas moisture is recovery to improve plant efficiency while simultaneously removing SO x and NO x from the flue gas, so that the FGD and de-NO x processes can be eliminated, and the cost of electricity minimized. The objective of this R&D effort was to advance the TRL of the DCC technology, which included performance testing at a 100 kW scale to validate the process and obtain key engineering data for scale-up. A collateral objective was to study the gas- and liquid-phase kinetics, and the development of a systematic chemical mechanism validated by experimental data. Experiments in a bench-scale stirred reactor provided an updated understanding of the liquid chemistry and the effects of temperature and pH. This information was used to develop a reduced reaction mechanism, which was subsequently incorporated in an ASPENbased process model, to allow for evaluation of the DCC at full scale. A small-pilot DCC column was designed, constructed and tested using simulated flue gas at the pressurized oxy-combustion test facility at Washington University in St. Louis. In the majority of tests, the SO 2 capture approached 100%, making the NO x capture the primary metric of capture efficiency. An NO x capture efficiency of 90% was achieved when the gas residence time was 95 seconds, demonstrating that high capture rates can be attained with reasonable reactor size. At higher temperatures (up to 200°C inlet gas temperature) the total NO x scrubbing efficiency was reduced by approximately 10% (compared to room temp.) and this was attributed to a reduced NO oxidation rate. A significant amount of SO 2 was present in the gas outlet (10%) only when the temperature was high and the N:S ratio was low (N/S < 1), which highlights the necessity of controlling the NOx concentration in the flue gas for complete sulfur scrubbing. After incorporated our optimized chemical mechanism into an ASPEN process model, various full-scale configurations of the DCC were evaluate, and the results indicate that the proposed DCC can accomplish its intended goals at full scale and at a modest size. Thus, the results of this project indicate that the DCC is a promising technology for recovery of the latent heat of the moisture in the flue gas while simultaneously scrubbing the nitrogen and sulfur oxides, thus enabling pressurized oxy-combustion, in general, and the SPOC process, in particular.

01 COAL, LIGNITE, AND PEAT↗

Techno-Economic Analysis of CO 2 Capture-Ready Coal-Fired Power Plants

This analysis evaluates CO 2 capture-ready supercritical pulverized coal units. Cost and performance results are presented for capture-ready coal units that achieve a 30-year average emission rate of 1,000 Lb CO 2 /MWh. The analysis also includes a detailed discussion of the specific elements that comprise a capture-ready unit, as well as different design strategies to minimize costs. The benefits of R&D advances such as 2nd generation CO 2 capture, and additional revenue from CO 2 sales for enhanced oil recovery, are also presented, and are compared to other baseload generation options, such as natural gas combined cycle and nuclear.

01 COAL, LIGNITE, AND PEAT↗

CarbonSAFE Rocky Mountain Phase I: Ensuring Safe Subsurface Storage of Carbon Dioxide in the Intermountain West

An integrated CCS pre-feasibility study, CarbonSAF E Rocky Mountain Phase I, was conducted by the U niversity of Utah and its partners as part of the US D epartment of Energy’s Carbon Storage Assurance a nd Facility Enterprise (CarbonSAFE) program. The a ssembled project team consisted of academic, indus try and governmental agencies covering the technic al and non- technical challenges of a commercial-sc ale CO 2 storage facility capable of storing 50 million tonnes of anthropogenically-sourced CO 2 . The Rock y Mountain CarbonSAFE team identified the Hunter Power Plant in central Utah as the primary source of CO 2 on which this study would be focused. The nea rby Huntington power plant, also operated by Rocky Mountain Power, was evaluated as a secondary sou rce of CO 2 . The Hunter plant was chosen because o f an interest in CO 2 capture technology by the plant operator, Rocky Mountain Power, and also because i t is a representative example of a typical coal-fired g enerating station in the Rocky Mountain west. Amine -based and cryogenic-based capture assessments w ere performed for approximately 3 million tonnes per year for one of the boiler units at the Hunter plant, yi elding cost of capture estimates of $\$56$/tonne and $\$4 1.50$/tonne. Transportation and intermediate compre ssion would increase the per tonne costs, but will be highly dependent on specific injection locations and available rights-of-way. A high-level technical sub-ba sinal evaluation was performed on the area surround ing the Hunter and Huntington power plants to verify CO 2 storage capacity and integrity. Initial geologic c haracterization efforts focused on sites immediately adjacent to the Hunter plant, including the deep eolia n Permian White Rim Sandstone, which in outcrop a nd core from other locations indicates high permeabi lity and high porosity. However, petrophysical logs fr om wells near Hunter indicate porosity of only 2-4%. As a result, potential injection sites were moved stru cturally down-dip (to the west), into the high permea bility (~200 mD) and high porosity (20%) Navajo san dstone. A comprehensive analysis of the reservoir a nd seals was conducted, providing data to the model , simulation and risk assessment groups on the proje ct. CO 2 capacity estimates for the Navajo Sandston e approximately 18 kilometers from the Hunter plant are well in excess of the 50 million tonnes goal of the project. Area of Review Delineation and Risk Asse ssment on the Navajo, associated seals and shallow groundwater aquifers identified the most significant risks and mitigation options. A non-technical assessment to a commercial-scale CO 2 storage facility in central Utah was conducted. EPA Underground Injection Control Class VI and National Environmental Policy Act permitting present particularly challenging issues related to the development of any saline aquifer for CO 2 storage, including the area around the Hunter plant. While surface and subsurface ownership and ri ghts are not straightforward, especially on any privat e land, many of the stakeholders in central Utah are accustomed and open to oil/gas/mineral-related activities similar to what would be required for CO 2 storage sites.

01 COAL, LIGNITE, AND PEAT↗

Cryogenic Carbon Capture Development (Final Report)

This project extends and leverages the work completed under funding from ARPA-E and other sources by exploring aspects of the Cryogenic Carbon Capture™ (CCC) process and issues discovered during those projects, but that were not within the scope or budget of previous projects or that became apparent during field tests. Our successful completion of the tasks outlined in this project has increased the reliability, efficiency, and scalability of the CCC process and we are better prepared for pilot-scale testing. The first phase of this project improved key areas of the process through iterative design and experiment, culminating with recommendations for improvements to the existing skid-scale system developed under non-federal funding. The second phase of this project implemented the improved unit operations into the Cryogenic Carbon Capture External Cooling Loop (CCC ECL™) skid and field tests the improved system at a coal-fired power plant. The specific areas of work in this project are: Budget Period 1: 1) Selection of the most energy-efficient drying system for ambient-pressure flue gas. Sustainable Energy Solutions, LLC (SES) has successfully demonstrated a dryer that removes bulk water using a low-temperature brine to remove about 99% of the water followed by a mol sieve 3A desiccant dryer to remove the remaining 1% water; 2) Selection and demonstration of efficient solution to fouling due to dissolved CO 2 . SES has tested several commercial heat exchangers that purport to be able to handle fouling issues similar to those experienced in the contact liquid chiller. Replicated tests using the CCC ECL™ skid and dimpled brazed plate heat exchangers demonstrate that quick throttling of refrigerant combined with a burst of clean gas mitigate the fouling caused by CO 2 solubility in contact liquid with only minor increases in parasitic load. SES models indicate that parasitic load would increase by approximately 0.0125 GJ/tonne, an order of magnitude less than what was determined to be the maximum allowable additional parasitic load caused by this system; 3) Selection and demonstration of efficient and scalable solid–liquid separation system. The screw press technology met or exceeded the 70% solids loading benchmark during several test runs exceeding 24 hours on the CCC ECL™ skid. The average solids loading during the entire 50-hour run was 67%. The energy demand for this system is less than 0.1 GJ e /tonne of CO 2 processed; 4) Optimize design and demonstration of patented desublimating heat exchangers. We designed and built a hybrid spray tower that was tested over many hundreds of hours and a 50-hour continuous test run was completed capturing over 0.5 tonne CO 2 /day at >90% capture; (5) Plan for safe dilution of oxygen-depleted, cleaned flue-gas stream. The AERSCREEN simulator developed by the EPA modeled the dispersion of oxygen-depleted flue gas from the CCC process at a commercial plant. The results indicate that this plan effectively mitigates the flue gas hazards; (6) Simulation of and experimental work related to multi-pollutant capture. SES programmed an upgrade to its solid/vapor/liquid equilibrium (SVLE) algorithm. This enables simultaneous modeling of multiple pollutants (i.e., CO 2 , SO x , NO x , Hg, HCl). Budget Period 2; (7) Modify the CCC ECL™ skid for field testing and complete shakedown testing. The plans for modifying the CCC ECL™ skid were finalized and put into place. Shakedown testing of the updated CCC ECL™ skid occurred at SES using closed-loop mode (i.e., using a synthetic flue gas consisting of only N 2 and CO 2 ) and at the Hunter Power Plant using flue gas from the coal-fired boiler. Shakedown testing took longer than expected due to delays in receiving equipment and unexpected equipment performance in the field; (8) Operate the CCC ECL™ skid in the field. Longer testing of the CCC ECL™ skid occurred at the Hunter Power Plant. Multiple tests exceeding 35 hours were completed, with a total of over 600 hours of CO 2 capture completed using flue gas at the Hunter Power Plant with an average CO 2 capture rate of over 91% during those hours. Extensive notes and documentation were acquired informing improved methods for controls, startup, operation, and shut down; (9) Determine figures of merit and quantify process improvement. SES defined figures of merit for unit operation performance and overall CCC ECL™ process performance. All figures of merit were achieved or surpassed, except for 500 continuous hours of demonstration at the Hunter Power Plant; (10) Complete an Environmental Health and Safety Risk assessment by a third party. Tri-State completed an Environmental Health and Safety Risk assessment; (11) Update techno-economic analysis with third-party validation. The techno-economic analysis has been completed. It confirms the potential large reduction in energy and cost of the CCC process compared with leading alternatives and that the estimates and estimation techniques are reliable.

20 FOSSIL-FUELED POWER PLANTS↗

Cryogenic Carbon Capture Development Final/Technical Report

This project extends and leverages the work completed under funding from ARPA-E and other sources by exploring aspects of the Cryogenic Carbon Capture™ (CCC) process and issues discovered during those projects, but that were not within the scope or budget of previous projects or that became apparent during field tests. Our successful completion of the tasks outlined in this project has increased the reliability, efficiency, and scalability of the CCC process and we are better prepared for pilot-scale testing. The first phase of this project improved key areas of the process through iterative design and experiment, culminating with recommendations for improvements to the existing skid-scale system developed under non-federal funding. The second phase of this project implemented the improved unit operations into the Cryogenic Carbon Capture External Cooling Loop (CCC ECL™) skid and field tests the improved system at a coal-fired power plant.

20 FOSSIL-FUELED POWER PLANTS↗

Using Machine Learning to Identify Optimum Prospects for Offshore Geologic CO 2 Storage and Enhanced Oil Recovery in the Gulf of Mexico

The SECARB Offshore Partnership is a government-industry partnership focused on assembling the knowledge base required for secure, long-term, large-scale CO 2 subsea storage in saline formations and mature oil reservoirs. The SECARB Offshore Partnership is evaluating potential storage opportunities in the Central and Eastern planning areas of the outer continental shelf (OCS) of the Gulf of Mexico. The evaluation focuses on active and depleted oil and gas fields and potentially associated CO 2 -enhanced oil recovery (CO 2 -EOR), as well as, deep saline storage resources. As part of Subtask 3.0 (Offshore Storage Resources Characterization) and Subtask 4.0 (Risk Assessment, Simulation, and Modeling), Oklahoma State University (OSU) is developing a machine learning system that employs the SAS Institute’s Viya platform with visual data mining and machine learning to identify and characterize optimum prospects for enhanced oil recovery and stacked storage in saline reservoirs. This report summarizes this effort to date and discusses the many variables that can be used to characterize these storage objectives, as well as, the design vision of the Viya machine learning system.

02 PETROLEUM↗

Characterization of Offshore Storage Resource Potential in the Central Planning Area of the Gulf of Mexico

This report contains a brief overview of the several studies that provide the basis for this work and details the reservoir characterization efforts that have been completed to date. Briefly, geological characterization data suggests that the deep-water reservoirs are the result of the interplay between turbidite depositional systems and salt tectonics. Project Partners have estimated the CO 2 storage capacity associated with saline reservoirs and that associated with CO 2 -Enhanced Oil Recovery (EOR) in the state waters of Louisiana. In addition, Project Partners have conducted a detailed analysis of CO 2 storage potential associated with CO 2 -EOR in the central planning area of the GOM. This work estimates that 3,140 million metric tonnes of CO 2 can be stored in optimal reservoirs of the shallow- and deep-water central GOM. A reduced order modeling and machine learning approach is introduced that will be used to evaluate CO 2 storage capacity and plume dynamics for down-selected, reservoir-specific, saline characterization. Last, a brief discussion establishes how the data presented in this report will support future work.

02 PETROLEUM↗