Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Performance Study of K2CsSb Photocathode Inside a DC High Voltage Gun

In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K{sub 2}CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the K{sub 2}CsSb photocathode inside a DC gun. Since the multialkali cathode is a compound with constant characteristics over its entire thickness, we anticipate that the lifetime issues seen in GaAs:Cs due to surface damage by ion bombardment would be minimized. Hence successful operation of the K{sub 2}CsSb cathode in a DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of a K{sub 2}CsSb cathode in a DC gun, we have designed and built a load lock system that allows the fabrication of the cathode at Brookhaven National Lab (BNL) and its testing at Jefferson Lab (JLab). In this paper, we will present the performance of the K{sub 2}CsSb photocathode in the preparation chamber and in the DC gun.

43 PARTICLE ACCELERATORS↗

Simulations of Surface Effects and Electron Emission from Diamond-Amplifier Cathodes

Emission of electrons in diamond experiments based on the promising diamond-amplifier concept was recently demonstrated. Transmission mode experiments have shown the potential to realize over two orders of magnitude charge amplification. However, the recent emission experiments indicate that surface effects should be understood in detail to build cathodes with optimal properties. We have made progress in understanding secondary electron generation and charge transport in diamond with models we implemented in the VORPAL particle-in-cell computational framework. We introduce models that we have been implementing for surface effects (band bending and electron affinity), charge trapping, and electron emission from diamond. Then, we present results from 3D VORPAL diamond-vacuum simulations with the integrated capabilities on generating electrons and holes, initiated by energetic primary electrons, charge transport, and then emission of electrons from diamond into vacuum. Finally, we discuss simulation results on the dependence of the electron emission on diamond surface properties.

43 PARTICLE ACCELERATORS↗

First Demonstration of Electron Beam Generation and Characterization With an All Superconducting Radio-Frequency (SRF) Photoinjector

In preparation for a high brightness, high average current electron source for the energy recovery linac BERLinPro an all superconducting radio-frequency (SRF) photoinjector is now in operation at Helmholtz-Zentrum Berlin. The aim of this experiment is beam demonstration with a high brightness electron source able to generate short, few ps long pulse length electron bunches from a superconducting (SC) cathode film made of Pb coated on the backplane of a Nb SRF cavity. This paper describes the setup of the experiment, first results from beam measurements and capabilities of the source derived from beam dynamics considerations. In April 2011 the photoinjector generated and accelerated for the first time electron beam. This result marks the highlight of the project running for two years starting with project approval in May 2009.

43 PARTICLE ACCELERATORS↗

First Characterization of a Fully Superconducting RF Photoinjector Cavity

As a first step towards a high brightness, high average current electron source for the BERLinPro ERL a fully superconducting photo-injector was developed by HZB in collaboration with Jefferson Laboratory, DESY and the A. Soltan Institute. This cavity-injector ensemble is made up of a 1.6-cell superconducting cavity with a superconducting lead cathode deposited on the half-cell backwall. A superconducting solenoid is used for emittance compensation. This system, including a diagnostics beamline, has been installed in the HoBiCaT facility to serve as a testbed for beam dynamics studies and to test the combination SRF cavity and superconducting solenoid. This paper summarizes the characterization of the cavity in this configuration including Q measurements, dark current tests and field-stability analyzes.

43 PARTICLE ACCELERATORS↗

EVALUATION OF SILICON DIODES AS IN-SITU CRYOGENIC FIELD EMISSION DETECTORS FOR SRF CAVITY DEVELOPMENT

We performed in-situ cryogenic testing of four silicon diodes as possible candidates for field emission (FE) monitors of superconducting radio frequency (SRF) cavities during qualification testing and in accelerator cryo-modules. We evaluated diodes from 2 companies - from Hamamatsu corporation model S1223-01; and from OSI Optoelectronics models OSD35-LR-A, XUV-50C, and FIL-UV20. The measurements were done by placing the diodes in superfluid liquid helium near the top of a field emitting 9-cell cavity during its vertical test. For each diode, we will discuss their viability as a 2K cryogenic detector for FE mapping of SRF cavities and the directionality of S1223-01 in such environments. We will also present calibration curves between the diodes and JLab's standard radiation detector placed above the Dewar's top plate.

43 PARTICLE ACCELERATORS↗

Diamond X-ray Beam Position Monitors

Modern Synchrotrons are capable of significant per-pulse x-ray flux, and time resolved pulse-probe experiments have become feasible. These experiments provide unique demands on x-ray monitors, as the beam position, flux and arrival time all potentially need to be recorded for each x-ray pulse. Further, monitoring of white x-ray beam position and flux upstream of beamline optics is desirable as a diagnostic of the electron source and insertion device alignment. We report on diamond quadrant monitors which provide beam diagnostics for a variety of applications, for both white and monochromatic beams. These devices have a position resolution of 25 nm for a stable beam, are linear in flux over at least 11 orders of magnitude, and can resolve beam motion shot-by-shot at repetition rates up to 6.5 MHz.

43 PARTICLE ACCELERATORS↗

High Efficiency Visible Photocathode Development

The alkali antimonides are of significant interest to the accelerator community, as they have a high quantum efficiency (QE) under illumination by green light. These cathodes are attractive for high-average-current photoinjector applications and understanding their fundamental properties are critical to the production of long lived, reliable cathodes. We report on ongoing work to characterize cathode formation during growth. In-situ X-ray Diffraction (XRD) has been used to compare grain size and texture in antimony layers, and X-ray Photoelectron Spectroscopy (XPS) has been used to investigate the solid-state chemistry of cathode formation.

36 MATERIALS SCIENCE↗

Detector positioning for the initial subcriticality level determination in accelerator-driven systems

Within the GUINEVERE project (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) carried out at SCK-CEN in Mol, the continuous deuteron accelerator GENEPI-3C was coupled to the VENUS-F fast simulated lead-cooled reactor. Today the FREYA project (Fast Reactor Experiments for hYbrid Applications) is ongoing to study the neutronic behavior of this Accelerator Driven System (ADS) during different phases of operation. In particular the set-up of a monitoring system for the subcriticality of an ADS is envisaged to guarantee safe operation of the installation. The methodology for subcriticality monitoring in ADS takes into account the determination of the initial subcriticality level, the monitoring of reactivity variations, and interim cross-checking. At start-up, the Pulsed Neutron Source (PNS) technique is envisaged to determine the initial subcriticality level. Thanks to its reference critical state, the PNS technique can be validated on the VENUS-F core. A detector positioning methodology for the PNS technique is set up in this paper for the subcritical VENUS-F core, based on the reduction of higher harmonics in a static evaluation of the Sjoestrand area method. A first case study is provided on the VENUS-F core. This method can be generalised in order to create general rules for detector positions and types for full-scale ADS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recovery of Neptunium-236g from Photon and Proton-Irradiated Actinide Targets

Neptunium-236g is a rare radionuclide used as a tracer for neptunium-237 analyses. The availability of 236gNp is limited and the viable production routes are costly, time consuming, and only produce trace quantities of the desired product. For this work, two known production methods were tested to determine product recovery, purity, and viability for use as a tracer. The first method utilizes a photon-irradiated 237Np target to produce 236gNp by the 237Np(?,n)?236Np reaction. The second method utilizes the 238U(d,4n) ?236Np reaction. These production routes were evaluated previously, and the former was considered ineffective without isotope separation and the latter was not well-characterized for the 236mNp/236gNp production ratio. Recent resurgence of electromagnetic isotope separation technology has enabled at least partial recovery of 236gNp from part-per-million abundance feeds produced by the photonuclear reaction. To address the lack of production data for the second method, a deuteron-irradiated depleted uranium target was chemically processed to recover and purify the Np for abundance and ratio analyses. The status and current analytical results for each production method are presented.

07 ISOTOPE AND RADIATION SOURCES↗

X-ray streak camera temporal resolution improvement using a longitudinal time-dependent field

X-ray streak cameras (XSC) have been known to be one of the fastest detectors forultrafast X-ray science. A number of applications in material science, biochemistry, accelerator physics, require sub-picosecond resolution to study new phenomena. Inthis paper, we report on a new method which can potentially improve the temporal resolution of a streak camera down to 100 femtoseconds. This method uses a time-dependent acceleration field to lengthen the photoelectron bunch, significantlyimproving the time resolution as well as reducing the time dispersion caused byinitial energy spread and the effects fromthe space charge forces. A computer simulation of an XSC using this method shows significant improvement in the resolution.

43 PARTICLE ACCELERATORS↗

Microgravity acceleration measurement and environment characterization science (17-IML-1)

The Space Acceleration Measurement System (SAMS) is a general purpose instrumentation system designed to measure the accelerations onboard the Shuttle Orbiter and Shuttle/Spacelab vehicles. These measurements are used to support microgravity experiments and investigation into the microgravity environment of the vehicle. Acceleration measurements can be made at locations remote from the SAMS main instrumentation unit by the use of up to three remote triaxial sensor heads. The prime objective for SAMS on the International Microgravity Lab (IML-1) mission will be to measure the accelerations experienced by the Fluid Experiment System (FES). The SAMS acceleration measurements for FES will be complemented by low level, low frequency acceleration measurements made by the Orbital Acceleration Research Experiment (OARE) installed on the shuttle. Secondary objectives for SAMS will be to measure accelerations at several specific locations to enable the acceleration transfer function of the Spacelab module to be analyzed. This analysis effort will be in conjunction with similar measurements analyses on other Spacelab missions.

Source record↗

MUSETT and the Spectroscopy of Heavy Elements at GANIL

The new MUSETT silicon-wall has been built to study and obtain detailed spectroscopic information on the transfermium and transactinide elements. MUSETT is located at GANIL at the detection plane of VAMOS, the latter coupled with the EXOGAM germanium array. Results from the in-beam commissioning are reported and an overview of our future experimental program will be given.

43 PARTICLE ACCELERATORS↗

High gradient research and facilities at Los Alamos National Laboratory [Slides]

A particle accelerator is a scientific instrument that produces a directional stream of electrically charged particles, usually electrons or protons. The accelerator propels particles to high speeds, close to the speed of light. Historically, accelerators play a crucial role in scientific discovery. Nowadays, accelerators produce particle beams for biomedical and material research, manufacturing, energy technology, and Homeland security.

43 PARTICLE ACCELERATORS↗

A 6 kV arbitrary waveform generator for the Tevatron Electron Lens

This paper reports on a 6 kV modulator built and installed at Fermilab to drive the electron gun anode for the Tevatron Electron Lens (TEL). The TEL was built with the intention of shifting the individual (anti)proton bunch tunes to even out the tune spread among all 36 bunches with the desire of improving Tevatron integrated luminosity. This modulator is essentially a 6 kV arbitrary waveform generator that enables the TEL to define the electron beam intensity on a bunch-by-bunch basis. A voltage waveform is constructed having a 7 μs duration that corresponds to the tune shift requirements of a 12-bunch (anti)proton beam pulse train. This waveform is played out for any one or all three bunch trains in the Tevatron. The programmed waveform voltages transition to different levels at time intervals corresponding to the 395 ns bunch spacing. In addition, complex voltage waveforms can be played out at a sustained rate of 143 kHz over the full 6 kV output range. This paper describes the novel design of the inductive adder topology employing five transformers. It describes the design aspects that minimize switching losses for this multi-kilovolt, high repetition rate and high duty factor application.

43 PARTICLE ACCELERATORS↗

A Dual-Sided Coded-Aperture Radiation Detection System , Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment

We report the development of a large-area, mobile, coded-aperture radiation imaging system for localizing compact radioactive sources in three dimensions while rejecting distributed background. The 3D Stand-Off Radiation Detection System (SORDS-3D) has been tested at speeds up to 95 km/h and has detected and located sources in the millicurie range at distances of over 100 m. Radiation data are imaged to a geospatially mapped world grid with a nominal 1.25- to 2.5-m pixel pitch at distances out to 120 m on either side of the platform. Source elevation is also extracted. Imaged radiation alarms are superimposed on a side-facing video log that can be played back for direct localization of sources in buildings in urban environments. The system utilizes a 37-element array of 5 x 5 x 50 cm{sup 3} cesium-iodide (sodium) detectors. Scintillation light is collected by a pair of photomultiplier tubes placed at either end of each detector, with the detectors achieving an energy resolution of 6.15% FWHM (662 keV) and a position resolution along their length of 5 cm FWHM. The imaging system generates a dual-sided two-dimensional image allowing users to efficiently survey a large area. Imaged radiation data and raw spectra are forwarded to the RadioNuclide Analysis Kit (RNAK), developed by our collaborators, for isotope ID. An intuitive real-time display aids users in performing searches. Detector calibration is dynamically maintained by monitoring the potassium-40 peak and digitally adjusting individual detector gains. We have recently realized improvements, both in isotope identification and in distinguishing compact sources from background, through the installation of optimal-filter reconstruction kernels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the ESS cryogenic system

The European Spallation Source (ESS) is a neutron science facility funded by a collaboration of 17 European countries currently under design and construction in Lund, Sweden. The centerpiece of ESS is a 2.5 GeV proton linac utilizing superconducting RF cavities operating at 2 K. In addition to cooling the SRF cavities, cryogenics is also used at ESS in the liquid hydrogen moderators surrounding the target. ESS also uses both liquid helium and liquid nitrogen in a number of the planned neutron instruments. There is also a significant cryogenic installation associated with the site acceptance testing of the ESS cryomodules. The ESS cryogenic system consists of 3 separate helium refrigeration/liquefaction plants supplying the accelerator, target moderators and instruments. An extensive cryogenic distribution system connects the accelerator cryoplant with the cryomodules. This paper describes the preliminary design of the ESS cryogenic system including the expected heat loads. Challenges associated with the required high reliability and turn-down capability will also be discussed. A unique feature of ESS is its commitment to sustainability and energy recovery. A conceptual design for recovering waste heat from the helium compressors for use in the Lund district heating system will also be described.

43 PARTICLE ACCELERATORS↗