ULTRAFAST HIGH-VOLTAGE KICKER SYSTEM HARDWARE FOR ION CLEARING GAPS

Ionization scattering of electron beams with residual gas molecules causes ion trapping in electron rings, both in a collider and electron cooling system. These trapped ions may cause emittance growth, tune shift, halo formation, and coherent coupled bunch instabilities. To clear the ions and prevent them from accumulating turn after turn, the gaps in a temporal structure of the beam are used. Typi- cally, the gap in the bunch train has a length of a few per- cent of the ring circumference. In those regions, the extrac- tion electrodes with high pulsed voltages are introduced. In this paper, we present the design consideration and initial test results of the high-voltage pulsed kicker hardware that includes vacuum device and pulsed voltage driver, capable of achieving over 3 kV of deflecting voltage amplitude, rise and fall times of less than 10 ns, 100 ns flat-top duration at 1.4 MHz repetition rate.

Smirnov, A.↗

A High-Voltage High-Reliability Scalable Architecture for Electric Vehicle Power Electronics (Final Report)

This project developed and demonstrated new composite converter technologies that lead to high power density (> 20 kW/L) at power levels of 10s of kW, 100s of kW, or possibly higher, with fundamental advances in converter efficiency and Q that lead to substantial increases in mean time to failure (MTTF). These advantages were realized through development of new composite converter topologies that perform buck, boost, or other conversion functions and that are scalable to higher voltage and power levels through sharing of voltage and current stresses among multiple dissimilar partial-power converter modules. The project led to experimental demonstration of a125 kW multifunction electric vehicle power conversion system having in-creased dc bus voltage (950 V nominal, 1200 V peak) that interfaces a 200 V to 400 V battery pack, and that includes integrated level 2 wired charging and wireless charging functions. The project incorporated SiC MOSFET modules having switching frequencies in excess of 100 kHz, planar magnetics, a hierarchical control architecture that enables scaling to higher voltages and powers with additional converter modules, and a high-power density in excess of 20 kW/L. The research demonstrated how a more complex converter approach can increase mean-time-to-failure, even though the number of elements is increased. This is achieved through significant reduction of temperature rise through fundamentally superior converter circuit topologies. The research also demonstrated new high power planar magnetics that increase power density. The technology is appropriate to a variety of applications including EV power trains, EV charging, PV inverters, battery storage, and similar areas. These systems potentially can be manufactured in the U.S.

33 ADVANCED PROPULSION SYSTEMS↗

Synchrophasor-Based Zonal Current Differential Protection for Secondary Low Voltage Networks

This report describes an approach to utilizing phasor measurement unit (PMU) data from multiple Intelligent Electronics Devices (IEDs) in a low-voltage network to produce a differential scheme for protecting the medium-voltage feeder and low-voltage network transformers. The proposed protection scheme is designed and prototyped on a real-time automation controller. Its performance is evaluated using real-time controller hardware-in-the-loop simulation. Lab testing results indicate that the proposed protection scheme allows significant distributed energy resources (DER) backfeed and enables selective and fast protection of medium voltage feeders.

42 ENGINEERING↗

GA-Based Voltage Optimization of Distribution Feeder with High-Penetration of DERs Using Megawatt-Scale Units

In this paper, genetic algorithm (GA)-based voltage optimization of a modified IEEE-34 node distribution feeder with high penetration of distributed energy resources (DERs) is proposed using two megawatt-scale reactive power sources. Traditional voltage support units present in distribution grids are not suitable for DER-rich feeders, while voltage support using small-scale DERs present in the feeder requires considerable communication effort to reach a global solution. In this work, two megawatt-scale units are placed to improve the voltage profile across the IEEE 34-node feeder, which has been modified to include several PV units and an energy storage unit. The megawatt-scale units are optimized using GA for fast and accurate operation. The performance of the proposed scheme is verified using simulation results with a multi-platform setup where the modified IEEE-34 node feeder is modeled in OpenDSS while the GA optimization scheme is programmed in MATLAB.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Service Limits Smart Contract Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Generator

Modern electrical grids face growing stability risks from customer-owned generators, especially at points of common couplings (PCCs). Disruptive behavior from power-electronic sources can cause protective relays to isolate problematic generators, making measurement integrity critical. This article presents a distributed ledger technology (DLT) approach that uses smart contracts to evaluate PCC voltage measurements and trigger backup breaker operations. The approach is framed as a verifiable, multi-organization attestation and audit layer, not as a real-time control security mechanism. In the proposed architecture, voltage measurements from a hardware protective relay are anchored on a DLT through the Cyber Grid Guard (CGG) system for attestation by both the grid utility and customer-owned generator. A Voltage Service Limits (VSLs) smart contract evaluates the on-chain measurements against allowable phase-voltage limits derived from the ANSI C84.1 standard. The framework is validated in a hardware-relay-in-the-loop test bed under sustained-undervoltage, sustained-overvoltage, and transient line-to-line fault scenarios. The results show that the VSL smart contract can process these measurements and issue backup breaker actions consistent with the defined service-limit criteria, demonstrating the DLT potential as a verifiable audit layer at the PCC that complements primary protection.

cyber security↗

High voltage, cross-field, gas switch and method of operation

A high voltage gas switch includes a gas-tight housing containing an ionizable gas at a preselected gas pressure. The gas switch includes a gas-tight housing containing an ionizable gas at a gas pressure selected based upon a Paschen curve for the ionizable gas, where the Paschen curve plots breakdown voltages of the ionizable gas as a function of gas pressure multiplied by grid-to-anode distance, and where values of gas pressure multiplied by grid-to-anode distance increase over at least a portion of the Paschen curve in conjunction with increasing breakdown voltages. The gas switch also includes an anode disposed within the gas-tight housing, a cathode disposed within the gas-tight housing, and a control grid positioned between the anode and the cathode, where the control grid is spaced apart from the anode by a grid-to-anode distance selected based upon a desired operating voltage.

42 ENGINEERING↗

Subcritical-voltage magnetron RF power source

A system and method of operating a magnetron power source can achieve a broad range of output power control by operating a magnetron with its cathode voltage lower than that needed for free running oscillations (e.g., below the Kapitsa critical voltage or equivalently below the Hartree voltage) A sufficiently strong injection-locking signal enables the output power to be coherently generated and to be controlled over a broad power range by small changes in the cathode voltage. In one embodiment, the present system and method is used for a practical, single, frequency-locked 2-magnetron system design.

30 DIRECT ENERGY CONVERSION↗

Decentralized Voltage optimization Method for Distribution Networks with Distributed PVs

In order to solve the voltage violations caused by high penetration distributed photovoltaics (PVs), this paper proposes a decentralized voltage optimization method for distribution networks. Through the optimal dispatch of distributed PVs and reactive power resources, it realizes the voltage security and economic operation of distribution systems and facilitates the integration of massive distributed PVs. The proposed method is inspired by the idea of locational marginal price (LMP) and feasible cutting plane. It separates the optimization of boundary bus voltage and power flow in adjacent regions and uses the interaction of boundary variables’ marginal prices to obtain the optimal solution. The effectiveness and accuracy of the proposed method are demonstrated via simulation test on a practical l0kV feeder in China.

Xue, Yaosuo↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking

As distributed energy resources (DERs) play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled HELICS-based co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. These results are compared to the same distribution system run without co-simulation using a fixed feed-in voltage. Results show that even without advanced voltage controls, the feed-in voltage response when coupled to the transmission system results a lower level of voltage excursions, suggesting the importance of using this type of realistic, tightly coupled, transmission and distribution co-simulation when assessing DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

High-voltage insulator having multiple materials

High-voltage insulators are disclosed that are capable of handling diverse requirements, such as providing high standoff voltages, high temperature cycling, and the ability to withstand flexural stress. One high-voltage insulator includes a first piece formed from a first material, a second piece formed from a second material, and an interface section where the first piece contacts with and forms a seal with the second piece. The interface includes a first groove located that accommodates a first gasket, sets of matching threads on the first and second pieces. The interface section further accommodates a second gasket. In this multi-piece high-voltage insulator, the first material can have a first set of flexural, heat resistance, and electrical standoff characteristics suitable for a first environment, and the second material can have a second set of flexural, heat resistance and electrical standoff characteristics suitable for a second environment.

Podpaly, Yuri Anatoly↗

Hierarchical distributed voltage regulation

Embodiments of the disclosure provide for hierarchically distributed voltage regulation and power flow optimization in a power distribution network. According to one embodiment, a regional coordinator system may determine power flow for an autonomous grid (AG) representing a portion of the distribution network based on a set of voltage parameters from nodes in the AG. The set of voltage parameters my include a current voltage magnitude. The regional coordinator system may provide, to a central controller system of the distribution network, one or more power flow parameters based on the determined power flow for the AG.

Zhou, Xinyang↗

A Smart Silicon Carbide Power Module With Pulse Width Modulation Over Wi-Fi and Wireless Power Transfer-Enabled Gate Driver, Featuring Onboard State of Health Estimator and High-Voltage Scaling Capabilities: Preprint

A wide range of utility applications require controllable switches with features such as high-voltage (HV) blocking and high-current carrying capacity especially at high pulse width modulation (PWM) frequency. Low and medium voltage utility applications such as motor drives and flexible AC transmission systems (FACTS) as well as solid state transformers (SST) could also benefit from a low-cost HV switching module. Wide band gap (WBG) semiconductors such as SiC and GaN MOSFETs are considered to be the present and next generation device choices, although they have their own limitations. For relatively HV applications with demanding thermal management, SiC is still the only choice, and GaN dominates the low voltage regime. This manuscript proposes a new half bridge power MOSFET module that is suitable for conventional H-bridge of multilevel configurations used in HV applications. Constructed from bare SiC dies, this half bridge module takes advantage of (1) optimized MOSFET placement inside the module, (2) customized heat exchanger, manifold and cooling, (3) integrated gate driver module with PWM over wi-fi to eliminate the need for low voltage signals, (4) wireless power transfer (WPT) enabled gate driver and other ancillary circuits, (5) and the option to incorporate an onboard state of health (SOH) estimator module onboard. The entire architecture has been designed and built at National Renewable Energy Laboratory (NREL), Golden, CO.

baseplate design↗

Masked fault detection for reliable low voltage cache operation

Systems, apparatuses, and methods for implementing masked fault detection for reliable low voltage cache operation are disclosed. A processor includes a cache that can operate at a relatively low voltage level to conserve power. However, at low voltage levels, the cache is more likely to suffer from bit errors. To mitigate the bit errors occurring in cache lines at low voltage levels, the cache employs a strategy to uncover masked faults during runtime accesses to data by actual software applications. For example, on the first read of a given cache line, the data of the given cache line is inverted and written back to the same data array entry. Also, the error correction bits are regenerated for the inverted data. On a second read of the given cache line, if the fault population of the given cache line changes, then the given cache line's error protection level is updated.

Ganapathy, Shrikanth↗

High-voltage insulators having multiple materials

High-voltage insulators are disclosed that are capable of handling diverse requirements, such as providing high standoff voltages, high temperature cycling, and the ability to withstand flexural stress. One high-voltage insulator includes a first piece formed from a first material, a second piece formed from a second material, and an interface section where the first piece contacts with and forms a seal with the second piece. The interface includes a first groove located that accommodates a first gasket, sets of matching threads on the first and second pieces. The interface section further accommodates a second gasket. In this multi-piece high-voltage insulator, the first material can have a first set of flexural, heat resistance, and electrical standoff characteristics suitable for a first environment, and the second material can have a second set of flexural, heat resistance and electrical standoff characteristics suitable for a second environment.

Podpaly, Yuri Anatoly↗

Field Testing of PID-p Susceptible Bifacial PERC Modules: Impact of Light, Voltage and Module History ​

This work investigates the potential induced degradation-polarization (PID-p) of bifacial passivated emitter and rear contact (PERC) modules installed in the field at the Florida Solar Energy Center. 22 modules were stressed over 1 year under various voltage (-1500V, -3500, +1500V) and mounting configurations (close to ground, 2 meters from ground, close to roof). The positively stressed modules were anticipated to have experiences PID-p on their front side. However, no degradation was observed, as the light-induced recovery effect effectively counteracted the degradation. The negatively stressed modules experienced Pmax drops during 2 weeks before stabilizing at 5-6% loss. I-V and EL characteristics suggest a PID-p degradation on the rear side. Lower degradation rates are observed with lower voltage and when the mounting configuration allows more albedo light on the rear side to compensate for the degradation. PID-p is observed to stabilize at similar level for the voltage and mounting configuration tested with slightly lower Pmax in winter. EL imaging reveals that cells are not degrading at the same rate across a module. Some cells get darker and then brighter which corresponds to the silicon/passivation interface going through depletion and then inversion when enough positive charges are accumulated. After full light-recovery, the modules were tested again along with 22 brand-new ones to assess the impact of the module history. Results confirmed the trends observed in the first year with PID-p occurring at voltage as low as -600V and recovered modules degrading faster than brand-new ones.

14 SOLAR ENERGY↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Superior long-term cycling of high-voltage lithium-ion batteries enabled by single-solvent electrolyte

A new single-solvent electrolyte system comprising lithium bis(fluorosuflonyl) imide (LiFSI) and beta-fluorinated sulfone (TFPMS) was designed to enable very stable long-term cycling of high-voltage lithium-ion batteries. Compared to other fluorinated solvents such as alpha-fluorinated sulfone (FMES) and fluorinated carbonate (FEMC), which are prone to reduction on the graphite anode, the LiFSI-TFPMS system displayed outstanding compatibility with graphite. While regular carbonate and sulfone from the LiFSI electrolyte system are compatible with the graphite anode, their high solvating power not only induces severe corrosion on the aluminum cathode current collector at high voltage, but also renders a low aggregation level at a normal salt concentration (about 1.0 M), resulting in the formation of an unstable solid-electrolyte interphase (SEI) on the graphite anode. Owing to the low solvating power of TFPMS, the aggregation level of the LiFSI-TFPMS system is relatively high even at normal salt concentration, which not only facilitates the formation of a robust SEI by the sacrificial decomposition of LiFSI, but also suppresses the aluminum corrosion of the LiFSI electrolyte system at high voltage. Together with the high intrinsic anodic stability of TFPMS, the superior cycling performance of graphite parallel to LiNi 0.6 Co 0.2 Mn 0.2 O 2 cells was achieved by employing the non-flammable LiFSI-TFPMS single-solvent electrolyte system.

25 ENERGY STORAGE↗