Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Tenth-order lepton anomalous magnetic moment: Second-order vertex containing two vacuum polarization subdiagrams, one within the other

This paper reports the tenth-order QED contribution to the g-2 of electron and muon from two gauge-invariant sets: Set I(g) and Set I(h). In the case of electron g-2, Set I(g) consists of nine Feynman diagrams which have a fourth-order vacuum-polarization loop containing another fourth-order vacuum-polarization loop. Set I(h) consists of 30 Feynman diagrams which have a proper sixth-order vacuum-polarization loop containing a second-order vacuum-polarization loop. The results of numerical integration, including mass-dependent terms containing one closed loop of muon, are 0.028 597 (4) ({alpha}/{pi}){sup 5} for Set I(g) and 0.001 685 (13) ({alpha}/{pi}){sup 5} for Set I(h), respectively. We also report the contributions of Set I(g) and Set I(h) to the muon anomaly. Diagrams included are those containing electron, muon, and tau-lepton loops. Their sums are 2.640 9 (4)({alpha}/{pi}){sup 5} and -0.564 8 (11)({alpha}/{pi}){sup 5}, respectively. The sum of contributions of Sets I(g) and I(h) containing only electron loops are in fair agreement with the recently obtained asymptotic analytic results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon magnetic moment and vacuum magnetization in an asymptotically large magnetic field

We consider the effect of the photon radiative correction on the vacuum energy in a superstrong magnetic field. The notion of a photon anomalous magnetic moment is analyzed and its connection with the quasiparticle character of the electromagnetic radiation is established. In the infrared domain the magnetic moment turns out to be a vector with two orthogonal components in correspondence with the cylindrical symmetry imposed by the external field. The possibility of defining such quantity in the high energy limit is studied as well. Its existence suggests that the electromagnetic radiation is a source of magnetization to the whole vacuum and thus its electron-positron zero-point energy is slightly modified. The corresponding contribution to the vacuum magnetization density is determined by considering the individual contribution of each vacuum polarization eigenmode in the Euler-Heisenberg Lagrangian. A paramagnetic response is found in one of them, whereas the remaining ones are diamagnetic. Additional issues concerning the transverse pressures are analyzed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extended Green-Liouville asymptotics and vacuum polarization for lukewarm black holes

We consider a quantum field on a lukewarm black hole spacetime. We introduce a new uniform approximation to the radial equation, constructed using an extension of Green-Liouville asymptotics. We then use this new approximation to construct the renormalized vacuum polarization in the Hartle-Hawking vacuum. Previous calculations of the vacuum polarization rely on the WKB approximation to the solutions of the radial equation; however, the nonuniformity of the WKB approximations obscures the results of these calculations near both horizons. The use of our new approximation eliminates these obscurities, enabling us to obtain explicitly finite and easily calculable values of the vacuum polarization on the two horizons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Frontiers in the Application of RF Vacuum Electronics

The application of radio frequency (RF) vacuum electronics for the betterment of the human condition began soon after the invention of the first vacuum tubes in the 1920s and has not stopped since. Today, microwave vacuum devices are powering important applications in health treatment, material and biological science, wireless communication-terrestrial and space, Earth environment remote sensing, and the promise of safe, reliable, and inexhaustible energy. This article highlights some of the exciting application frontiers of vacuum electronics.

42 ENGINEERING↗

Vacuum-evaporated ferroelectric films and heterostructures of vinylidene fluoride/trifluoroethylene copolymer

The potential of the vacuum method for preparing ferroelectric films and photonic heterostructures from organic materials is studied. Vacuum-evaporated films of fluoropolymers and heterostructures on their basis are obtained and their ferroelectric and spectral properties are studied. In particular, homogeneous films of the well-known piezoelectric polymer polyvinylidene fluoride and ferroelectric material vinylidene fluoride/trifluoroethylene copolymer (P(VDF/TFE)) are produced. Experimental studies of vacuum-evaporated P(VDF/TFE) films confirmed their ferroelectric properties. The heterostructures composed of alternating layers of P(VDF/TFE) copolymer molecules and azodye molecules are fabricated by vacuum evaporation. Owing to the controlled layer thickness and a significant difference in the refractive indices of the P(VDF/TFE) copolymer and azodyes, these heterostructures exhibit properties of photonic crystals. This finding is confirmed by the occurrence of a photonic band in the absorption spectra of the heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Study of the Residual Gas Composition in the Vacuum System of the Cyclotron of the Ioffe Physical Technical Institute

Mass spectra of residual gas molecules in vacuum system of the cyclotron of the Ioffe Physical Technical Institute (St. Petersburg) were obtained under various experimental conditions using a compact FT-200 time-of-flight mass spectrometer designed and manufactured at the institute. The measurements were performed in the vacuum chamber of cyclotron and in a terminal part of the ion guiding channel near the sample irradiation chamber. It is established that main contributions to residual gas composition in the cyclotron vacuum chamber are related to molecules of the vacuum oil (up to 82 vol %) and water molecules (up to 15–17 vol %), Water molecules also account for the main contribution (up to 63 vol %) to residual gas composition in the terminal part of the ion guiding channel near the sample irradiation chamber with a polymer film. The obtained data provide a basis for upgrade of the cyclotron complex of the Ioffe Physical Technical Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of RFQ vacuum system for HINS tests at MDB

The arrangement of RFQ vacuum system is briefly described. The projections of the vacuum level using standard out-gassing rates for the RFQ major components are compared with measurements. The permeation of water through the Viton O-rings of the LCW manifold inside the RFQ vacuum vessel is analyzed and compared with RGA data. A model where the out-gassing water from the vanes inner surfaces affects seriously RFQ operation is devised and compared with RFQ performance. The rate of a hydrogen gas spill from the LEBT into the RFQ vacuum space is also projected. Suggestions to correct and improve RFQ operation are presented.

43 PARTICLE ACCELERATORS↗

Spin Sum Rule of the Nucleon in the QCD Instanton Vacuum

We briefly review some essential aspects of the QCD instanton vacuum in relation to the quantum breaking of conformal symmetry, the spontaneous breaking of chiral symmetry, and the axial U(1) anomaly. The anomaly causes the intrinsic nucleon spin to transmute to the vacuum topological charge by quantum tunneling. We use Ji′s invariant spin decomposition to discuss the spin budget of the nucleon as a quark–diquark state in the QCD instanton vacuum. A measure of the intrinsic quark spin of the nucleon is a measure of the quenched topological susceptibility of the QCD instanton vacuum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modernization of NASA Johnson Space Center's Chamber A to Support Cryogenic Vacuum Optical Testing of the James Webb Space Telescope (JWST)

Final document is attached. NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the "Great Observatories", scheduled for launch in 2021. NASA is directly responsible for the integration and test (I&T) program that culminated in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describes the upgrades to the Chamber A facility: Thermal Shrouds, Helium Refrigeration, Liquid Nitrogen System, High Vacuum System, Clean Airflow System, and Utilities.

Thermal vacuum testing↗

Dry Preform Stitching Using Temporary Vacuum Consolidation

Stitched composites (composite parts stitched in a dry preform state that are infused with resin and cured to a final shape) offer a variety of benefits for modern aircraft structures. In this document one means of stitching dry fabric preforms in a state of temporary vacuum consolidation is discussed. This vacuum consolidation allows for the completion of stitching procedures while the dry preform thickness is temporarily reduced to a thickness reflective of its final cured thickness. Here, a temporary vacuum consolidation process enabling stitching of preforms of unconsolidated nominal thickness greater than the maximum allowable stitching thickness for the Integrated Structural Assembly of Advanced Composite (ISAAC) system is explored as a use case for such processes. Temporary vacuum consolidation processes may lead to simplified manufacturing processes or desirable composite material properties in the future.

Stitched Composites↗

Computer Controlled High Vacuum Gas Purification and Analysis Line

Light stable isotope work requires the handling of gasses such a way that does not alter isotopic composition. To do this, there are a large number of analytical and experimental procedures which involve the use of a vacuum line, numerous “egg timers” and a human hand on a valve. Unfortunately, the human hand is inconsistent and inadvertent small, and commonly large, differences in timing can have a measurable effect on outcomes. We have constructed a computer controlled high-vacuum line to be used as an expandable platform for future experimental and analytical procedures. The vacuum line consists of an electropolished 316 stainless steel system of cryogenic u-traps partitioned by pneumatic valves. The code to operate the line has been developed using the LabView platform and will allow for automated timing, consistent valve opening speed and unattended operation of long analytical procedures. The aim of this project is to address a need in the light stable isotope laboratory for a general-purpose vacuum line for handling and manipulation of gasses. When combined with existing instrumentation it allows for a significant expansion of current analytical capabilities. The system allows for better handling of standards, gas conversion techniques and gas sample collection for interlaboratory comparisons. The basic structure of the line, automation hardware and software were chosen and designed to provide a base for future expansion of the system to incorporate new automated analytical techniques as laboratory instrumentation and analytical needs expand.

High vacuum↗

In-Space Laser Forming Simulated Under Thermal Vacuum (TVAC) Conditions

NASA Marshall Space Flight Center is investigating laser forming under thermal vacuum conditions representative of the space environment through a partnership with the DARPA NOM4D program. The thermal gradient mechanism (TGM) is used to bend a metal sheet towards the laser optics. Laser equipment and process parameters are being optimized for thermal vacuum conditions. Such conditions are representative of the extreme cold and hot temperatures and high vacuum that exist on orbit or on the lunar surface. in situ photogrammetry and thermography assess the bend/counterbend and elucidate the TGM in thermal vacuum. Structured light scanning and metallography after bending reveal the macroscopic and microscopic structure after TGM.

thermal vacuum↗

Design of the EBIS vacuum system

At Brookhaven National Laboratory the Electron Beam Ion Source (EBIS) is presently being commissioned. The EBIS will be a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC). The new preinjector has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium. The background pressure in the ionization region of the EBIS required to be low enough that it does not produce a significant number of ions from background gas. The pressure in the regions of the electron gun and electron collector can be higher than in the ionization region provided there is efficient vacuum separation between the sections. For injection the ions must be accelerated to 100KV by pulsing the EBIS platform. All associated equipment including the vacuum equipment on the platform is at a 100KV potential. The vacuum system design and the vacuum controls for the EBIS platform and transport system will be presented as well as the interface with the Booster Ring which has a pressure 10-11 Torr.

43 PARTICLE ACCELERATORS↗

Quantum Vacuum Structure and Cosmology

Contemporary physics faces three great riddles that lie at the intersection of quantum theory, particle physics and cosmology. They are: (1) The expansion of the universe is accelerating - an extra factor of two appears in the size; (2) Zero-point fluctuations do not gravitate - a matter of 120 orders of magnitude; and (3) The 'True' quantum vacuum state does not gravitate. The latter two are explicitly problems related to the interpretation and the physical role and relation of the quantum vacuum with and in general relativity. Their resolution may require a major advance in our formulation and understanding of a common unified approach to quantum physics and gravity. To achieve this goal we must develop an experimental basis and much of the discussion we present is devoted to this task. In the following, we examine the observations and the theory contributing to the current framework comprising these riddles. We consider an interpretation of the first riddle within the context of the universe's quantum vacuum state, and propose an experimental concept to probe the vacuum state of the universe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The evolution of ion charge states in cathodic vacuum arc plasmas: a review

Cathodic vacuum arc plasmas are known to contain multiply charged ions. 20 years after “Pressure Ionization: its role in metal vapour vacuum arc plasmas and ion sources” appeared in vol. 1 of Plasma Sources Science and Technology, it is a great opportunity to re-visit the issue of pressure ionization, a non-ideal plasma effect, and put it in perspective to the many other factors that influence observable charge state distributions, such as the role of the cathode material, the path in the density-temperature phase diagram, the “noise” in vacuum arc plasma as described by a fractal model approach, the effects of external magnetic fields and charge exchange collisions with neutrals. A much more complex image of the vacuum arc plasma emerges putting decades of experimentation and modeling in perspective.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding initiation and termination events in the primary amine-initiated polymerization of NCAs by high-vacuum techniques

High-vacuum polymerization of -amino acid-N-carboxyanhydrides (NCAs) affords polymers with controlled molecular weights and narrow polydispersities, however a comprehensive study of the end-group composition of the resulting polypeptides has not yet been performed. This reveals crucial information, as the end-groups are indicative of both the polymerization mechanism (i.e., initiation event) as well as the termination pathways. To this end, poly(O-benzyl-L-tyrosine) initiated by 1,6-diaminohexane was synthesized and subsequently characterized by MALDI-TOF MS, NALDI -TOF MS and 13C NMR spectroscopy to ascertain the end-group structure. Polymers were prepared by both high vacuum and glove box techniques in DMF/THF. Preparation of poly(O-benzyl-L-tyrosine) by high vacuum techniques yielded a polymer initiated exclusively by the normal amine mechanism, and termination by reaction with DMF was observed. In contrast, polymers prepared in the glove box were initiated by the normal amine and activated monomer mechanisms, and several termination products are evident. To our knowledge, this is the first rigorous and comparative analysis of the end-group structure, and it demonstrates the advantage of high vacuum techniques for polymerization of NCAs for the preparation of well-defined polypeptides with end-group fidelity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum stability bounds on Higgs coupling deviations in the absence of new bosons

We analyze the constraints imposed by Higgs vacuum stability on models with new fermions beyond the Standard Model. We focus on the phenomenology of Higgs couplings accessible at the Large Hadron Collider. New fermions that affect Higgs couplings lead to vacuum instability of the Higgs potential. Above the scale of vacuum instability, bosonic states must stabilize the potential, implying a cut-off to the pure fermion model. Conservatively tuning the models to produce the maximal cut-off for a given Higgs coupling effect, we show that observing a deviation in the Htt, H-diphoton, or H-digluon coupling, larger than 20%, would require that new bosons exist in order to stabilize the Higgs potential below about 100 TeV. For generic parameter configurations, and unless the new fermions are made as light as they can possibly be given current experimental constraints, observing a 10% deviation in any of these couplings would suggest an instability cut-off below 10-100 TeV. Similarly, if new bosons are absent up to a high scale, then a deviation in the Hbb or Hττ coupling, larger than about 20%, should be accompanied by a sizable deviation in the Zbb or Zττ couplings that can be conclusively tested with electroweak precision measurements at planned lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Global electroweak symmetric vacuum

Although the Higgs potential in the Standard Model (SM) contains only a simple electroweak symmetry breaking vacuum in the small field region, additional metastable or global vacua could exist in models beyond the SM. In this paper, we study one intriguing scenario with an additional electroweak symmetric vacuum that could be the global one. For the thermal universe ending at the current metastable vacuum, the electroweak symmetry should stay non-restored at high temperatures. We realize the scenario in a model with Higgs-portal couplings to SM singlet scalars with approximately global O(N) symmetries with a large N. For a large portion of model parameter space, both the quantum and thermal tunneling rates are suppressed such that our current metastable vacuum is long-lived enough. Our scenario predicts order-one changes for the Higgs self-couplings and a large contribution to the signal of the off-shell Higgs invisible decay. It can be partly probed at the LHC Run 3 and well tested at the high luminosity LHC. We also discuss the subcritical (anti-de Sitter) bubbles from the thermal tunneling that could have a large population and interesting cosmological implications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗