Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle delays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Radiation response issues for infrared detectors

Researchers describe the most important radiation response issues for infrared detectors. In general, the two key degradation mechanisms in infrared detectors are the noise produced by exposure to a flux of ionizing particles (e.g.; trapped electronics and protons, debris gammas and electrons, radioactive decay of neutron-activated materials) and permanent damage produced by exposure to total dose. Total-dose-induced damage is most often the result of charge trapping in insulators or at interfaces. Exposure to short pulses of ionization (e.g.; prompt x rays or gammas, delayed gammas) will cause detector upset. However, this upset is not important to a sensor unless the recovery time is too long. A few detector technologies are vulnerable to neutron-induced displacement damage, but fortunately most are not. Researchers compare the responses of the new technologies with those of the mainstream technologies of PV HgCdTe and IBC Si:As. One important reason for this comparison is to note where some of the newer technologies have the potential to provide significantly improved radiation hardness compared with that of the mainstream technologies, and thus to provide greater motivation for the pursuit of these technologies.

Kalma, Arne H.↗

AGR-5/6/7 Irradiation Test Final As-run Report

This document presents the as-run analysis of the Advanced Gas Reactor (AGR)-5/6/7 irradiation experiment. AGR-5/6/7 is the last of a series of experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory in support of the development and qualification of tri-structural isotropic low-enriched fuel for use in high-temperature gas-cooled reactors. The test train contained five separate capsules that were independently controlled and monitored. Each capsule contained multiple 24.91-mm-long and 12.25-mm-dimeter compacts filled with low-enriched uranium carbide/oxide tri-structural isotropic fuel particles. The objectives of the AGR-5/6/7 experiment were to: • Irradiate reference-design fuel particles to support fuel qualification. • Establish operating margins for the fuel, beyond normal operating conditions. • Provide irradiated-fuel performance data and irradiated-fuel samples for post-irradiation examination and safety testing. The primary objective of the AGR-5/6 test (Capsules 1, 2, 4, and 5) was to verify the successful performance of the reference-design fuel under normal operating conditions. The AGR-7 test (Capsule 3) was designed to explore fuel performance at higher temperatures. Its primary objective was to demonstrate the capability of the fuel to withstand conditions beyond normal operating conditions, in support of plant design and licensing. AGR-5/6/7 will also provide irradiated-fuel performance data based on the fission gas release from particles during irradiation. To achieve the test objectives, the AGR-5/6/7 experiment was irradiated in the northeast flux trap of the ATR with a planned duration of 500 effective full-power days. The northeast flux trap was selected because its larger diameter provided greater flexibility for test-train design compared to the Large B positions used for the AGR-1 and AGR-2 irradiations, significantly enhancing test capabilities for the combined irradiation campaigns. Due to delays in the ATR schedule, the AGR-5/6/7 irradiation was significantly shorter than the originally planned 13-cycle schedule. Irradiation began on February 16, 2018 and ended on July 22, 2020, spanning nine ATR cycles (162B–168A) over two and a half years. Thus, the AGR-5/6/7 fuel compacts were irradiated for a total of approximately 360.9 effective full-power days. Final burnup values, on a per-compact basis, ranged from 5.66 to 15.26% fissions per initial heavy metal atom, while fast fluence values ranged from 1.62 to 5.55 × 1025 n/m2 (E >0.18 MeV). Time-averaged volume-averaged fuel temperatures on a capsule basis at the end of irradiation ranged from 756°C in Capsule 5 to 1313°C in Capsule 3 excluding days with significantly lower temperature during the two short powered axial locator mechanism cycles, 163A and 167A. By the end of irradiation, 48 out of 54 installed thermocouples had failed (the bottom three capsules lost all thermocouples). During the first five cycles (162B – 165A), the fission-gas isotope release-rate-to-birthrate (R/B) ratios were stable in the 10-8–10-6 range, and no in-pile particle failures were observed based on the gross gamma counts. During this time, the high exposed kernel fraction and high fuel particle temperatures in Capsule 1 led to a maximum R/B value of around 2 ? 10-6 for Kr-85m. The fission gas release in all capsules started to increase from the second half of Cycle 166A, when a large number of in-pile particle failures occurred in Capsule 1 and a gas line problem in this capsule caused fission gas leakage at various degrees into the other four capsules. This gas line problem also prevented a fission gas release measurement for Capsule 1 during the last three cycles due to gas flow isolation. By the end of irradiation, it is estimated that approximately 15 particles failed in Capsule 3, which was considered possible because the experiment was designed to operate beyond the high-temperature gas-cooled reactor normal operating temperature range. A few hundred in-pile particle failures were estimated for Capsule 1 by the end of Cycle 166A, but the total number of failures is unknown due to the lack of fission gas release data in the later cycles. Additionally, four potential in-pile failures were identified for Capsule 2 during the last cycle, Cycle 168A. In contrast, no in-pile failures were identified in the top two capsules (4 and 5) based on the absence of the typical spikes in gross gamma counts and low failure estimates using the AGR-3/4 R/B per exposed kernel model.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Irradiation Test Final As-run Report

This document presents the as-run analysis of the Advanced Gas Reactor (AGR) 5/6/7 irradiation experiment. AGR-5/6/7 is the last of a series of experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of the development and qualification of tri-structural isotropic (TRISO) low enriched fuel for use in high-temperature gas-cooled reactors (HTGR). The test train contained five separate capsules that were independently controlled and monitored. Each capsule contained multiple 24.91-mm-long and 12.25-mm-dimeter compacts filled with low-enriched uranium carbide/oxide tri-structural isotropic fuel particles. The objectives of the AGR 5/6/7 experiment were to: 1. Irradiate reference-design fuel particles to support fuel qualification. 2. Establish operating margins for the fuel, beyond normal operating conditions. 3. Provide irradiated-fuel performance data and irradiated-fuel samples for post irradiation examination and safety testing. The primary objective of the AGR-5/6 test (Capsules 1, 2, 4, and 5) was to verify the successful performance of the reference-design fuel under normal operating conditions. The AGR-7 test (Capsule 3) was designed to explore fuel performance at higher temperatures. Its primary objective is to demonstrate the capability of the fuel to withstand conditions beyond normal operating conditions, in support of plant design and licensing. AGR 5/6/7 will also provide irradiated-fuel performance data based on the fission gas release from particles during irradiation. To achieve the test objectives, the AGR-5/6/7 experiment was irradiated in the northeast (NE) flux trap of the ATR with a planned duration of 500 effective full-power days (EFPDs). The NE flux trap was selected because its larger diameter provided greater flexibility for test-train design compared to the Large B positions used for the AGR-1 and AGR-2 irradiations, significantly enhancing test capabilities for the combined irradiation campaigns. Due to delays in the ATR schedule, the AGR-5/6/7 irradiation was significantly shorter than the originally planned 13-cycle schedule. Irradiation began on February 16, 2018 and ended on July 22, 2020, spanning nine ATR cycles (162B?168A) over two and a half years. Thus, the AGR-5/6/7 fuel compacts were irradiated for a total of approximately 360.9 EFPDs. Final burnup values, on a per-compact basis, ranged from 5.66% to 15.26% fissions per initial heavy metal atom, while fast fluence values ranged from 1.62 to 5.55 × 1025 n/m2 (E >0.18 MeV). Time-averaged volume-averaged fuel temperatures on a capsule basis at the end of irradiation ranged from 756°C in Capsule 5 to 1313°C in Capsule 3 excluding days with significantly lower temperature during the two short powered axial locator mechanism cycles, 163A and 167A. By the end of irradiation, 48 out of 54 installed thermocouples (TC) had failed (the bottom three capsules lost all TCs). During the first five cycles (162B ? 165A), fission-gas isotope release-rate-to-birthrate (R/B) ratios were stable in the 10-8?10-6 range, and no in-pile particle failures were observed based on the gross gamma counts. During this time, the high exposed kernel fraction and high fuel particle temperatures in Capsule 1 led to the maximum R/B value of around 2 ? 10-6 for Kr-85m. The fission gas release in all capsules started to increase from the second half of Cycle 166A, when a large number of in-pile particle failures occurred in Capsule 1 and a gas line problem in this capsule caused fission gas leakage at various degrees into the other four capsules. This gas line problem also prevented fission gas release measurement for Capsule 1 during the last three cycles due to gas flow isolation. By the end of irradiation, it is estimated that approximately 15 particle failures in Capsule 3, which was considered possible at the start of the irradiation, since the experiment was designed to operate beyond the high-temperature gas-cooled reactor (HTGR) normal operating temperature range. A few hundred in-pile particle failures were estimated for Capsule 1 by the end of Cycle 166A, but the total number of failures is unknown due to lack of fission gas release data in the later cycles. Additionally, four potential in-pile failures were identified for Capsule 2 during the last cycle, 168A. In contrast, no in-pile failures were identified in the top two capsules (4 and 5) based on absence of the typical spikes in gross gamma counts and low failure estimates using the AGR-3/4 R/B per exposed kernel model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dielectric surface discharges: Effects of combined low-energy and high-energy incident electrons

Dielectric surface discharges affected by the addition of high energy electrons at 5 pA/sq cm to a primary 20 keV, 10 nA/sq cm electron beam with the high energy broad spectrum particles coming from the beta decay of Strontium 90 are studied. Kapton exhibits significantly increased discharge strength, increased waiting time between discharges, and a decreased number of discharges per specimen before discharge cessation. Mylar exhibits similar but less pronounced effects, while Teflon is relatively unaffected. With Kapton and Mylar, the high energy electrons act in some way to delay the instant of discharge ignition so that more charge can be accumulated and hence released during discharge.

Balmain, K. G.↗

Dielectric surface discharges - Effects of combined low-energy and high-energy incident electrons

Dielectric surface discharges affected by the addition of high energy electrons at 5 pA/sq cm to a primary 20 keV, 10 nA/sq cm electron beam with the high energy broad spectrum particles coming from the beta decay of Strontium 90 are studied. Kapton exhibits significantly increased discharge strength, increased waiting time between discharges, and a decreased number of discharges per specimen before discharge cessation. Mylar exhibits similar but less pronounced effects, while Teflon is relatively unaffected. With Kapton and Mylar, the high energy electrons act in some way to delay the instant of discharge ignition so that more charge can be accumulated and hence released during discharge. Previously announced in STAR as N82-14222

Balmain, K. G.↗

Mars Ground Level Enhancements in the Context of the Solar Energetic Particle Clock

In this work we discuss the growing ensemble of solar particle events registered on the Martian surface, including their temporal appearance and solar sources. Solar energetic particle events from the surface of Mars have been observed starting soon after the August 2012 landing of the Radiation Assessment Detector onboard Curiosity. The Martian atmosphere prevents protons and heavy ions of up to 180 MeV/n kinetic energy from directly reaching the Martian surface. This cut-off is high enough to limit the number of solar energetic particle events measured on the surface to only 15 in ~12 ½ years. Yet we find in this analysis that Mars ground level enhancements follow the distinct SEP clock pattern as proton events observed at lower energies as reported in Posner, Richardson and Strauss (2024). Proton acceleration occurs predominantly near the solar surface, while transport to Mars incurs a delay in onset, and, as we show here, peak, that is a function of the longitudinal magnetic connection distance. between the foot point of solar wind magnetic field lines that intersect the Mars environment with the source longitude of the solar magnetic eruption. A distinct clustering of relative solar source locations at or near the Mars foot points at the Sun’s western limb is apparent, indicating lower flux thresholds from such preferred locations. Our findings have implications for astronaut safety at Mars.

Mars Ground Level Enhancements↗

Characterizing particle-like charge-migration dynamics with high-order harmonic sideband spectroscopy

Here, we introduce high-order harmonic sideband spectroscopy and show that it can be a robust probe of charge migration (CM) in a halogenated carbon-chain molecule. We simulate both the CM and high-order harmonic generation (HHG) dynamics using ab initio time-dependent density-functional theory. We find that CM dynamics initiated along the molecular backbone induces sidebands in the HHG spectrum driven by a delayed laser pulse that is polarized perpendicular to the molecular axis. Monitoring the spectrum as either the HHG laser frequency or the relative delay is scanned allows for the extraction of detailed information about the time-domain characteristics of the CM process.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study of few-electron backgrounds in the LUX-ZEPLIN detector

The LUX-ZEPLIN (LZ) experiment aims to detect rare interactions between dark matter particles and xenon. Although the detector is designed to be the most sensitive to GeV/𝑐 2 –TeV/𝑐 2 weakly interacting massive particles (WIMPs), it is also capable of measuring low-energy ionization signals down to a single electron that may be produced by scatters of sub-GeV/𝑐 2 dark matter. The major challenge in exploiting this sensitivity is to understand and suppress the ionization background in the few-electron regime. We report a characterization of the delayed electron backgrounds following energy depositions in the LZ detector under different detector conditions. In addition, we quantify the probability for photons to be emitted in coincidence with electron emission from the high voltage grids. We then demonstrate that spontaneous grid electron emission can be identified and rejected with a high efficiency using a coincident photon tag, which provides a tool to improve the sensitivity of future dark matter searches.

Akerib, D. S. [SLAC National Accelerator Laborator↗

Enhanced heavy oil recovery by low salinity polymer flood combined with microgel treatment

“Heavy oil resources account for a large portion of the total oil reserves around the world. The target heavy oil reservoir is located on Alaska’s North Slope (ANS). Advantages of low-salinity HPAM polymer (LSP) over high-salinity polymer (HSP) were demonstrated. LSP could recover more oil with 40% less polymer consumption. No additional oil was recovered by HSP after LSP flood. The first-ever polymer flood pilot on ANS showed remarkable success regarding water cut reduction, oil production increase, delayed breakthrough, and projected oil recovery improvement. Polymer alone was insufficient to achieve satisfactory recovery as the reservoirs were highly heterogeneous. Microgels could improve the effectiveness of polymer flood by reducing water cut and increasing oil recovery. Favorable working conditions were identified. Microgel transport behavior was studied using superpermeable sandpacks (27-221 darcies) with multiple pressure sensors. The particle-to-pore matching size ratio significantly impacted the effectiveness of the gels. A threshold differential pressure (ΔPth) and critical pressure gradient (∇Pcr) were required to push the gels to penetrate and propagate through the channels. The ΔPth and ∇Pcr revealed the underlying mechanisms of selective penetration/placement behavior of microgels in heterogeneous reservoirs. Diagrams were developed to estimate the maximum propagation distance of the gels in channels in conceptual field applications. Sandwich-like channel models and methodologies were developed to comprehensively evaluate the effectiveness of gel materials. Gel retention in the channels was quantified. Results also indicated that the retained gels were dehydrated. Fluid diversion and sweep improvement after gel treatments were evaluated by tracer tests”--Abstract, page iv.

Zhao, Yang↗

Data transmission by quantum matter wave modulation

Abstract Classical communication schemes exploiting wave modulation are the basis of our information era. Quantum information techniques with photons enable future secure data transfer in the dawn of decoding quantum computers. Here we demonstrate that also matter waves can be applied for secure data transfer. Our technique allows the transmission of a message by a quantum modulation of coherent electrons in a biprism interferometer. The data is encoded in the superposition state by a Wien filter introducing a longitudinal shift between separated matter wave packets. The transmission receiver is a delay line detector performing a dynamic contrast analysis of the fringe pattern. Our method relies on the Aharonov–Bohm effect but does not shift the phase. It is demonstrated that an eavesdropping attack will terminate the data transfer by disturbing the quantum state and introducing decoherence. Furthermore, we discuss the security limitations of the scheme due to the multi-particle aspect and propose the implementation of a key distribution protocol that can prevent active eavesdropping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

$$\alpha $$-event characterization and rejection in point-contact HPGe detectors

Abstract P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector’s response to $$\alpha $$ α particles incident on the sensitive passivated and p $$^+$$ + surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the Majorana Demonstrator experiment, a search for neutrinoless double-beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in $$^{76}$$ 76 Ge. $$\alpha $$ α decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $$\alpha $$ α identification, reliably identifying $$\alpha $$ α background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $$\alpha $$ α events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $$0\nu \beta \beta $$ 0 ν β β region of interest window by an order of magnitude in the Majorana Demonstrator and will be used in the upcoming LEGEND-200 experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Second Target Station High-Fidelity Target Activation Comparison

The development of the Second Target Station (STS) target system at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is well underway. The target system at STS consists of a rotating target disk that contains 21 segments of tungsten clad in tantalum clad in steel. A key aspect of the design of the target system is to account for the delayed heating and material damage caused by the delayed dose from decaying radionuclides. These radionuclides are a product of either spallation reactions or transmutation of the nuclei in the target system. These radionuclides build up in the target system components over the lifetime of the facility, and the radiation that is emitted can deposit energy in the components causing significant component heating and material damage. Monte Carlo N-Particle (MCNP) Version 6.2 transports the various particle species and calculates the spallation products and neutron fluxes throughout the target system. These spallation products and neutron fluxes along with the material definition of each component are relayed to the CINDER2008 transmutation code to calculate the radionuclide inventories and the corresponding decay gamma emission spectra. MCNP6.2 coupled with CINDER2008 is the computational method-of-choice for the analysis discussed in the following sections of this report. The analysis focuses on validating major assumptions in calculating the radionuclide inventory in the STS target system: all of the target segments are fresh, unirradiated material when the protons are incident on the segment, the average of the 21 segments of the target is sufficient to represent a single segment, and that averaging the proton pulse structure over time does not significantly affect the radionuclide inventory. The position-averaged, high-fidelity, and single-tally computational methods are used to validate the assumptions and provide a point of comparison to evaluate how the assumptions impact the radionuclide inventories. A more detailed explanation of the three computational methods is provided in Section 2. The position-averaged and single-tally methods are less computationally expensive when compared with the high-fidelity method where 54,000 individual calculations are needed to calculate 1 hr of STS operation. Section 3 details the comparison of the three methods to show that the assumptions made in the position-averaged method do not significantly impact the radionuclide inventory after 1 hr of operation. The discussions and results in this report are for 1 hr of operation. Due to the computational cost associated with calculating the transmutation and activation using the high-fidelity method, only 1 hr of operation has been calculated. The discrepancies observed after 1 hr of operation are not extrapolated out to longer operational times, and this report does not address how the discrepancies between the computational methods may manifest for longer operational periods.

43 PARTICLE ACCELERATORS↗

Atmospheric Multiple Scattering Effects on GLAS Altimetry: Analysis of Expected Errors in Antarctic Altitude Measurements - Part 2

The altimetry bias in GLAS (Geoscience Laser Altimeter System) or other laser altimeters resulting from atmospheric multiple scattering is studied in relationship to current knowledge of cloud properties over the Antarctic Plateau. Estimates of seasonal and interannual changes in the bias are presented. Results show the bias in altitude from multiple scattering in clouds would be a significant error source without correction. The selective use of low optical depth clouds or cloudfree observations, as well as improved analysis of the return pulse such as by the Gaussian method used here, are necessary to minimize the surface altitude errors. The magnitude of the bias is affected by variations in cloud height, cloud effective particle size and optical depth. Interannual variations in these properties as well as in cloud cover fraction could lead to significant year-to-year variations in the altitude bias. Although cloud-free observations reduce biases in surface elevation measurements from space, over Antarctica these may often include near-surface blowing snow, also a source of scattering-induced delay. With careful selection and analysis of data, laser altimetry specifications can be met.

Mahesh, Ashwin↗

Tagging Cosmic Ray Background in the Icarus Detector

ICARUS T-600 will be the Far Detector of the upcoming SBN program, for which it will leverage a ∼ 1ns response and a high resolution for neutrino event reconstruction. ICARUS will respond to the challenge of the cosmic flux at the surface thanks to its Cosmic Ray Tagging (CRT) system. The work conducted during the Summer Students at Fermilab program contributed to the calibration activities that are ongoing in view of the second physics run in late 2022: the timing of CRT and PMT signals was analysed, highlighting the need for corrections to the PMTs. The timing delay for the global trigger signal for a section of the side CRT. The possibility of calibrating the light yield of the side CRTs with run data was finally explored.

47 OTHER INSTRUMENTATION↗

AstroPix4 — a novel HV-CMOS sensor developed for space based experiments

For the proposed space based gamma-ray observatory All-sky Medium-Energy Gamma-ray Observatory eXplorer (AMEGO-X), a silicon tracker based on a novel High Voltage-CMOS (HV-CMOS) sensor called AstroPix, is currently being developed. Preliminary measurements with the first full reticle prototype AstroPix3 show that the power target of 1.5 mW/cm 2 can currently not be reached due to the digital consumption of 3.08 mW/cm 2 , while the analog power consumption of 1.04 mW/cm 2 and a break down voltage of over 350 V look promising. Based on these results, the design changes in AstroPix4, submitted in May 2023, are presented, containing changes to the time stamp generation and readout architecture. A digital power consumption below 0.25 mW/cm 2 is expected by removing the fast 200 MHz clock used to measure the time-over-threshold (ToT) and an LVDS receiver. A maximum resolution of 3.125 ns for time-of-arrival (ToA) and ToT is reached by adding per-pixel Flash-Time-to-Digital Converter (TDCs) controlled by a global delay-locked loop (DLL).

47 OTHER INSTRUMENTATION↗

Apparent 𝑤 <−1 and a Lower 𝑆 8 from Dark Axion and Dark Baryons Interactions

We show that a simple coupling between dark energy and dark matter can simultaneously address two distinct hints at new physics coming from cosmological observations. The first is the recent evidence from the DESI project and supernovae observations that the dark energy equation of state w is evolving over cosmic time from an earlier value that is <-1 to a present-day value >-1. The second observation is the so-called S8 tension, describing the suppression of the growth of matter overdensities compared to that expected in the ΛCDM model. Here, we propose a stable, technically natural particle physics implementation of this idea, in which dark matter consists of dark baryons in a strongly coupled hidden sector, and the dark energy field is the associated dark axion. The time variation of the dark matter mass results in an effective dark energy equation of state that exhibits a phantom crossing behavior consistent with recent results. It also results in a slight delay in matter-radiation equality, which suppresses the overall growth of density perturbations.

Axions↗