Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Data acquisition system for the Baikal-GVD neutrino telescope

The objective of the Baikal-GVD project is the construction of a km{sup 3}-scale neutrino telescope in Lake Baikal. The Gigaton Volume Detector consists of a large three-dimensional array of photo-multiplier tubes. The first GVD-cluster has been deployed and commissioned in April 2015. The data acquisition system (DAQ) of the detector takes care of the digitization of the photo-multiplier tube signals, data transmission, filtering and storage. The design and the implementation of the data acquisition system are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Acquisition Strategy for the Idaho National Laboratory Remote-Handled Low-Level Waste Disposition Project

This document describes the design-build acquisition strategy that will be applied to the Remote Handled LLW Disposal Project. The design-build delivery method will be tailored, as appropriate, to integrate the requirements of Department of Energy (DOE) Order 413.3B, 'Program and Project Management for the Acquisition of Capital Assets,' with the DOE budget formulation process and the safety requirements of DOE-STD-1189, 'Integration of Safety into the Design Process.'

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A hybrid data acquisition system for magnetic measurements of accelerator magnets

A hybrid data acquisition system was developed for magnetic measurement of superconducting accelerator magnets at LBNL. It consists of a National Instruments dynamic signal acquisition (DSA) card and two Metrolab fast digital integrator (FDI) cards. The DSA card records the induced voltage signals from the rotating probe while the FDI cards records the flux increment integrated over a certain angular step. This allows the comparison of the measurements performed with two cards. In this note, the setup and test of the system is summarized. With a probe rotating at a speed of 0.5 Hz, the multipole coefficients of two magnets were measured with the hybrid system. The coefficients from the DSA and FDI cards agree with each other, indicating that the numerical integration of the raw voltage acquired by the DSA card is comparable to the performance of the FDI card in the current measurement setup.

43 PARTICLE ACCELERATORS↗

Continued Data Acquisition Development

This task focused on improving techniques for integrating data acquisition of secondary particles correlated in time with detected cosmic-ray muons. Scintillation detectors with Pulse Shape Discrimination (PSD) capability show the most promise as a detector technology based on work in FY13. Typically PSD parameters are determined prior to an experiment and the results are based on these parameters. By saving data in list mode, including the fully digitized waveform, any experiment can effectively be replayed to adjust PSD and other parameters for the best data capture. List mode requires time synchronization of two independent data acquisitions (DAQ) systems: the muon tracker and the particle detector system. Techniques to synchronize these systems were studied. Two basic techniques were identified: real time mode and sequential mode. Real time mode is the preferred system but has proven to be a significant challenge since two FPGA systems with different clocking parameters must be synchronized. Sequential processing is expected to work with virtually any DAQ but requires more post processing to extract the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Trek Re-configurable Processor for Data Acquisition (RPDA)

This report summarizes technical progress achieved during the cooperative research agreement between Honeywell and U.S. Department of Energy to develop a high-temperature Re-configurable Processor for Data Acquisition (RPDA). The RPDA development has incorporated multiple high-temperature (225C) electronic components within a compact co-fired ceramic Multi-Chip-Module (MCM) package. This assembly is suitable for use in down-hole oil and gas applications. The RPDA module is programmable to support a wide range of functionality. Specifically this project has demonstrated functional integrity of the RPDA package and internal components, as well as functional integrity of the RPDA configured to operate as a Multi-Channel Data Acquisition Controller. This report reviews the design considerations, electrical hardware design, MCM package design, considerations for manufacturing assembly, test and screening, and results from prototype assembly and characterization testing.

02 PETROLEUM↗

Rotary Percussive Sample Acquisition Tool

As part of a potential Mars Sample Return campaign NASA is studying a sample caching mission to Mars, with a possible 2018 launch opportunity. As such, a Sample Acquisition Tool (SAT) has been developed in support of the Integrated Mars Sample Acquisition and Handling (IMSAH) architecture as it relates to the proposed Mars Sample Return (MSR) campaign. The tool allows for core generation and capture directly into a sample tube. In doing so, the sample tube becomes the fundamental handling element within the IMSAH sample chain reducing the risk associated with sample contamination as well as the need to handle a sample of unknown geometry. The tool's functionality was verified utilizing a proposed rock test suite that encompasses a series of rock types that have been utilized in the past to qualify Martian surface sampling hardware. The corresponding results have shown the tool can effectively generate, fracture, and capture rock cores while maintaining torque margins of no less than 50% with an average power consumption of no greater than 90W and a tool mass of less than 6kg.

Sample Acquisition and Caching (SAC)↗

Detector Control and Data Acquisition for the Wide-Field Infrared Survey Telescope (WFIRST) with a Custom ASIC

The Wide-Field Infrared Survey Telescope (WFIRST) will have the largest near-IR focal plane ever flown by NASA, a total of 18 4K x 4K devices. The project has adopted a system-level approach to detector control and data acquisition where 1) control and processing intelligence is pushed into components closer to the detector to maximize signal integrity, 2) functions are performed at the highest allowable temperatures, and 3) the electronics are designed to ensure that the intrinsic detector noise is the limiting factor for system performance. For WFIRST, the detector arrays operate at 90 to 100 K, the detector control and data acquisition functions are performed by a custom ASIC at 150 to 180 K, and the main data processing electronics are at the ambient temperature of the spacecraft, notionally approx.300 K. The new ASIC is the main interface between the cryogenic detectors and the warm instrument electronics. Its single-chip design provides basic clocking for most types of hybrid detectors with CMOS ROICs. It includes a flexible but simple-to-program sequencer, with the option of microprocessor control for more elaborate readout schemes that may be data-dependent. All analog biases, digital clocks, and analog-to-digital conversion functions are incorporated and are connected to the nearby detectors with a short cable that can provide thermal isolation. The interface to the warm electronics is simple and robust through multiple LVDS channels. It also includes features that support parallel operation of multiple ASICs to control detectors that may have more capability or requirements than can be supported by a single chip.

data acquisition↗

Upgrading the 14x22 Data Acquisition System (DAS)

The 14-by 22-Foot Subsonic Tunnel recently completed development and installation of a new Data Acquisition System for use in the tunnel and in the Rotor Test Cell (RTC). Planning and development of this new system has been ongoing for several years, and installation was performed over this past year. This effort also required an upgrade of the facility infrastructure to support the upgraded power and cooling requirements. This presentation summarizes the new data acquisition system, improved capabilities, challenges of installation, and proposed future enhancements to the system.

wind tunnel↗

Information Acquisition & Processing in Scanning Probe Microscopy

Much of the imaging and spectroscopy capabilities of the existing 20,000+ scanning probe microscopes worldwide relies on specialized data processing that links the microsecond (and sometimes faster) time scale of cantilever motion to the millisecond (and sometimes slower) time scale of image acquisition and feedback. In most SPMs, the cantilever is excited to oscillate sinusoidally and the time-averaged amplitude and/or phase are used as imaging or control signals. Traditionally, the step of converting the rapid motion of the cantilever into an amplitude or phase is performed by phase sensitive homodyne or phase-locked loop detection. The emergence of fast configurable data processing electronics in last several years has allowed the development of non-sinusoidal data acquisition and processing methods. Here, we briefly review the principles and limitations of phase sensitive detectors and discuss some of the emergent technologies based on rapid spectroscopic measurements in frequency- and time domains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Telescope Using CMS PSI46 Pixels and the CAPTAN for Acquisition and Control over Gigabit Ethernet

The Electronic Systems Engineering department of the Computing Division at the Fermi National Accelerator Laboratory has assembled a pixel test beam telescope for high energy physics detector research and development. The telescope features CMS PSI46 readout chips and a data acquisition and control system known as the Compact And Programmable daTa Acquisition Node or CAPTAN. The CAPTAN is a flexible and powerful system that meets the readout and control demands of a variety of pixel and strip detectors for high energy physics applications. The CAPTAN functions in a gigabit Ethernet network, which facilitates the coordination of the multiple pixel planes of the telescope. Through the use of the CAPTAN hardware, a unified telescope system is attained encompassing both the CMS PSI46 pixel components and adevice under test. This paper discusses results from the telescope project including mechanical design, alignment procedure, and attainble precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Data Acquisition Graphical User Interface

Traditional radioxenon measurements have been done by ground based fixed systems, however in recent years there has been an increased need for systems capable of quick deployment or even complete mobility. Using the Pixie-4 data acquisition (DAQ) system can help reduce the electronics footprint of both current systems, like the radioxenon Radionuclide Laboratory 16 (RL-16) and the Swedish Automatic Unit for Noble Gas Acquisition (SAUNA), as well as future systems. Pacific Northwest National Laboratory (PNNL) has developed a Linux based Nyx graphical user interface (GUI) for Pixie-4 cards. The Nyx software can be installed on various Linux platforms and is written in C++. This software offers a rich user interface for configuring and operating the Pixie4 card and PNNL designed high voltage (HV) cards. Nyx allows one to quickly get a nuclear detector operational by maintaining the core diagnostic features built into the Pixie-4 cards. First, Nyx maintains the multitude of adjustable parameters accessible in the Pixie-4 cards, which allows one to customize settings to take full advantage of a particular detector. Nyx also maintains an oscilloscope feature which is extremely useful to optimize settings and to verify proper detector behavior and is often the first feature used in Nyx during detector setup. Finally, Nyx allows the user to collect data in several formats including full pulse shapes to basic histograms. Overall, it is the corner stone for the transition of beta-gamma systems to a state-of-the-art digitizing DAQ.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Ribavirin targets sugar transporter 6 to suppress acquisition and transmission of rice stripe tenuivirus by its vector Laodelphax striatellus

Abstract BACKGROUND Rice stripe tenuivirus (RSV) is one of the most destructive pathogens of rice and other cereal crops. The virus is transmitted by the small brown planthopper (SBPH, Laodelphax striatellus ) in a circulative‐propagative manner. Thus, blocking transmission by the insect vector would provide an effective strategy to prevent epidemic outbreaks of the disease. RESULTS In this study, we explored the effect of ribavirin on acquisition and transmission of the virus by specifically inhibiting the expression of sugar transporter 6 (LsSt‐6), which was recently reported as a key vector component for RSV transmission. Ribavirin at the highest concentration tested (250 μmol L ‐1 ) significantly reduced RSV acquisition and transmission efficiency by SBPHs through inhibiting LsSt‐6 messenger RNA (mRNA) level. Survival of the model insect Spodoptera frugiperda cell line (Sf9) was 95.0 ± 2.2 and 85.6 ± 2.1% after exposure to 250 μmol L ‐1 ribavirin or 8‐azaguanine, respectively. Further study confirmed that 250 μmol L ‐1 ribavirin also significantly reduced LsSt‐6 mRNA and protein levels in Sf9 cells. However, 8‐azaguanine did not significantly inhibit viral infectivity and LsSt‐6 mRNA levels in SBPH or the Sf9 cell line. CONCLUSION This result provides evidence that ribavirin has the potential to disrupt LsSt‐6 expression but not others like viral RNAs to prevent acquiring RSV, which leads to less viral accumulation in SBPH tissues and thereby lower transmission efficiency. © 2020 Society of Chemical Industry

Hajano, Jamal‐U‐Ddin↗

Comparison of navigator-gated and breath-held image acquisition techniques for multi-echo quantitative dixon imaging of the liver in children and young adults

Purpose: Acquired over a breath hold, multi-echo Dixon (mDixon) magnetic resonance imaging (MRI) of the liver can be used to quantify proton density fat fraction (PDFF) and iron-related signal decay. However, young, obese, and co-morbid patients may have limited breath holding capacity and could benefit from a motion-robust mDixon acquisition. The purpose of this study was to compare hepatic PDFF and R2* values between navigator-gated and breath-held mDixon MRI acquisition techniques in children and young adults with suspected liver disease. Materials and methods: This retrospective study was institutional review board-approved with a waiver of informed consent. Patients who underwent liver MRI with breath-held and navigator-gated mDixon sequences between January 2017 and July 2018 were included. One reviewer, blinded to sequence, measured PDFF and R2* on four images from each sequence. Another blinded reviewer graded respiratory motion (5-point Likert scale). Pearson correlation (r), Lin’s concordance coefficients (r{sub c}), and Bland–Altman analyses were used to assess agreement between techniques. Frequency of clinically limiting motion (score ≥ 3) was compared with Fisher’s exact test. Results: Forty-two patients were included (15 female, 27 male; mean age: 15.7 ± 4.6 years). Mean PDFF and R2* were 16.6 ± 13.1% and 29.3 ± 4.7 s{sup −1} (breath-held) versus 17.0 ± 13.2% and 29.6 ± 5.2 s{sup −1} (navigator-gated). PDFF agreed almost perfectly between sequences (r{sub c} = 0.997, 95% CI 0.994–0.998; mean bias: 0.3%; 95% limits of agreement: − 2.4 to +1.7%), while R2* values correlated very strongly but with poor agreement (r = 0.837, r{sub c} = 0.832, 95% CI 0.716–0.910). Navigator-gated images exhibited significantly higher frequency of clinically limiting respiratory motion (88% vs. 48%, p = 0.0001). Conclusion: Despite greater respiratory motion artifact, a free-breathing navigator-gated mDixon sequence produces PDFF values with almost perfect agreement to a breath-held sequence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Root architectural plasticity optimizes nutrient acquisition in switchgrass under variable phosphorus forms

Aims Understanding the influence of different forms of phosphorus (P) over the different root traits and how those traits are related to increasing the efficiency of nutrient acquisition strategies. Methods Investigation of switchgrass (Panicum virgatum L.) root morphology responses to inorganic P (Pi) soluble (Potassium-P), insoluble (Aluminum-P), and organic P (Po) (Inositol Hexa-Phosphate, IHex-P) in rhizoboxes. Roots were traced over the root box and scanned using WinRhizoTM. The CRootbox model was employed to simulate root growth. Results Significant plasticity observed under IHex-P treatment, with a 46% increase in root branching, leading to a 74% rise in total root length and a 65% increase in root surface area compared to inorganic P forms. IHex-P resulted in a 73% higher root biomass than Aluminum-P and a 26% increase compared to Potassium-P. Most of the differences were attributed to the elongation of root branches. Conclusions Here, the study emphasizes the dynamic nature of switchgrass root architecture and morphology in response to varying P forms in the soil. The absence of Pi in the soil triggered increased plasticity in root traits, facilitating root access to Po and uptake of P. These findings offer valuable insights into the adaptive mechanisms of perennial plants, with significant implications for optimizing nutrient acquisition strategies in both agricultural and natural ecosystems.

Organic phosphorus↗

A Strategy Combining Higher Energy C-Trap Dissociation with Neutral Loss- and Product Ion-Based MS{sup n} Acquisition for Global Profiling and Structure Annotation of Fatty Acids Conjugates

Fatty acids conjugates (FACs) are ubiquitous but found in trace amounts in the natural world. They are composed of multiple unknown substructures and side chains. Thus, FACs are difficult to be analyzed by traditional mass spectrometric methods. In this study, an integrated strategy was developed to global profiling and targeted structure annotation of FACs in complex matrix by LTQ Orbitrap. Dicarboxylic acid conjugated bufotoxins (DACBs) in Venenum bufonis (VB) were used as model compounds. The new strategy (abbreviated as HPNA) combined higher-energy C-trap dissociation (HCD) with product ion- (PI), neutral loss- (NL) based MS{sup n} (n ≥ 3) acquisition in both positive-ion mode and negative-ion mode. Several advantages are presented. First, various side chains were found under HCD in negative-ion mode, which included both known and unknown side chains. Second, DACBs with multiple side chains were simultaneously detected in one run. Compared with traditional quadrupole-based mass method, it greatly increased analysis throughput. Third, the fragment ions of side chain and steroids substructure could be obtained by PI- and NL-based MS{sup n} acquisition, respectively, which greatly increased the accuracy of the structure annotation of DACBs. In all, 78 DACBs have been discovered, of which 68 were new compounds; 25 types of substructure formulas and seven dicarboxylic acid side chains were found, especially five new side chains, including two saturated dicarboxylic acids [(azelaic acid (C{sub 9}) and sebacic acid (C{sub 10})] and three unsaturated dicarboxylic acids (u-C{sub 8}, u-C{sub 9}, and u-C{sub 10}). All these results greatly enriched the structures of DACBs in VB. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MALDI MS Imaging at Acquisition Rates Exceeding 100 Pixels per Second

The practicality of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) applied to molecular imaging of biological tissues is limited by the analysis speed. Typically, a relatively low speed of stop-and-go micromotion of XY stages is considered as a factor substantially reducing the rate with which fresh sample material can be supplied to the laser spot. The sample scan rate in our laboratory-built high-throughput imaging TOF mass spectrometer was significantly improved through the use of a galvanometer-based optical scanner performing fast laser spot repositioning on a target plate. The optical system incorporated into the ion source of our MALDI TOF mass spectrometer allowed focusing the laser beam via a modified grid into a 10-μm round spot. This permitted the acquisition of high-resolution MS images with a well-defined pixel size at acquisition rates exceeding 100 pixel/s. The influence of selected parameters on the total MS imaging time is discussed. The new scanning technique was employed to display the distribution of an antitumor agent in 3D colorectal adenocarcinoma cell aggregates; a single MS image comprising 100 × 100 pixels with 10-μm lateral resolution was recorded in approximately 70 s. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CD44v-dependent upregulation of xCT is involved in the acquisition of cisplatin-resistance in human lung cancer A549 cells

Highlights: • Cancer stem cell-like properties disappeared in CDDP-resistant cells. • CD44v overexpression is not involved in cancer stem cell properties. • Increased xCT expression leads to the acquisition of CDDP-resistance. Cisplatin (CDDP) is widely used as an anti-cancer platinum agent but its therapeutic efficacy is limited by acquired drug resistance. To develop a new therapeutic strategy that could overcome this resistance, it is important to characterize CDDP-resistant cancer cells. Here we established human lung cancer A549 cell-derived low- and high-grade CDDP-resistant sublines, termed ACR4 and ACR20 cells, by stepwise increasing CDDP concentrations up to 4 and 20 μM, respectively. ACR4 and ACR20 cells showed 6- and 16-fold higher resistance to CDDP than A549 cells, respectively. Cell migration, invasion, and sphere formation were significantly decreased, whereas expression of the stem cell marker CD44v was increased in order of A549, ACR4, and ACR20 cells. The expression of the cystine-glutamate transporter xCT, which is encoded by SLC7A11, was upregulated because of the increased cell surface expression of CD44v in ACR20 cells. Treatment with the xCT inhibitor salazosulfapyridine and knockdown of SLC7A11 mRNA by a specific siRNA significantly improved sensitivity to CDDP in A549, ACR4, and ACR20 cells. Thus, our results suggest that CD44v overexpression is not involved in cancer stem cell properties but increases xCT expression, which leads to the acquisition of CDDP-resistance. This mechanism may contribute to the development of a new therapeutic strategy that can overcome resistance.

60 APPLIED LIFE SCIENCES↗