Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIMING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The development of molecular water oxidation catalysts

There is an urgent need to transition from fossil fuels to solar fuels $-$ not only to lower CO 2 emissions that cause global warming but also to ration fossil resources. Splitting H 2 O with sunlight emerges as a clean and sustainable energy conversion scheme that can afford practical technologies in the short-to-mid-term. A crucial component in such a device is a water oxidation catalyst (WOC). These artificial catalysts have been developed mainly over the past two decades, which is in contrast to nature’s WOCs, which have featured in its photosynthetic apparatus for more than a billion years. Recent times have seen the development of increasingly active molecular WOCs, the study of which affords an understanding of catalytic mechanisms and decomposition pathways. This Perspective offers a historical description of the landmark molecular WOCs, particularly ruthenium systems, that have guided research to our present degree of understanding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-Doppler vibrating tube densimeter for measurements at high temperatures and pressures

A laser-Doppler vibrometer was used to measure the vibration of a vibrating tube densimeter for measuring P-V-T data at high temperatures and pressures. The apparatus developed allowed the control of the residence time of the sample so that decomposition at high temperatures could be minimized. A function generator and piezoelectric crystal was used to excite the U-shaped tube in one of its normal modes of vibration. Densities of methanol-water mixtures are reported for at 673 K and 40 MPa with an uncertainty of 0.009 g/cm{sup 3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second-sound studies of coflow and counterflow of superfluid {sup 4}He in channels

We report a comprehensive study of turbulent superfluid {sup 4}He flow through a channel of square cross section. We study for the first time two distinct flow configurations with the same apparatus: coflow (normal and superfluid components move in the same direction), and counterflow (normal and superfluid components move in opposite directions). We realise also a variation of counterflow with the same relative velocity, but where the superfluid component moves while there is no net flow of the normal component through the channel, i.e., pure superflow. We use the second-sound attenuation technique to measure the density of quantised vortex lines in the temperature range 1.2 K ≲ T ≲ T{sub λ} ≈ 2.18 K and for flow velocities from about 1 mm/s up to almost 1 m/s in fully developed turbulence. We find that both the steady-state and temporal decay of the turbulence significantly differ in the three flow configurations, yielding an interesting insight into two-fluid hydrodynamics. In both pure superflow and counterflow, the same scaling of vortex line density with counterflow velocity is observed, L∝V{sub cf}{sup 2}, with a pronounced temperature dependence; in coflow instead, the vortex line density scales with velocity as L ∝ V{sup 3/2} and is temperature independent; we provide theoretical explanations for these observations. Further, we develop a new promising technique to use different second-sound resonant modes to probe the spatial distribution of quantised vortices in the direction perpendicular to the flow. Preliminary measurements indicate that coflow is less homogeneous than counterflow/superflow, with a denser concentration of vortices between the centre of the channel and its walls.

42 ENGINEERING↗

Design of a dynamic biofilm imaging cell for white-light interferometric microscopy

In microbiology research there is a strong need for next generation imaging and sensing instrumentation that will enable minimally invasive and label-free investigation of soft, hydrated structures such as in bacterial biofilms. White light interferometry (WLI) can provide high resolution images of surface topology without the use of fluorescent labels but is not typically used to image biofilms because there is insufficient refractive index contrast to induce reflection from the biofilm’s interface. The soft structure and water-like bulk properties of hydrated biofilms make them difficult to characterize in situ , especially in a non-destructive manner. In this report, we build on our prior description of static biofilm imaging and describe the design of a dynamic imaging flow cell that enables monitoring the thickness and topology of live biofilms over time using a WLI microscope. The microfluidic system is specifically designed to create a reflective interface on the surface of biofilms while minimizing disruption of fragile structures. The imaging cell was also designed to accommodate limitations imposed by the depth of focus of the microscope’s objective lens. Example images of live biofilm samples are shown in order to illustrate the ability of the flow cell and WLI instrument to 1) support bacterial growth and biofilm development, 2) image biofilm structure that reflects growth in flow conditions, and 3) monitor biofilm development over time non-destructively. In future work, the apparatus described here will enable surface metrology measurements (roughness, surface area, etc.) of biofilms and may be used to observe changes in biofilm structure in response to changes in environmental conditions (e.g., flow velocity, availability of nutrients, and presence of biocides). Furthermore, this development will open new opportunities for the use of WLI in bioimaging.

47 OTHER INSTRUMENTATION↗

Ge:Ga testing at Cornell

The spiking and memory behavior of a number of Ge:Ga detectors was studied. The detectors were manufactured at a number of locations using several different contacting techniques. Two detectors manufactured for the IRAS program by Rockwell International were studied more extensively than the others. These detectors IRD 1981 and IRD 1982 were 'witness sample' detectors for the IRAS bands 4 and 3, respectively. During the testing period both the apparatus and the test procedures were changed numerous times. At each change consistency checks were made. The data are believed to be internally consistent from end to end.

Briotta, D. A., Jr.↗

Optical multiple sample vacuum integrating sphere

An integrating sphere comprised of a uniform difusely reflecting spherical cavity, having mutually transverse input and output ports, and a linear sample transport mechanism is described. The sample transport mechanism is secured so that the multiple samples can be brought into registration with the input port, one at a time, without having to open or disassemble the apparatus when a change of sample is desired. A vacuum tight seal is provided between the cavity and the transport mechanism. This maintains the integrity of a vacuum generated with the sphere when attached to the source of optical energy. The device is utilized to test emissive characteristics such as the relative fluorescence quantum efficiency of a dye sample placed in the path of a monochromatic optical energy source coupled to the input port while having a light detector coupled to the output port.

Butner, C. L.↗

Comparator with noise suppression

An apparatus for generating a single pulse the first time only that a noisy cyclic signal exceeds a reference level during a half-cycle is disclosed. For the positive half of a cycle of the noisy cyclic signal, a comparator and a multivibrator produce a fixed voltage output when the noisy cyclic signal first exceeds the reference level. A multivibrator stops the production of the fixed voltage output when the noisy cyclic signal next passes the zero voltage level in the negative direction. Consequently, a single pulse is generated indicating that the signal exceeded the reference level during that half-cycle. The comparator and multi-vibrator produce pulses whenever the noisy cyclic signal exceeds the reference level during the negative half-cycle.

Batts, Colossie N.↗

Tension experiments on diaphragm metals

Strips of german silver, steel, copper, duralumin, nickel and brass were tested in tension in an apparatus in which the change in deflection with time was measured by means of an interferometer. This change in deflection with time caused by the application and removal of a load is defined as "drift" and "recovery," respectively. It was measured in the time interval from approximately 5 seconds to 5 hours after loading. The data are given in a series of graphs in which the drift and recovery are plotted against time. The proportional drift and recovery in five hours are given for a number of the tests, and in addition are shown graphically for nickel and steel.

Henrickson, H B↗

Single nanoparticle tracking spectroscopic microscope

A system that can maintain and track the position of a single nanoparticle in three dimensions for a prolonged period has been disclosed. The system allows for continuously imaging the particle to observe any interactions it may have. The system also enables the acquisition of real-time sequential spectroscopic information from the particle. The apparatus holds great promise in performing single molecule spectroscopy and imaging on a non-stationary target.

47 OTHER INSTRUMENTATION↗

Neutronics Analysis of TREAT Multi-SERTTA Calibration Test Vehicle (Multi-SERTTA CAL)

Transient testing is a necessary step in the performance evaluation of Accident Tolerant Fuels (ATF) developed as part of the Fuel Cycle Research and Development Advanced Fuels Campaign initiated and supported by the United States Department of Energy (DOE-NE). These advanced fuels are expected to be used in future reactors or replace the current fuel design used in existing power reactors for enhanced performance and safety. Upon completion of a process proscribed by the National Environmental Policy Act, the Transient Reactor Test (TREAT) facility, located at Idaho National Laboratory (INL), was chosen by DOE-NE to provide the desired specialized testing. TREAT has successfully operated from start-up in 1959 to 1994 when it was placed on operational stand-by. Careful preparations are being made for operational readiness and TREAT is projected to resume testing no later than 2018. Past TREAT testing primarily focused on sodium-cooled reactor fuels (SRF). Test vehicle designs varied to accommodate testing needs ranging from separate effects tests to integral tests approaching simulation of actual reactor environment conditions including forced convection cooling. The current focus on light water reactor (LWR) ATF requires design of new experiment vehicles to accommodate the water/steam environment and associated complexities regarding desired energy deposition into the specimen and proper containment. The first set of experiments in TREAT restart is expected to be conducted with the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses). Difficult to quantify and calculate integral and time dependent effects inherent in transient testing limit predictive modeling capability; therefore, calibration testing in TREAT prior to the actual experiment is necessary to empirically determine the effectiveness of core-to-specimen power coupling in order to achieve the desired energy deposition into the test specimen during a nuclear power transient. This has been done in the past, in part, by evaluating the difference in energy deposition into dosimeter wires subjected to various TREAT time dependent power conditions. These calibration tests were typically conducted in a test vehicle neutronically similar to the actual test vehicle, but more simplistic in design in order to quickly retrieve and analyze dosimeter wires and minimize containment structure costs due to several trials. Prior calibration testing for SRF experiments could be conducted without coolant as sodium has no notable neutronic effect on the core-to-specimen power coupling factor (PCF). Such is not the case with LWR fuel where water serves as both moderator and coolant. This presents a design challenge as the calibration test vehicle must retain heated, high-pressure water to preserve neutronic equivalence representative of near prototypic reactor conditions while allowing for quick retrieval of dosimeters. The solution to this challenge comes in the form of a thin walled dry well positioned through the center of the basic Multi-SERTTA design. Test vehicle reactivity worth and PCF are two important factors with respect to ascertainment of neutronic equivalence. Similarity in test vehicle reactivity worth is desired to avoid the need to change operational core rod positions in TREAT which could significantly alter neutron flux distribution and consequently power distribution throughout the core and into the test specimen. The geometry and composition of various materials within the experiment containment structure can also significantly alter the quality of neutron signal delivery from the core to the test specimen. Introduction of an Inconel tube, albeit very thin, is expected to impact PCF. Simple modifications to the CAL design may compensate for the anticipated change. Evaluation of these factors and proposed modifications through neutronics analysis serves to inform experiment design and is a valuable tool towards achieving the optimal CAL design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Absorption of CO2-laser radiation in a hypocycloidal-pinch plasma

Absorption of a 50-J pulsed CO2 laser beam in the plasma produced in a hypocycloidal-pinch apparatus was studied. The apparatus consists of three disk electrodes with a 5-cm hole on the axis. The current sheets are snow-plowed toward the center of the hole to produce a plasma with a density greater than 10 to the 18th/cu cm and a temperature near 1 keV which emits soft X rays for 5 microsec. IR detectors measured the laser radiation incident onto, transmitted through, and scattered from the plasma as functions of time. For a period up to 70 microsec from the onset of X-ray emission, neither transmitted nor scattered laser radiation was observed above the detector threshold of 0.3% of the incident flux. This indicates effective absorption of the laser beam (greater than 99%) and that the particle confinement time extends far beyond the energy confinement time of 5 microsec. Thus, the plasma in this apparatus appears much more amenable to laser heating than that in a theta pinch.

Lee, J. H.↗

Formation of tetragonal hydrogen tungsten bronze by reactive mechanical alloying

Hydrogen tungsten bronzes have been synthesized by reactive mechanical alloying monoclinic tungsten (VI) oxide under hydrogen atmosphere. Two milling devices with different energy ranges were used. Regardless of the distinct reaction times, a similar phase evolution was observed with both apparatus. The characterization of the materials was performed by XRD, SEM, DSC and total hydrogen content determination. The final product obtained was a mixture of tetragonal H{sub 0.33}WO{sub 3} and H{sub 0.23}WO{sub 3} bronzes. - Graphical abstract: Hydrogen tungsten bronzes have been synthesized by reactive mechanical alloying (RMA) monoclinic WO{sub 3} under H{sub 2} atmosphere. By using two milling devices with different energy ranges a similar phase evolution with distinct reaction times was observed. The materials were characterized by XRD, SEM, DSC and total hydrogen content determination. The final product obtained was a mixture of tetragonal H{sub 0.33}WO{sub 3} and H{sub 0.23}WO{sub 3} bronzes. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method and apparatus for non-invasive evaluation of diaphragmatic function

A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.

Yost, William T.↗

Method and apparatus for non-invasive evaluation of diaphragmatic function

A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.

Yost, William T.↗

Thermalite Apparatus

Thermalite is portable apparatus that nondestructively determines thermal-diffusion properties of specimen. Based on heat-pulse method; it applies pulse of heat to specimen, then computes relevant thermal properties of specimen from time-resolved measurements of thermal response of specimen to heat pulse. Apparatus is self-contained and calibrated and tested with stored thermal pattern as standard. Used to assess flaw in specimen.

Heyman, Joseph S.↗

High-resolution Rydberg tagging time-of-flight measurements of atomic photofragments by single-photon vacuum ultraviolet laser excitation

By coupling a comprehensive tunable vacuum ultraviolet (VUV) laser system to a velocity-mapped ion imaging apparatus, we show that high-resolution high-n Rydberg tagging time-of-flight (TOF) measurements of nascent atomic photofragments formed by laser photodissociation can be made using single-photon VUV laser photoexcitation. To illustrate this single-photon Rydberg tagging TOF method, we present here the results of the VUV laser high-n Rydberg tagging TOF measurements of O({sup 3}P{sub 2}) and S({sup 3}P{sub 2}) formed in the photodissociation of SO{sub 2} and CS{sub 2} at 193.3 and 202.3 nm, respectively. These results are compared to those obtained by employing the VUV laser photoionization time-sliced velocity-mapped ion imaging technique. The fact that the kinetic energy resolutions achieved in the VUV laser high-n Rydberg tagging TOF measurements of O and S atoms are found to be higher than those observed in the VUV laser photoionization, time-sliced velocity-mapped ion imaging studies show that the single-photon VUV laser high-n Rydberg tagging TOF method is useful and complementary to state-of-the-art time-sliced velocity-mapped ion imaging measurements of heavier atomic photofragments, such as O and S atoms. Furthermore, the general agreement observed between the VUV laser high-n Rydberg tagging TOF and velocity-mapped ion imaging experiments supports the conclusion that the lifetimes of the tagged Rydberg states of O and S atoms are sufficiently long to allow the reliable determination of state-resolved UV photodissociation cross sections of SO{sub 2} and CS{sub 2} by using the VUV laser high-n Rydberg tagging TOF method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic real-time pair-feeding system for animals

A pair feeding method and apparatus are provided for experimental animals wherein the amount of food consumed is immediately delivered to a normal or control animal so that there is a qualitative, quantitative and chronological correctness in the pair feeding of the two animals. This feeding mechanism delivers precisely measured amounts of food to a feeder. Circuitry is provided between master and slave feeders so that there is virtually no chance of a malfunction of the feeding apparatus, causing erratic results. Recording equipment is also provided so that an hourly record is kept of food delivery.

Leon, H. A.↗

Robust low-frequency spread-spectrum navigation system

Methods and apparatus are described for a navigation system. A process includes providing a plurality of transmitters distributed throughout a desired coverage area; locking the plurality of transmitters to a common timing reference; transmitting a signal from each of the plurality of transmitters. An apparatus includes a plurality of transmitters distributed throughout a desired coverage area; wherein each of the plurality of transmitters comprises a packet generator; and wherein the plurality of transmitters are locked to a common timing reference.

47 OTHER INSTRUMENTATION↗