Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

An adaptive quantization method for burst mode synthetic aperture radar data

Synthetic aperture radar (SAR) has high data rate because it collects and processes the data coherently. The data rate limitation of the system has to be satisfied while maintaining good image quality. Thus, a quantizer with minimum data rate and high SNR should be employed. An adaptive quantization method is proposed for the burst mode SAR. This adaptive quantizer uses uniformly quantized data to select a subset of bits which is equivalent to changing the step size of the uniform quantizer. A simple implementation which uses the previous burst data to compute the local statistics for the bit selection is presented. The use of previous burst simplifies the implementation because it does not require storage or delay; however, an abrupt change in the terrain could result in incorrect bit selection. An error analysis of this implementation and comparison of two burst mode SAR images formed using the uniformly quantized and adaptively quantized data is presented.

Joo, T. H.↗

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗

Preliminary Study of JPSS-1/NOAA-20 VIIRS Day-Night Band Straylight Characterization and Correction Methods

The JPSS-1 (now named NOAA-20) VIIRS instrument has successfully operated since its launch in November 18, 2017. A panchromatic channel onboard NOAA-20 VIIRS is called the day-night band (DNB). With its large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. However, the DNB night image quality is affected by the straylight contamination. In this study, we focused on Earth view data in the midto-high latitude of the northern and southern hemispheres when spacecraft is crossing the day/night terminators at the beginning of NOAA-20 mission. Based on on-orbit data analysis from previous VIIRS sensor onboard S-NPP mission, straylight contamination mainly depends on the Earth-Sun-spacecraft geometry, and it is also detector and scan-angle dependent. Inter-comparison investigation of straylight behavior in both SNPP and NOAA-20 instruments will be conducted to better understand straylight characteristics. The preliminary study has been performed in this paper to mitigate straylight contamination for NOAA-20VIIRS DNB night images. The effectiveness of the straylight correction algorithm, directly adapted from the S-NPP DNB, is assessed for night images in the day/night terminators. Further work has been identified to improve current straylight correction methodology and DNB-based environmental data products.NOAA-20.

Day-Night Band↗

Investigation of Primary Mirror Segment's Residual Errors for the Thirty Meter Telescope

The primary mirror segment aberrations after shape corrections with warping harness have been identified as the single largest error term in the Thirty Meter Telescope (TMT) image quality error budget. In order to better understand the likely errors and how they will impact the telescope performance we have performed detailed simulations. We first generated unwarped primary mirror segment surface shapes that met TMT specifications. Then we used the predicted warping harness influence functions and a Shack-Hartmann wavefront sensor model to determine estimates for the 492 corrected segment surfaces that make up the TMT primary mirror. Surface and control parameters, as well as the number of subapertures were varied to explore the parameter space. The corrected segment shapes were then passed to an optical TMT model built using the Jet Propulsion Laboratory (JPL) developed Modeling and Analysis for Controlled Optical Systems (MACOS) ray-trace simulator. The generated exit pupil wavefront error maps provided RMS wavefront error and image-plane characteristics like the Normalized Point Source Sensitivity (PSSN). The results have been used to optimize the segment shape correction and wavefront sensor designs as well as provide input to the TMT systems engineering error budgets.

warping harness↗

Pupil Alignment Considerations for Large, Deployable Space Telescopes

For many optical systems the properties and alignment of the internal apertures and pupils are not critical or controlled with high precision during optical system design, fabrication or assembly. In wide angle imaging systems, for instance, the entrance pupil position and orientation is typically unconstrained and varies over the system s field of view in order to optimize image quality. Aperture tolerances usually do not receive the same amount of scrutiny as optical surface aberrations or throughput characteristics because performance degradation is typically graceful with misalignment, generally only causing a slight reduction in system sensitivity due to vignetting. But for a large deployable space-based observatory like the James Webb Space Telescope (JWST), we have found that pupil alignment is a key parameter. For in addition to vignetting, JWST pupil errors cause uncertainty in the wavefront sensing process that is used to construct the observatory on-orbit. Furthermore they also open stray light paths that degrade the science return from some of the telescope s instrument channels. In response to these consequences, we have developed several pupil measurement techniques for the cryogenic vacuum test where JWST science instrument pupil alignment is verified. These approaches use pupil alignment references within the JWST science instruments; pupil imaging lenses in three science instrument channels; and unique pupil characterization features in the optical test equipment. This will allow us to verify and crosscheck the lateral pupil alignment of the JWST science instruments to approximately 1-2% of their pupil diameters.

Bos, Brent J.↗

White-Light Phase-Conjugate Mirrors as Distortion Correctors

White-light phase-conjugate mirrors would be incorporated into some optical systems, according to a proposal, as means of correcting for wavefront distortions caused by imperfections in large optical components. The proposal was given impetus by a recent demonstration that white, incoherent light can be made to undergo phase conjugation, whereas previously, only coherent light was known to undergo phase conjugation. This proposal, which is potentially applicable to almost any optical system, was motivated by a need to correct optical aberrations of the primary mirror of the Hubble Space telescope. It is difficult to fabricate large optical components like the Hubble primary mirror and to ensure the high precision typically required of such components. In most cases, despite best efforts, the components as fabricated have small imperfections that introduce optical aberrations that adversely affect imaging quality. Correcting for such aberrations is difficult and costly. The proposed use of white-light phase conjugate mirrors offers a relatively simple and inexpensive solution of the aberration-correction problem. Indeed, it should be possible to simplify the entire approach to making large optical components because there would be no need to fabricate those components with extremely high precision in the first place: A white-light phase-conjugate mirror could correct for all the distortions and aberrations in an optical system. The use of white-light phase-conjugate mirrors would be essential for ensuring high performance in optical systems containing lightweight membrane mirrors, which are highly deformable. As used here, "phase-conjugate mirror" signifies, more specifically, an optical component in which incident light undergoes time-reversal phase conjugation. In practice, a phase-conjugate mirror would typically be implemented by use of a suitably positioned and oriented photorefractive crystal. In the case of a telescope comprising a primary and secondary mirror (see figure) white light from a distant source would not be brought to initial focus on one or more imaging scientific instrument(s) as in customary practice. Instead, the light would be brought to initial focus on a phase-conjugate mirror. The phase-conjugate mirror would send a phase-conjugate image back, along the path of the incoming light, to the primary mirror. A transparent, highly efficient diffractive thin film deposited on the primary mirror would direct the phase-conjugate image to the imaging instrument(s).

Frazier, Donald↗

Comparison of MPEG digital video with super VHS tape for diagnostic echocardiographic readings

BACKGROUND: Digital recording of echocardiographic studies is on the clinical horizon. However, full digital capture of complete echocardiographic studies in traditional video format is impractical, given current storage capacity and network bandwidth. To overcome these constraints, we evaluated the diagnostic image quality of digital video by using MPEG (Motion Picture Experts Group) compression. METHODS AND RESULTS: Fifty-eight complete, consecutive studies were recorded simultaneously with the use of MPEG-1 and sVHS videotape. Each matched MPEG and sVHS study pair was reviewed by two from a total of six readers, and findings were recorded with the use of a detailed, computerized reporting tool. Intrareader and interreader discrepancies were characterized as major or minor and analyzed in total and for specific subgroups of findings (left and right ventricular parameters, valvular insufficiency, and left ventricular regional wall motion). Intrareader discrepancies were reviewed by a consensus panel for agreement with either MPEG or sVHS findings. There was an exact concordance between MPEG and sVHS readings in 83% of findings. The majority of discrepancies were minor, with major discrepancies in only 2.7% of findings. There was no difference in the rate of consensus panel agreement with MPEG or sVHS for instances of intrareader discrepancy, either in total or for any subgroup of findings. Interreader discrepancy rates were nearly identical for both MPEG and sVHS. CONCLUSIONS: MPEG-1 digital video is equivalent to sVHS videotape for diagnostic echocardiography. MPEG increases the range of practical options for digital echocardiography and offers, for the first time, the advantages of digital recording in a familiar video format.

Non-NASA Center↗

Discrete control of linear distributed systems with application to the deformable primary mirror of a large orbiting telescope

One of the more significant technological problems associated with the orbital operation of large astronomical telescope's is the fabrication and maintenance of the primary mirror surface to the tolerance required for diffraction-limited performance. An interesting approach to the solution of this problem involves continuously measuring and automatically correcting the optical surface of a thin deformable mirror by means of discrete actuators located on its rear surface: The realization of diffraction-limited performance from a telescope in space by this method rests on the ability of the designer to achieve extremely accurate control of a highly complex, interacting, multivariable system. This paper presents the results of a detailed study of the discrete control of linear distributed systems with specific application to the design of a practical controller for a plant representative of a telescope primary mirror for an orbiting astronomical observatory. The problem of controlling the distributed plant is treated by employing modal techniques to represent variations in the optical figure. Distortion of the mirror surface, which arises primarily from thermal gradients, is countered by actuators working against a backing structure to apply a corrective force distribution to the controlled surface. Each displacement actuator is in series with a spring attached to the mirror by means of a pad intentionally introduced to restrict the excitation of high-order modes. Control is then exerted over a finite number (equal.to the number of actuators) of the most significant modes. Through the application of the modal expansion technique the mirror equation of motion is transformed tb a set of uncoupled, linear, time-invariant, ordinary differential equations. The desired dynamic response and static accuracy may then be achieved by the application of classical single-variable design techniques. The formulation of a quadratic performance index which incorporates a measure of image quality permits determination of the trade-off between the-number of actuators and optical purity. A criterion for defining actuator placement and pad size is presented which minimizes the tendency of the controller to excite the unmonitored modes.

Jeremiah F Creedon↗

Analyses of requirements for computer control and data processing experiment subsystems. Volume 1: ATM experiment S-056 image data processing system techniques development

The solar imaging X-ray telescope experiment (designated the S-056 experiment) is described. It will photograph the sun in the far ultraviolet or soft X-ray region. Because of the imaging characteristics of this telescope and the necessity of using special techniques for capturing images on film at these wave lengths, methods were developed for computer processing of the photographs. The problems of image restoration were addressed to develop and test digital computer techniques for applying a deconvolution process to restore overall S-056 image quality. Additional techniques for reducing or eliminating the effects of noise and nonlinearity in S-056 photographs were developed.

Source record↗

Apollo 9 multiband photography experiment S065

Fourier analysis was applied to microdensitometer scans of a selected region of one SO65 frame in each of the three black-and-white bands. The approach was unique because a somewhat arbitrary section of the image was used and not limited to available targets as in edge analysis. Comparison of duplicates and calculation of absolute SO65 MTF were done by applying linear systems theory to the spatial spectra of the image scans. It was found that the duplication process was nonlinear and resulted in general amplification of spatial frequency modulation. However, the increase in modulation was offset by a corresponding increase in the granularity of the copies. The amount of increase seemed to be related to the initial granularity, but a direct relationship was not verified. Band-to-band comparison of image quality was achieved in the form of signal-to-noise ratio curves as a function of spatial frequency for each band. From this standpoint the DD band was an order of magnitude better than the other two. These were several factors that restricted the analysis of the Apollo 9 imagery. Among these were the lack of precise sensitometric and optical system data on the high altitude photography. In addition it was determined that there was only one simultaneous pair of high altitude and SO65 frames. Finally, the original SO65 photography was not available for scanning (for obvious reasons), thus eliminating a reference base for granularity and SO65 MTF determination.

Schowengerdt, R. A.↗

Cartographic application of ERTS imagery

There are no author-identified significant results in this report. Results of a quick look of selected ERTS-1 imagery with respect to cartographic applications and products are presented. The term cartographic is applied to graphics that have been related to an accepted reference figure of the earth within a prescribed degree of accuracy. The results are presented in the form of figures covering: (1) nongeometric relative image quality; (2) geometric properties (preliminary); (3) first phase photoimage products; (4) intermediate phase photoimage products; (5) optimum phase orthophotoquad products; and (6) cartographic applications. Because of its unique vantage point of 920 km, ERTS-1 will be a powerful mapping tool by providing extensive and continuous up-to-date data.

Colvocoresses, A. P.↗

Selected-zone dark-field electron microscopy.

Description of a new method which makes it possible to reduce drastically the resolution-limiting influence of chromatic aberration, and thus to obtain high-quality images, by selecting the image-forming electrons that have passed through a small annular zone of an objective lens. In addition, the manufacture of special objective-lens aperture diaphragms that are needed for this method is also described.

Heinemann, K.↗

The Thailand programme of Earth Resources Technology Satellite

The author has identified the following significant results. Multispectral scanner image quality is considered excellent. It is immediately apparent that details of the coastline, water courses, and many other features readily apparent in the imagery will permit important updating and correction of available maps of Thailand.

Cheosakul, P.↗

Overall evaluation of ERTS-1 imagery for cartographic application

The author has identified the following significant results. Significant scientific conclusions are: (1) Bulk RBV's have internal positional accuracy in the order of 70 meters at ground scale while MSS internal accuracy is in the order of 200 to 300 meters. Both have precision processed images with accuracy within 70 meters. (2) Image quality exhibited by detectability and acutance is better than expected and perhaps twice as good as would be achieved by photographic film of the same resolution. (3) Photometric anomalies (shading) have limited RBV multispectral application, but it is believed that these anomalies can be further reduced. (4) The MSS has exceptionally high photometric fidelity but the matching of scenes taken under different conditions of illumination has not been resolved. (5) MSS bands 6 and 7 have enormous potential for surface water mapping including the correlation of shorelines at various water stages. (6) MSS band 7 demonstrates an actual cloud penetration capability beyond what was expected. It also has delineated cultural features better than the other MSS bands under certain conditions.

Colvocoresses, A. P.↗

Investigation of ERTS/RBV imagery for photomapping of the United States

The author has identified the following significant results. Multispectral scanner imagery substituted for the RBV imagery appears to have surpassed initial evaluation of the anticipated image quality as compared to the expected quality of the RBV imagery. A comparison of the imagery from the two systems over the same scene will help in determining the value of each system.

Pilonero, J. T.↗