New approaches in correlative studies of biological ultrastructure by high-resolution electron microscopy
Correlative studies of biological ultrastructure by high resolution electron microscopy
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Correlative studies of biological ultrastructure by high resolution electron microscopy
Digital images captured with electron microscopes are corrupted by two fundamental effects: shot noise resulting from electron counting statistics and blur resulting from the nonzero width of the focused electron beam. The generic problem of computationally undoing these effects is called image reconstruction and for decades has proved to be one of the most challenging and important problems in imaging science. This proposal concerned the application of the Pixon method, the highest-performance image-reconstruction algorithm yet devised, to the enhancement of images obtained from the highest-resolution electron microscopes in the world, now in operation at Oak Ridge National Laboratory.
Photoemission Electron Microscopy (PEEM) is a versatile tool that relies on the photoelectric effect to produce high-resolution images. Pulse lasers allow for multi-photon PEEM where multiple photons are required excite a single electron. This non-linear process can directly image the near field region of electromagnetic fields in materials. We use this ability here to analyze wave propagation in a linear dielectric waveguide with wavelengths of 410nm and 780nm. The propagation constant of the waveguide can be extracted from the interference pattern created by the coupled and incident light and shows distinct polarization dependence. Furthermore, the electromagnetic field interaction at the boundaries can then be deduced which is essential to understand power flow in wave guiding structures. These results match well with simulations using finite element techniques.
Identification of amorphous phases in nanoparticles by atomic-resolution transmission electron microscopy (TEM) requires analyses such as tilt-angle-dependent TEM imaging and single-nanoparticle electron diffraction, rather than relying on a single TEM image. Here, the disordered structures of amorphous nanoparticles offer unique atomic configurations and properties that differ from the properties of their crystalline counterparts. These characteristics have motivated the exploration of such materials for mechanical, sensing and catalytic applications. In addition, the formation of amorphous metal nanoparticles is an important endeavour to understand the process of vitrification and the nature of the glassy state. Atomic-resolution transmission electron microscopy (TEM) is increasingly being used as a tool for characterizing structures of nanoparticles produced by vitrification. In this Comment, we discuss the pitfalls of using TEM for ascertaining whether nanoparticles are amorphous. We also make recommendations of best practices.
We describe the direct imaging—with four-dimensional ultrafast electron microscopy—of the emergence, evolution, dispersion, and decay of photoexcited, hypersonic coherent acoustic phonons in nanoscale germanium wedges. Coherent strain waves generated via ultrafast in situ photoexcitation were imaged propagating with initial phase velocities of up to 35 km/s across discrete micrometer-scale crystal regions. We then observe that, while each wave front travels at a constant velocity, the entire wave train evolves with a time-varying phase-velocity dispersion, displaying a single-exponential decay to the longitudinal speed of sound (5 km/s) and with a mean lifetime of 280 ps. We also find that the wave trains propagate along a single in-plane direction oriented parallel to striations introduced during specimen preparation, independent of crystallographic direction. Elastic-plate modeling indicates the dynamics arise from excitation of a single, symmetric (dilatational) guided acoustic mode. Further, by precisely determining the experiment time-zero position with a plasma-lensing method, we find that wave-front emergence occurs approximately 100 ps after femtosecond photoexcitation, which matches well with Auger recombination times in germanium. We conclude by discussing the similarities between the imaged hypersonic strain-wave dynamics and electron/hole plasma-wave dynamics in strongly photoexcited semiconductors.
Glassy carbon, a monoatomic allotrope of carbon, is a candidate material for components in fission nuclear power systems due to its radiation tolerance. This article presents comprehensive electron microscopy data revealing the effects of neutron and electron irradiation on glassy carbon. For comparison, additional data are provided for pyrolytic graphite and carbon fibers, materials that exhibit similar structural behavior under irradiation. In situ electron irradiation experiments further illustrate the real-time microstructural evolution of glassy carbon during exposure. The dataset is organized into five parts: (1) transmission electron microscopy (TEM) micrographs of as-received and neutron-irradiated glassy carbon; (2) TEM micrographs of neutron-irradiated graphite; (3) TEM micrographs of unirradiated and irradiated carbon–carbon composites; (4) TEM micrographs of pyrolytic carbon specimens in both conditions; (5) scanning transmission electron microscopy (STEM) micrographs of as-received and neutron-irradiated glassy carbon and (6) in situ electron irradiation data of a glassy carbon particle. These datasets provide valuable insights into radiation-induced structural changes in carbon-based materials relevant to nuclear applications.
Positive electrodes for Li-ion batteries based on Li[Li{sub 1/3-2x/3}Ni{sub x}Mn{sub 2/3-x/3}]O{sub 2} (0 {le} x {le} 0.5) compounds are of significant interest because of their ability to deliver reversible capacities exceeding 200 mAh g{sup -1}. In this article we describe the examination of Li{sub 1.2}Ni{sub 0.2}Mn{sub 0.6}O{sub 2} (x = 0.2 in Li[Li{sub 1/3-2x/3}Ni{sub x}Mn{sub 2/3-x/3}]O{sub 2}) samples by X-ray diffraction (XRD), high-resolution electron microscopy (HREM), scanning transmission electron microscopy (STEM), electron diffraction, X-ray energy dispersive spectroscopy (EDS), and electron energy loss spectroscopy (EELS). The studies were conducted on freshly prepared oxides, and on oxide electrodes that were electrochemically activated by cycling twice between 4.8 and 2.0 V vs. Li{sup +}/Li. Rectangular and parallelogram shaped dot arrays with a spacing of 0.43 nm observed in HREM and STEM images along the [10{bar 1}0] zone axis, as well as streaks at 1/3 n (11{bar 2}0) (n = integer) positions in corresponding electron diffraction patterns, indicated ordering of Li-ions in the transition-metal (TM) (0 0 0 1) layers following several stacking sequences, bounded by stacking faults, along the c-axis. Chemical analysis by EDS and EELS showed that Mn, Ni and O were present in all portions of the samples examined; no evidence of elemental segregation was observed either within the grains or at grain boundaries. The Li ordering on TM planes was significantly weaker but still discernable upon electrochemical activation of the oxide samples.
Due to the exceptional performance of most modern commercial transmission electron microscopes, the achievement of phase-contrast imaging resolution in the sub-2Å range is today a routine exercise, provided the samples are compliant. Nonetheless, there remains room for improvement, and the purpose of this manuscript is to highlight procedures that might be employed by the practicing microscopist for advancing conventional high resolution electron microscopy.
We present a detailed structural characterization of the interfaces in Fe/MgO/Fe layers grown by molecular-beam epitaxy using aberration-corrected transmission electron microscopy (TEM), scanning TEM, and electron energy-loss spectroscopy. When fabricated into magnetic tunnel junctions, these epitaxial devices exhibit large tunnel magnetoresistance ratios (e.g., 318% at 10 K), though still considerably lower than the values predicted theoretically. The reason for this discrepancy is being debated and has been attributed to the structure of, and defects at the interface, namely, the relative position of the atoms, interface oxidation, strain, and structural asymmetry of the interfaces. In this structural study, we observed that Fe is bound to O at the interfaces. The interfaces are semicoherent and mostly sharp with a minor degree of oxidation. A comparison of the two interfaces shows that the top MgO/Fe interface is rougher.
Summary A sample of a nanomaterial contains a distribution of nanoparticles of various shapes and/or sizes. A scanning electron microscopy image of such a sample often captures only a fragment of the morphological variety present in the sample. In order to quantitatively analyse the sample using scanning electron microscope digital images, and, in particular, to derive numerical representations of the sample morphology, image content has to be assessed. In this work, we present a framework for extracting morphological information contained in scanning electron microscopy images using computer vision algorithms, and for converting them into numerical particle descriptors. We explore the concept of image representativeness and provide a set of protocols for selecting optimal scanning electron microscopy images as well as determining the smallest representative image set for each of the morphological features. We demonstrate the practical aspects of our methodology by investigating tricalcium phosphate, Ca 3 (PO 4 ) 2 , and calcium hydroxyphosphate, Ca 5 (PO 4 ) 3 (OH), both naturally occurring minerals with a wide range of biomedical applications.
Electron microscopy using high field superconducting niobium-zirconium solenoid lenses, showing image recording of exceptional stability and quality
A common strategy aimed at achieving a high temporal resolution in ultrafast electron microscopy and diffraction is based on the use of strong electrostatic fields in the accelerating gap to form fast electron pulses of ultrashort duration. In this work, the dynamics of the propagation of ultrashort photoelectron bunches is studied taking into account the time-of-flight chromatic aberration: the spread-out of electron pulses at the exit from the region of the accelerating electric field. The results of the calculation of the duration of photoelectron pulses taking into account Coulomb repulsion are presented. According to the analysis, the use of strong electrostatic fields in the accelerating gap for the formation of fast electron pulses of ultrashort duration is not a necessary condition for achieving the final high temporal resolution in the method of ultrafast electron microscopy. The modes of operation of ultrafast transmission electron microscope were found for which the temporal resolution increases with the growth of time-of-flight chromatic aberration.
In femtosecond (fs) 4D ultrafast electron microscopy (UEM), a tradeoff is made between photoelectrons per packet and time resolution. One consequence of this can be longer-than-desirable acquisition times for low-density packets, and particularly for low repetition rates when complete photothermal dissipation is required. Thus, gaining an understanding of photoelectron trajectories in the gun region is important for identifying factors that limit collection efficiency (CE; fraction of photoelectrons that enter the illumination system). Here, we continue our work on the systematic study of photoelectron trajectories in the gun region of a Thermo Fisher/FEI Tecnai Femto UEM, focusing specifically on CE in the single-electron regime. Using General Particle Tracer, calculated field maps, and the exact architecture of the Tecnai Femto UEM, we simulated the effects of fs laser parameters and key gun elements on CE. The results indicate CE strongly depends upon the laser spot size on the source, the (unbiased) Wehnelt aperture diameter, and the incident photon energy. The CE dispersion with laser spot size is found to be strongly dependent on aperture diameter, being nearly dispersionless for the largest apertures. A gun crossover is also observed, with the beam-waist position being dependent on the aperture diameter, further illustrating that the Wehnelt aperture acts as a simple, fixed electrostatic lens in UEM mode. This work provides further insights into the operational aspects of fs 4D UEM.
Preliminary analyses of regolith samples from asteroid Bennu show high bulk carbon abundances (~4.7 wt.%). The organic matter is readily apparent in scanning electron microscopy (SEM), transmission electron microscopy (TEM), and NanoSIMS observations. A major objective of the OSIRIS-REx mission is to understand the nature and origin of the pre-biotic organic matter inventory in Bennu samples. Here we report on TEM studies of indigenous organic matter in Bennu aggregate samples.
Critical applications of spin polarized low energy electron microscopy (SPLEEM) employ this technique's vector imaging capability to resolve domain wall (DW) spin textures. Studying several thin film systems including Co/W(110), Co/Cu(001) and (Co/Ni) n /W(110), we demonstrate that an additional contrast can appear at magnetic DWs. By imaging the magnetization as a function of electron landing energy, electron energies are selected at which the magnetic domain contrast vanishes. Surprisingly, under such conditions of zero contrast between magnetic domains, we observe the appearance of magnetic contrast outlining the DWs. This DW contrast fails to depend on the DW spin texture. Instead, our measurements show that this DW contrast results from a combination of the energy-dependence of the spin reflectivity asymmetry of the magnetic film, the finite energy width of the spin polarized electron source, and the dispersion of the magnetic prism array that separates the illumination and imaging columns of the instrument. Awareness of this DW contrast mechanism is useful to aid correct interpretation of SPLEEM images.
For this work, we employ analytical transmission electron microscopy (TEM) to correlate the structural and chemical environment variations within a stacked epitaxial thin film of the high entropy oxide (HEO) Mg 0.2 Co 0.2 Ni 0.2 Cu 0.2 Zn 0.2 O (J14), with two layers grown at different substrate temperatures (500 and 200 °C) using pulsed laser deposition (PLD). Electron diffraction and atomically resolved STEM imaging reveal the difference in out-of-plane lattice parameters in the stacked thin film, which is further quantified on a larger scale using four-dimensional STEM (4D-STEM). In the layer deposited at a lower temperature, electron energy loss spectroscopy (EELS) mapping indicates drastic changes in the oxidation states and bonding environment for Co ions, and energy-dispersive X-ray spectroscopy (EDX) mapping detects more significant cation deficiency. Ab initio density functional theory (DFT) calculations validate that vacancies on the cation sublattice of J14 result in significant electronic and structural changes. The experimental and computational analyses indicate that low temperatures during film growth result in cation deficiency, an altered chemical environment, and reduced lattice parameters while maintaining a single phase. Our results demonstrate that the complex correlation of configurational entropy, kinetics, and thermodynamics can be utilized for accessing a range of metastable configurations in HEO materials without altering cation proportions, enabling further engineering of functional properties of HEO materials.
The contrast of biological samples in scanning electron microscopy (SEM) is very weak. To examine a biological specimen by SEM, many steps and/or special equipment are required to prepare the sample. Here, we describe a method using an unstained biological sample under a 40 nm carbon film to give a high contrast image, where the image is detected by the secondary electron (SE) signal at a low accelerating voltage of 1.5 kV. Under these conditions, it is hard to detect a direct signal from a biological specimen. The high contrast image is created by the SEs from the lower surface of the thin carbon film. Therefore, the damage to the sample from the electron beam is very low. Our method can be utilized to observe various biological samples of bacteria, viruses, and protein complexes.
Semiconducting diamond films have the potential for use as a material in which to build active electronic devices capable of operating at high temperatures or in high radiation environments. Ultimately, it is preferable to use low-defect-density single crystal diamond for device fabrication. We have previously investigated polycrystalline diamond films with transmission electron microscopy (TEM) and scanning electron microscopy (SEM), and homoepitaxial films with SEM-based techniques. This contribution describes some of our most recent observations of the microstructure of natural diamond single crystals and homoepitaxial diamond thin films using TEM.