Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clean room”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Natural-oxide solar-collector coatings

Optically selective coatings for solar collectors are produced by thermally treating stainless steel in furnace after series of cleaning and soaking operations. Coatings have withstood 18-month exposure tests at 100 percent relative humidity and temperatures of 95 F. Room temperature coatings are valuable as they are inexpensive to produce, highly production oriented, and environmentally stable.

Krupnick, A. C.↗

Electrochemical cleaning: An in-Situ method to reverse chromium poisoning in solid oxide fuel cell cathodes

Chromium poisoning is one of the primary factors that affect solid oxide fuel cell (SOFC) durability. In this study, an electrochemical cleaning method has been employed to reverse the effects of chromium poisoning. Two cells were fabricated and poisoned under identical conditions by operating them at 800°C in the presence of a Cr source. Both poisoned cells exhibited a significant reduction in maximum power density and an increase in polarization resistance. One of the poisoned cells, designated as the baseline cell, was cooled to room temperature after poisoning. Microstructural observation of the baseline cell showed significant contamination of the cathode active layer by chromium oxide and (Cr,Mn) spinel deposits. The other poisoned cell was electrochemically cleaned for two hours under a mild electrolytic condition. As a result of the electrochemical cleaning process, the chromium oxide deposits were substantially removed leading to a significant reduction of Cr concentration in the cathode, especially at the cathode/electrolyte interface. Furthermore, a substantial fraction of the cell performance loss was also reversed. To the best of our knowledge, this is a first demonstration of reversing the effects of chromium poisoning using a rapid in-situ process.

30 DIRECT ENERGY CONVERSION↗

Rapid Biochemical Analysis on the International Space Station (ISS): Preparing for Human Exploration of the Moon and Mars

The Lab-on-a-Chip Application Development - Portable Test System, known as LOCAD-PTS, was launched to the International Space Station (ISS) aboard Space Shuttle Discovery (STS-116) on December 9th,2006. Since that time, it has remained onboard ISS and has been operated by the crew on 10 separate occasions LOCAD-PTS is a handheld device for rapid biochemical analysis; it consists of a spectrophotometer, a series of interchangeable cartridges, a pipette and several clean/sterilized swabbing kits to obtain samples from ISS surfaces. Sampling, quantitative analysis and data retrieval is performed onboard, therefore reducing the need to return samples to Earth. Less than 20 minutes are required from sampling to data, significantly faster than existing culture-based methods on ISS, which require 3-5 days. Different cartridges are available for the detection of different target molecules (simply by changing the formulation within each cartridge), thereby maximizing the benefit and applications addressed by a single instrument. Initial tests on ISS have focused on the detection of the bact.erial macromolecule endotoxin, a component of bacterial cell walls. LOCAD-PTS detects endotoxin with a cartridge that contains a formulation known as Limulus Amebocyte Lysate (LAL) assay. LAL is derived from blood of the horseshoe crab, Limulus polyphemus, and detects enodotoxin with an enzyme cascade that triggers generation Of a yellow colored dye, p-nitroanaline. The more p-nitroanaline product, the more endotoxin is in the original sample. To enable quantitative analysis, the absorbance of this color is measured by LOCAD-PTS through a 395 nm filter and compared with an internal calibration curve, to provide a reading on the LED display that ranges from 0.05 Endotoxin Units (EU)/ml to 5 EU/ml. Several surface sites were analyzed within ISS between March 2007 and February 2008, including multiple locations in the US Laboratory Destiny, Node 1 Unity, AMock, and Service Module Zvezda. The goals of this initial study were to i) test the cleanliness of reagents/supplies on orbit, ii) test the crew's ability to collect and process a sample in microgravity without contamination, iii) demonstrate nominal function of the LOCAD-PTS, and iv) provide a general survey of endotoxin within the ISS. The surface sites varied greatly in terms of their frequency-of-use and material texture/composition; from relatively smooth aluminum, to fabric, to the room temperature vulcanizing (RTV) rubber of a Extravehicular Mobility Unit (EMU) spacesuit. Results showed that: i) the swabbing kits and reagents remained clean on orbit, ii) the crew could collect and process a sample without contamination, and iii) the LOCAD-PTS functioned nominally in > 99% of the 55 tests completed. We will present detailed results of the survey of endotoxin on ISS surfaces. These results and technology are important in the near-term - by providing an extra tool in the toolbox for ISS microbial monitoring. They are also important in the longer term as valuable preparation for human exploration of the Moon and Mars. One of the proposed science goals for the human exploration of Mars will be to detect and characterize any indigenous biological molecules that may exist on the Martian surface. To achieve that goal, the crew must have the technology available onboard to differentiate indigenous biology from any terrestrial biological material brought to Mars by the spacecraft and crew (termed 'forward contamination'). The LAL assay is already one of the official methods used by NASA's planetary protection program to certify cleanliness of interplanetary robotic spacecraft prior to launch; and therefore endotoxin is a good marker of forward contamination (as well as other microbial molecules detectable with LOCAD-PTS e.g. box-1, 3-glucan and lipoteichoic acid). Furthermore, the distribution and abundance of these molecules on the ISS provides a good indicator of what to expect on the Crew Exploratioehicle Orion, the lunar lander Antares, and future crewed spacecraft destined for Mars. In addition, technology such as LOCAD-PTS has been proposed to help evaluate forward contamination during lunar surface operations by the crew, as preparation for the human exploration of Mars.

Maule, J.↗

Metal-support interactions during the adsorption of CO on thin layers and islands of epitaxial palladium

Islands and continuous layers of palladium were grown in an ultrahigh vacuum on substrates of Mo(110)c(14 x 7)-O, designated MoO(x), and of clean Mo(110). It was found that as-deposited islands and layers exhibited bulk palladium adsorption properties for CO when deposited at room temperature and for palladium thicknesses in excess of about 3 monolayers. CO adsorption was drastically reduced, however, on annealing. For islands, annealing temperatures of as low as 400 K led to some reduction in CO adsorption whereas more severe reductions were found to occur at 600 K for islands and at 800 K for continuous multilayers. The deactivation depended on the palladium thickness, the substrate species and the extent of thermal treatments. Auger electron spectroscopy, temperature-programmed desorption and Delta-Phi measurements were combined to interpret the deactivation behavior in terms of substrate-support interactions involving the diffusion of substrate species towards the palladium surface.

Park, C.↗

Multifunction Vacuum Chamber for IC Metallization

Vacuum system chamber processing multilayer metallization on integrated circuits (IC's) performs four operations ordinarily done in separated equipment. Chamber etches holes, removes photoresist, cleans by sputter etching, and deposits final layer of metal. Combinedfunction chamber costs less than separate equipment. Chamber avoids exposing integrated circuits to room air and, to oxidation and dust, between steps. Eliminates time spent in transferring circuits from one apparatus to next.

Routh, D. E.↗

Test program, helium II orbital resupply coupling

The full scope of this program was to have included development tests, design and production of custom test equipment and acceptance and qualification testing of prototype and protoflight coupling hardware. This program was performed by Ball Aerospace Systems Division, Boulder, Colorado until its premature termination in May 1991. Development tests were performed on cryogenic face seals and flow control devices at superfluid helium (He II) conditions. Special equipment was developed to allow quantified leak detection at large leak rates up to 8.4 x 10(exp -4) SCCS. Two major fixtures were developed and characterized: The Cryogenic Test Fixture (CTF) and the Thermal Mismatch Fixture (Glovebox). The CTF allows the coupling hardware to be filled with liquid nitrogen (LN2), liquid helium (LHe) or sub-cooled liquid helium when hardware flow control valves are either open or closed. Heat leak measurements, internal and external helium leakage measurements, cryogenic proof pressure tests and external load applications are performed in this fixture. Special reusable MLI closures were developed to provide repeatable installations in the CTF. The Thermal Mismatch Fixture allows all design configurations of coupling hardware to be engaged and disengaged while measuring applied forces and torques. Any two hardware components may be individually thermally preconditioned within the range of 117 deg K to 350 deg K prior to engage/disengage cycling. This verifies dimensional compatibility and operation when thermally mismatched. A clean, dry GN2 atmosphere is maintained in the fixture at all times. The first shipset of hardware was received, inspected and cycled at room temperature just prior to program termination.

Hyatt, William S.↗

Experiments Advance Gardening at Home and in Space

Aeroponics, the process of growing plants suspended in air without soil or media, provides clean, efficient, and rapid food production. Crops can be planted and harvested year-round without interruption, and without contamination from soil, pesticides, and residue. Aeroponic systems also reduce water usage by 98 percent, fertilizer usage by 60 percent, and eliminate pesticide usage altogether. Plants grown in aeroponic systems have been shown to absorb more minerals and vitamins, making the plants healthier and potentially more nutritious. The suspended system also has other advantages. Since the growing environment can be kept clean and sterile, the chances of spreading plant diseases and infections commonly found in soil and other growing media are greatly reduced. Also, seedlings do not stretch or wilt while their roots are forming, and once the roots are developed, the plants can be easily moved into any type of growing media without the risk of transplant shock. Lastly, plants tend to grow faster in a regulated aeroponic environment, and the subsequent ease of transplant to a natural medium means a higher annual crop yield. For example, tomatoes are traditionally started in pots and transplanted to the ground at least 28 days later; growers using an aeroponic system can transplant them just 10 days after starting the plants in the growing chamber. This accelerated cycle produces six tomato crops per year, rather than the traditional one to two crop cycles. These benefits, along with the great reduction in weight by eliminating soil and much of the water required for plant growth, illustrate why this technique has found such enthusiastic support from NASA. Successful long-term missions into deep space will require crews to grow some of their own food during flight. Aeroponic crops are also a potential source of fresh oxygen and clean drinking water, and every ounce of food produced and water conserved aboard a spacecraft reduces payload weight, decreasing launch costs and freeing room for other cargo.

Source record↗

Low-pressure oxidation of Cb-1Zr alloy.

Resistively heated strip specimens of Cb-1Zr alloy were exposed at 927 C in a vacuum chamber at various levels of total pressure in the 1-microtorr range and at various oxygen partial pressures in the .1-microtorr range. Oxygen reaction rates (sticking probabilities) were found to depend on whether or not the specimens were annealed immediately before the test exposure. It is shown that a normally undetectable oxide film exists on the Cb-1Zr surface as a result of oxidation by ambient air, and this film reduces the sticking probability as compared with a clean metal surface. The alloy is considerably strengthened by addition of oxygen to a level of about 6000 ppm, while still maintaining reasonably good room temperature ductility.

Lyon, T. F.↗

Morphology and Luminescence Properties of Transition Metal Doped Zinc Selenide Crystals

Zinc selenide is an excellent matrix material to dope with rare-earth and transition metal to achieve mid-infrared luminescence to develop high power lasers. The luminescence, morphology and refractive index is significantly affected by the doping and defects generated due to size and valency of dopants, concentration, growth process and convection during the growth. The aim of the study is to investigate effect of point and line defects generated due to low doping of iron and chromium on the emission and morphology of the zinc selenide. Luminescence and morphological properties of large iron and chromium doped zinc selenide single crystals were studied to evaluate the effect of extremely low residual impurities and defects associated with the doping process. The emission properties following both short wavelength (i.e., ultraviolet; 350 – 370 nm) excitation and longer wavelength (i.e., near infrared; 850 – 870 nm) excitation were characterized. Luminescence emission bands were identified in both doped crystals. In addition to the primary emission bands, satellite peaks and intra-center transitions were also observed. Due to local population defects associated with the residual impurities (ppm to ppb) in the Fe-ZnSe and Cr-ZnSe crystals, peak emission wavelengths were observed to shift. Raman studies using 266 and 532 – nm excitation revealed different positions of longitudinal and transverse peaks for Fe-ZnSe and Cr-ZnSe crystals, associated with different levels of defects due to the different ion sizes. The emission bands were found to decrease in intensity due to recombination of residual impurity co-dopants and complex defects generated during growth and fabrication. Cryogenic temperature analyses revealed a very clean emission band due to freezing of some of the point and line defects. An emission band observed at 980 nm for both crystals at room temperature as well as cryogenic temperatures indicates a vibronic peak in ZnSe. The scanning electron microscopy (SEM) images of the local morphology support the conclusion that small crystallites in doped crystals are also present.

Zinc selenide↗

Adhesive Contact Sweeper

Adhesive contact sweeper removes hair and particles vacuum cleaner leaves behind, without stirring up dust. Also cleans loose rugs. Sweeper holds commercially available spools of inverted adhesive tape. Suitable for use in environments in which air kept free of dust; optics laboratories, computer rooms, and areas inhabited by people allergic to dust. For carpets, best used in tandem with vacuum cleaner; first pass with vacuum cleaner removes coarse particles, and second pass with sweeper extracts fine particles. This practice extends useful life of adhesive spools.

Patterson, Jonathan D.↗

Advancements in the modification of TiFe alloys for enhanced hydrogen Storage: Strategies and future Directions

Hydrogen is considered a promising clean energy source, and a potential alternative to conventional fossil fuels. TiFe alloy has been particularly interesting due to its ability to reversibly absorb and desorb hydrogen at room temperature and low pressure. The initial hydrogen absorption stage of TiFe alloy requires activation under high-temperature and high-pressure conditions, which hinders its practical application. Here, this paper primarily examines the impact of elemental substitution methods on the hydrogen storage capabilities of TiFe alloys, with a particular emphasis on elucidating the mechanisms associated with various substituent elements. Commonly utilized elements, such as Mn, V, and Zr, significantly improve the activation performance of TiFe alloys. Additionally, the incorporation of elements such as Ni, Cr, Ce, and Y contributes to the modulation of phase composition, as well as the enhancement of activation and kinetic properties. However, there exists a notable deficiency in systematic investigations concerning alternative elements, coupled with a frequent oversight of the preparation process's influence on the hydrogen storage characteristics of these alloys. Consequently, the mechanisms by which different elements affect the hydrogen storage process in TiFe alloys remain inadequately understood among current research, thereby complicating the establishment of experiment-based design guidelines for TiFe alloys. Furthermore, the plasma treatment and high-entropy alloying present new approaches for optimizing the hydrogen storage properties of TiFe alloys. This paper aims to present novel research perspectives and insights to scholars in the field by introducing methods for the modification of TiFe alloys.

Hydrogen storage↗

Auger electron spectroscopy and depth profile study of oxidation of modified 440C steel

Auger electron spectroscopy (AES) and sputtering were used to study selective oxidation of modified 440C steel. The sample was polycrystalline. Oxidation was performed on initially clean surfaces for pressures ranging from 1 x 10 to the minus 7th power to 1 x 10 to the minus 5th power torr and temperatures ranging from room temperature to 800 C. AES traces were taken during oxidation. In situ sputtering depth profiles are also obtained. A transition temperature is observed in the range 600 to 700 C for which the composition of the outer surface oxide changed from iron oxide to chromium oxide. Heating in vacuum about 5 x 10 to the minus 10 power torr to 700 C causes conversion of the iron oxide surface to chromium oxide.

Ferrante, J.↗

Tools Make Clean Holes In Honeycomb Panels

Three tools designed used together to prepare honeycomb panels for insertion of hardware to support structural members or electronic packages. Tools speed up and simplify time-consuming operation of manually pushing honeycomb material aside to make room for spool-shaped mounting insert. Tools are core cutter, spotface cutter, and displacement tool.

Wells, Dott↗

1016516285-AA - Handling Frame Assembly Table Structural and Seismic Analysis

Within the NIF (National Ignition Facility) sustainment project, LLNL is replacing all 1,728 blast shields with new ones. Before the new blast shield glass can be installed on NIF, it must pass through the AMOL (Amplifier Main Optics Loop). The AMOL process involves cleaning and coating the glass, assembling it into a Line Replaceable Unit (LRU), and performing testing and inspection. This work will be conducted in the OPFX cleanroom facility (Building 391, Room 1250) and requires several pieces of custom equipment. One key piece of equipment within the loop is the Handling Frame Assembly Table (see Figure 1.1). Its purpose is to assist operators in installing the blast shield glass into handling frames (1014442709) (see Figure 1.2). The table is also used to store handling frame assembly components. The primary components stored are the L-frames (1015208271), which are kept in a drawer underneath the table (see Figure 1.3). The purpose of this safety note is to ensure that the system does not pose a risk of injury to personnel during a seismic event. The system owner is OMST Engineering & Maintenance.

42 ENGINEERING↗

A study of the initial oxidation of evaporated thin films of aluminum by AES, ELS, and ESD

The room temperature, low pressure, oxidation of evaporated aluminum thin films has been studied by AES, ELS, and ESD. ESD was the most sensitive of the three methods to characterize a clean aluminum surface. Two oxidation stages were distinguished in the 0-3000 L oxygen exposure range. Between 0 and 50 L, the chemisorption of oxygen atoms was characterized by a fast decrease of the 67 eV AES Al peak and the 10 eV surface plasmon peak, and by a simultaneous increase of the oxygen AES and ESD signals. After 50 L, a change in slope in all AES and ESD signal variations was attributed to the slow growth of a thin layer of aluminum oxide, which after 3000 L was still only a few angstroms thick.

Bujor, M.↗

In-situ ellipsometric studies of optical and surface properties of GaAs(100) at elevated temperatures

A rotating-polarizer ellipsometer was attached to an ultrahigh vacuum (UHV) chamber. A GaAs(100) sample was introduced into the UHV chamber and heated at anumber of fixed elevated temperatures, without arsenic overpressure. In-situ spectroscopic ellipsometric (SE) measurements were taken, through a pair of low-strain quartz windows, to monitor the surface changes and measure the pseudodielectric functions at elevated temperatures. Real-time data from GaAs surface covered with native oxide showed clearly the evolution of oxide desorption at approximately 580 C. In addition, surface degradation was found before and after the oxide desorption. An oxide free and smooth GaAs surface was obtained by depositing an arsenic protective coating onto a molecular beam epitaxy grown GaAs surface. The arsenic coating was evaporated immediately prior to SE measurements. A comparison showed that our room temperature data from this GaAs surface, measured in the UHV, are in good agreement with those in the literature obtained by wet-chemical etching. The surface also remained clean and smooth at higher temperatures, so that reliable temperature-dependent dielectric functions were obtained.

Yao, Huade↗

Qualifications of Bonding Process of Temperature Sensors to Deep-Space Missions

A process has been examined for bonding a platinum resistance thermometer (PRT) onto potential aerospace materials such as flat aluminum surfaces and a flexible copper tube to simulate coaxial cables for flight applications. Primarily, PRTs were inserted into a silver-plated copper braid to avoid stresses on the sensor while the sensor was attached with the braid to the base material for long-duration, deep-space missions. A1-1145/graphite composite (planar substrate) and copper tube have been used in this study to assess the reliability of PRT bonding materials. A flexible copper tube was chosen to simulate the coaxial cable to attach PRTs. The substrate materials were cleaned with acetone wipes to remove oils and contaminants. Later, the surface was also cleaned with ethyl alcohol and was air-dried. The materials were gently abraded and then were cleaned again the same way as previously mentioned. Initially, shielded (silver plated copper braid) PRT (type X) test articles were fabricated and cleaned. The base antenna material was pretreated and shielded, and CV-2566 NuSil silicone was used to attach the shielded PRT to the base material. The test articles were cured at room temperature and humidity for seven days. The resistance of the PRTs was continuously monitored during the thermal cycling, and the test articles were inspected prior to, at various intermediate steps during, and at the end of the thermal cycling as well. All of the PRTs survived three times the expected mission life for the JUNO project. No adhesion problems were observed in the PRT sensor area, or under the shielded PRT. Furthermore, the PRT resistance accurately tracked the thermal cycling of the chamber.

Ramesham, Rajeshuni↗

An Overview of Renewable Energy Desk Activities for Power Grid Operations and Planning

This document summarizes how grid operators can address gaps in their planning and operations to maintain reliability as they pursue clean energy goals. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage variable renewable energy resource operation. Establishing such a desk in the control room can be a key step in the modernization effort. A renewable energy desk in a control room is a specialized hub focused solely on monitoring, predicting, and managing the influx of energy from renewable sources.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗