Engineering PapersSearch

SEARCH · Engineering Papers

Results for “high pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,272 records · Page 16

Thermodynamics of Tritium Trapping by Point Defects at Interfacial Cr-based Phases of the Al Coating

Density functional theory (DFT) simulations have been carried out to evaluate the potential for tritium trapping by metal vacancies in four phases Cr-containing phases (i.e., Cr3Si, Al0.3Cr0.7, Al8Cr5-HT, and Al8Cr5) identified near the interface between the Al coating and 316 stainless steel (316 SS) cladding. In addition, an ab initio thermodynamics approach has been employed to predict the temperature and T2-partial pressure dependence on the thermodynamics of singly tritiated defects. Key results in this work suggest that metal vacancies in the four phases have the potential to favorably trap tritium species, especially Si vacancies in Cr3Si phase. This overall thermodynamic trend can be correlated to the energy cost of having an interstitial tritium in the lattice, which has been calculated to range from 0.17 eV in Al8Cr5-HT to 0.89 eV in Cr3Si. A comparison of the results from this study with previous theoretical works investigating tritium behavior in other Fe-Al phases identified in the aluminide coating, suggests that metal vacancies are generally able to trap tritium in various Fe-Al aluminide phases. Especially, it was found that Si and Al vacancies would be the most efficient to trap for tritium, followed by Cr vacancies, then Fe and Ni vacancies. In the four Cr-based material phases investigated in this work, it is interesting to note that, in the absences of Fe or Ni species, strong interactions between tritium and the metal vacancies are always occurring by the formation of preferential Cr—T bonds (i.e., no Si—T or Al—T bonds were formed).

Sassi, Michel J.

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

thermal analysis

Predicting Operational Performance of xEMU Boot at Lunar South Pole Temperatures using Thermal Desktop ®

The spacesuit boots that will be used on Artemis lunar south pole surface missions will be exposed to extremely cold temperatures (down to ~50 K). To assess the performance of the government’s Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these permanently shadowed regions, testing was performed at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU CITADEL TVAC test. Expected thermal conductances within the boot and between the boot and environment were calculated from test data, which was then used as an initial guess for conductances within a Thermal Desktop (TD) model. Correlation of the TD model using the internal SOLVER feature was performed across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. Operational performance at the lunar south pole was then predicted using results from the correlated model. While the predictions provide evidence for acceptable performance of the boots at the 100K environment test point, there is still substantial uncertainty in performance, especially at the 48K test point. This uncertainty is due in part to testing limitations such as contacting the foot to a hard metal plate rather than granular regolith, and model limitations such as the lack of a realistic foot model. These limitations and their impacts are addressed in detail in this paper. The results of this test series and model correlation underscore the importance of additional improved testing and modeling for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

Spacesuit

Ammonolysis with N 2 -diluted NH 3 suppresses Ta( IV ) defects in BaTaO 2 N and enhances photocatalytic water oxidation

BaTaO 2 N stands out among oxynitride photocatalysts because of its ability to capture visible light and to drive the photoelectrochemical water oxidation reaction. However, its solar energy conversion performance is limited by electron–hole recombination at Ta( IV ) defects in the material. These defects are formed by overreduction of the Ta(v) oxide precursor by excess ammonia under the high temperature conditions during ammonolysis. Here we show for the first time that Ta( IV ) defect concentrations can be lowered by conducting the ammonolysis reaction in mixed NH 3 /N 2 gas. The obtained BaTaO 2 N samples crystallize in the cubic CaTiO 3 structure type and form 200–300 nm faceted nanocrystals, based on X-ray diffraction, scanning electron microscopy, and HRTEM. Electron paramagnetic resonance spectra observe the Ta( IV ) defects at g = 1.999 and confirm an 11-fold reduction for the product synthesized in mixed (0.13 : 1.0 vol) NH 3 /N 2 gas, equivalent to 1.14 × 10 16 cm −3 Ta( IV ) ions. This optimized BaTaO 2 N has nearly twice the photocatalytic oxygen evolution activity (AQE of 6.78% at 400 nm) of a reference material made with 1.0 atm ammonia and 78% higher photoelectrochemical water oxidation photocurrent (0.9 mA cm −2 at 1.23 V vs. RHE) under simulated sunlight. According to X-ray photoelectron spectroscopy, remaining Ta( IV ) defects are concentrated in the surface region of the BaTaO 2 N particles, where >50% of all Ta ions are found in the +4 oxidation state. This surface Ta( IV ) population can be directly observed in Vibrating Kelvin Probe Surface Photovoltage Spectra (VK-SPV) via its 1.2–1.4 eV photovoltage onset. Here, it suggests that the surface Ta( IV ) ions contribute empty d-states 0.5–0.7 eV below the BaTaO 2 N conduction band edge. These findings highlight how the energetics and concentrations of Ta( IV ) defects influence the photoelectrochemical water oxidation ability of BaTaO 2 N. Additionally, the work establishes ammonolysis with diluted NH 3 as a new tool to minimize defects in BaTaO 2 N and to raise its solar energy conversion efficiency toward its theoretical limit. Because of its simplicity, the reduced ammonia pressure strategy will likely be applicable to other oxynitrides, which generally suffer from overreduction problems during ammonolysis.

Salmanion, Mahya [University of California, Davis,

Trace benzene capture by decoration of structural defects in metal–organic framework materials

Abstract Capture of trace benzene is an important and challenging task. Metal–organic framework materials are promising sorbents for a variety of gases, but their limited capacity towards benzene at low concentration remains unresolved. Here we report the adsorption of trace benzene by decorating a structural defect in MIL-125-defect with single-atom metal centres to afford MIL-125-X (X = Mn, Fe, Co, Ni, Cu, Zn; MIL-125, Ti 8 O 8 (OH) 4 (BDC) 6 where H 2 BDC is 1,4-benzenedicarboxylic acid). At 298 K, MIL-125-Zn exhibits a benzene uptake of 7.63 mmol g −1 at 1.2 mbar and 5.33 mmol g −1 at 0.12 mbar, and breakthrough experiments confirm the removal of trace benzene (from 5 to <0.5 ppm) from air (up to 111,000 min g −1 of metal–organic framework), even after exposure to moisture. The binding of benzene to the defect and open Zn(II) sites at low pressure has been visualized by diffraction, scattering and spectroscopy. This work highlights the importance of fine-tuning pore chemistry for designing adsorbents for the removal of air pollutants.

Chemistry

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors

Thermally unstable roosts influence winter torpor patterns in a threatened bat species

Abstract Many hibernating bats in thermally stable, subterranean roosts have experienced precipitous declines from white-nose syndrome (WNS). However, some WNS-affected species also use thermally unstable roosts during winter that may impact their torpor patterns and WNS susceptibility. From November to March 2017–19, we used temperature-sensitive transmitters to document winter torpor patterns of tricolored bats (Perimyotis subflavus) using thermally unstable roosts in the upper Coastal Plain of South Carolina. Daily mean roost temperature was 12.9 ± 4.9°C SD in bridges and 11.0 ± 4.6°C in accessible cavities with daily fluctuations of 4.8 ± 2°C in bridges and 4.0 ± 1.9°C in accessible cavities and maximum fluctuations of 13.8 and 10.5°C, respectively. Mean torpor bout duration was 2.7 ± 2.8 days and was negatively related to ambient temperature and positively related to precipitation. Bats maintained non-random arousal patterns focused near dusk and were active on 33.6% of tracked days. Fifty-one percent of arousals contained passive rewarming. Normothermic bout duration, general activity and activity away from the roost were positively related to ambient temperature, and activity away from the roost was negatively related to barometric pressure. Our results suggest ambient weather conditions influence winter torpor patterns of tricolored bats using thermally unstable roosts. Short torpor bout durations and potential nighttime foraging during winter by tricolored bats in thermally unstable roosts contrasts with behaviors of tricolored bats in thermally stable roosts. Therefore, tricolored bat using thermally unstable roosts may be less susceptible to WNS. More broadly, these results highlight the importance of understanding the effect of roost thermal stability on winter torpor patterns and the physiological flexibility of broadly distributed hibernating species.

Biodiversity & Conservation

Amphiphilic nanopores that condense undersaturated water vapor and exude water droplets

Condensation of water vapor in confined geometries, known as capillary condensation, is a fundamental phenomenon with far-reaching implications. While hydrophilic pores enable liquid formation from undersaturated vapor without energy input, the condensate typically remains confined, limiting practical utility. Here, we explore the use of amphiphilic nanoporous polymer-infiltrated nanoparticle films that condense and release liquid water under isothermal and undersaturated conditions. By tuning the polymer fraction and nanoparticle size, we optimize condensation and droplet formation. As vapor pressure increases, voids fill with condensate, which subsequently exudes onto the surface as microscopic droplets. This behavior, enabled by a balance of polymer hydrophobicity and capillarity, reveals how amphiphilic nanostructures can drive accessible water collection. Our findings provide design insights for materials supporting energy-efficient water harvesting and heat management without external input.

Science & Technology - Other Topics

Fluidized Bed Gasification For Conversion of Biomass and Waste Materials to Renewable Hydrogen

This project was undertaken in order to study the potential for hydrogen production, at low cost, from mixtures of biomass and municipal solid waste (MSW). This approach allows for the production of hydrogen with a very low fossil carbon burden, while taking advantage of tipping fees (associated with MSW) to improved process economics. The team sourced three primary feedstocks (wood, MSW, and waste plastics) and characterized them comprehensively using established techniques with a long track record in the field of gasification. All three primary feedstocks were highly reactive and lost most of their mass during initial devolatilization. The production of tars, including heavy tars, was quite high, and was most problematic in the case of the MSW and Waste Plastics feedstocks. Little practical difference was identified between the MSW and Waste Plastics materials, and the addition of bed-forming materials (dolomite and brown alumina) to the feedstocks was found to reduce production of tars during devolatilization under thermogravimetric analysis and/or Fischer Assay conditions. A series of four tests in a lab-scale bubbling-fluidized-bed gasifier, at 50 psig of pressure and about 825 C, confirmed these findings. Pellet feedstocks, broken into fragments, were used for these tests, and pellets comprised of 50% MSW and 50% biomass were found to be the best option in terms of fossil carbon burden, economic potential, and gasification characteristics. Tests were then undertaken in a pilot-scale gasifier facility based on the GTI U-Gas fluidized-bed gasification technology. The feedstock handling train of the 20 TPD U-Gas pilot-scale gasifier located in Des Plaines, IL, was operated under simulated gasification conditions, and the 50/50 pellets were found to be very robust and unproblematic. An improved design for the forward end of the feedstock injection screw of the gasifier was developed and installed. The design approach was based on improved passive cooling of the front-most shroud at the end of the screw, since this approach was found in comprehensive modeling studies to be more than sufficient to accomplish the project objectives associated with this phase of the work, while also avoiding thermal gradients that could have caused heat-stress-induced damage to the refractory around the feedstock inlet if an active cooling approach had been applied. Careful technoeconomic analysis (TEA) of two possible 1000 TPD facilities was carried out. The TEA of conversion of MSW with corn stover in one case, and MSW with woody feedstock in the other case, showed that both had the potential to provide hydrogen at about $1/kg (minimum selling price, 2018 dollar basis). Of the two TEA cases, the one that was based on the conversion of wood in the southeastern USA was found to have slightly better economic potential. The other TEA case was based on a real location in Nebraska and called for corn stover feedstock conversion along with MSW. An underserved communities outreach program plan was developed in cooperation with personnel from the Nebraska Public Power District.

08 HYDROGEN

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION

Control of an Axisymmetric Jet Using Vortex Generators

The results of an experimental investigation on the effect of vortex generators, in the form of small tabs at the nozzle exit on the evolution of a jet, are reported in this paper. Primarily tabs of triangular shape are considered, and the effect is studied up to a jet Mach number of 1.8. Each tab is found to produce a dominant pair of counter-rotating streamwise vortices having a sense of rotation opposite to that expected from the wrapping of the boundary layer. This results in an inward indentation of the mixing layer into the core of the jet. A triangular-shaped tab with its apex leaning downstream, referred to as a delta tab, is found to be the most effective in producing such vortices, with a consequential large influence on the overall jet evolution. Two delta tabs, spaced 180 deg apart, completely bifurcate the jet. Four delta tabs stretch the mixing layer into four 'fingers,' resulting in a significant increase in the jet mixing downstream. For six delta tabs the mixing layer distortion settles back to a three finger configuration through an interaction of the streamwise vortices. The tabs are found to be equally effective in jets with turbulent or laminar initial boundary layers. Two sources of streamwise vorticity are postulated for the flow under consideration. One is the upstream 'pressure hill,' generated by the tab, which constitutes the main contributor of vorticity to the dominant pair. Another is due to vortex filaments shed from the sides of the tab and reoriented downstream by the mean shear of the mixing layer. Depending on the orientation of the tab, the latter source can produce a vortex pair having a sense of rotation opposite to that of the dominant pair. In the case of the delta tab, vorticity from the two sources add, explaining the strong effect in that configuration.

Streamwise Vorticity

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling

Validating a Dynamic PWR Safety and Security Model?

Nuclear power plants (NPPs) are assessed for safety and security using separate models that cannot capture how an attacker's decisions and a plant's response unfold together in real time, leaving regulators and operators without a complete picture of true plant vulnerability. Traditional probabilistic risk assessment (PRA) methods treat adversarial events as fixed initiators with predetermined outcomes, and are structurally incapable of representing the time-dependent interplay between physical security events, safety system response, and operator mitigative actions. At Idaho National Laboratory (INL), I contributed to the development and validation of Modeling and Analysis for Safety and Security using the Dynamic EMRALD Framework (MASS-DEF). Where static PRA relies on event-tree logic that cannot evolve mid-scenario, MASS-DEF couples a time-dependent dynamic PRA tool EMRALD (Event Modeling Risk Assessment using Linked Diagrams) with attack simulation software, allowing attacker behavior, plant system states, and operator actions to interact across time. My work focused on validating a general Pressurized Water Reactor (PWR) model. I traced model logic against PWR plant to identified errors in logic and confirm accuracy. I then built and tested attack scenarios against a general PWR model to verify that the model produced expected outcomes across all logical pathways. I also contributed a section to a related technical paper applying the same EMRALD platform to radiation dose modeling. Results show that MASS-DEF can quantitatively demonstrate that many plants exceed their regulatory security thresholds. This demonstrated margin provides a technically defensible basis for reducing the number of guards without compromising regulatory compliance. Physical security costs represent roughly 10% of annual operating budgets, making such reductions directly meaningful to INL's mission of sustaining existing commercial NPPs. This internship strengthened my understanding of nuclear systems, probabilistic modeling, and technical writing, and has solidified my pursuit of a career at a national laboratory.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)

Experimental Studies of Open Rotor Installation Effects

Open rotor propulsion technologies offer an opportunity for reducing fuel burn. At the same time, great challenges arise from this radically different engine architecture in terms of aircraft system integration. The aeroacoustic effects of integration are one of those key challenges and, furthermore, can offer the possibility for total aircraft system noise reduction. The inter-relationship of the aerodynamic and aeroacoustic system integration effects is particularly important to enable future application. An extensive model scale test campaign was conducted to investigate a broad range of these open rotor installation effects for both a conventional and an unconventional airframe. The experimental campaign was conducted in the Boeing Low Speed Aeroacoustic Facility with specially designed modifications for efficient positioning of the open rotor rig relative to the airframe. The airframe was traversed remotely relative to the fixed open rotor rig providing for the investigation of a large number of installation positions. Eight positions around the main wing of the conventional airframe and eleven positions above the hybrid wing body airframe were documented. Other parameters investigated in the test campaign included forward flight simulation Mach number, angle of attack, rotor speed, and airframe control surface deployment. In addition, both airframes were modified for alternate configurations. The conventional airframe was configured with both a T and a U tail while the unconventional hybrid wing body airframe was configured with different vertical control surfaces. An extensive instrumentation package was deployed. The acoustics were documented with a fixed array of far field microphones, a traversing array of in-flow microphones, an out-of-flow traversing phased array, and unsteady pressure transducers mounted flush on the surface of the airframes. In addition, mean flow surveys were measured with an articulating arm traversing system. The flow field surveys were particularly valuable in documenting flow distortion effects for the various installation positions and those created by angle of attack. This presentation will report the key results obtained for open rotor installation effects and discuss future prospects with the perspective of these results.

Michael J Czech

Revisiting the Soyuz-1 Parachute Failure in the Context of Safety in the Modern Era

The Soyuz‑1 accident remains one of the most consequential parachute related failures in human spaceflight history and provides enduring lessons for modern Entry, Descent, and Landing (EDL) system design. Occurring during the height of the Cold War and the Space Race, the mission unfolded under extraordinary political and schedule pressure as the Soviet Union sought to maintain its early leadership in space achievements following the death of chief designer Sergei Korolev. Despite unresolved propulsion, electrical, and parachute system deficiencies, Soyuz‑1 proceeded to launch and immediately encountered critical inflight anomalies, including a failed solar panel deployment, attitude control issues, and communication dropouts. Upon reentry, a malfunction in the parachute system, driven by a primary main canopy that failed to deploy, and subsequent entanglement of the reserve main canopy with the primary drogue parachute, resulted in insufficient deceleration and the fatal crash of cosmonaut Vladimir Komarov. Subsequent investigations revealed deep rooted cultural and organizational issues within the Soviet space program, including inadequate testing, suppression of dissent, undocumented last minute design changes, and the absence of integrated parachute system verification. More than 200 design flaws were identified after the accident, and firsthand accounts, including those from Yuri Gagarin, highlighted widespread concern prior to launch. Over time, the Soviet program implemented substantial reforms: systematic design corrections, rigorous process documentation, and an extensive series of drop tests that ultimately transformed the Soyuz system into one of the world’s most reliable human-rated return vehicles. This paper examines the technical architecture of the Soyuz‑1 parachute system, reconstructs the likely deployment sequence and failure mechanism, and analyzes the cultural contributors that shaped the accident. The study draws parallels to modern spacecraft parachute development, emphasizing the critical importance of integrated system testing, transparent engineering culture, and continuous hardware surveillance. These lessons remain directly relevant to today’s NASA and Commercial Crew Programs (CCP), where the Government continues to refine its understanding of aggregate risk and strengthen overall astronaut safety in the face of increasingly complex parachute systems.

Aaron L Morris