Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Aerosol Above Cloud Optical Depth in the Southeast Atlantic and Its Use in Continuity NASA Products

When aerosol overlie bright clouds, their radiative impact on the incident light can be either positive or negative. This difference in radiative impact promotes difficulties in remote sensing aerosol properties, which have shown biases in aerosol optical depth (AOD) retrievals when clouds are underneath. To better constrain this quantity, we have measured aerosols above clouds over the course of 3 years in the southeast Atlantic as part of the ObseRvations of CLouds above Aerosols and their intEractionS (ORACLES). These directly measured AOD above clouds are used to build and improve upon the current Near-Real-Time MODACAERO algorithm for above cloud AOD from MODIS, into a continuity product for NASA EOS/SNPP/JPSS. Here we present a summary of the above cloud aerosol optical depth measured during ORACLES, and that will be used for porting the MODACAERO algorithm to the continuity product. We use aerosol optical depth measured directly from sunlight attenuation using the Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) and compare it to the active remote sensing, High Spectral Resolution Lidar-2 (HSRL-2). We present a combination of all 3 years of measurements during peak biomass burning season. We have observed average above cloud aerosol optical depth at 500 nm ranging from 0.28 to 0.37, with the maximum in August 2017. We emphasize the use of improved aerosol absorption and scattering models based on airborne measurements during ORACLES.

aerosol optical depth (AOD)↗

Continuity of A Global, Satellite-Based Terrestrial Primary Productivity Dataset in the VIIRS Era Achieved With Model-Data Fusion

The NASA Terra and Aqua satellites have been successfully operating for over two decades and have far exceeded their original 5‐year design life. However, the era of NASA’s Earth Observing System (EOS) may be coming to a close as early as 2023. We conducted a comprehensive calibration and validation of the MODIS MOD17 product [1,2] and the potential for continuity of multi‐decadal ecosystem gross primary productivity (GPP) and annual net primary productivity (NPP), using data from the Visible Infrared Imaging Radiometer Suite (VIIRS) sensors aboard Suomi NPP and NOAA‐20. We combined an 18‐year record of eddy covariance flux tower measurements with hundreds of field measurements of NPP from the Oak Ridge National Laboratories Multi‐Biome collection to benchmark MODIS MOD17 Collection 6.1 (C61) and to develop the first terrestrial productivity estimates from VIIRS. Plant traits from the literature and the global TRY database [3,4] provide strong priors for identifying model parameters in a Bayesian model‐data fusion. As MODIS‐like observations are still needed for global environmental applications, the new VIIRS VNP17 product has the potential to extend these continuous estimates of global, terrestrial primary productivity beyond 2030.

K. Arthur Endsley↗

Comparison Between Continuous and Intermittent Actigraphy Outcomes During Long Duration Missions

Astronauts typically wear actigraphy watches continuously during their missions inflight. In late 2020, astronauts were scheduled to wear an actiwatch for one 2-week period every two months. Our aim was to compare sleep outcomes between data collected continuously vs intermittently to identify whether intermittently collected sleep data would yield similar results.

fatigue↗

Development of an Ultra-Low-Temperature 5-Stage Continuous Adiabatic Demagnetization Refrigerator That Provides Cooling at Two Unique Temperatures

The cryogenics group at NASA-Goddard has built several adiabatic demagnetization refrigerators (ADRs) for cooling detectors to sub-Kelvin temperatures in a lab, balloon, or space environment. The effort presented here describes the development of a new 5-stage adiabatic demagnetization refrigerator capable of providing continuous cooling at 35 mK with a cooling power double that previously demonstrated at this temperature. It will also provide a separate continuous temperature platform near 1 K. This system will be qualified using flight-like conditions, culminating in an ADR that is ready for the rigors of spaceflight by the end of the effort.

ADR↗

A New Model of Dry Firn Densification Constrained By Continuous Strain Measurements Near South Pole

Converting measurements of ice-sheet surface elevation change to mass change requires measurements of accumulation and knowledge of the evolution of the density profile in the firn. Most firn-densification models are tuned using measured depth-density profiles, a method which is based on an assumption that the density profile in the firn is invariant through time. Here we present continuous measurements of firn-compaction rates in 12 boreholes near the South Pole over a two-year period. To our knowledge, these are the first continuous measurements of firn compaction on the Antarctic Plateau. We use the data to derive a new firn-densification algorithm framed as a constitutive relationship. We also compare our measurements to compaction rates predicted by several existing firn densification models. Results indicate that an activation energy of 60 kJ mol (−1), a value within the range used by current models, best predicts the seasonal cycle in compaction rates on the Antarctic Plateau. Our results suggest models can predict firn-compaction rates with at best 7% uncertainty and cumulative firn compaction on a two year timescale with at best 8% uncertainty.

C. Max Stevens↗

Continuing Long-term Global SO 2 Data Record with JPSS OMPS Instruments

NASA’s long-term Earth Observing System (EOS) SO 2 climate data record (CDR) started with Aura/Ozone Monitoring Instrument (OMI, launched in 2004) and is now being continued with the SNPP/Ozone Mapping and Profiler Suite (OMPS, launched in 2011). Both OMI and SNPP/OMPS SO 2 CDRs are produced with the Goddard principal component analysis (PCA) spectral fitting algorithm. By inherently accounting for various instrumental factors, the PCA technique enables highly consistent retrievals between different instruments. In this presentation, we will provide an overview on our effort to further extend the EOS SO 2 CDR, by implementing the PCA SO 2 algorithm with multiple OMPS instruments flying on the Joint Polar Satellite System (JPSS) constellation, including NOAA-20 (launched in 2017) and NOAA-21 (launched in 2022). We will present results analyzing our new NOAA-20/OMPS PCA SO 2 EOS continuity product, to be publicly released in fall of 2023. We will show statistical analyses on the quality of NOAA-20 PCA SO 2 product, such as retrieval noise, biases over background areas, and long-term stability. We will employ a previously established top-down method to estimate SO2 emissions from selected large point sources, using NOAA-20 SO 2 retrievals and assimilated wind fields as input. The SO 2 emission estimates derived from NOAA-20 retrievals will be compared with those from OMI, SNPP/OMPS, and S5P/TROPOMI (TROPOspheric Monitoring Instrument). We will also demonstrate the application of a new machine learning technique that further reduces the noise of NOAA-20 SO 2 retrievals. Finally, we will present preliminary PCA SO 2 retrievals from recently launched satellite sensors, including NOAA-21/OMPS and NASA’s geostationary TEMPO (Tropospheric Emissions: Monitoring of Pollution) instrument.

SO2↗

Calibration of the SNPP and NOAA 20 VIIRS Sensors for Continuity of the MODIS Climate Data Records

Accurate long-term sensor calibration and periodic re-processing to ensure consistency and continuity of atmospheric, land and ocean geophysical retrievals from space within the mission period and across different missions is a major requirement of climate data records. In this work, we applied the Multi-Angle Implementation of Atmospheric Correction (MAIAC)-based vicarious calibration technique over Libya-4 desert site to perform calibration analysis of Visible Infrared Imaging Radiometer Suite (VIIRS) on Suomi National Polar-orbiting Partnership (SNPP) and NOAA-20 satellites. For both VIIRS sensors we characterized residual linear calibration trends and cross-calibrated both sensors to MODerate resolution Imaging Spectroradiometer (MODIS) Aqua regarded as a calibration standard. The relative spectral response (RSR) differences were accounted for using the German Aerospace Center (DLR) Earth Sensing Imaging Spectrometer (DESIS) hyperspectral surface reflectance data. Our results agree with independent vicarious calibration results of both the MODIS/VIIRS Characterization Support Team as well as the CERES Imager and Geostationary Calibration Group within estimated uncertainty of 1–2%. Analysis of MAIAC geophysical products with the new calibration shows a high level of agreement of MAIAC aerosol, surface reflectance and NDVI records between MODIS and VIIRS. Excluding high aerosol optical depth (AOD), all three sensors agree in AOD with mean difference (MD) less than 0.01 and residual mean squared difference rmsd ∼ 0.04. Spectral geometrically normalized surface reflectance agrees within rmsd of 0.003–0.005 in the visible and 0.01–0.012 at longer wavelengths. The residual surface reflectance differences are fully explained by differences in spectral filter functions. Finally, difference in NDVI is characterized by rmsd ∼ 0.02 and MD less than 0.003 for NDVI based on VIIRS imagery bands I1/I2 and less than 0.01 for NDVI based on VIIRS radiometric bands M5/M7. In practical sense, these numbers indicate consistency and continuity in MAIAC records ensuring the smooth transition from MODIS to VIIRS.

MAIAC↗

Retrieval of Aerosol Optical Properties From GOCI-II Observations: Continuation of Long-Term Geostationary Aerosol Monitoring Over East Asia

Since the Geostationary Ocean Color Imager (GOCI) was successfully launched in 2010, the GOCI Yonsei aerosol retrieval (YAER) algorithm has been continuously updated to retrieve hourly aerosol optical properties. GOCI-II has 4 more channels including UV, finer spatial resolution (250 m), and daily full disk coverage as compared to GOCI, and was launched in February 2020, onboard the GEO-KOMPSAT-2B (GK-2B) satellite. In this study, we extended the YAER algorithm to GOCI-II data based on its improved performance in many aspects and present the first results of aerosol optical properties retrieved from GOCI-II data. Utilizing the overlapping period between the GOCI-II and GOCI in geostationary Earth orbit, we present GOCI-II aerosol retrievals for high aerosol-loading cases over East Asia and show that these have a consistent spatial distribution with those from GOCI. Furthermore, GOCI-II provides AOD at an even higher spatial resolution, revealing finer changes in aerosol concentrations. Validation results for one year data show that the GOCI-II AOD has a correlation coefficient of 0.83 and a ratio within the expected error (EE) of 59.4 % when compared with the aerosol robotic network (AERONET) data. We compared statistical metrics for the GOCI and GOCI-II AODs to assess the consistency between the two datasets. In addition, it was found that there is a strong correlation between the two datasets from the comparison of gridded GOCI and GOCI-II AOD products. It is expected that data from GOCI-II will continue long-term aerosol records with high accuracy that can be used to address air-quality issues over East Asia.

AOD↗

Coordinated continual planning methods for cooperating rovers

This paper compares and contrasts several coordination schemes for a system that continuously plans to control collections of rovers (or spacecraft) using collective mission goals, instead of goals or command sequences for each spacecraft.

continual planning rovers multiple agents↗

Simulations of Continuous Descent Operations with Arrival-management Automation and Mixed Flight-deck Interval Management Equipage

Air traffic management simulations conducted in the Airspace Operations Laboratory at NASA Ames Research Center have addressed the integration of trajectory-based arrival-management automation, controller tools, and Flight-Deck Interval Management avionics to enable Continuous Descent Operations (CDOs) during periods of sustained high traffic demand. The simulations are devoted to maturing the integrated system for field demonstration, and refining the controller tools, clearance phraseology, and procedures specified in the associated concept of operations. The results indicate a variety of factors impact the concept's safety and viability from a controller's perspective, including en-route preconditioning of arrival flows, useable clearance phraseology, and the characteristics of airspace, routes, and traffic-management methods in use at a particular site. Clear understanding of automation behavior and required shifts in roles and responsibilities is important for controller acceptance and realizing potential benefits. This paper discusses the simulations, drawing parallels with results from related European efforts. The most recent study found en-route controllers can effectively precondition arrival flows, which significantly improved route conformance during CDOs. Controllers found the tools acceptable, in line with previous studies.

arrival management↗