Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Effective Doses in Four-Dimensional Computed Tomography for Lung Radiotherapy Planning

The recent broad adoption of 4-D computed tomography (4DCT) scanning in radiotherapy has allowed the accurate determination of the target volume of tumors by minimizing image degradation caused by respiratory motion. Although the radiation exposure of the treatment beam is significantly greater than that of CT scans used for treatment planning, it is important to recognize and optimize the radiation exposure in 4DCT from the radiological protection point of view. Here, radiation exposure in 4DCT was measured with a 16 multidetector CT. Organ doses were measured using thermoluminescence radiation dosimeter chips inserted at respective anatomical sites of an anthropomorphic phantom. Results were compared with those with the helical CT scan mode. The effective dose measured for 4DCT was 24.7 mSv, approximately four times higher than that for helical CT. However, the increase in treatment accuracy afforded by 4DCT means its use in radiotherapy is inevitable. The patient exposure in the 4DCT could be of value by clarifying the advantage of the treatment planning using 4DCT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of x-ray microfocus computed tomography as an imaging tool for porous structures

X-ray microfocus computed tomography (micro-CT) is recently put forward to qualitatively and quantitatively characterize the internal structure of porous materials. However, it is known that artifacts such as the partial volume effect are inherently present in micro-CT images, thus resulting in a visualization error with respect to reality. This study proposes a validation protocol that in the future can be used to quantify this error for porous structures in general by matching micro-CT tomograms to microscopic sections. One of the innovations of the protocol is the opportunity to reconstruct an interpolated micro-CT image under the same angle as the physical cutting angle of the microscopic sections. Also, a novel thresholding method is developed based on matching micro-CT and microscopic images. In this study, titanium porous structures are assessed as proof of principle. It is concluded for these structures that micro-CT visualizes 89% of the total amount of voxels (solid and pore) correctly. However, 8% represents an overestimation of the real structure and 3% are real structural features not visualized by micro-CT. When exclusively focusing on the solid fraction in both the micro-CT and microscopic images, only an overestimation of about 5% is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data fusion in neutron and X-ray computed tomography

We present a fusion methodology between neutron and X-ray computed tomography (CT). On the one hand, the inspection by X-ray CT of a wide class of multimaterials in non-destructive testing applications suffers from limited information of object features. On the other hand, neutron imaging can provide complementary data in such a way that the combination of both data sets fully characterizes the object. In this contribution, a novel data fusion procedure, called Fusion Regularized Simultaneous Algebraic Reconstruction Technique, is developed where the X-ray reconstruction is modified to fulfill the available data from the imaging with neutrons. The experiments, which were obtained from an aluminum profile containing a steel screw, and attached carbon fiber plates demonstrate that the image quality in CT can be significantly improved when the proposed fusion method is used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-dose computed tomography image restoration using previous normal-dose scan

Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use of the previous normal-dose scan via the presented ndiNLM algorithm is noticeable as compared to a similar approach without using the previous normal-dose scan. Conclusions: For low-dose CT image restoration, the presented ndiNLM method is robust in preserving the spatial resolution and identifying the low-contrast structure. The authors can draw the conclusion that the presented ndiNLM algorithm may be useful for some clinical applications such as in perfusion imaging, radiotherapy, tumor surveillance, etc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Motion-map constrained image reconstruction (MCIR): Application to four-dimensional cone-beam computed tomography

Purpose: Utilization of respiratory correlated four-dimensional cone-beam computed tomography (4DCBCT) has enabled verification of internal target motion and volume immediately prior to treatment. However, with current standard CBCT scan, 4DCBCT poses challenge for reconstruction due to the fact that multiple phase binning leads to insufficient number of projection data to reconstruct and thus cause streaking artifacts. The purpose of this study is to develop a novel 4DCBCT reconstruction algorithm framework called motion-map constrained image reconstruction (MCIR), that allows reconstruction of high quality and high phase resolution 4DCBCT images with no more than the imaging dose as well as projections used in a standard free breathing 3DCBCT (FB-3DCBCT) scan.Methods: The unknown 4DCBCT volume at each phase was mathematically modeled as a combination of FB-3DCBCT and phase-specific update vector which has an associated motion-map matrix. The motion-map matrix, which is the key innovation of the MCIR algorithm, was defined as the matrix that distinguishes voxels that are moving from stationary ones. This 4DCBCT model was then reconstructed with compressed sensing (CS) reconstruction framework such that the voxels with high motion would be aggressively updated by the phase-wise sorted projections and the voxels with less motion would be minimally updated to preserve the FB-3DCBCT. To evaluate the performance of our proposed MCIR algorithm, we evaluated both numerical phantoms and a lung cancer patient. The results were then compared with the (1) clinical FB-3DCBCT reconstructed using the FDK, (2) 4DCBCT reconstructed using the FDK, and (3) 4DCBCT reconstructed using the well-known prior image constrained compressed sensing (PICCS).Results: Examination of the MCIR algorithm showed that high phase-resolved 4DCBCT with sets of up to 20 phases using a typical FB-3DCBCT scan could be reconstructed without compromising the image quality. Moreover, in comparison with other published algorithms, the image quality of the MCIR algorithm is shown to be excellent.Conclusions: This work demonstrates the potential for providing high-quality 4DCBCT during on-line image-guided radiation therapy (IGRT), without increasing the imaging dose. The results showed that (at least) 20 phase images could be reconstructed using the same projections data, used to reconstruct a single FB-3DCBCT, without streak artifacts that are caused by insufficient projections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Computational Corrections to X-Ray Computed Tomography for Dimensional Metrology of Complex Additively Manufactured Parts

X-ray computed tomography (CT) is a nondestructive evaluation technique that may be used to image complex internal features without the line-of-sight restrictions inherent in conventional optical and contact (stylus) metrology instrumentation. Applications of CT metrology include material defects (porosity), dimensions and surface texture. However, scan artifacts, such as streaking, caused primarily by beam hardening and scatter, limit the accuracy of CTbased metrology. Reduction of these artifacts would improve the accuracy material properties and dimensional metrology information. This paper reports on the development of additively manufactured (AM) Ti5553 and 316L measurement phantoms with integral lattice (lattice) structures specifically designed to exhibit these artifacts. The phantoms were scanned in three CT systems and a scanning-probe CMM measurement. Surfaces generated from uncorrected CT data exhibited “dimple” defects that are not present in the CMM measurement. Correction methods were developed in Livermore Tomography Tools (LTT) software and this paper reports on the successful correction of these artifacts. This work is expected to have application in areas where characterization of defects, dimensions and surface texture using CT are critical.

42 ENGINEERING↗

Computed Tomography Scanning and Petrophysical Measurements of Oriskany Core across Eastern Ohio

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core material from three Ohio wells. These wells are listed below along with their American Petroleum Institute (API) and Ohio Geological Survey (OGS) identification numbers: - New York Central System 1 well (API 34085200170000, OGS Core 855) - Herren Well (API 34099201650000, OGS Core 2914) - Garvin-King Well (API 34121215610000, OGS Core 2939) The primary impetus of this work was to capture a detailed digital representation of the available core from all three wells. The collaboration between the U.S. Department of Energy’s (DOE) NETL and the Ohio Department of Natural Resources, Division of Geological Survey enables other research entities to access information about this potential carbon storage location and its surrounding formations.

58 GEOSCIENCES↗

Development of Proton Computed Tomography for Applications in Proton Therapy

Determination of the Bragg peak position in proton therapy requires accurate knowledge of the electron density and ratio of effective atomic number and mass (Z/A) of the body tissues traversed. While the Z/A ratio is fairly constant for human tissues, the density of tissues varies significantly. One possibility to obtain accurate electron density information of tissues is to use protons of sufficient energy to penetrate the patient and measure their energy loss. From these transmission measurements, it is possible to reconstruct a three-dimensional map of electron densities using algebraic techniques. The interest in proton computed tomography (pCT) has considerably increased in recent years due to the more common use of proton accelerators for cancer treatment world-wide and a modern design concept based on current high-energy physics technology has been suggested. This contribution gives a status update on the pCT project carried out by the pCT Collaboration, a group of institutions sharing interest and expertise in the development of pCT. We will present updated imaging data obtained with a small pCT prototype developed in collaboration with the Santa Cruz Institute of Particle Physics and installed on the proton research beam line at Loma Linda University Medical Center. We will discuss hardware decisions regarding the next-generation pCT scanner, which will permit scanning of head-sized objects. Progress has also been made in the formulation of the most likely path of protons through an object and parallelizable iterative reconstruction algorithms that can be implemented on general-purpose commodity graphics processing units. Finally, we will present simulation studies for utilizing pCT technology for on-line proton dose verification and tumor imaging with positron emission tomography (PET)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Soft-Tissue Contrast in Four-Dimensional Computed Tomography Images of Liver Cancer Patients Using a Deformable Image Registration Method

Purpose: To investigate a deformable image registration method to improve soft-tissue contrast in four-dimensional (4D) computed tomography (CT) images of the liver. Methods and Materials: Ten patients with hepatocellular carcinoma underwent 4D CT scan for radiotherapy treatment planning on a positron emission tomography/CT scanner. Four-dimensional CT images were binned into 10 equispaced phases. The exhale phase served as the reference phase, and images from the other nine phases were coregistered to the reference phase image using an intensity-based, automatic deformable image registration method. Then the coregistered images were combined to create a single, high-quality reconstructed CT image at exhale phase as the new reference for target delineation. The extent of image quality enhancement was quantified relative to the original CT by calculating the signal-to-noise ratio and the contrast-to-noise ratio. Results: The soft tissue image contrast was noticeably better after deformable image registration than in the original scans. Signal-to-noise ratios inside the liver region of interest increased for all patients by a factor of 3.0 (range, 2.3-3.7). The improvement in image quality was not linearly proportionate to the number of images averaged. Using only 6 phases can achieve at least 85% of the contrast enhancement that can be achieved using all 10 phases. We also found that contrast enhancement was inversely proportional to the original image quality (p = 0.006), and the contrast enhancement is attained with little loss of spatial resolution. Conclusions: This deformable image registration method is feasible to improve soft-tissue image quality in 4D CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Computed Tomography of Mock Uranium Fuel Rods at the Advanced Photon Source

This study discusses a multi-year effort to evaluate the utility of computed tomography at the Advanced Photon Source (APS) as a tool for non-destructive evaluation of uranium based fuel rods. The majority of the data presented is on mock material made with depleted uranium which mimics the x-ray attenuation characteristics of fuel rods while allowing for simpler handling. A range of data is presented including full thickness (5mm diameter) fuel rodlets, reduced thickness (1.8mm) sintering test samples, and pre/post irradiation samples (< 1mm thick). These data were taken on both a white beam (bending magnet) beamline and a high energy, monochromatic beamline. This data shows the utility of a synchrotron type source in the evealuation of manufacturing defects (pre-irradiation) and lays out the case for in situ CT of fuel pellet sintering. Finally, in addition data is shown from small post-irradiation samples and a case is made for post-irradiation CT of larger samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method

Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold-standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x-ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root-mean-square difference of around 2.4%. It was found that the discrete ordinates method, with a higher order of Legendre polynomial expansions, underestimated the absorbed dose near the center of the phantom (i.e., low dose region). Simulations of the quadrature set 8 and the first order of the Legendre polynomial expansions proved to be the most efficient computation method in the authors’ study. The single-thread computation time of the deterministic simulation of the quadrature set 8 and the first order of the Legendre polynomial expansions was 21 min on a personal computer. Conclusions: The simulation results showed that the deterministic method can be effectively used to estimate the absorbed dose in a CTDI phantom. The accuracy of the discrete ordinates method was close to that of a Monte Carlo simulation, and the primary benefit of the discrete ordinates method lies in its rapid computation speed. It is expected that further optimization of this method in routine clinical CT dose estimation will improve its accuracy and speed.

07 ISOTOPE AND RADIATION SOURCES↗

Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated Image Segmentation and Processing Pipeline Applied to X–Ray Computed Tomography Studies of Pitting Corrosion in Aluminum Wires

Understanding pitting corrosion is critical, yet its kinetics and morphology remain challenging to study from X-ray computed tomography (XCT) due to manual segmentation barriers. To address this, an automated pipeline leveraging deep learning for efficient large-scale XCT analysis is developed, revealing new corrosion insights. The pipeline enables pit segmentation, 3D reconstruction, statistical characterization, and a topological transformation for visualization. Here, the pipeline is applied to 87 648 XCT images capturing commercial purity aluminum (1100 Al) wire exposed to sodium chloride (NaCl) salt particles over a period of 122 h. The pipeline achieves complete feature extraction and statistical quantification across the entire XCT dataset, leveraging distributed computing environment for high efficiency. Global growth kinetics such as high-level stepwise sigmoidal volume loss patterns and granular individual pit developments are both captured for 36 detected pits. By combining automation, computer vision, and extensive XCT datasets, this research accelerates precise corrosion assessment to enable materials science discoveries at scale.

36 MATERIALS SCIENCE↗

The application of synchrotron micro-computed tomography to characterize the three-dimensional microstructure in irradiated nuclear fuel

This research demonstrated the first time that synchrotron X-ray micro-computed tomography (μ-CT) was utilized to analyze the three-dimensional (3-D) morphology of the microstructure of irradiated nuclear fuel. Both absorption contrast and propagation-based phase contrast enhanced μ-CT techniques were evaluated. Porosity and phase region volumes were determined in neutron irradiated uranium 10 wt.% zirconium (U-10Zr) using propagation-based phase contrast enhanced μ-CT. Volumes were determined by image processing software and algorithms, with the porosity volume subsequently compared to the ASTM E562 method. The 3-D porosity of a small region (~ 8 x 10 5 µm 3 ) located in the intermediate fuel redistribution zone that was removed via a focused ion beam was determined to be 7.2% via image processing. A detailed 3-D analysis of the porosity with respect to volume and morphology was provided. Five growth stages of pore evolution were observed including: nucleation, growth, coalescence, interconnected porosity, and extended/interconnected porosity. Four distinct phase regions were identified, including the pores, via both absorption contrast and propagation-based phase contrast enhanced μ-CT. A quantitative comparison of fuel swelling between this localized microscopic U-10Zr fuel region, previously irradiated in the Fast Flux Test Facility, and historic U-10Zr fuels irradiated in the Experimental Breeder Reactor-II (EBR-II) was conducted. It was determined that for similar burnups, the localized swelling in this microscopic fuel region was 7.7%, which was approximately one-half of the value of the macroscopic swelling reported in EBR-II irradiated fuel. With the advent of new specimen preparation tools for irradiated materials, as well as advances in characterization techniques, researchers can now obtain previously inaccessible microstructural insight into irradiated fuels. This possibility naturally lends itself to improved fuel performance models for the nuclear community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computed Tomography Scanning and Geophysical Measurements of Core from the Boggess 17H Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize the Marcellus Shale and underlying formations. The core is from a vertical pilot well (Boggess 17H) drilled in western Monongalia County near Core, West Virginia by Northeast Natural Energy for the second Marcellus Shale Energy and Environmental Laboratory (MSEEL). MSEEL is a joint venture between NETL, Northeast Natural Energy, and West Virginia University. The primary impetus for this report is to characterize the core to better understand the structure and variation of the Marcellus Shale and surrounding formations. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis.

58 GEOSCIENCES↗

Renal solitary fibrous tumor/hemangiopericytoma: computed tomography findings and clinicopathologic features

Purpose: To retrospectively characterize the clinical, pathological, and computed tomography (CT) findings of renal solitary fibrous tumor/hemangiopericytoma (rSFT/HPC). Methods: Twelve patients with rSFT/HPCs were enrolled. The CT findings and clinicopathological features were retrospectively reviewed. Results: This study included six male and six female patients (median age: 47; age range: 20–82 years). Eight benign (grade I) and four malignant (grade III) rSFT/HPCs were identified. Of the 12 lesions, 10 were in the renal sinus near the renal pelvis, while two replaced the whole kidney. Five lesions were well-defined, five were partially ill-defined, and two were ill-defined. Mild (5/12) and intermediate (1/12) hydronephrosis was observed. On the unenhanced CT images, ten tumors showed slightly higher density when compared to the normal renal parenchyma, and two masses were isodense to hypodense. After intravenous contrast medium injection, three enhancement patterns were observed, including “prolonged enhancement” (PE) (6/12), “gradual enhancement” (4/12), and “early washout” (2/12). A central fibrous scar was found in five patients. Compared to the grade I lesions, the grade III rSFT/HPC lesions tended to be larger (maximal diameter > 10 cm) and more heterogeneous with a higher incidence of the PE pattern. Conclusions: We have shown that rSFT/HPCs usually arise from the renal sinus, and present as lobulated, slightly hyperdense, gradually enhancing soft tissue masses. CT findings, including large size, heterogeneity, and the PE pattern, may assist in the pre-operative identification of malignant grade III rSFT/HPCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interobserver agreement of computed tomography reporting standards for chronic pancreatitis

Aim: To assess the interobserver agreement of computed tomography (CT) reporting standards for chronic pancreatitis (CP). Subjects and methods: Retrospective analysis of CT of 47 patients (33 males and 11 females, age range 36 to 56 years) with CP who presented with abdominal pain (n = 41), steatorrhea (n = 37), and glucose intolerance (n = 31). The patients underwent CT study using a 16-multidetector CT scanner with a pancreatic protocol including a nonenhanced scan followed by pancreatic phase at 35 s and portal venous phase at 65 s after intravenous injection of nonionic contrast medium. Image analysis was performed by two radiologists according to reporting standards for CP. Results: There was excellent interobserver agreement (84.8 %) between the two reviewers in CT reporting standards for CP (K = 0.80, 95 % CI 0.75–0.85, P = 0.001). There was good interobserver agreement for pancreatic duct (PD) caliber (K = 0.71, 95 % CI 0.56–0.87, P = 0.001), PD contour (K = 0.76, 95 % CI 0.61–0.91, P = 0.001), PD stricture (K = 0.070, 95 % CI 0.53–0.88, P = 0.001), and distribution of findings (K = 0.69, 95 % CI 0.51–0.86, P = 0.001). There was excellent interobserver agreement for intraductal calculi (K = 0.84, 95 % CI 0.68–0.98, P = 0.001), pancreatic calcifications (K = 0.86, 95 % CI 0.84–0.98, P = 0.001), and pancreatic diameter (K = 0.87, 95 % CI 0.75–0.99, P = 0.001). Conclusion: CT reporting standards for CP is a reliable method for diagnosis of patients with CP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗