Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Experimental Investigation of a Phase Change Material Charged Finned-Tube Heat Exchanger

Understanding different thermal performance aspects of phase change material heat exchangers (PCM-HX) is critical for designing future energy-efficient thermal energy storage systems. This paper presents an experimental performance analysis of a vertically oriented annular finned-tube PCM-HX in a cylindrical container tested under six different melting and solidification test conditions, varied by heat transfer fluid’s (HTF) inlet temperatures and flow directions. The PCM-HX structure with 20 evenly spaced fins was 3D printed in aluminum, and the PCM-HX container was 285 mm in height. The PCM-HX average porosity was 89.7%, where the PCM mass was 246.4 g. Water served as the HTF, and a PCM with a nominal phase change temperature of 35 °C was selected. Instead of opaque conventional insulation sheets, a combination of air-and-argon-filled see-through insulation cylinders was assembled with the PCM-HX to visualize the phase-change phenomena, while minimizing the uncertainties due to heat loss. In total, there were 78 T-type thermocouples installed in the test section which allows a more precise assessment of thermal mass and heat loss, which are often neglected in similar studies found in the literature. We validated the reliability of the test facility as the repeated test results had negligible deviations under the same test conditions. The energy balances between the estimated theoretical and experimentally calculated PCM storage, considering heat loss and thermal mass, were within ±9% deviation for all test conditions. From the experimental investigations, we made several following observations. It was found that the melting pattern of the finned-tube PCM-HX with small gaps between the container wall and the fins was largely affected by the HTF flow directions, unlike the typical straight annular tube PCM-HX. For effective charging and discharging processes, a combination of upward melting and downward solidification is recommended to shorten the test duration. However, an upward solidification should be considered to minimize the cavity formation between the fins caused by the PCM volume contraction during the solidification process.

25 ENERGY STORAGE↗

Development and Experimental Optimization of High-Temperature Modeling Tools and Methods for Concentrated Solar Power Particle - Systems

A novel, open-source radiative modeling toolset was developed to extend the functionality of particle-based modeling software (e.g. discrete element method (DEM)) to environmental conditions relevant to concentrated solar power applications. This toolset was optimized for deployment on desktop workstations instead of high-performance computing systems, to render such tools more accessible to the research community. Both particle-based modeling and radiative exchange modeling are computationally expensive and often require specialized programming expertise, making these methods cumbersome to use. Recent developments in DEM software by DCS Computing have greatly reduced these challenges, providing a graphical-user-interface based platform and modeling optimization for desktop workstations, HPCs, and cloud computing. The University of Dayton leveraged the experience of DCS Computing in developing a user-friendly, open-source radiative heat transfer expansion for DEM modeling. The University of Dayton DEM+ radiative modeling toolset was developed using a combination of fundamental experimental measurements, modeling, and simplified flow experiments over a range of temperatures and flow conditions. The toolset provides researchers with access to multiple radiative models including an accelerated Monte-Carlo Ray Tracing (application agnostic, highly computationally expensive), an expanded database of distance-based approximations (application limited, computationally light), and a weighted blending of the two methods capable of achieving over 90% reduction in computation time with equivalent accuracy compared to Monte-Carlo Ray Tracing. Through a graphical user interface, users can customize the radiative models to match their desired accuracy and available computational resources, improving access to particle based modeling for the research community. Ceramic sintered bauxite proppants were used in modeling and experimentally as a baseline. Both the radiative heat transfer and flow properties for particulate systems were investigated at elevated temperatures up to 800 °C. The major accomplishments for this work include a verified, open-source radiative modeling toolset to be distributed amongst the research community and the fabrication of three small-scale test facilities to investigate particle behavior and tune DEM flow properties for operation up to 800 °C. The findings have been shared with the research community via conference modeling workshops, deployment of the tools in DCS Computing Aspherix®, and open-source access to the developed radiative modeling tool. The development of next-generation CSP facilities and thermal energy storage systems based on ceramic particles requires providing access to computationally efficient and accurate modeling tools. Particles will experience a wide range of environments (20-800 °C) and handling conditions (dilute curtains or dense packing), requiring specially designed and optimized equipment. Optimizing solid particle physics models and establishing best-practices for particle modeling in CSP environments will assist researchers with designing optimized equipment, accelerating the deployment of more economically-competitive CSP facilities.

14 SOLAR ENERGY↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

A ranking methodology for the coupling of pressurized water nuclear reactors and molten salt thermal energy storage

Thermal energy storage (TES) systems are a proposed solution to electricity market demand fluctuations and can be coupled to nuclear power plants to enable load following. Here, this work focuses on developing a methodology for evaluating potential designs for integrating a TES system into an existing pressurized water nuclear power plant. The proposed ranking methodology allows a group of experts to postulate and weigh designs based on ranking criteria derived from literature. The methodology developed in this study can aid in the final selection of a TES design for an existing nuclear power plant. The same process could be used to analyze other TES and nuclear reactor designs. The determined optimum design from this methodology was to place the TES system after the steam generator and to utilize the steam generated from the nuclear power plant to heat a molten salt TES unit. Another conclusion of this research was that human bias is prevalent during design selection, and actions such as standardized ranking criteria and large groups of experts should be used to minimize this error.

25 ENERGY STORAGE↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of future energy demand increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can reduce the grid stress for improving the resilience of the grid. The integration of renewable power and storage has several significant and positive impacts including expanding the renewable energy portion of electricity generation, meeting peak-load demand, and coordinating supply and demand. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Thermal energy storage (TES) has the ability to store a large capacity of energy with improved site flexibility compared to incumbent LDES technologies (i.e., pumped hydro) and has attracted significant interest. Our development in TES technology using solid particles as the storage medium has shown feasibility and potential in serving LDES purposes. Particle TES has various advantages over commercialized molten nitrate salt TES and has emerged as a promising storage technology originating from Generation 3 concentrating solar power (CSP) development. Stable, inexpensive silica sand produced in the Midwestern U.S. was identified as a suitable storage medium and has been validated through lab heating and cycling tests. We have successfully developed particle TES for bidirectional electric energy storage to broaden the applications for TES beyond CSP technologies and into standalone electric-thermal energy storage (ETES) systems. Key component designs and performance were verified with prototype testing and model simulations. The ETES system uses high-temperature, low-cost particle thermal energy storage coupled with a unique pressurized fluidized bed heat exchanger that supports a high-efficiency, air-Brayton combined power cycle. At times of low energy demand or high renewable production, an electric particle heater heats large quantities of solid particles to high temperatures in excess of 1100 degrees C. The particles are stored in internally insulated silos. At times of high electricity demand, the hot particles are gravity-fed through the heat exchanger where stored thermal energy is transferred to the power cycle working fluid to drive the gas turbine power generation system, thereby converting the thermal energy back into electricity for the grid. The cold particles leaving the heat exchanger are returned to the storage silos by a well-insulated particle conveyor. This ETES technology using particle TES can be sited anywhere and is predicted to be economic and efficient. Moreover, this ETES technology could be co-located with a retired coal or gas plant to leverage existing power generation and grid infrastructure. Our work has focused on the development of each of the key components (e.g., the electric particle heater, particle storage silos, and the particle-to-gas pressurized fluidized bed heat exchanger) through conceptual designs, prototype testing, and computational modeling. These developments demonstrate technological feasibility and are an important step towards the next phase of development of this promising LDES technology. This presentation will show the progress in developing a pilot demonstration of the ETES system on a commercially relevant scale.

25 ENERGY STORAGE↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Evaluation of Effective Thermal Conductivity of PCM with Metal Foam Incorporating Buoyancy Effects for Thermal Energy Storage

The thermal energy storage (TES) system has the capability to efficiently preserve thermal energy directly derived from the energy source, minimizing any conversion losses. Especially latent heat storage offers distinct advantages, including a substantial increase in energy storage density and minimization of temperature fluctuations within the plants. However, the phase change material (PCM) employed in latent heat storage has low thermal conductivity. Consequently, various studies are being conducted to enhance heat transfer. One approach to enhance heat transfer involves utilizing metal foam to maximize the heat transfer area. However, modeling metal foam with its intricate structure is a challenging task in numerical analysis. For this reason, ongoing research focuses on simplifying the modeling of metal foam. Nevertheless, fully encompassing all the characteristics of actual metal foam proves to be a challenging task for the simplified analytical model. The objective of this paper is to interpret the simple lattice metal foam analysis model from the perspective of behavior induced by buoyancy. When comparing the analysis results of solid PCM and liquid PCM with the same thermal conductivity under changes in porosity and gravity direction, we conducted an analysis to discern the trends in effective thermal conductivity that are overestimated due to convection. In the analysis, a constant heat flux of 10 kW and a constant surface boundary condition of 350 K were applied, and a sensitivity study regarding the mesh was conducted. The results indicate that, from the perspective of gravity in the simple lattice model, the solid analysis yields an effective thermal conductivity 29-47% higher compared to the liquid analysis. Additionally, as porosity increases, there is an observed increase of 24-33% in effective thermal conductivity.

25 ENERGY STORAGE↗

Techno-Economic Analysis of Recuperated Joule-Brayton Pumped Thermal Energy Storage

This article describes a techno-economic model for pumped thermal energy storage systems based on recuperated Joule-Brayton cycles and two-tank liquid storage. Models have been developed for each component, with particular emphasis on the heat exchangers. Economic metrics such as the power and energy capital costs (i.e., per-kW and per-kWh capacity) and levelized cost of storage are evaluated by gathering numerous cost correlations from the literature, thereby enabling estimates of uncertainty. It is found that the use of heat exchangers with effectivenesses up to 0.95 is economically worthwhile, but higher values lead to rapidly escalating component size and system cost. Several hot storage fluids are considered; those operating at the highest temperatures (chloride salts) improve the round-trip efficiency but the benefit is marginal and may not warrant the additional material costs and risk when compared to lower-temperature nitrate salts. Cost-efficiency trade-offs are explored using a multi-objective optimization algorithm, yielding optimal designs with round-trip efficiencies in the range 59-72% and corresponding levelized storage costs of 0.12 0.03 and 0.38 0.10 $/kWhe. Lifetime costs are competitive with lithium-ion batteries for discharging durations greater than 6 h under current scenarios.

Carnot battery↗

Performance Investigation of High-temperature Latent Heat Storage for Integration with Advanced Nuclear Reactors

Integrating thermal energy storage (TES) with advanced nuclear reactors enhances the flexible use of nuclear energy, facilitating its expansion beyond conventional electricity generation. High-temperature TES, capable of storing heat above 400 degree C, emerges as a vital carbon-free energy solution for decarbonizing industrial sector, especially when combined with low-emission energy sources like advanced nuclear reactors. Idaho National Laboratory (INL) has recently developed a novel design for high-temperature latent heat storage system, called Heat pipe Integrated Thermal Battery (HITB), and efforts are underway to experimentally demonstrate the concept. HITB employs liquid-metal heat pipes to establish thermal linkage between TES and nuclear systems without direct fluid exchange, minimizing the potential risk of the integrated systems such as cross-contamination. HITB is designed to achieve high charging and discharging efficiency as well as high energy storage density by employing metal alloys as Phase Change Material (PCM). Initial proof-of-concept experiments are being undertaken using an aluminum alloy (Al59%-Mg35%-Zn6%). This paper discusses current progress of the HITB project at INL, seeking to develop high-temperature TES for versatile integration with advanced nuclear reactors, and shares insights from the performance evaluations via numerical modeling and analysis.

25 ENERGY STORAGE↗

Temperature effects on adsorption and capillarity water retention mechanisms in constrained unsaturated soils

Abstract This paper focuses on the impact of elevated temperatures on the adsorptive and capillarity water retention mechanisms of unsaturated soils under constrained (constant volume) conditions. This topic is critical for simulating the thermo-hydraulic behavior of soils in hydrogeological or geotechnical applications, including climate change effects on near surface soils, energy piles or soil borehole thermal energy storage systems in unsaturated soil layers, and buffers for geological nuclear waste repositories. A nonisothermal soil water retention curve (SWRC) that separately considers the temperature-dependency of the key parameters governing adsorptive and capillarity water retention mechanisms and soil physical parameters (e.g., surface tension, contact angle, adsorption capacity, cation exchange capacity, mean cavitation suction, air entry value and equilibrium film thickness) was developed to provide insights into the impact of temperature on water retention over the full suction range. The nonisothermal SWRC was validated using experimental data on high plasticity clays, with a good prediction of temperature effects on adsorption and capillarity water retention mechanisms in constrained unsaturated soils.

Lu, Yu↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of moderate temperatures on compressive strength of ultra-high-performance concrete: A microstructural analysis

Highlights: • All coarse aggregates and steel fibres were surrounded by the binder. • X-ray diffraction is useful for explaining the increase in compressive strength with increasing temperature. • Rosenhahnite and/or quartz Dauphiné-twinned phases improved the compressive strength. • Polypropylene fibres prevented spalling and preserved the compressive strength. • Concrete with steel and polypropylene fibres did not exhibit spalling at 300 °C. Concrete with two types of steel fibres and a polypropylene fibre prevented spalling and preserved the compressive strength at 300 °C, which makes these concretes suitable for long-term applications up to 300 °C, such as for steam collectors or thermal energy storage systems. The compressive strength behaviour of three types of ultra-high-performance fibre-reinforced concrete manufactured with the same matrix was investigated. For this purpose, a complete characterisation of all the raw materials and the three types of fibres used was performed. The morphology of all concrete mixtures at room temperature was analysed using scanning electron microscopy–energy-dispersive X-ray spectroscopy. From the results, it was ascertained that the steel fibres and coarse siliceous aggregates were not in contact (being separated by ≥3.41 μm) and were surrounded by the binder (of ≥1 μm in thickness) for all the mixtures studied. Rosenhahnite and/or quartz Dauphiné-twinned phases improved the compressive strength (as determined by X-ray diffraction).

36 MATERIALS SCIENCE↗

Minimizing grid energy consumption in wastewater treatment plants: Towards green energy solutions, water sustainability, and cleaner environment

Wastewater treatment plants (WWTPs) consume significant amount of energy to sustain their operation. From this point, the current study aims to enhance the capacity of these facilities to meet their energy needs by integrating renewable energy sources. The study focused on the investigation of two primary solar energy systems in As Samra WWTP in Jordan. The first system combines parabolic trough collectors (PTCs) with thermal energy storage (TES). This system primarily serves to fulfill the thermal energy demands of the plant by reducing the demands from boiler units, which allows more biogas for electricity generation. The second system is a photovoltaic (PV) system with Lithium-Ion batteries, which directly produces electricity that will be used to cover part of the electrical energy demands of plant. To assess the optimal configuration, two distinct scenarios have been formulated and compared to the current case scenario (SC#1). The first scenario focuses on maximizing the net present value (NPV) and minimizing the levelized cost of electricity (LCOE). The second scenario is centred on minimizing the levelized cost of heat (LCOH). The findings indicate that both scenarios succeeded in reducing the reliance on the grid to a value that reach 1 %. Moreover, they both reduced biogas percentage in energy production from 88 % to approximately 65 % through the integration of the PV system. In terms of thermal demand, SC#2 reduced the reliance on biogas boiler units from 100 % to 25 %, while SC#3 achieved an even more impressive reduction to just 8 %. The best LCOE value was attained in SC#2, at 0.0895 USD/kWh, with an NPV of 10.54 million USD. Conversely, SC# 3 yielded an LCOH value of 0.0432 USD/kWh th compared to 0.0534 USD/kWh th USD for SC#2. In conclusion, despite their relatively high capital and operating costs, SC#2 and SC#3 managed to substantially decrease the annual electricity expenditure from approximately 2 million USD to 86,000 USD and 0 USD, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced power density in zero-vacuum-gap thermophotovoltaic devices

Thermophotovoltaic (TPV) devices, which convert infrared thermal radiation from a hot emitter into electricity, hold great promise for applications in energy storage and waste heat recovery. While recent advancements have developed TPV devices with high efficiency, much less attention has been focused on improving the power density. Current TPV methods face challenges in significantly boosting the power density using emitters at very high temperatures (>2000 °C) or using complex, costly architectures such as near-field TPV. Here, we present the first experimental demonstration of a novel far-field TPV concept called “zero-vacuum-gap TPV” that eliminates the vacuum or gas-filled gap in conventional designs. By incorporating a high-index, infrared-transparent, and thermally insulating fused quartz spacer, we achieved a two-fold increase in power density compared to the far-field counterpart under identical conditions. Notably, in our experiment, the zero-vacuum-gap far-field design transforms a less-optimized, low-power-density far-field device into one with one of the highest power densities reported at moderate temperatures (700–1100 °C). Moreover, our measurements using a graphite emitter surpass the blackbody limit for gap-integrated far-field devices and match the performance of near-field TPV devices with an ultrathin 200-nm gap. Our findings suggest that zero-vacuum-gap TPV offers potential for cost-effective, scalable manufacturing using current technologies. Additionally, our modelling predicts that further power enhancements over one order of magnitude are possible with other spacer materials.

14 SOLAR ENERGY↗

Molten Salt vs. Liquid Sodium Receiver Selection Using the Analytic Hierarchy Process

An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ degrees C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process (AHP) to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six- month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two- tank chloride salt thermal energy storage system.

analytic hierarchy process↗