Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Physical Security Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Cyber and Physical Security Analysis of GSI and Noventum Application for IoT Communications

We present our findings of the red team exercise conducted on the device and application developed by Guardian Sensors, Inc. (GSI) and Noventum. The app is used for situational awareness and control of photovoltaics (PV) and microgrid energy systems. The assessments performed are practical case scenarios that assess the risks and vulnerabilities posed by the app through targeted activities that could be engaged by an adversary. The assessment team’s results and recommendations are provided to inform on and mitigate the identified weaknesses to improve secure user authentication, connections, and communications. The recommendations in this report are not intended to be a security panacea but will add the desired defense-in-depth layer to securing communication of such interconnected systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Flux Isotope Reactor Low-Enriched Uranium High Density Silicide Fuel Preliminary Design Update: System Transient Analysis

As a part of conversion efforts from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel under direction of the National Nuclear Security Administration of the U.S. Department of Energy, multiple proposed designs of the High Flux Isotope Reactor (HFIR) have been created and assessed regarding reactor physics performance metrics, including designs utilizing uranium silicide dispersion fuel (U3Si2-Al). This report updates the previous analyses that evaluated the nuclear safety performance of LEU fuel designs with respect to selected accident events from the HFIR Safety Analysis Report (SAR). Both the Low Density (LD) and High Density (HD) Optimized designs’ reactivity initiated accident fuel performance improved relative to the HEU fuel, attributed to greater 238 U negative Doppler feedback. However, the thermal margins for primary coolant system accidents were reduced with some acceptance criteria unable to be met. The need to resolve reduced thermal margin, open modeling items, and unresolved assumptions was identified.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Chemical Management System (CMS): A Useful Tool for Inventory Management

Comprehensive inventory management is central to the efficient operation of any facility that uses and stores chemicals. There are numerous software packages available that perform this function satisfactorily. Most commercially available inventory management software is regulatory or procurement focused and usually comes with upfront or monthly fees. Finally, this report describes freely downloadable software developed at Sandia National Laboratories that delivers an effective inventory management system with an additional focus on chemical security.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science↗

Modularization of Small Modular Reactor Facilities: Physical Protection Recommendations

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping costs reasonable to make nuclear energy competitive. In consideration of the economic viability of small modular reactor (SMR) facilities, many designers and utilities are considering a modular approach to the construction and operation of these facilities. This modular approach considers building and operating a first unit; once the first reactor is in operation, construction will begin on a second reactor. This process would allow the vendor or utility to ensure production of energy and financial income while the second reactor is under construction. This project evaluates the feasibility of modular construction in terms of physical protection and identifies several recommendations for vendors and utilities considering this approach. To conduct this evaluation, a hypothetical three-unit SMR facility was developed, a physical protection system (PPS) was considered for the design, and a hypothetical design basis threat (DBT) was used to evaluate this PPS. Multiple outsider sabotage scenarios were examined, with adversary team sizes ranging from 4-to-8 to determine security system effectiveness. The results of this work will influence PPS designs and facility designs for U.S. domestic SMRs. This work will also demonstrate how a series of experimental and modeling capabilities across the Department of Energy (DOE) complex can impact the design and completion of security-by-design (SeBD) for SMRs considering modular construction. The conclusions and recommendations in this document may be applicable to all SMR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Independent Review of the Proof-of-Concept Cyber100 Compass Cybersecurity Risk Tool

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), and Office of Electricity (OE) commissioned the National Renewable Energy Laboratory (NREL) to develop a method and tool to enable electric utilities to understand and manage the risk of cybersecurity events that can lead to physical effects like blackouts. This tool, called Cyber100 Compass, uses cybersecurity data elicited from cybersecurity experts, then incorporates that data into a tool designed to be usable by cybersecurity non-experts who understand the system itself. The tool estimates dollar-valued risks for a current or postulated future electric power digital control configuration, in order to enable utility risk planners to prioritize among proposed cybersecurity risk mitigation options. With the development of the Cyber100 Compass tool for quantification of future cyber-physical security risks, NREL has taken an initial bold step in the direction of enabling and indeed encouraging electric utilities to address the potential for cybersecurity incidents to produce detrimental physical effects related to electric power delivery. As part of the Cyber100 Compass development process, DOE funded NREL to seek out an independent technical review of the risk methodology embodied in the tool. NREL requested this review from Sandia National Laboratories, and made available to Sandia a very late version of the project report, as well as NREL personnel to provide clarification and to respond to questions. This paper provides the result of the independent review activity.

97 MATHEMATICS AND COMPUTING↗

eMosaic: Electrification Mosaic Platform for Grid Informed Smart Charging Management (Final Scientific/Technical Report)

ABB (Prime Contractor), in collaboration with its partners at the Utah State University (USU), Idaho National Laboratory, Rocky Mountain Power (RMP), and Electric Power Engineers (EPE), have performed research, development, and wide scale demonstration of a scalable and resilient Electrification Mosaic (eMosaic) platform for Smart Charge Management (SCM) for Electric Vehicle Infrastructure. Work was completed under DE EE0009194, titled “eMosaic Electrification Mosaic Platform for Grid Informed Smart Charging Management”, funded by the US Department of Energy. The project members developed algorithms that provide localized and bulk grid services and that reduce and stabilize costs all the way down the supply chain to the PEV owner through SCM. This platform aggregates telemetry from multiple data sources as pieces of the larger picture including personal, private fleet or transportation EVs, fast chargers and other supply equipment, weather service information, and geographically distributed charging sites such as public lots, garage and retail, and private or shared usage depots. ABB and the project team designed, tested, and improved a charging management system at local/edge and cloud levels. The ultimate objective of the project was to convincingly demonstrate that the developed secure eMosaic plat-form can be readily and favorably adopted by diverse utilities and site owners at scale. This was achieved through a demonstration plan with field deployment at several physical sites across 4 states and additional scalable simulation from high fidelity charging models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantum Key Distribution for Critical Infrastructures: Towards Cyber-Physical Security for Hydropower and Dams

Hydropower facilities are often remotely monitored or controlled from a centralized remote control room. Additionally, major component manufacturers monitor the performance of installed components, increasingly via public communication infrastructures. While these communications enable efficiencies and increased reliability, they also expand the cyber-attack surface. Communications may use the internet to remote control a facility’s control systems, or it may involve sending control commands over a network from a control room to a machine. The content could be encrypted and decrypted using a public key to protect the communicated information. These cryptographic encoding and decoding schemes become vulnerable as more advances are made in computer technologies, such as quantum computing. In contrast, quantum key distribution (QKD) and other quantum cryptographic protocols are not based upon a computational problem, and offer an alternative to symmetric cryptography in some scenarios. Although the underlying mechanism of quantum cryptogrpahic protocols such as QKD ensure that any attempt by an adversary to observe the quantum part of the protocol will result in a detectable signature as an increased error rate, potentially even preventing key generation, it serves as a warning for further investigation. In QKD, when the error rate is low enough and enough photons have been detected, a shared private key can be generated known only to the sender and receiver. We describe how this novel technology and its several modalities could benefit the critical infrastructures of dams or hydropower facilities. The presented discussions may be viewed as a precursor to a quantum cybersecurity roadmap for the identification of relevant threats and mitigation.

97 MATHEMATICS AND COMPUTING↗

Capabilities for Water Sector Infrastructure Resilience - Prioritizing RD&D in a Target Rich, Resource Poor Sector

WSTB & Water Sector Security Program Expansion Objective: Incubate and shepherd a public-private consortium of joint seal US government sponsors and industry stakeholders to build out industrial control system (ICS) and operational technology (OT) architecture of the Idaho National Laboratory (INL) Water Security Test Bed (WSTB) asset to enable research, testing, and cyber workforce training related to evolving cyber-physical and physical vulnerabilities and threats in the water sector.

99 - GENERAL AND MISCELLANEOUS↗

Systems Engineering Approach for Design and Implementation of a Gas Breech for Actinide Experiments at the JASPER Facility

The Joint Actinide Shock Physics Experimental Research (JASPER) Facility is located approximately 65 miles north of Las Vegas, Nevada at the Nevada National Security Site (NNSS). The primary mission is to conduct shock physics research on actinide materials in support of NNSA’s Stockpile Stewardship Program. JASPER experiment uses a two-stage light gas gun to accelerate projectiles into targets at velocities up to 8 km/s (17,000 mph). The first stage uses an ignited propellent to drive a piston to compress gas in the pump tube. At the second stage, the gas compression exceeds a specified pressure and a rupture valve at the end of the pump tube opens. This launches a projectile to impact the target. The target is housed inside the target assembly and the debris field is contained inside the primary target chamber (PTC). The PTC is placed inside the secondary confinement chamber (SCC) as an added protection against possible contamination. These major components are illustrated in Figure 1.JASPER is capable of generating and measuring data on the properties of radioactive chemical elements at high shock pressures, temperatures, and strain rates approximating the conditions in nuclear weapons by using a two-stage gas gun. The data is used to determine material equations-of-state and validate computer models of material response. The work advances predictive capability, thus ensuring confidence in the nuclear stockpile.

42 ENGINEERING↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

IAEA ITC28 Project Report. 28th International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities

Sandia National Laboratories (SNL) has hosted the International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities since 1978. This course is the flagship training course of the International Atomic Energy Agency (IAEA). On behalf of the National Nuclear Security Administration (NNSA), SNL manages, develops, and coordinates all course materials, and works closely with the IAEA to arrange all logistical details for the course. ITC-28 incorporated several new approaches based on feedback and experience with ITC-27 and earlier versions of the course. For ITC-28, an addition to the Integrated Security Facility (ISF) at SNL was a mock reactor hall with a mock reactor pool. Other facilities at the ISF include a mock processing facility, material receiving area, and central alarm station. The physical protection system at the ISF—an area that formerly housed Category I nuclear material—provides many opportunities for hands-on, real world training in the design and evaluation of a physical protection system (PPS). This document provides a brief description of ITC-28, including a summary of lessons learned and key recommendations for future development efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of mechanochemical interactions of hydrogen with earth materials in a subsurface gas storage

The goal of this project is to investigate the molecular interactions of H 2 with earth materials (EMs) that may potentially affect economics and safety of H 2 geological storage (HGS). We investigated (1) the H 2 intercalation into interlayers of phyllosilicates, (2) the competitive adsorption of H 2 /CH 4 onto porous materials, and (3) solubility of H 2 in interfacial and confined hydrocarbons. Our results indicate that (i) H 2 intercalation into hydrated interlayers is thermodynamically unfavorable and H 2 solubility in hydrated clay interlayers is in the same order of magnitude as that in bulk water, (ii) CH 4 outcompetes H 2 in adsorption onto kerogen, due to stronger CH 4 -kerogen interactions than H 2 -kerogen interactions, (iii) H 2 tends to dissolve more in oil than in water, and the introduction of CO 2 as a cushion gas reduces H 2 partitioning near the kaolinite surfaces. The outcomes provide foundational knowledge for preparing the USA for future storage site selection and storage system design, supporting DOE missions in clean and secured energy.

08 HYDROGEN↗

Are Satellites Cyber Physical Systems?

Abstract— Cyber-physical systems (CPS) are a key part of modern infrastructure. However, satellites are often excluded from discussions of CPS, despite their evident cyber-physical attributes, such as the ability to respond to information from its surroundings and adjust accordingly. Through a brief examination of relevant literature, we prove that satellites are CPSs, specifically through payload-bus interactions that occur on a satellite. By establishing satellites as a form of CPS, we hope to encourage its inclusion in discussions for bettering the security of such systems.

Jones, Rachel C.↗

ARCADE Technical Pathway and Industry Impact

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) simplifies the evaluation and assessment of robustness factor and cyber resilience that support secure-by-design for advanced reactor nuclear power plants. In this manner, ARCADE supports risk-informed performance based (RIPB) evaluations of cybersecurity through its integration of plant physics with high-fidelity emulations of control systems. This cross domain approach enables comprehensive analysis of control system sensitivities, cyber-attack scenarios, and their consequences. ARCADE has been custom developed to meet the demands identified in Tier 1 of the Tiered Cyber Analysis (TCA) as outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors.

97 MATHEMATICS AND COMPUTING↗

Cybersecurity Assessment Tools for Distributed Energy Resources

This growing number of smart devices that support DERs can increase the number of access points outside a utility’s administrative domain, which can increase the potential for cyberattack. With the integration of DERs at federal sites, the cybersecurity vulnerabilities of DER systems must be understood and addressed. This presentation covers two NREL tools available. The Distributed Energy Resource Cybersecurity Framework (DER-CF) is a web-based holistic tool for evaluating cybersecurity posture including governance, physical security and technical management. The Distributed Energy Resource Risk Manager (DER-RM) extends the DER-CF by applying it to the NIST risk management framework process. It will be downloadable application that runs locally and documents all the major requirements for achieving Authority to Operate the DER.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Research on Integrated Energy Systems Cyber Range

As digital technologies expand to meet the needs of a more autonomous, interconnected, and advanced power system, new cybersecurity complexities and vulnerabilities arise. The ARIES Cyber Range enables the energy sector to evaluate these evolutions and validate cybersecurity solutions without impacting live systems. Combining power grid-scale hardware with emulation and simulation approaches, the ARIES Cyber Range can faithfully replicate modern energy systems - from grid physics to communication networks, and everything in between - with real-world fidelity. At NLR, researchers and partners are answering complex power system cybersecurity questions, examining emerging threats to the electric sector, and de risking new security technologies, all at a mission-relevant speed that keeps pace with rapidly evolving systems and hazards.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗