Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Multimodal Instrument Concepts for Chemical Sciences at Second Target Station

The development of advanced chemical and energy systems is inherently complex, relying heavily on their unique pathways. Because no two catalysts or batteries follow exactly the same kinetic trajectories, conventional sequential measurements often obscure crucial relationships between structure and dynamics through statistical averaging. This report introduces two neutron scattering instrument concepts for the Second Target Station (STS) specifically designed to overcome this barrier: the Extended Q-range Diffractometer (EQD) and the Multimodal Chemical Spectrometer (MCS).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cryogenic Instrumentation at ProtoDUNE

The cryogenic instrumentation of ProtoDUNE successfully operated during the first run of the experiment, providing a comprehensive monitoring of the cryostats, the cryogenics system and the detectors. It includes devices to measure the liquid argon level, the electron lifetime, the temperature of the liquid and gas argon, the pressure inside the cryostat and the contamination of the gas argon, as well as cameras to inspect the most critical detector elements. These systems and their performance are reviewed, and a few aspects of their future upgrade discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preventing Bio-Bloopers and XFEL Follies: Best Practices from your Friendly Instrument Staff

Serial Femtosecond Crystallography (SFX) at X-ray Free electron Lasers (XFELs) is a relatively new field promising to deliver unparalleled spatial and temporal resolution on biological systems and there dynamics. Over the past decade, though, there have been a handful of results that have truly delivered on these promises. Why? SFX has many paradigm shifting techniques not seen in typical structural biology arenas, such as creating a concentrated slurry of microcrystals rather than a handful of loopable prisms worthy of a catalog photo. Then taking that slurry and high speed jetting them towards the vacuum or helium interation region to destroy less than 1% of your sample and waste the other 99. The literature is full of techniques and methods promising to cure what ails your experiment, yet as an instrument scientist will tell you –and a first author might admit after a few drinks at the conference happy hour—is that there are a lot more failures than the success we published, results may vary. We will walk through a best practices on how to prepare your sample and chose a sample delivery technique that will amerliorate your studies rather than undermine your hardwork and hopefully lead to better experimental planning and execution, inching you closer to that scientific goal and that call from Stockholm. This will be written in a more editorialized fashion and is meant to give the reader an idea of what to try or how they should be thinking. Welcome to SFX, now what?

47 OTHER INSTRUMENTATION↗

The Target-selection Pipeline for the Dark Energy Spectroscopic Instrument

Abstract In 2021 May, the Dark Energy Spectroscopic Instrument (DESI) began a 5 yr survey of approximately 50 million total extragalactic and Galactic targets. The primary DESI dark-time targets are emission line galaxies, luminous red galaxies, and quasars. In bright time, DESI will focus on two surveys known as the Bright Galaxy Survey and the Milky Way Survey. DESI also observes a selection of “secondary” targets for bespoke science goals. This paper gives an overview of the publicly available pipeline ( desitarget ) used to process targets for DESI observations. Highlights include details of the different DESI survey targeting phases, the targeting ID ( TARGETID ) used to define unique targets, the bitmasks used to indicate a particular type of target, the data model and structure of DESI targeting files, and examples of how to access and use the desitarget code base. This paper will also describe “supporting” DESI target classes, such as standard stars, sky locations, and random catalogs that mimic the angular selection function of DESI targets. The DESI target-selection pipeline is complex and sizable; this paper attempts to summarize the most salient information required to understand and work with DESI targeting data.

47 OTHER INSTRUMENTATION↗

Astrometric Calibration and Performance of the Dark Energy Spectroscopic Instrument Focal Plane

Abstract The Dark Energy Spectroscopic Instrument, consisting of 5020 robotic fiber positioners and associated systems on the Mayall telescope at Kitt Peak, Arizona, is carrying out a survey to measure the spectra of 40 million galaxies and quasars and produce the largest 3D map of the universe to date. The primary science goal is to use baryon acoustic oscillations to measure the expansion history of the universe and the time evolution of dark energy. A key function of the online control system is to position each fiber on a particular target in the focal plane with an accuracy of 11 μ m rms 2D. This paper describes the set of software programs used to perform this function along with the methods used to validate their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Fiber Positioning Accuracy and Throughput with Fiber Dithering for the Dark Energy Spectroscopic Instrument

Highly multiplexed, fiber-fed spectroscopy is enabling surveys of millions of stars and galaxies. The performance of these surveys depends on accurately positioning fibers in the focal plane to capture target light. We describe a technique to measure the positioning accuracy of fibers by dithering fibers slightly around their ideal locations. This approach also enables measurement of the total system throughput and point-spread function delivered to the focal plane. We then apply this technique to observations from the Dark Energy Survey Instrument (DESI), and demonstrate that DESI positions fibers to within 0farcs08 of their targets (5% of a fiber diameter) and achieves a system throughput within about 7% of expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Archetype-based Redshift Estimation for the Dark Energy Spectroscopic Instrument Survey

We present a computationally efficient galaxy archetype-based redshift estimation and spectral classification method for the Dark Energy Survey Instrument (DESI) survey. The DESI survey currently relies on a redshift fitter and spectral classifier using a linear combination of principal component analysis–derived templates, which is very efficient in processing large volumes of DESI spectra within a short time frame. However, this method occasionally yields unphysical model fits for galaxies and fails to adequately absorb calibration errors that may still be occasionally visible in the reduced spectra. Our proposed approach improves upon this existing method by refitting the spectra with carefully generated physical galaxy archetypes combined with additional terms designed to absorb data reduction defects and provide more physical models to the DESI spectra. We test our method on an extensive data set derived from the survey validation (SV) and Year 1 (Y1) data of DESI. Our findings indicate that the new method delivers marginally better redshift success for SV tiles while reducing catastrophic redshift failure by 10%–30%. At the same time, results from millions of targets from the main survey show that our model has relatively higher redshift success and purity rates (0.5%–0.8% higher) for galaxy targets while having similar success for QSOs. These improvements also demonstrate that the main DESI redshift pipeline is generally robust. Additionally, it reduces the false-positive redshift estimation by 5%–40% for sky fibers. We also discuss the generic nature of our method and how it can be extended to other large spectroscopic surveys, along with possible future improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting Turbulence-induced Errors in Fiber Positioning for the Dark Energy Spectroscopic Instrument

Highly multiplexed, robotic, fiber-fed spectroscopic surveys are observing tens of millions of stars and galaxies. For many systems, accurate positioning relies on imaging the fibers in the focal plane and feeding that information back to the robotic positioners to correct their positions. Inhomogeneities and turbulence in the air between the focal plane and the imaging camera can affect the measured positions of fibers, limiting the accuracy with which fibers can be placed on targets. For the Dark Energy Spectroscopic Instrument, we dramatically reduced the effect of turbulence on measurements of positioner locations in the focal plane by taking advantage of stationary positioners and the correlation function of the turbulence. We were able to reduce positioning errors from 7.3 to 3.5 μm, speeding the survey by 1.6% under typical conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensing analytical instrument parameters, specimen characteristics, or both from sparse datasets

Disclosed are methods for sensing conditions of an electron microscope system and/or a specimen analyzed thereby. Also disclosed are sensor systems and electron microscope systems able to sense system conditions, and/or conditions of the specimen being analyzed by such systems. In one embodiment, a sparse dataset can be acquired from a random sub-sampling of the specimen by an electron beam probe of the electron microscope system. Instrument parameters, specimen characteristics, or both can be estimated from the sparse dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-contact velocity measurement instruments and systems, and related methods

Methods for calibration of non-contact velocity measurements and systems for implementing the same are described. Generally, the method comprises inducing a shock wave into a sample at a stress intensity that varies across the sample's elastic limit, which corresponds to the elastic-plastic state transition of the sample. That transition state may be at the sample's Hugoniot elastic limit. The velocity of the sample is measured using a non-contact velocity measurement instrument such as a velocimeter. The measurement may be compared to a predicted velocity or a velocity measurement made by another system to determine calibration parameters.

47 OTHER INSTRUMENTATION↗

Dynamic Model Agnostic Reliability Evaluation of Machine-Learning Models Integrated in Instrumentation & Control Systems

In recent years, the field of machine learning (ML), specifically neural networks, has grown significantly and has spurred research in its applicability to digital instrumentation and control systems (DI&C). While ML models have shown promise in operational contexts, the trustworthiness of using such algorithms has not been adequately assessed. Failures of ML integrated systems are not well understood, and the lack of comprehensive risk modeling can degrade the trustworthiness in these systems. In recent reports by the National Institute for Standards and Technology (NIST) [1] and the Nuclear Regulatory Commission (NRC) [2], they indicate that trustworthiness in ML is a critical barrier and will play a vital role in the safe, accountable, and secure operation of intelligent systems. Thus, in this work, we demonstrate a dynamic model-agnostic method to quantify the relative reliability of AI/ML predictions by incorporating out-of-distribution (OOD) detection on the training dataset. It is well documented that most ML algorithms excel at interpolation (or near-interpolation) tasks but experience significant performance degradation at extrapolation. The method, referenced as the Laplacian distributed decay for reliability (LADDR), determines the difference between the operational and training datasets which can used to the relative reliability of AI/ML predictions. LADDR is then demonstrated on a feedforward neural network based digital twin used for the prediction of safety significant factors during a loss-of-flow transient. LADDR is used to demonstrate how training data can be used as evidence to support the relative reliability of ML/AI predictions enhancing the overall trustworthiness of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity and Importance Measure Analyses for Various Design Architectures for High Safety-Significant Safety-Related Digital Instrumentation and Control Systems of Nuclear Power Plants

A transition from analog instrumentation and control (I&C) technologies to digital I&C technologies is taking place for license renewals of existing nuclear power plants and for operating licenses of new advanced reactors. This transition necessitates research on risk and economic assessments of digital I&C technologies to ensure the long-term safety and reliability of vital systems, reduce uncertainty in licensing costs in addition to timeline, support integration of digital I&C systems in the plant, and find the most efficient technology upgrades. Adding redundancy within systems or components is a common means of improving design safety; however, it can also make designs more prone to common-cause failures (CCFs). Introducing diversity into redundant systems or components is a way to mitigate and possibly eliminate CCFs, but it also increases plant complexity and may be costly. The balance between redundancy and diversity remains a challenge for digital I&C systems. This study performs sensitivity and importance analyses for four design architectures of two digital I&C systems—the reactor-trip system and the engineered safety features actuation system. For each system, two architectures are examined, including a redundant, non-diverse configuration and a redundant, diverse configuration. The sensitivity analysis will provide insights on the impact of introducing diversity to system reliability. The importance results will help identify risk-significant and risk-sensitive components and failure modes, which may be good candidates for future design improvement.

99 GENERAL AND MISCELLANEOUS↗

Digital Instrumentation & Controls Study with Operating Experience Data

The slides present the plan and working progress on the digital instrumentation and control (DI&C) study with nuclear industry operating experience data. They were originally prepared as a working document and presented to the NRC, but then was asked by the NRC to present to an EPRI/NRC meeting on DI&C. The slides will also be distributed to the meeting participants.

99 GENERAL AND MISCELLANEOUS↗

Limerick Safety-Related Instrumentation and Control Upgrade Human Factors Engineering Preliminary Validation Report

This document is a results summary report for the human factors engineering (HFE) preliminary validation (PV) performed for the Limerick Generating Station (LGS) Safety-Related (SR) Instrumentation and Control (I&C) Upgrade Project at the Idaho National Laboratory (INL) Human Systems Simulation Laboratory (HSSL). This occurred during the week of February 20, 2023.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The chemRIXS Instrument for Solution-Phase Resonant Inelastic X-ray Scattering at the Linac Coherent Light Source

The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗