Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Force”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Analysis of Electro-static Assisted Air Dehumidification

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 μm in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Analysis of New Data of Electro-static Assisted Air Dehumidification Processes

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 m in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

A Moist Potential Vorticity Model for Midlatitude Long-Lived Mesoscale Convective Systems over Land

Mesoscale convective systems (MCSs) bring large amounts of rainfall and strong wind gusts to the midlatitude land regions, with significant impacts on local weather and hydrologic cycle. However, weather and climate models face a huge challenge in accurately modeling the MCS life cycle and the associated precipitation, highlighting an urgent need for a better understanding of the underlying mechanisms of MCS initiation and propagation. From a theoretical perspective, a suitable model to capture the realistic properties of MCSs and isolate the bare-bones mechanisms for their initiation, intensification, and eastward propagation is still lacking. To simulate midlatitude MCSs over land, we develop a simple moist potential vorticity (PV) model that readily describes the interactions among PV perturbations, air moisture, and soil moisture. Multiple experiments with or without various environmental factors and external forcing are used to investigate their impacts on MCS dynamics and mesoscale circulation vertical structures. The result shows that mechanical forcing can induce lower-level updraft and cooling, providing favorable conditions for MCS initiation. A positive feedback among surface winds, evaporation rate, and air moisture similar to the wind-induced surface heat exchange over tropical ocean is found to support MCS intensification. Both background surface westerlies and vertical westerly wind shear are shown to provide favorable conditions for the eastward propagation of MCSs. Last, our result highlights the crucial role of stratiform heating in shaping mesoscale circulation response. In conclusion, the model should serve as a useful tool for understanding the fundamental mechanisms of MCS dynamics.

54 ENVIRONMENTAL SCIENCES↗

Electric-Field De-Wetting for Enhanced Drying

Drying processes are one of the most energy intensive operations. Drying accounts for anywhere from 12 to 20% of the energy consumption in the industrial sector. While many different drying processes and thus technologies exist and each is appropriate for particular applications, convective heated-air dryers account for about 85% of all industrial dryers, where air is heated by the combustion of fossil fuels prior to being forced through the product. The electric-field dewetting concept evaluated has the potential to increase heat pumping efficiency by 30% assuming a typical sensible heat ratio of 70%. At full deployment, this can reduce drying energy by 25%. Further, the technology can benefit the performance of air-source heat pumps in general and broaden their application base resulting in greater energy reductions.

42 ENGINEERING↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants' chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies: Preprint

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants’ chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

Air oxidation of yttrium hydride as a high temperature moderator for thermal neutron spectrum fission reactors

Yttrium hydride (YH x ) is an attractive moderator material for thermal neutron spectrum fission reactors requiring a small reactor core volume and has been selected as the neutron moderator for the Transformational Challenge Reactor (TCR), an advanced gas-cooled microreactor. Before YH x can be used in this application, it is important to understand the material response to off-normal conditions. In the present study, 550–650 °C isothermal dry air oxidation was performed to simulate a depressurized loss of force circulation (DLOFC) event. The oxidation was performed using thermogravimetric analysis (TGA) on bulk crack-free YHx coupons. Oxidation studies were also performed on Y coupons to elucidate the impact of H on oxidation. Both the chemistry and distribution of processing impurities were found to strongly affect oxidization behavior on a batch-to-batch basis. Regardless of batch, YHx oxidized at a significantly lower rate than Y at all temperatures, and the lower rate was directly correlated with increased hydride content. Metallic Y exhibited complex exponential kinetics, whereas YH x also exhibited complex kinetics but gained considerably less mass. According to literature reports on protonic and native-ion conductivities of Y 2 O 3 and mass spectrometry analysis of gaseous reaction products formed during the oxidation of YH x , a mechanism for the reduced oxidation rate of yttrium hydride is suggested.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Meteorology and Snow Data Set From Adjacent Forested and Meadow Sites at Crested Butte, CO, USA

We present meteorology and snow observation data collected at sites in the southwestern Colorado Rocky Mountains (USA) over three consecutive water years with different amounts of snow water equivalent (SWE) accumulation: A year with above average SWE (2019), a year with average SWE (2020), and a year with below average SWE (2021). This data set is distinguished by its emphasis on paired open-forest sites in a continental snow climate. Approximately once a month during February–May, we collected data from 15 to 20 snow pits and took 8 to 19 snow depth transects. Our sampling sites were in open and adjacent forested areas at 3,100 m and in a lower elevation aspen (3,035 m) and higher elevation conifer stand (3,395 m). In total, we recorded 270 individual snow pit density and temperature profiles and over 4,000 snow depth measurements. These data are complimented by continuous meteorological measurements from two weather stations: One in the open and one in the adjacent forest. Meteorology data—including incoming shortwave and longwave radiation, outgoing shortwave radiation, relative humidity, wind speed, snow depth, and air and infrared surface temperature—were quality controlled and the forcing data were gap-filled. These data are available to download from Bonner, Smyth, et al. at three levels of processing, including a level with downscaled, adjusted precipitation based on data assimilation using observed snow depth and a process-based snow model. We demonstrate the utility of these data with a modeling experiment that explores open-forest differences and identifies opportunities for improvements in model representation.

54 ENVIRONMENTAL SCIENCES↗

Numerical simulation of streamer evolution in surface dielectric barrier discharge with electrode-array

Atmospheric pressure surface dielectric barrier discharges (SDBDs) may be composed of streamers fast propagating along a dielectric surface in ambient air, producing reactive oxygen and nitrogen species, and inducing a force on the neutral gas, which can find applications, respectively, in plasma medicine and aerodynamics. In this work, a two-dimensional self-consistent fluid model was developed to study SDBDs with an electrode-array. Emphasis was placed on the interaction of counter-propagating streamers and discharge uniformity for different applied voltages and geometric configurations of the electrode-array. When two counter-propagating streamers collide, the streamers come to a stop within a certain (ultimate) distance between the streamer heads. Optimizing the applied voltages is a convenient way to improve uniformity, making the streamer heads reach a minimum distance between each other. Shortening the electrode spacing can simultaneously shorten the streamer length and the ultimate distance between streamers. Under certain discharge parameters (such as applied voltage), there exists an optimum electrode spacing maximizing uniformity.

42 ENGINEERING↗

An Experimental and Theoretical Examination of Air Ingress Rates During Small- and Medium-Break Air Ingress Accidents

Here, air ingress measurements using the 1/20th-scaled Helium Air Ingress gas Reactor Experiment (HAIRE) facility show key geometric variables of interest and their effect on air ingress in small- and medium-sized breaks in High Temperature Gas cooled Reactors. These variables include but are not limited to break diameter, break angle, and break wall thickness. Differing wall thicknesses for the same break diameter can have order-of-magnitude changes to the air ingress rate, which is a key figure of merit in the air ingress accident scenario. Additionally, different break sizes can change the importance of the angle in the break scenario. With smaller breaks, the flow will not transition from intermittent flow, to countercurrent flow, to diffusive flow as the break rotates from vertically upward toward vertically downward. This would lead to less variability with smaller breaks, which in turn would make the accident scenario more predictable for smaller-sized breaks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Image Collection Simulation Using High-Resolution Atmospheric Modeling

A new method is described for simulating the passive remote sensing image collection of ground targets that includes effects from atmospheric physics and dynamics at fine spatial and temporal scales. The innovation in this research is the process of combining a high-resolution weather model with image collection simulation to attempt to account for heterogeneous and high-resolution atmospheric effects on image products. The atmosphere was modeled on a 3D voxel grid by a Large-Eddy Simulation (LES) driven by forcing data constrained by local ground-based and air-based observations. The spatial scale of the atmospheric model (10–100 m) came closer than conventional weather forecast scales (10–100 km) to approaching the scale of typical commercial multispectral imagery (2 m). This approach was demonstrated through a ground truth experiment conducted at the Department of Energy Atmospheric Radiation Measurement Southern Great Plains site. In this experiment, calibrated targets (colored spectral tarps) were placed on the ground, and the scene was imaged with WorldView-3 multispectral imagery at a resolution enabling the tarps to be visible in at least 9–12 image pixels. The image collection was simulated with Digital Imaging and Remote Sensing Image Generation (DIRSIG) software, using the 3D atmosphere from the LES model to generate a high-resolution cloud mask. The high-resolution atmospheric model-predicted cloud coverage was usually within 23% of the measured cloud cover. The simulated image products were comparable to the WorldView-3 satellite imagery in terms of the variations of cloud distributions and spectral properties of the ground targets in clear-sky regions, suggesting the potential utility of the proposed modeling framework in improving simulation capabilities, as well as testing and improving the operation of image collection processes.

54 ENVIRONMENTAL SCIENCES↗

Comparison of ozone formation attribution techniques in the northeastern United States

The Integrated Source Apportionment Method (ISAM) has been revised in the Community Multiscale Air Quality (CMAQ) model. This work updates ISAM to maximize its flexibility, particularly for ozone (O 3 ) modeling, by providing multiple attribution options, including products inheriting attribution fully from nitrogen oxide reactants, fully from volatile organic compound (VOC) reactants, equally from all reactants, or dynamically from NO x or VOC reactants based on the indicator gross production ratio of hydrogen peroxide (H 2 O 2 ) to nitric acid (HNO 3 ). The updated ISAM has been incorporated into the most recent publicly accessible versions of CMAQ (v5.3.2 and beyond). This study's primary objective is to document these ISAM updates and demonstrate their impacts on source apportionment results for O 3 and its precursors. Additionally, the ISAM results are compared with the Ozone Source Apportionment Technology (OSAT) in the Comprehensive Air-quality Model with Extensions (CAMx) and the brute-force method (BF). All comparisons are performed for a 4 km horizontal grid resolution application over the northeastern US for a selected 2 d summer case study (9 and 10 August 2018). General similarities among ISAM, OSAT, and BF results add credibility to the new ISAM algorithms. However, some discrepancies in magnitude or relative proportions among tracked sources illustrate the distinct features of each approach, while others may be related to differences in model formulation of chemical and physical processes. Despite these differences, OSAT and ISAM still provide useful apportionment data by identifying the geographical and temporal contributions of O 3 and its precursors. Both OSAT and ISAM attribute the majority of O 3 and NO x contributions to boundary, mobile, and biogenic sources, whereas the top three contributors to VOCs are found to be biogenic, boundary, and area sources.

54 ENVIRONMENTAL SCIENCES↗

Synoptic and Mesoscale Modulation of Dynamic and Thermodynamic Impacts on Central Arctic Sea Ice During MOSAiC

The primary objectives of this proposed project are to determine 1) to what extent dynamic and thermodynamic air‐ice interactions in the Central Arctic are driven by atmospheric synoptic and mesoscale phenomena, and 2) the key processes involved in these interactions. These phenomena include large‐scale features such as fronts, high‐ and low‐pressure systems, low‐level jets, and cloud bands, but may also include smaller‐scale phenomena such as mesoscale instabilities (e.g., symmetric instability or slantwise convection), transient meso‐lows and gravity waves. Dynamic air‐ice interactions include direct atmospheric stress and atmospheric stress divergence/deformation; thermodynamic air‐ice interactions involve the net surface energy budget, especially in association with non‐stratocumulus clouds generally occurring with stronger dynamical forcing.

58 GEOSCIENCES↗

Electrostatic Dehumidification

This project undertook an effort to experimentally demonstrate the ability to change the water content of an air volume through electrostatic, non-condensing means. Humid air is primarily a mixture of nitrogen, oxygen, argon, carbon dioxide and water vapor. Water is unique in this mixture because it possesses a relatively strong natural dipole moment. The physics of electrophoresis offers promise that electrostatic forces could be used to compel movement of water molecules, while leaving the other air components un-affected, which could be exploited to cause a concentration gradient of water within an air-stream.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adhesion-force micro-scale study of desiccating granular material

Experiments on five-, four-, three- and two-wet-hydrophilic-grain clusters were performed to investigate evolution of adhesion of granular media during drying on the micro-scale. The experiments show that the adhesion-force of a cluster initially grows at most to three times the original value before decreasing to zero by the end of evaporation. The adhesion-force is composed of capillary pressure force acting over the liquid/solid contact surface area, and surface tension forces acting over the three-phase contact perimeter length. This is in contrast with most macro-scale phenomenological models, in which the only desaturation process variables affecting strength are suction and saturation. Both the contact surface area and contact perimeter length are reduced to zero upon complete liquid evaporation. The morphology of an evaporating water body evolves through slow flow controlled by evaporation rate, interrupted by various modes of fast air entry, which are non-equilibrium jumps of liquid/gas interfaces (Haines jumps). The instabilities involve large adhesion force discontinuities and substantial water mass reconfiguration with water flow in an extremely short time, which makes the process transient. The reconfigurations can reduce the original multi-grain water clusters to four-, three- and two-grain clusters by way of three different instability modes: of thin-sheet instability, or meniscus snap-through instability, depending on the sign of the Gauss curvature of the liquid surface, or finally, for two-grain bridges only, a liquid wire pinch-off. For larger meso-scale assemblies, however, the global adhesion-force evolution is little affected by the jumps. The air entries are potential sites for drying cracks. The (approximately) calculated capillary pressure for two- and three-grain clusters, in no cases is seen to reach high values, predicted from water retention curves.

Engineering↗

On the Relationship Between the Marine Cold Air Outbreak M Parameter and Low-Level Cloud Heights in the Midlatitudes

Focusing on conditions of subsidence when low clouds are present, ground-based observations in both the North Atlantic and the Southern Ocean reveal strong relationships between cloud boundary (base and top heights) and different measures of lower tropospheric instability. The difference in potential temperature between the surface and 800 hPa (a metric called M) provides a stronger relationship than measures of inversion strength such as the lower tropospheric stability and estimated inversion strength. This is because (1) inversion strength itself does not correlate well with cloud boundaries, and (2) M contains information that appears important for cloud boundaries. These include the surface forcing through the use of sea surface rather than near-surface air temperature and an upper level close to the real cloud top. These results expand upon previous work on the importance of M as a predictor of cloud morphology. However, important differences are found in low-cloud conditions for the North Atlantic as compared to the Southern Ocean (for a given value of M): stronger inversions, deeper boundary layers, and much larger sea level pressures. Therefore, the relationship between cloud boundaries and M differs between the two regions. A general circulation model provides similar relationships as observed between M and both cloud top height and temperature but tends to place clouds higher and at colder temperatures than observed for a given M. This might cause issues with the representation of precipitation, cloud cover and radiation in the Southern Ocean.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of the water-plasma interface in various discharge modes of atmospheric-pressure plasmas

This paper presents an experimental study of the dynamics of the water-plasma interface during the interaction high-voltage (HV) atmospheric pressure discharge with the water surface. Under the influence of the voltage applied to the pin type electrode, discharges are formed at the air layer between the sharp-tip HV electrode and deionized water. Three discharge regimes were identified from synchronized electrical waveforms and imaging: (i) a weak linear regime at 3–10.6 kV, (ii) a branching streamer regime at the maximum applied voltage of 12.6 kV, and (iii) a continuous arc-like regime occurring during the transition to lower voltage and higher current (e.g., U ≈ 3.2 kV, I ≈ 4.07 mA). High-speed shadowgraph images showed a symmetric interfacial cavity whose depth increased nonlinearly with voltage from h 0 ≈ 0.1 mm at 3 kV to h 0 ≈ 2.7 mm at 10.6 kV, reaching a maximum depth of h 0 ≈ 5.9 mm at 12.6 kV, while the cavity disappeared in the continuous-channel regime and was replaced by outward-propagating wave-like motion. The deformation of the water surface during the discharge-water interaction is governed by the balance between electric field forces, surface tension, gravitational forces, and electrohydrodynamic forces, whose relative contributions vary with the applied voltage. This effect was explained by quantitatively estimating the magnitudes of the acting forces and establishing the force balance. Optical emission spectroscopy in the continuous-channel regime indicated air plasma signatures and yielded a gas temperature of approximately 400 K, while prolonged operation (≈ 20 min) increased the water temperature to ~ 70 °C, reduced the water-layer thickness from 6 mm to 3 mm, and decreased pH from 7 to 4. These regime-resolved, quantitative results clarify how the dominant interfacial forcing shifts with discharge mode and provide a mechanistic basis for controlling plasma-water interactions in atmospheric-pressure applications.

atmospheric pressure plasma↗

Direct visualization of radiation-induced transformations at alkali halide–air interfaces

Radiation driven reactions at mineral/air interfaces are important to the chemistry of the atmosphere, but experimental constraints (e.g. simultaneous irradiation, in situ observation, and environmental control) leave process understanding incomplete. Using a custom atomic force microscope equipped with an integrated X-ray source, transformation of potassium bromide surfaces to potassium nitrate by air radiolysis species was followed directly in situ at the nanoscale. Radiolysis initiates dynamic step edge dissolution, surface composition evolution, and ultimately nucleation and heteroepitaxial growth of potassium nitrate crystallites mediated by surface diffusion at rates controlled by adsorbed water. Finally, in contrast to in situ electron microscopy and synchrotron-based imaging techniques where high radiation doses are intrinsic, our approach illustrates the value of decoupling irradiation and the basis of observation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗