A distributed voltage inference framework for cyber-physical attacks detection and localization in active distribution grids

The transition to active distribution grids with real-time monitoring and control depends on the proliferation of advanced communication networks and devices. This paradigm shift towards a cyber-physical architecture also introduces new vulnerabilities for adversaries to exploit and launch sophisticated cyber-physical attacks targeting grid observability. Current research highlights the challenges in distinguishing attacks on voltage phasor or nodal injection measurements and isolating multi-source attack locations in a multiphase distribution grid. The attack detection and localization methods in literature face accuracy issues, applications across diverse attack scenarios, or scalability limits. Here, to bridge these gaps, this paper proposes a distributed Voltage Inference framework for real-time detection and localization of cyber-physical attacks, addressing scalability, adaptability, and accuracy challenges in state-of-the-art methods. The proposed methodology leverages the distributed nature of the Voltage Inference framework through a two-step process of prediction and correction, together with a tractable graph partitioning approach, providing a reliable solution to identify compromised measurement sources and facilitate isolation. Extensive testing on IEEE 13 and 123-node distribution feeders underscores the algorithm’s efficacy, enhancing the security and resilience of active distribution grids against evolving cyber threats. Additionally, Hardware-in-the-Loop (HIL) implementation validates the proposed strategy’s practical applicability in real-world scenarios.

active distribution grids↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of convective cells, turbulence, and transport induced by a radio-frequency antenna in the tokamak boundary plasma

The edge turbulence model Hermes (Dudson et al 2017 Plasma Phys. Control. Fusion 59 05401) is set up for plasma boundary simulations with an radiofrequency (RF) antenna, using parameters characteristic of a tokamak edge. Cartesian slab geometry is used with thin plate limiters representing the ion cyclotron range of frequency (ICRF) antenna side-wall limiters. Ad-hoc DC electric biasing of the limiters, motivated by calculations with VSim (Nieter et al 2004 J. Comput. Phys. 196 448), represents an induced RF sheath rectified potential in the plasma turbulence model. Flux-driven turbulence simulations demonstrate a realistic distribution of plasma profiles and fluctuations. There is a clear effect of the antenna sheath voltage leading to formation of convective cells; bias-induced convective transport flattens the scrape-off layer density profile and fluctuations penetrate into the shadow region of the limiters as the bias voltage increases. Turbulent transport for impurity ions is inferred by following ion trajectories in the simulated plasma turbulence fields, showing Bohm-like effective diffusion rates. All in all, the model elucidates the key physical phenomena governing the effects of ICRF-induced antenna biasing on the tokamak boundary plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing Mg Intercalation in the Tetragonal Tungsten Bronze Framework V 4 Nb 18 O 55

While commercial Li-ion batteries offer the highest energy densities of current rechargeable battery technologies, their energy storage limit has almost been achieved. Therefore, there is considerable interest in Mg batteries, which could offer increased energy densities in comparison to Li-ion batteries if a high-voltage electrode material, such as a transition-metal oxide, can be developed. However, there are currently very few oxide materials which have demonstrated reversible and efficient Mg 2+ insertion and extraction at high voltages; this is thought to be due to poor Mg 2+ diffusion kinetics within the oxide structural framework. Here, in this paper, the authors provide conclusive evidence of electrochemical insertion of Mg 2+ into the tetragonal tungsten bronze V 4 Nb 18 O 55 , with a maximum reversible electrochemical capacity of 75 mA h g –1 , which corresponds to a magnesiated composition of Mg 4 V 4 Nb 18 O 55 . Experimental electrochemical magnesiation/demagnesiation revealed a large voltage hysteresis with charge/discharge (1.12 V vs Mg/Mg 2+ ); when magnesiation is limited to a composition of Mg 2 V 4 Nb 18 O 55 , this hysteresis can be reduced to only 0.5 V. Hybrid-exchange density functional theory (DFT) calculations suggest that a limited number of Mg sites are accessible via low-energy diffusion pathways, but that larger kinetic barriers need to be overcome to access the entire structure. The reversible Mg 2+ intercalation involved concurrent V and Nb redox activity and changes in crystal structure, as confirmed by an array of complementary methods, including powder X-ray diffraction, X-ray absorption spectroscopy, and energy-dispersive X-ray spectroscopy. Consequently, it can be concluded that the tetragonal tungsten bronzes show promise as intercalation electrode materials for Mg batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Higher Voltage Solid-State Batteries by Metastability and Kinetic Stability Design

The energy density of battery systems is limited largely by the electrochemical window of the electrolyte. Here, the combined thermodynamic and kinetic effects of mechanically induced metastability are shown to greatly widen the operational voltage window of solid-state batteries based on ceramic-sulfide electrolytes. Solid electrolyte voltage stability up to 10 V is achieved with minimal degradation, far beyond the capability of organic liquid electrolytes. Furthermore, combined experiment, ab initio computation, and theoretical modeling identify the nature of mechanically constrained Li 10 GeP 2 S 12 decomposition both within the bulk and at interfaces with cathode materials at very high voltages. Previously unclear kinetic processes are identified that, when properly implemented, can potentially allow solid-state full cells with remarkably high operational voltages.

25 ENERGY STORAGE↗

Ultra‐Steep Slope Impact Ionization Transistors Based on Graphene/InAs Heterostructures

With the continued scaling of transistors, there is a growing trend for developing steep slope transistors with subthreshold swing (SS) below Boltzmann limitation ( k T/ q ). To this end, impact ionization metal oxide semiconductor (I‐MOS) transistors are attractive for a unique combination of high ON‐state current density, small hysteresis, and ultra‐steep SS slope. However, the performance of I‐MOS is generally limited by the relatively thick depletion region and large operation voltage required for the activation of impact ionization (typically >5 V). Herein, a high‐performance I‐MOS is constructed by van der Waals integrating single‐crystal InAs film with graphene. Due to the low bandgap of InAs as well as the semi‐metallic nature of graphene, the InAs/graphene I‐MOS demonstrates a low operation voltage of 1.5 V, high ON‐state current of 230 μA μm −1 , steep SS <0.6 mV dec −1 , and large ON–OFF ratio >10 6 at temperature below 200 K. Furthermore, a negative transconductance and steep current oscillation is observed in the subthreshold regime, and a device working mechanism is proposed for this novel phenomenon. This study not only pushes the performance limit of I‐MOS but also defines a general pathway to van der Waals heterostructures between conventional III–V compound semiconductors and novel 2D materials for unconventional device functions.

Liu, Yuan↗

Effect of Mechanical Deformation on the Dielectric Electric Field in Dynamic Umbilical Cables

Wave energy converter (WEC) systems have unique umbilical cable design requirements compared to conventional marine designs. Due to their dynamic nature, WEC umbilical cables are required to handle increased loads and larger motions over longer deployment scenarios. However, the life expectancy of dynamic umbilical cables is predominantly analyzed for mechanical fatigue, with little consideration given to the effect of mechanical stress on the response of the dielectric as it has been previously assumed that the non-polymeric components will fail prior to the polymeric components. In this work, we explore the effects of mechanical bending on the concentration of the electric field in the insulation of a conceptual three-core dynamic umbilical cable to determine the limiting requirements for life expectancy. A conceptual industrial schematic of a medium voltage dynamic umbilical cable was used as the basis for the WEC system under study. Simulations on the dynamic umbilical cable were performed using COMSOL Multiphysics®. Mechanical loads up to the calculated limit (2.64 m minimum bend radius or 388 kN transverse load) were applied to the dynamic umbilical in a step-wise fashion with one end of the umbilical cable fixed. One-way coupling in three-dimensions was conducted by first determining the engineering strains, then using the engineering strains as the initial condition for determination of the Green-Lagrange strains, and lastly calculating the electric field in the deformed dielectric. Based upon the input load, deformation of the dielectric at the minimum bend radius produced an increase in the electric field of more than 12% when compared to the undeformed umbilical cable, which may lead to dielectric breakdown of the insulation prior to mechanical failure of the umbilical cable.

Spencer, Mychal P.↗

Electrostatic Gating of Ionic Conductance through Heterogeneous van der Waals Nanopores

Nanofluidic ionic transistors typically require gate voltages above 1 V and operate only at submillimolar ionic strengths, limiting their biocompatible applications. We demonstrate ionic transistors consisting of single sub-10 nm nanopores drilled in van der Waals (vdW) heterostructures with internal gate electrodes made of few-layer graphene. These devices deliver up to 10-fold current modulation at gate voltages as low as 0.3 V in 10 mM KCl, and ∼2-fold modulation at near-physiological 100 mM KCl. Baseline conductance with no gate shows surface-charge-dominated transport below 100 mM KCl, consistent with negatively charged hBN walls and ∼5 nm opening of the pores. The surface charge and the electrochemical asymmetry introduced by the three-electrode configuration govern the device’s behavior: negative gate voltage (V G ) enriches ionic concentrations and enhances current, whereas positive V G induces a local depletion zone that suppresses transport. The current modulation by V G is dependent on the polarity of the transmembrane potential and leads to ion current rectification. Molecular dynamics simulations of a nanopore in a hBN–graphene–hBN stack reveal confinement and surface charge-dependent suppression of the relative permittivity of interfacial water. Continuum modeling with radially varying interfacial water permittivity reproduces the asymmetric I–V characteristics and explains how the embedded gate sculpts local potential and ion concentrations. By enabling sub-0.5 V control of ionic transport at up to 100 mM salt concentrations, these devices address a key need in nanofluidics to create low-power ionic circuits and biosensing.

Materials science↗

The transition from field emission to collisional space-charge limited current with nonzero initial velocity

Abstract Multiple electron emission mechanisms often contribute in electron devices, motivating theoretical studies characterizing the transitions between them. Previous studies unified thermionic and field emission, defined by the Richardson-Laue-Dushman (RLD) and Fowler–Nordheim (FN) equations, respectively, with the Child-Langmuir (CL) law for vacuum space-charge limited current (SCLC); another study unified FN and CL with the Mott-Gurney (MG) law for collisional SCLC. However, thermionic emission, which introduces a nonzero injection velocity, may also occur in gas, motivating this analysis to unify RLD, FN, CL, and MG. We exactly calculate the current density as a function of applied voltage over a range of injection velocity (i.e., temperature), mobility, and gap distance. This exact solution approaches RLD, FN, and generalized CL (GCL) and MG (GMG) for nonzero injection velocity under appropriate limits. For nonzero initial velocity, GMG approaches zero for sufficiently small applied voltage and mobility, making these gaps always space-charge limited by either GMG at low voltage or GCL at high voltage. The third-order nexus between FN, GMG, and GCL changes negligibly from the zero initial velocity calculation over ten orders of magnitude of applied voltage. These results provide a closed form solution for GMG and guidance on thermionic emission in a collisional gap.

42 ENGINEERING↗

Switching-Cycle-Based Startup for Grid-tied Inverters

This paper presents a novel switching cycle-based startup approach that eliminates the need for voltage sensors and phase-locked loops. Here, the proposed method surpasses the bandwidth limitations inherent in traditional PLL-based synchronization techniques and attains grid synchronization of the inverter within two switching cycles. Despite the absence of voltage sensors and PLLs, this synchronization is achieved without inrush currents. Furthermore, the startup method does not necessitate the addition of any hardware or an increase in software complexity. Simulation and experimental results are presented to verify the effectiveness of the proposed method.

42 ENGINEERING↗

A Novel Voltage Balancing Control With dv/dt Reduction for 10-kV SiC MOSFET-Based Medium Voltage Modular Multilevel Converter

Using high voltage (HV) silicon carbide (SiC) power semiconductors in a modular multilevel converter (MMC) is promising because it results in fewer submodules and lower switching loss compared to conventional Si based solutions. The nearest level pulsewidth modulation (NL-PWM) is commonly used in the MMC for medium voltage applications. However, with the NL-PWM and existing voltage balancing control, there are many submodules that switch their modes in a control cycle, resulting in a high dv/dt during the deadtime of the power semiconductor, which could be multiple times of the dv/dt of the single device. This poses great challenges on the noise immunity and insulation design in the MMC using HV SiC devices, which have very fast switching speed. A novel voltage balancing control, which ensures only two submodules switch their modes in a control cycle, is proposed in this article, limiting the maximum dv/dt to the dv/dt of a single power semiconductor and also maintaining the voltage balance performance. Furthermore, the proposed voltage balancing control is experimentally validated in a 10-kV SiC mosfet based MMC with four submodules per arm.

42 ENGINEERING↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Characterization of LAPPD timing at CERN PS testbeam

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm 2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. Finally, the measured time resolution for single photoelectrons is about 80 ps r.m.s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Architecting a Stable High-Energy Aqueous Al-Ion Battery

Aqueous Al-ion batteries (AAIBs) are the subject of great interest due to the inherent safety and high theoretical capacity of aluminum. The high abundancy and easy accessibility of aluminum raw materials further make AAIBs appealing for grid-scale energy storage. However, the passivating oxide film formation and hydrogen side reactions at the aluminum anode as well as limited availability of the cathode lead to low discharge voltage and poor cycling stability. Here, we proposed a new AAIB system consisting of an Al x MnO 2 cathode, a zinc substrate-supported Zn-Al alloy anode, and an Al(OTF) 3 aqueous electrolyte. Through the in situ electrochemical activation of MnO, the cathode was synthesized to incorporate a two-electron reaction, thus enabling its high theoretical capacity. The anode was realized by a simple deposition process of Al 3+ onto Zn foil substrate. The featured alloy interface layer can effectively alleviate the passivation and suppress the dendrite growth, ensuring ultralong-term stable aluminum stripping/plating. The architected cell delivers a record-high discharge voltage plateau near 1.6 V and specific capacity of 460 mAh g -1 for over 80 cycles. Finally, this work provides new opportunities for the development of high-performance and low-cost AAIBs for practical applications.

25 ENERGY STORAGE↗

How Does Water Dissociation Work in Bipolar Membranes?

Bipolar membranes (BPMs) create counteracting spatial gradients of pH and electrostatic potential in electrochemical systems, enabling applications in pH regulation, electrocatalysis, and separations. At the polarized junction of a BPM the water dissociation (WD, 2H2O ⇌ H3O+ + OH-) reaction can be driven, but it remains poorly understood. In this Perspective, we integrate molecular insights from bulk-water autoionization and the associated field effects with continuum descriptions of BPM electrostatics and experimental WD kinetic analyses to describe possible mechanisms of voltage-driven WD. Pristine BPM junctions highlight both the limits of primarily electric-field-driven WD and the practical challenges of junction stability at extreme reverse bias. Introducing heterogeneous catalyst layers, commonly metal oxides and graphene oxides, accelerates WD by orders of magnitude through hypothesized coupled effects in which surface acid-base functionality and high-density hydroxyl sites mediate proton-transfer steps, and catalyst mobile electronic/ionic charges redistribute the junction electric potential drop to shape the local electric fields and reactive microenvironments. Kinetic analyses suggest two regimes of heterogeneous WD mechanism, including field-driven ordering of interfacial water and a Second-Wien-Effect dissociation-barrier lowering. We conclude by defining the key unknown variables (local pH, electrostatic potential, catalyst charge state and relationships among mechanisms) and outlining experimental and multiscale modeling strategies needed for predictive WD catalysis and for controlling related ion-transfer reactions.

Wu, Yifan↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation

As modern power systems are experiencing exceptional changes with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system could obtain high system resilience by not relying on the bulk power system restoration, which requires significant human intervention and procedure. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and the technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by- phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and startup behaviors as well as network dynamics. In addition, active involvement of grid- following distributed energy resources is also studied to facilitate the black-start process. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, we demonstrate that a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start, using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Thoughts and Hypotheses on the Metrics and Needs for the Stability of Highly Inverter-Based Island Systems

As levels of wind, photovoltaics (PVs), and battery energy storage on power systems rise, it is useful to be able to quickly compare how much generation (instantaneous power and annual energy) comes from these inverter-based resources (IBRs). A commonly used metric is the percentage of inverter-based generation (% IBR) in a dispatch scenario (as a percentage of the total generation or total load), which can be useful for estimating when certain operational challenges arise (high rates of change of frequency, underdamped control interactions, low system strength, low fault current availability, and so on). Another similar and commonly used metric pioneered on the relatively large island of Ireland, system nonsynchronous penetration (SNSP), is similar to the % IBR and is subject to similar limitations. SNSP has the advantage of handling high-voltage dc in a defined way.

fault currents↗