CTF Theory Manual

Coolant-Boiling in Rod Arrays|Two Fluids (COBRA-TF) is a thermal/ hydraulic (T/H) simulation code designed for light water reactor (LWR) vessel analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of 9 conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and had been used and modified by several institutions over the last few decades. COBRA-TF also found use at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Management Group (RDFMG) and has been improved, updated, and subsequently re-branded as CTF. As part of the improvement process, it was necessary to generate sufficient documentation for the open-source code which had lacked such material upon being adopted by RDFMG. This document serves mainly as a theory manual for CTF, detailing the many two-phase heat transfer, drag, and important accident scenario models contained in the code as well as the numerical solution process utilized. Coding of the models is also discussed, all with consideration for updates that have been made when transitioning from COBRA-TF to CTF. Further documentation outside of this manual is also available at RDFMG which focus on code input deck generation and source code global variable and module listings.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computation of Space Shuttle high-pressure cryogenic turbopump ball bearing two-phase coolant flow

A homogeneous two-phase fluid flow model, implemented in a three-dimensional Navier-Stokes solver using computational fluid dynamics methodology is described. The application of the model to the analysis of the pump-end bearing coolant flow of the high-pressure oxygen turbopump of the Space Shuttle main engine is studied. Results indicate large boiling zones and hot spots near the ball/race contact points. The extent of the phase change of the liquid oxygen coolant flow due to the frictional and viscous heat fluxes near the contact areas has been investigated for the given inlet conditions of the coolant.

Chen, Yen-Sen↗

Flow Boiling Pressure Drop Characteristics of Next-generation Refrigerants in a Micro‑fin Copper Tube

This paper presents experimental frictional pressure-drop data for flow boiling of R-410A, R-134a, and next-generation alternatives R-454C, R-455A, R-1234yf, and R-1234ze(E) in a horizontal micro-fin copper tube. Tests were conducted over a range of mass fluxes and evaporation temperatures to characterize refrigerant-dependent two-phase pressure-drop behavior. The results show that frictional pressure gradient increased with mass flux and vapor quality and generally increased as evaporation temperature decreased, with liquid viscosity strongly affecting the observed trends. Among the evaluated correlations, the Goto et al. (2001) model gave the best overall agreement with the measurements before optimization. Further optimization of the Kuo and Wang (1996) and Goto et al. (2001) models reduced the overall mean absolute deviation to below 15%, with the optimized Goto (2001) model providing the most consistent predictions across all six refrigerants. The results support improved pressure-drop prediction and evaporator design for next-generation refrigerants in micro-fin tubes.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Improvements to CTF Closure Models for Modelling of Two-Phase Flow

This report documents the efforts to improve the CTF prediction of void fraction and two-phase pressure drop by improving two-phase closure models. Previous validation activities have revealed that CTF tends to overpredict void fraction and two-phase pressure drop. In response to this, two approaches were taken to improve CTF’s predictive capabilities. Based on findings that the interfacial drag and subcooled boiling models significantly impact void prediction, alternative closure models for these physical effects were found and implemented into the code. An extensive assessment was performed by using the existing and newly added two-phase experimental data, which showed that void prediction, wall temperature, and two-phase pressure-drop results are improved by using the newly implemented models. A second approach for improving CTF modeling accuracy involved the use of a Bayesian calibration process that uses CTF validation data to optimize selected modeling coefficients and closure model multipliers to achieve a more accurate prediction of experimental results. A similar assessment was performed with calibrated models that improved the void and pressure-drop prediction for test cases that were both included and not included in the calibration dataset. Results of this study will be used to change the models used in CTF to achieve more accurate BWR analyses moving forward. This study also identified opportunities for improving additional closure models and other opportunities to use calibration techniques to improve CTF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Studies on the Effect of Inlet Liquid Subcooling on the Chilldown Characteristics of Stainless Steel Tubes

Understanding transfer line chilldown process under microgravity is important for the efficient transfer of cryogenic propellants in space fuel depots to facilitate future long duration space missions. The present work is part of the ongoing efforts to develop and test a two-phase flow chilldown test section to study the complete chilldown process under sustained microgravity conditions onboard the International Space Station. In this study, ground-based chilldown experiments are carried out on a 60 cm long SS-316 test section with PF-5060 as the working fluid. The complete chilldown curve was obtained including the film, transition and nucleate boiling regimes along with the temperature transition points. The effect of inlet liquid subcooling on the behavior of the chilldown curves are presented. Further, the chilldown and heat flux curves are analyzed to obtain re-wetting/Leidenfrost and onset of nucleate boiling temperature transition points as well as the critical heat flux values. The effect of inlet liquid subcooling on regime-specific heat flux and heat transfer coefficients are also examined.

CFD↗

Boiling-Water Reactor Testing Capability in the Advanced Test Reactor

I-Loop is an irradiation facility that is currently being installed at the Advanced Test Reactor. It is a two-loop test facility capable of performing Light Water Reactor (LWR) irradiations in prototypic coolant conditions. The two loops are being installed to be capable of both Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) pressure, temperature, and chemistry environments. Each loop is nominally dedicated as a BWR or PWR for simplicity of operations. In-reactor water loop testing that an I-Loop provides is key to the deployment of new accident tolerant fuel technologies and other advanced LWR fuel concepts. Currently, pressurized water loops are the only testing facilities available to test BWR fuel concepts. Their test environments are non-prototypic at higher pressure/temperature and at single-phase fluid flow conditions. This void in the LWR test bed capabilities is one that the I-Loop is uniquely situated to provide. This report discusses the mechanical design, thermal hydraulic calculations, and neutronic calculations of a proposed standard experiment of accident tolerant BWR fuel concepts. Mechanical design examines the geometry and features of the main components. Thermal hydraulic calculations examine the modeling and results of the two-phase flow options available. Lastly, neutronic calculations examine the Monte Carlo analysis of enrichment, heat rates, and flux spectrum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A microgravity boiling and convective condensation experiment

A boiling and condensing test article consisting of two straight tube boilers, one quartz and one stainless steel, and two 1.5 m long glass-in-glass heat exchangers, on 6 mm ID and one 10 mm ID, was flown on the NASA KC-135 0-G aircraft. Using water as the working fluid, the 5 kw boiler produces two phase mixtures of varying quality for mass flow rates between 0.005 and 0.1 kg/sec. The test section is instrumented at eight locations with absolute and differential pressure transducers and thermocouples. A gamma densitometer is used to measure void fraction, and high speed photography records the flow regimes. A three axis accelerometer provides aircraft acceleration data (+ or - 0.01G). Data are collected via an analog-to-digital conversion and data acquisition system. Bubbly, annular, and slug flow regimes were observed in the test section under microgravity conditions. Flow oscillations were observed for some operating conditions and the effect of the 2-G pullout prior to the 0-G period was observed by continuously recording data throughout the parabolas. A total fo 300 parabolas was flown.

Kachnik, Leo↗

A Report from the Thermal Science Research Center (TSRC)

A vertical flow loop was designed and assembled to determine the local (circumferential and axial) and mean wall temperature distributions for single-phase and two-phase (subcooled and saturated) downward flow in both uniformly-heated and single-side heated vertical channels. Freon-11 was used as the working fluid in order to directly relate and compare the results with a previous experimental campaign which employed this same working fluid. For a given steady-state experiment, the following parameters were held constant: (1) exit pressure, (2) inlet temperature, and (3) mass velocity. For a given configuration of the 2.2 m long cylindrical channel test section, which had a 1.2 m long heated section, the applied heat rate was varied from zero through successive quasi-steady states to a level which corresponded to localized film boiling in the test section. The measurements showed that the boiling curve changes significantly at higher mass velocities with respect to both the circumferential and axial directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential direction. The measurements point to the existence of a dry-out phenomenon occurring at multiple levels of the applied heat for the single-side heated channel. In comparing the heat transfer for horizontal channel flow with a vertically downward flow, the results show that significantly lower heat transfer occurs in the horizontal flow. However, this trend reverses as both the Reynolds number and the applied heat rate increase. Both the Liu-Winterton and Shah correlations were compared with the experimental data. The Shah correlation predicted the uniformly heated tube data better. When a thermal hydraulic diameter approach was used for the single-side heated case, the data at upstream locations for Z/L less than 0.5 was bounded above by the Liu-Winterton correlation and below by the Shah correlation. At Z/L = 0.5, the Shah correlation bounded the data; and for Z/L greater than 0.5, both correlations overpredicted the data with the Shah correlation being closest to the data. The present results indicate that additional correlational development is needed. In addressing some of the advanced space thermal management objectives concerning accommodating high heat fluxes in non-uniformly heated systems, a large battery of experiments 88 have been completed where local two-dimensional wall temperature variations were measured for both single-phase and two-phase flow in a single-side heated circular tube. As noted above, the results show significant axial and circumferential variations. Accurately accounting for such variations can result in optimized future advanced space, enhanced (high heat flux) thermal management systems.

Boyd, Ronald D.↗

Enhancement of Heat Transfer with Pool and Spray Impingement Boiling on Microporous and Nanowire Surface Coatings

The DOE National Renewable Energy Laboratory (NREL) is leading a national effort to develop next-generation cooling technologies for hybrid vehicle electronics. The goal is to reduce the size, weight, and cost of power electronic modules that convert direct current from batteries to alternating current for the motor, and vice versa. Aggressive thermal management techniques help to increase power density and reduce weight and volume, while keeping chip temperatures within acceptable limits. The viability of aggressive cooling schemes such as spray and jet impingement in conjunction with enhanced surfaces is being explored. Here, we present results from a series of experiments with pool and spray boiling on enhanced surfaces, such as a microporous layer of copper and copper nanowires, using HFE-7100 as the working fluid. Spray impingement on the microporous coated surface showed an enhancement of 100%-300% in the heat transfer coefficient at a given wall superheat with respect to spray impingement on a plain surface under similar operating conditions. Critical heat flux also increased by 7%-20%, depending on flow rates.

25 ENERGY STORAGE↗

Thermal effects in two-phase flow through face seals

When liquid is sealed at high temperature, it flashes inside the seal due to pressure drop and/or viscous heat dissipation. Two-phase seals generally exhibit more erratic behavior than their single phase counterparts. Thermal effects, which are often neglected in single phase seal analyses, play an important role in determining seal behavior under two-phase operation. It is necessary to consider the heat generation due to viscous shear, conduction into the seal rings and convection with the leakage flow. Analytical models developed work reasonably well at the two extremes - for low leakage rates when convection is neglected and for higher leakage rates when conduction is neglected. A preliminary model, known as the Film Coefficient Model, is presented which considers conduction and convection both, and allows continuous boiling over an extended region unlike the previous low-leakage rate model which neglects convection and always forces a discrete boiling interface. Another simplified, semi-analytical model, based on the assumption of isothermal conditions along the seal interafce, has been developed for low leakage rates. The Film Coefficient Model may be used for more accurate and realistic description.

Basu, Prithwish↗

Application of high-order numerical schemes and Newton-Krylov method to two-phase drift-flux model

This study concerns the application and solver robustness of the Newton-Krylov method in solving two-phase flow drift-flux model problems using high-order numerical schemes. In our previous studies, the Newton-Krylov method has been proven as a promising solver for two-phase flow drift-flux model problems. However, these studies were limited to use first-order numerical schemes only. Moreover, the previous approach to treating the drift-flux closure correlations was later revealed to cause deteriorated solver convergence performance, when the mesh was highly refined, and also when higher-order numerical schemes were employed. In this study, a second-order spatial discretization scheme that has been tested with two-fluid two-phase flow model was extended to solve drift-flux model problems. In order to improve solver robustness, and therefore efficiency, a new approach was proposed to treating the mean drift velocity of the gas phase as a primary nonlinear variable to the equation system. With this new approach, significant improvement in solver robustness was achieved. With highly refined mesh, the proposed treatment along with the Newton-Krylov solver were extensively tested with two-phase flow problems that cover a wide range of thermal-hydraulics conditions. Satisfactory convergence performances were observed for all test cases. Numerical verification was then performed in the form of mesh convergence studies, from which expected orders of accuracy were obtained for both the first-order and the second-order spatial discretization schemes. Finally, the drift-flux model, along with numerical methods presented, were validated with three sets of flow boiling experiments that cover different flow channel geometries (round tube, rectangular tube, and rod bundle), and a wide range of test conditions (pressure, mass flux, wall heat flux, inlet subcooling and outlet void fraction).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance testing of a two-phase interface heat exchanger

This paper describes the design and performance testing of a heat exchanger which interfaces separate two-phase ammonia thermal loops. The basic design involves a tube-in-tube concept, with boiling occurring in the inner tube and condensation in the outer tube. Eight such tubes are arranged in parallel. Testing has demonstrated that up to 8.2 kW of heat may be transferred across the heat exchanger when the saturation temperature difference between the systems is 5 C. Performance of the heat exchanger is affected primarily by the mass flow rate of ammonia in the liquid supply loop.

Mccabe, M. E., Jr.↗

Zero-Boil-Off Tank (ZBOT) Experiment: Ground-Based Validation of Self-Pressurization and Pressure Control Two-Phase CFD Model

Integral to all phases of NASA's projected space and planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. Cryogen vaporization due to heat leaks into the tank from its surroundings and support structure can cause self-pressurization relieved through venting. This has led to a desire to develop innovative pressure control designs based on mixing of the bulk tank fluid together with some form of active or passive cooling to allow storage of the cryogenic fluid with zero or reduced boil-off. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small scale tank pressurization and pressure control experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. The hardware for ZBOT-1 flew to ISS on the OA-7 flight in April 2017 and operations are planned to begin in September 2017, encompassing more than 90 tests. This paper presents preliminary results from ZBOT's ground-based research delineating both pressurization and pressure reduction trends in the sealed test tank. Tank self-pressurization tests are conducted under three modes: VJ heating, strip heating and simultaneous VJ and strip heating in attempt to simulate heat leaks from the environment, the support structure and both. The jet mixing pressure control studies are performed either from an elevated uniform temperature condition or from thermally stratified conditions following a self-pressurization run. Jet flow rates are varied from 2-25 cm/s spanning a range of jet Re number in laminar, transitional, and turbulent regimes and a range of Weber numbers covering no ullage penetration, partial penetration and complete ullage penetration and break-up (only in microgravity). Numerical prediction of a two-phase CFD model are compared to experimental 1g results to both validate the model and also indicate the effect of the residual non-condensable gas on evolution of pressure and temperature distributions in the tank during pressurization and pressure control.

microgravity evaporation condensatio↗

Falling-film thermosyphons: Application to water harvesting from humid gas streams

Water harvesting from humid gas streams is central to fresh-water production, desalination, and particulate removal from combustion gas streams. Two-phase thermosyphons are well suited for these applications due to their very low thermal resistance, but have several operating limits at the high heat flows required for such applications. This work introduces the falling-film thermosyphon for large-scale condensation applications. Working fluid is pumped to the top of the evaporator to provide the evaporating liquid film on the inner tube wall, rather than by vapor condensation. The flooding, dry-out and pool-boiling limits are eliminated, resulting in significantly higher maximum heat fluxes for the same physical evaporator size. Furthermore, the condenser no longer needs to be located vertically above the evaporator, which allows for a standard steam condenser to be used. A model for the condensation process in humid air was developed that estimates the fluid and heat transfer and is confirmed experimentally. Further benefits include the use of a high-thermal-conductivity polymer material for the evaporator section to minimize corrosion, and the ability to impose a temperature boundary condition on the evaporator, which is made possible due to the elimination of a liquid pool.

42 ENGINEERING↗

Physics based Reliability Models for Supercritical CO 2 Turbomachinery Components

CSP plants using sCO 2 power cycle can potentially achieve high thermal conversion efficiency at low capital cost due to compact turbo-machinery and other components. An sCO 2 expander and improved heat exchanger is expected to provide a major stepping stone for achieving CSP power at $0.06/kW-hr LCOE, energy conversion efficiency > 50%, and total power block cost < $1,200/kW installed. Hybrid gas bearings (HGB) and Dry gas seals (DGS) are two key components that are critical for robust and efficient operation of future sCO 2 power cycles. From a system perspective, HGBs can provide substantial benefits (~3 to 5%) to the modular CSP operation, while use of DGSs limits the leakage losses as well as the windage losses in the generator and can increase overall generator efficiency by ~ 8%. The life limiting mechanisms of HGBs and DGSs in high pressure, high temperature sCO2 environment were not well understood and hence this program aims at developing physics-based performance prediction and life prediction models for these two components. The output of the performance models serves as input to the life models. The performance models were validated using experimental data and using data from literature. DGS and HGB models have shed light on some risks associated with its operation in sCO2 expander and will guide more robust designs tailored towards sCO 2 cycle applications. A DGS was tested in 1MWe sCO2 turbo expander to study its performance and validate the performance models. To understand the effect of high pressures, high temperatures and sCO 2 environment on crack initiation, crack propagation and LCF/HCF life of these components, a novel experimental setup was developed. The LCF test data was used to calibrate and validate the life prediction models. The effect of sCO 2 corrosion on the life of Ni-based super-alloys is quantified using long duration experiments. Advanced microstructure and spectroscopic analyses conducted shed light on some key differences between IN718 and IN617 in terms of oxidation morphology, chemical species diffusion and trapping, the formation of protective corrosion resistant layers and changes in surface properties. A novel crack initiation model was developed which takes into account strain distribution, temperature, hold times and activation energy at the gas-metal interface and predicts the number of cycles to initiate the crack in the Inconel alloy. An advanced 3D fracture mechanics-based crack propagation model was also developed which takes into account the transient loading mission of the component and predict how fast the crack will grow and what will be its final shape and size. High energy X-Ray tomography measurements were conducted to study and validate 3D morphology of crack growth inside the specimen. These two models along with chemical kinetics models obtained from corrosion tests can be combined to predict the total life of the component under given long term operating conditions. A Bayesian Hybrid Modeling (BHM) probabilistic framework was developed to quantify uncertainty in physics-based performance models and in crack initiation and crack propagation models, to calibrate the models and to validate the models with statistical confidence. Advanced coupled physics multi-phase flow models were developed to study condensation, boiling and phase change behavior of CO 2 under various sCO 2 turbomachinery and heat exchanger conditions. A novel experimental setup was also designed to observe phase change of CO 2 during its transition across liquid-gas-supercritical state lines.

14 SOLAR ENERGY↗

Physics based Reliability Models for Supercritical CO 2 Turbomachinery Components

CSP plants using sCO 2 power cycle can potentially achieve high thermal conversion efficiency at low capital cost due to compact turbo-machinery and other components. An sCO 2 expander and improved heat exchanger is expected to provide a major stepping stone for achieving CSP power at 0.06/kW-hr LCOE, energy conversion efficiency > 50 % ,and total power block cost< $1,200/kW installed. Hybrid gas bearings (HGB) and Dry gas seals (DGS) are two key components that are critical for robust and efficient operation of future sCO 2 power cycles. From a system perspective, HGBs can provide substantial benefits (~3 to 5%) to the modular CSP operation, while use of DGSs limits the leakage losses as well as the windage losses in the generator and can increase overall generator efficiency by ~ 8%. The life limiting mechanisms of HGBs and DGSs in high pressure, high temperature sCO 2 environment were not well understood and hence this program aims at developing physics-based performance prediction and life prediction models for these two components. The output of the performance models serves as input to the life models. The performance models were validated using experimental data and using data from literature. DGS and HGB models have shed light on some risks associated with its operation in sCO 2 expander and will guide more robust designs tailored towards sCO 2 cycle applications. A DGS was tested in 1MWe sCO 2 turbo expander to study its performance and validate the performance models. To understand the effect of high pressures, high temperatures and sCO 2 environment on crack initiation, crack propagation and LCF/HCF life of these components, a novel experimental setup was developed. The LCF test data was used to calibrate and validate the life prediction models. The effect of sCO 2 corrosion on the life of Ni-based super-alloys is quantified using long duration experiments. Advanced microstructure and spectroscopic analyses conducted shed light on some key differences between IN718 and IN617 in terms of oxidation morphology, chemical species diffusion and trapping, the formation of protective corrosion resistant layers and changes in surface properties. A novel crack initiation model was developed which takes into account strain distribution, temperature, hold times and activation energy at the gas-metal interface and predicts the number of cycles to initiate the crack in the Inconel alloy. An advanced 3D fracture mechanics-based crack propagation model was also developed which takes into account the transient loading mission of the component and predict how fast the crack will grow and what will be its final shape and size. High energy X-Ray tomography measurements were conducted to study and validate 3D morphology of crack growth inside the specimen. These two models along with chemical kinetics models obtained from corrosion tests can be combined to predict the total life of the component under given long term operating conditions. A Bayesian Hybrid Modeling (BHM) probabilistic framework was developed to quantify uncertainty in physics-based performance models and in crack initiation and crack propagation models, to calibrate the models and to validate the models with statistical confidence. Advanced coupled physics multi-phase flow models were developed to study condensation, boiling and phase change behavior of CO 2 under various sCO 2 turbomachinery and heat exchanger conditions. A novel experimental setup was also designed to observe phase change of CO 2 during its transition across liquid-gas-supercritical state lines.

14 SOLAR ENERGY↗

Helium recovery system at IB3A

The growing demand for sustainable cryogenic operations at Fermilab has underscored the need to improve helium management, particularly at the Industrial Building 3A (IB3A) test facility. IB3A characterizes and tests superconductors, cables, and coils for projects such as the HL-LHC AUP and Mu2e, yet currently relies on 500 L Dewars whose boil-off is vented to atmosphere, wasting a critical, non-renewable resource and increasing the cost of testing. A project is therefore under way to link IB3A to an existing purification and liquefaction station in a neighboring building through a dedicated pipeline. Captured helium will be transferred, purified, reliquefied, and returned for reuse, cutting losses and operating costs. This paper details the first two project phases: "Design and Engineering" and "Procurement and Installation." The design phase finalizes pipeline specifications, establishes flow-control requirements, and resolves integration challenges with existing cryogenic infrastructure. The procurement and installation phase covers material sourcing, pipeline construction, and deployment of control and monitoring systems to assure reliable, efficient operation. Key technical hurdles-route optimization, pressure drop mitigation, and interface compatibility-are discussed alongside implemented solutions. Implementing the pipeline and upgrading IB3A will dramatically reduce helium consumption and therefore testing cost, strengthening Fermilab's capacity to support frontier science far into the future.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗