Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “band alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Fractional Chern insulators in magic-angle twisted bilayer graphene

Fractional Chern insulators (FCIs) are lattice analogues of fractional quantum Hall states that may provide a new avenue towards manipulating non-Abelian excitations. Early theoretical studies have predicted their existence in systems with flat Chern bands and highlighted the critical role of a particular quantum geometry. However, FCI states have been observed only in Bernal-stacked bilayer graphene (BLG) aligned with hexagonal boron nitride (hBN), in which a very large magnetic field is responsible for the existence of the Chern bands, precluding the realization of FCIs at zero field. By contrast, magic-angle twisted BLG supports flat Chern bands at zero magnetic field and therefore offers a promising route towards stabilizing zero-field FCIs. Here we report the observation of eight FCI states at low magnetic field in magic-angle twisted BLG enabled by high-resolution local compressibility measurements. The first of these states emerge at 5 T, and their appearance is accompanied by the simultaneous disappearance of nearby topologically trivial charge density wave states. We demonstrate that, unlike the case of the BLG/hBN platform, the principal role of the weak magnetic field is merely to redistribute the Berry curvature of the native Chern bands and thereby realize a quantum geometry favourable for the emergence of FCIs. Our findings strongly suggest that FCIs may be realized at zero magnetic field and pave the way for the exploration and manipulation of anyonic excitations in flat moiré Chern bands.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Twenty Years of Terra MODIS Spatial Performance Using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the NASA’s Earth Observing System Terra satellite has continued successful Earth-sensing operations for over 20 years. To aid in its mission in providing calibrated science data to the worldwide user community, the MODIS instrument is equipped with several on-board calibrators designed to measure changes in the instrument response over time. One such calibrator is the Spectro-Radiometric Calibration Assembly (SRCA), which can provide a source signal for radiometric, spectral, or spatial characterization. When commanded into its spatial calibration mode, the SRCA is able to produce light across the MODIS band spectral range (0.412μm to 14.2μm) at a variety of signal levels thanks to several internal halogen lamps, an IR glow bar, and a neutral density filter. This signal, used in combination with commanded sub-sample measurements of the MODIS detectors, provides a basis for determining changes in the spatial performance of the MODIS spectral bands. This work summarizes the spatial calibration process using the SRCA and presents 20 years of Terra MODIS spatial performance characterized through co-registration between MODIS bands, detectors, and focal plane assemblies. Results from pre-launch testing using the Integration and Alignment Collimator and the SRCA are incorporated in the history of the Terra MODIS mission-long spatial performance. We also note modifications to the spatial characterization methodology brought on by changes to the SRCA’s operational configuration and changes to the MODIS spectral band performance, particularly after the recovery from the safe-mode event in February 2016. Results are compared against the MODIS design specifications.

MODIS↗

L-Band System Engineering - Concepts of Use, Systems Performance Requirements, and Architecture

This document is being provided as part of ITT s NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract NNC05CA85C, Task 7: New ATM Requirements-Future Communications, C-band and L-band Communications Standard Development. Task 7 was motivated by the five year technology assessment performed for the Federal Aviation Administration (FAA) under the joint FAA-EUROCONTROL cooperative research Action Plan (AP-17), also known as the Future Communications Study (FCS). It was based on direction provided by the FAA project-level agreement (PLA FY09_G1M.02-02v1) for "New ATM Requirements-Future Communications." Task 7 was separated into two distinct subtasks, each aligned with specific work elements and deliverable items. Subtask 7-1 addressed C-band airport surface data communications standards development, systems engineering, test bed development, and tests/demonstrations to establish operational capability for what is now referred to as the Aeronautical Mobile Airport Communications System (AeroMACS). Subtask 7-2, which is the subject of this report, focused on preliminary systems engineering and support of joint FAA/EUROCONTROL development and evaluation of a future L-band (960 to 1164 MHz) air/ground (A/G) communication system known as the L-band digital aeronautical communications system (L-DACS), which was defined during the FCS. The proposed L-DACS will be capable of providing ATM services in continental airspace in the 2020+ timeframe. Subtask 7-2 was performed in two phases. Phase I featured development of Concepts of Use, high level functional analyses, performance of initial L-band system safety and security risk assessments, and development of high level requirements and architectures. It also included the aforementioned support of joint L-DACS development and evaluation, including inputs to L-DACS design specifications. Phase II provided a refinement of the systems engineering activities performed during Phase I, along with continued joint FAA/EUROCONTROL L-DACS development and evaluation support.

Henriksen, Stephen↗

Using spin alignment of inelastically excited nuclei in fast beams to assign spins: The spectroscopy of 13 O as a test case

Excited states in O 13 were investigated using inelastic scattering of an E / A = 69.5 MeV O 13 beam off of a Be 9 target. The excited states were identified in the invariant-mass spectra of the decay products. Both single-proton and sequential two-proton decays of the excited states were examined. Furthermore, for a number of the excited states, the protons were emitted with strong anisotropy where emissions transverse to the beam axis are favored. The measured proton-decay angular distributions were compared to predictions from distorted-wave Born-approximation calculations of the spin alignment which was shown to be largely independent of the excitation mechanism. The deduced O 13 level scheme is compared to ab initio no-core shell model with continuum predictions. The lowest-energy excited states decay isotropically consistent with predictions of strong proton 1 s 1 / 2 structure. Above these states in the level scheme, we observed a number of higher-spin states not predicted within the model. Possibly these are associated with rotational bands built on deformed cluster configurations predicted by antisymmetrized molecular dynamics calculations. The spin alignment mechanism is shown to be useful for making spin assignments and may have widespread use.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗

Extended Ly-alpha emission associated with 3C 294

Optical, IR, and radio observations of the powerful radio source 3C 294, which is surrounded by a large cloud of ionized gas, are presented. The galaxy is faint in the rest-frame UV, yet has a near-IR luminosity that is typical of radio galaxies at redshifts of order two. In contrast to the large extent of the ionized gas, the K-band image is quite compact. The emission-line cloud is closely aligned with the radio source axis and has an ionization state indicative of ionization by a nonstellar source. The velocity field of the gas has both large ordered motions and large turbulent components. The total mass required to keep the gas bound to the system is comparable to present-day massive galaxies and their halos. The velocity fields of the high-ionization lines are systematically different from Ly-alpha in a manner that is not easily understood.

Mccarthy, Patrick J.↗

Strain Sensitivity in Single Walled Carbon Nanotubes for Multifunctional Materials

Single walled carbon nanotubes represent the future of structural aerospace vehicle systems due to their unparalleled strength characteristics and demonstrated multifunctionality. This multifunctionality rises from the CNT's unique capabilities for both metallic and semiconducting electron transport, electron spin polarizability, and band gap modulation under strain. By incorporating the use of electric field alignment and various lithography techniques, a single wall carbon nanotube (SWNT) test bed for measurement of conductivity/strain relationships has been developed. Nanotubes are deposited at specified locations through dielectrophoresis. The circuit is designed such that the central, current carrying section of the nanotube is exposed to enable atomic force microscopy and manipulation in situ while the transport properties of the junction are monitored. By applying this methodology to sensor development a flexible single wall carbon nanotube (SWNT) based strain sensitive device has been developed. Studies of tensile testing of the flexible SWNT device vs conductivity are also presented, demonstrating the feasibility of using single walled HiPCO (high-pressure carbon monoxide) carbon nanotubes as strain sensing agents in a multi-functional materials system.

Heath, D. M.↗

Momentum-resolved superconducting energy gaps of Sr 2 RuO 4 from quasiparticle interference imaging

Sr 2 RuO 4 has long been the focus of intense research interest because of conjectures that it is a correlated topological superconductor. It is the momentum space ( k -space) structure of the superconducting energy gap Δ i ( k ) on each band i that encodes its unknown superconducting order parameter. However, because the energy scales are so low, it has never been possible to directly measure the Δ i ( k ) of Sr 2 RuO 4 . In this work, we implement Bogoliubov quasiparticle interference (BQPI) imaging, a technique capable of high-precision measurement of multiband Δ i ( k ). At T = 90 mK,we visualize a set of Bogoliubov scattering interference wave-vectors q j : j = 1 – 5 consistent with eight gap nodes/minima that are all closely aligned to the (±1, ±1) crystal lattice directions on both the α and β bands. Taking these observations in combination with other very recent advances in directional thermal conductivity, temperature-dependent Knight shift, time-reversal symmetry conservation, and theory, the BQPI signature of Sr 2 RuO 4 appears most consistent with Δ i ( k ) having d x 2 – y 2 ( B 1 g ) symmetry.

36 MATERIALS SCIENCE↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

Rocket measurement of auroral electron fluxes associated with field-aligned currents

A rocket-borne experiment using an electron and proton energy spectrometer is described, with particular reference to calibration and data reduction procedures. An upper limit of the measured proton flux is found to be 1,000,000 protons per sq cm sec sr keV. The characteristics of particle precipitation observed during flight over the auroral band are evaluated. The electron flux in regions of maximum flux tends to be the most field-aligned in the energy interval with the highest intensity.

Pazich, P. M.↗

Single crystal synthesis and magnetic properties of a Shastry-Sutherland lattice compound BaNd 2 ZnS 5

In this study, single crystals of a Shastry-Sutherland magnetic semiconductor, BaNd 2 ZnS 5 , were synthesized through a high-temperature solution growth technique. Physical properties were characterized by powder and single crystal x-ray diffraction, temperature- and field-dependent magnetization, and temperature-dependent specific heat measurements. BaNd 2 ZnS 5 orders antiferromagnetically at 2.9 K, with magnetic moments primarily aligned within the $ab$ -plane. Magnetic isothermal measurements show metamagnetic transitions at ~ 15 kOe for the [110] direction and ~ 21 kOe for the [100] direction. Estimated magnetic entropy suggests a double ground state for each neodymium ion.

36 MATERIALS SCIENCE↗

Synergistic effects of Al, Ga, and In doping on ZnO nanorod arrays grown via citrate-assisted hydrothermal technique for highly efficient and fast scintillator screens

To be used as efficient alpha particle scintillator in the fields of nuclear security, nuclear nonproliferation and high-energy physics, scintillator screens must have high light output and fast decay properties. While there has been a great deal of progress in scintillation efficiency, achieving fast decay time properties are still a challenge. In this work, the near band edge (NBE) UV luminescence and alpha particle induced scintillation properties of vertically aligned densely packed ZnO nanorods (NRs) doped with Al, Ga, and In have been thoroughly investigated. The high crystalline hexagonal wurtzite structure with a strong orientation through the c -axis plane (002) and aspect ratios in the range 13–22 have been observed for all ZnO NRs. Electron paramagnetic resonance (EPR) analysis exhibited paramagnetic signals at g ≈ 1.96 for all ZnO NRs. A cost effective green hydrothermal synthesis technique was employed to grow well-aligned NRs. Using citrate as an additive acting as a strong reducing agent in the solution during the crystal growth, defects on the surface are significantly suppressed, thereby enhancing the NBE UV emission. Significantly higher NBE UV emission was observed from the top surface of ZnO NRs in cathodoluminescence (CL) microscopy. Results show that citrate assisted donor doping of ZnO NRs not only reduces the defect emission and NBE self-absorption, but also induces fast decay time (~ 600–700 ps), which makes ZnO NRs a good candidate for fast alpha particle scintillator screens used in associated particle imaging for time and direction tagging of individual neutrons generated in D–T and D–D neutron generators.

36 MATERIALS SCIENCE↗

Signal averaging technique for noninvasive recording of late potentials in patients with coronary artery disease

An advanced non invasive signal averaging technique was used to detect late potentials in two groups of patients: Group A (24 patients) with coronary artery disease (CAD) and without sustained ventricular tachycardia (VT) and Group B (8 patients) with CAD and sustained VT. Recorded analog data were digitized and aligned using a cross correlation function with fast Fourier transform schema, averaged and band pass filtered between 60 and 200 Hz with a non-recursive digital filter. Averaged filtered waveforms were analyzed by computer program for 3 parameters: (1) filtered QRS (fQRS) duration (2) interval between the peak of the R wave peak and the end of fQRS (R-LP) (3) RMS value of last 40 msec of fQRS (RMS). Significant change was found between Groups A and B in fQRS (101 -/+ 13 msec vs 123 -/+ 15 msec; p < .0005) and in R-LP vs 52 -/+ 11 msec vs 71-/+18 msec, p <.002). We conclude that (1) the use of a cross correlation triggering method and non-recursive digital filter enables a reliable recording of late potentials from the body surface; (2) fQRS and R-LP durations are sensitive indicators of CAD patients susceptible to VT.

NASA Discipline Cardiopulmonary↗

Revealing the Magnetic Field Geometry of Gamma-Ray Binary PSR B1259-63 Via X-Ray Polarimetry

PSR B1259-63 (PSR 1259) is a radio pulsar with a spin period of ~48 ms, in a binary system with a massive, emission-line star of spectral type O9.5Ve (Figs 1 and 2). The star, LS 2883, is commonly referred to as a Be-type star, with optical spectra revealing a dense equatorial outflow and isotropic wind that forms an equatorial disk, purportedly inclined with respect to the orbital plane. The pulsar is in a highly eccentric orbit (e~0.87, P~3.38 years), around LS 2883, plunging through this circumstellar twice at about 16 days and 13 days before and after periastron, respectively. This interaction of the pulsar wind wind with the stellar outflow, produces TeV gamma rays as a result of highly energetic particles being efficiently accelerated, producing synchrotron radiation in the X-ray and soft gamma-ray bands, in a time-varying shock. X-ray polarization to be aligned perpendicular to the magnetic field for synchrotron radiation.

Oliver J Roberts↗

Field-aligned particle currents near an auroral arc.

A Nike-Tomahawk rocket equipped to measure electric and magnetic fields and charged particles from a few eV to several hundred keV energy was flown into an auroral band on April 11, 1970. The purpose of this flight was to obtain evidence of the low-energy electrons and protons that constitute a field-aligned sheet current, and also to obtain the magnetic signature of such a current and the electric field in and near the auroral-arc electric current system. Particular attention was given to a sudden increase in the field-aligned current associated with a prior sudden increase in the electric field and a sudden change in the magnetic field, all occurring near the edge of a visual auroral arc. Data obtained are discussed and analyzed; they present an important contribution to the problem of mapping of atmospheric auroral phenomena to the magnetospheric equatorial plane.

Choy, L. W.↗

Directional dependence of the event-by-event neutron-γ multiplicity correlations in 252 Cf(sf)

We differentiate the event-by-event n-γ multiplicity data from 252 Cf(sf) with respect to the energies of the emitted particles as well as their relative angles of emission. We determine that neutron emission enhances γ-ray emission around 0:7 and 1:2 MeV, but the only directional alignment was observed for E γ ≤ 0:7 MeV and tended to be parallel and antiparallel to neutrons emitted in the same event. The emission of γ rays at other energies was determined to be nearly isotropic. The presence of the emission and alignment enhancements is explained by positive correlations between neutron emission and quadrupole γ-ray emission along rotational bands in the de-exciting fragments. This observation corroborates the hypothesis of positive correlations between the angular momentum of a fragment and its intrinsic excitation energy. The results of this work are especially relevant in view of the recent theoretical and experimental interest in the generation of angular momentum in fission. Specifically, we have determined an alignment of the fragments angular momenta in a direction perpendicular to the direction of motion. We interpret the lack of n-γ angular correlations for fission fragments near closed shells as a weakening of the alignment process for spherical nuclei. Lastly, we have observed that statistical γ rays are emitted isotropically, indicating that the average angular momentum removed by this radiation is small. These results, and the analysis tools presented in this work, represent a stepping stone for future analysis of n-γ emission correlations and their connection to angular momentum properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single domain spectroscopic signatures of a magnetic kagome metal

Magnetic kagome metals host complex electronic states and real-space magnetic textures, but their small and temperature-dependent magnetic domains make experimental access difficult. Here we show that micro-focused circular-dichroic photoemission spectroscopy enables spectroscopic access to individual magnetic domains in the kagome metal DyMn 6 Sn 6 at low temperature. By tuning to element-specific electronic states, we image domain contrast associated with Dy 4f levels and detect corresponding signatures from Mn core states. The energy dependence of the dichroic response is consistent with modeling and indicates ferrimagnetic alignment between Dy and Mn local moments. Measurements of Mn 3d-derived valence bands, supported by first-principles calculations, reveal features related to orbital magnetization. These results establish element- and orbital-resolved spectroscopy of single magnetic domains and enable studies of magnetic textures and electronic structure in complex magnetic quantum materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗