Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Measurement of the inclusive and differential $t\overline{t}γ$ cross sections in the single-lepton channel and EFT interpretation at $\sqrt{s}$ = 13 TeV

The production cross section of a top quark pair in association with a photon is measured in proton-proton collisions at a center-of-mass energy of 13 TeV. The data set, corresponding to an integrated luminosity of 137 fb -1 , was recorded by the CMS experiment during the 2016–2018 data taking of the LHC. The measurements are performed in a fiducial volume defined at the particle level. Events with an isolated, highly energetic lepton, at least three jets from the hadronization of quarks, among which at least one is b tagged, and one isolated photon are selected. The inclusive fiducial $t\overline{t}γ$ cross section, for a photon with transverse momentum greater than 20 GeV and pseudorapidity |η| < 1.4442, is measured to be 798 ± 7(stat) ± 48(syst) fb, in good agreement with the prediction from the standard model at next-to-leading order in quantum chromodynamics. The differential cross sections are also measured as a function of several kinematic observables and interpreted in the framework of the standard model effective field theory (EFT), leading to the most stringent direct limits to date on anomalous electromagnetic dipole moment interactions of the top quark and the photon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Interpreting Sunyaev–Zel’dovich observations with MillenniumTNG: mass and environment scaling relations

ABSTRACT Sunyaev–Zel’dovich (SZ) measurements can dramatically improve our understanding of the intergalactic medium and the role of feedback processes in galaxy formation, allowing us to calibrate important astrophysical systematics in cosmological constraints from weak lensing galaxy clustering surveys. However, the signal is only measured in a two-dimensional projection, and its correct interpretation relies on understanding the connection between observable quantities and the underlying intrinsic properties of the gas, in addition to the relation between the gas and the underlying matter distribution. One way to address these challenges is through the use of hydrodynamical simulations such as the high-resolution, large-volume MillenniumTNG suite. We find that measurements of the optical depth, τ, and the Compton-y parameter, Y, receive large line-of-sight contributions that can be removed effectively by applying a compensated aperture photometry filter. In contrast with other τ probes (e.g. X-rays and fast radio bursts), the kinematic SZ-inferred τ receives most of its signal from a confined cylindrical region around the halo due to the velocity decorrelation along the line of sight. Additionally, we perform fits to the Y–M and τ–M scaling relations and report best-fitting parameters adopting the smoothly broken power law formalism. We note that subgrid physics modelling can broaden the error bar on these by 30 per cent for intermediate-mass haloes (${\sim }10^{13} \, {\rm M}_{\odot }$). The scatter of the scaling relations can be captured by an intrinsic dependence on concentration and an extrinsic dependence on tidal shear. Finally, we comment on the effect of using galaxies rather than haloes in observations, which can bias the inferred profiles by ∼20 per cent for L* galaxies.

Hadzhiyska, Boryana (ORCID:0000000223123121)↗

dlppi2 (b1)

The Doppler lidar (DL) is an active remote-sensing instrument that provides range- and time-resolved measurements of the line-of-sight component of air velocity (i.e., radial velocity) and attenuated aerosol backscatter. The DL operates in the near-infrared and is sensitive to backscatter from atmospheric aerosol, which are assumed to be ideal tracers of atmospheric wind fields. The DL works by transmitting short pulses of infrared laser light into the atmosphere. Atmospheric aerosols scatter a small fraction of that light energy back to the transceiver, where it is collected and recorded as a time-resolved signal. From the delay between the outgoing pulse and the backscattered signal, the instrument infers the distance to the scattering volume. Coherent detection is used to measure the Doppler frequency shift of the backscatter signal. This is accomplished by mixing the backscatter signal with a reference laser beam (i.e., local oscillator) of known frequency. The onboard signal processor then determines the Doppler frequency shift from the spectrum of the mixed signal. The Doppler frequency shift and thus the radial air velocity is determined from the peak of the Doppler spectrum. The attenuated backscatter is determined from the energy content of the Doppler spectra. The DL provides accurate measurements of radial velocity in regions of the atmosphere where aerosol concentrations are high enough to ensure good signal-to-noise ratio. Thus, valid data are usually limited to the atmospheric boundary layer where aerosol is ubiquitous. Valid measurements can also be obtained in elevated aerosol layers or in optically thin clouds above the boundary layer. Most of the ARM DLs have full upper-hemispheric scanning capability, enabling 3D mapping of turbulent flows in the atmospheric boundary layer. With the scanner pointed vertically, the DL provides height- and time-resolved measurements of vertical velocity.

54 ENVIRONMENTAL SCIENCES↗

Jets from shocked metal surfaces with grooves: Missing experiments

Many studies have investigated the mass outflows generated when a planar shock transits an imperfect (“defected”) metal surface, where the defects are symmetric triangular or sinusoidal grooves. Yet a fundamental question remains unanswered: how does the quantity of outflow mass and its maximum velocity vary as a function of the groove cross-sectional aspect ratio? We identify two sets of missing experiments that must be addressed to answer the question. The aspect ratio (groove depth over width) is equivalently represented by θ, the cross-sectional half angle, or by η 0 k, the amplitude multiplied by an effective wavenumber. Low θ (high η 0 k) grooves comprise the first set of missing experiments, which are necessary to determine the validity of theoretical predictions of the nonlinear regime (η 0 k ≥ 1, θ < 57.5°). The second set of missing experiments are those in which the volume of the groove (or equivalently, the axial cross-sectional area) has been held constant as θ or η 0 k are varied. Such experiments are necessary to independently measure the effects of variations in groove volume and groove aspect ratio on the resulting jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Jets from shocked metal surfaces with grooves: Missing experiments

Many studies have investigated the mass outflows generated when a planar shock transits an imperfect (“defected”) metal surface, where the defects are symmetric triangular or sinusoidal grooves. Yet a fundamental question remains unanswered: how does the quantity of outflow mass and its maximum velocity vary as a function of the groove cross-sectional aspect ratio? We identify two sets of missing experiments that must be addressed to answer the question. The aspect ratio (groove depth over width) is equivalently represented by θ, the cross sectional half angle, or by η 0 k, the amplitude multiplied by an effective wavenumber. Low θ (high η 0 k) grooves comprise the first set of missing experiments, which are necessary to determine the validity of theoretical predictions of the nonlinear regime (η 0 k ≥ 1, θ < 57.5°). The second set of missing experiments are those in which the volume of the groove (or equivalently, the axial cross-sectional area) has been held constant as θ or η 0 k are varied. Such experiments are necessary to independently measure the effects of variations in groove volume and groove aspect ratio on the resulting jets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bubbler Design Updates for Nuclear Safeguards Applications

The accurate monitoring of molten salt compositions is crucial for nuclear safeguards, particularly in the context of mixtures used in molten salt reactors as well as pyroprocessing. However, for nuclear material accountancy in actinide bearing molten salts, the solution volume is also needed to determine the total mass of material in the salt. This study explores the effectiveness of two bubbler configurations, triple and single, for density and level measurements within these molten salts for salt volume determinations. The triple bubbler system utilizes three gas dip-tubes strategically positioned at different heights within the molten salt. With this design, the molten salt level, density, and surface tension can be determined simultaneously. The single bubbler configuration, on the other hand, relies on a dynamic single dip-tube to determine the density and level. Both configurations will be tested in aqueous solutions as well as in LiCl-KCl and NaCl-MgCl2 molten salts between 450°C and 750°C. Dip-tube diameters and bubbler inferences will also be explored. A new bubbler is being designed based on results. The findings of this study will provide valuable insights into the optimal bubbler design and configuration for ensuring representative sampling of molten salt compositions in nuclear safeguards applications. This will contribute to enhanced accountability and transparency in the monitoring of actinide bearing molten salts, promoting nuclear safeguards objectives.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation-induced alteration of sandstone concrete aggregate

This study investigates the alteration of felsic sandstone-type rock, which is used as a coarse aggregate in concrete, subject to the effects of gamma-ray and neutron irradiation. The effects of three gamma-ray doses (27, 55, and 108 MGy) and four neutron fluence levels (1.22, 2.19, 6.99, and 14.30 × 10 19 n/cm 2 , $E$ ≥ 0.01 MeV) were investigated. Quartz and albite were found to be the major rock-forming minerals, with microcline intermediates, chlorite, and muscovite as the minors. Gamma rays caused no significant changes to the physical properties of the sandstone aggregates, even at high doses (108 MGy). In contrast, neutron irradiation caused alterations that became more pronounced at higher neutron fluences. The solid was confirmed to expand through metamictization of the rock-forming minerals. Quartz and muscovite were the most affected phases, whereas albite and microcline intermediates were only slightly affected, and chlorite was almost unaffected. The decrease in density was measured by He and water pycnometry, and this value was almost reproduced by calculations using the rock-forming mineral composition of the pristine sample measured using X-ray powder diffraction/Rietveld analysis and the cell volume change of the major forming minerals. In addition, light optical microscopy and scanning electron microscopy images confirmed the presence of intergranular and intragranular cracks. Intergranular cracks appeared to have initiated from the quartz grains, which expanded significantly. The intragranular cracks were frequently observed in the albite and microcline intermediates. These cracks can be described as radial cracks starting from the expanding quartz, caused by enforced displacement for deformation consistency with quartz expansion. The crack area ratio quantified by SEM image analysis corresponds to the discrepancy of the volume expansion difference calculated by He or water pycnometry and dimensional change measurements. In conclusion, an evaluation of solid expansion and crack openings in aggregates is important to estimate concrete degradation.

36 MATERIALS SCIENCE↗

Depth Thermography: Noninvasive 3D Temperature Profiling Using Infrared Thermal Emission

Here, we introduce a technique based on infrared thermal emission, termed depth thermography, that can remotely measure the temperature distribution beneath the surface of certain objects. Depth thermography utilizes the thermal-emission spectrum in the semitransparent spectral region of the target object to extract its temperature as a function of depth, in contrast with conventional thermography, which uses the spectrally integrated thermally emitted power to measure the surface temperature. Coupled with two-dimensional imaging, for example using an infrared hyperspectral camera or scanning a single-pixel spectrometer, this technique can yield volumetric temperature distributions. Furthermore, we carried out a proof-of-concept experiment on an asymmetrically heated fused-silica window, extracting the temperature distribution throughout the sample. Depth thermography may enable noncontact volumetric temperature measurements of microscopic objects such as multilayer electronic devices or macroscopic volumes of liquids and gases, as well as simultaneous all-optical measurements of optical and thermal properties of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The MuFusE large-volume diamond anvil cell for exploring muon-catalyzed fusion at higher pressures and temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion (μCF) Experiment (MuFusE), enabling the compression and heating of deuterium–tritium (d–t) mixtures to pressures and temperatures needed to advance μCF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm 3 at liquid density, pressures up to 933 MPa and temperatures up to 400 K—benchmarks that significantly exceed previously reported limits for static d–t targets.

Kalow, J. D. [Acceleron Fusion, Inc., Cambridge, M↗

Radar Retrieval Evaluation and Investigation of Dendritic Growth Layer Polarimetric Signatures in a Winter Storm

Abstract This study evaluates ice particle size distribution and aspect ratio φ Multi-Radar Multi-Sensor (MRMS) dual-polarization radar retrievals through a direct comparison with two legs of observational aircraft data obtained during a winter storm case from the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) campaign. In situ cloud probes, satellite, and MRMS observations illustrate that the often-observed K dp and Z DR enhancement regions in the dendritic growth layer can either indicate a local number concentration increase of dry ice particles or the presence of ice particles mixed with a significant number of supercooled liquid droplets. Relative to in situ measurements, MRMS retrievals on average underestimated mean volume diameters by 50% and overestimated number concentrations by over 100%. IWC retrievals using Z DR and K dp within the dendritic growth layer were minimally biased relative to in situ calculations where retrievals yielded −2% median relative error for the entire aircraft leg. Incorporating φ retrievals decreased both the magnitude and spread of polarimetric retrievals below the dendritic growth layer. While φ radar retrievals suggest that observed dendritic growth layer particles were nonspherical (0.1 ≤ φ ≤ 0.2), in situ projected aspect ratios, idealized numerical simulations, and habit classifications from cloud probe images suggest that the population mean φ was generally much higher. Coordinated aircraft radar reflectivity with in situ observations suggests that the MRMS systematically underestimated reflectivity and could not resolve local peaks in mean volume diameter sizes. These results highlight the need to consider particle assumptions and radar limitations when performing retrievals. significance statement Developing snow is often detectable using weather radars. Meteorologists combine these radar measurements with mathematical equations to study how snow forms in order to determine how much snow will fall. This study evaluates current methods for estimating the total number and mass, sizes, and shapes of snowflakes from radar using images of individual snowflakes taken during two aircraft legs. Radar estimates of snowflake properties were most consistent with aircraft data inside regions with prominent radar signatures. However, radar estimates of snowflake shapes were not consistent with observed shapes estimated from the snowflake images. Although additional research is needed, these results bolster understanding of snow-growth physics and uncertainties between radar measurements and snow production that can improve future snowfall forecasting.

Meteorology & Atmospheric Sciences↗

Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small-angle X-ray microdiffraction from fibrils embedded in tissue thin sections

Small-angle X-ray scattering (SAXS) from fibrils embedded in a fixed, thin section of tissue includes contributions from the fibrils, the polymeric matrix surrounding the fibrils, other constituents of the tissue, and cross-terms due to the spatial correlation between fibrils and neighboring molecules. This complex mixture severely limits the amount of information that can be extracted from scattering studies. However, availability of micro- and nano-beams has made the measurement of scattering from very small volumes possible, which, in some cases, may be dominated by a single fibrillar constituent. In such cases, information about the predominant species may be accessible. Nevertheless, even in these cases, the correlations between the positions of fibrils and other constituents have a significant impact on the observed scattering. Here, strategies are proposed to extract partial information about fibril structure and tissue organization on the basis of SAXS from samples of this type. It is shown that the spatial correlation function of the fibril in the direction perpendicular to the fibril axis can be computed and contains information about the predominant fibril structure and the organization of the surrounding tissue matrix. This has significant advantages over approaches based on techniques developed for X-ray solution scattering. Examples of correlation calculations in different types of samples are given to demonstrate the information that can be obtained from these measurements.

36 MATERIALS SCIENCE↗

Analysis of Rig Parameter Data Using Drilling Process Modeling Constraints, Volume 5: Utah FORGE Well 16B(78)-32

Drill rig parameter measurements are routinely used during deep well construction to monitor and guide drilling conditions for improved performance and reduced costs. While insightful into the drilling process, these measurements are of reduced value without a standard to aid in data evaluation and decision making. In the main body of this work (Volume 1), a method is demonstrated whereby rock reduction model constraints are used to interpret drilling response parameters; the method could be applied in real-time to improve decision-making in the field and to further discern technology performance during post-drilling evaluations. Drilling parameters are evaluated using laboratory-validated rock reduction models for predicting the phenomenological response of drag bits (Detournay and Defourny, 1992) in computational algorithms. The method presented has applicability to development of advanced analytics on future geothermal wells using real-time electronic data recording for improved performance and reduced drilling costs. A drilling cost model is also used to show the tradeoff between rate of penetration and bit life and the influence on interval drilling costs. Details of the bit specifications and performance are cataloged in an independent volume, documented under separate cover, for each of the four wells, and include Volume 2: Utah FORGE 16A(78)-32; Volume 3: Utah FORGE 56-32; Volume 4: Utah FORGE 78B-32 and Volume 5: Utah FORGE 16B(78)-32.

15 GEOTHERMAL ENERGY↗

Polyethylene density uncertainty in the simulation of neutron detectors

Simulations with the Monte Carlo N-Particle® (MCNP®) code are frequently used to study neutron coincidence counters for international safeguards. Reducing sources of uncertainty enables more accurate simulations, which reduces the need for expensive or impossible measurements. Accurately specifying the density of polyethylene is crucial for accurate simulations. The density of polyethylene ranges from 0.88 to 0.97 g/cm 3 and high-density polyethylene (HDPE) ranges from about 0.944 to 0.965 g/cm 3 . The density of a specific detector should be measured exactly for the best simulations. Here, the density of the blue/white Active Well Coincidence Counter (AWCC) bulk polyethylene was measured to be 0.9594 +- 0.0013 g/cm 3 at 1-sigma confidence. The density was calculated from repeated measurements of the various polyethylene dimensions for volume, and weighing the polyethylene for the mass. The AWCC neutron detection efficiency was simulated for each polyethylene density. The relative range of efficiencies (3σ) was 3.4% for unspecified polyethylene, 0.9% for HDPE, and 0.3% for the measured density. The impact of modeling small features such as screws was also studied and was found to be a negligible 0.2%. Measuring polyethylene density can reduce its role in uncertainty from one of the largest to one of the smallest contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uniformity and volume-representativity of consecutive submillimetre wafers of shale for SANS and USANS investigations

(Ultra) Small Angle Neutron Scattering (SANS/USANS) is a non-destructive technique suitable for characterization of porous structures from nano- to micro-pore size (1 nm to 20 μm), which has been widely used to characterize accessible and inaccessible porosity in tight unconventional hydrocarbon reservoirs (e.g., shales). Here, in this study, SANS and USANS are used to examine the degree of nano- to micropore uniformity of the rock body on sub-millimetre to centimetre scale. This study presents a test of the hypothesis of volume representativity of pore structure information measured by SANS and USANS for shale wafers (0.22–1 mm) cut from six North American unconventional shale cores of different maturities (New Albany Shale and Marcellus Shale). Experimental reproducibility of USANS is further investigated for two wafers measured using various acquisition times. All samples show that fluctuations of the relative intensity generally decrease from the USANS Q-range (pore size from around 200 nm to 20 μm) to most of the SANS Q-range (pore size from around 5 nm to 700 nm), and peaks in the SANS large-Q region (for pores smaller than about 5 nm). There is a positive correlation between the spatial fluctuation of the relative SANS intensity and the scattering power of shales. In addition, the scattering intensity and its fluctuations is larger for the less mature shale cores. Shale is known to be highly heterogenous and the hypothesis of uniformity does not apply at sub-millimetre scale even for samples that appear homogeneous at visual inspection. This study presents an approach to minimise the variation through sample selection, data interpretation methodology and instrumental reproducibility tests. The best values of the microstructural spatial uniformity for the apparently homogeneous sections of a core (i.e., the SANS and USANS intensity variation) is less than ±10%.

01 COAL, LIGNITE, AND PEAT↗

Specifications of FIPD Fission Gas Release Data

All fission gas release data stored in the Fuels Irradiation & Physics Database (FIPD) was originally measured using the Gas Assay, Sample and Recharge (GASR) System in the Hot Fuel Examination Facility (HFEF). It is therefore called GASR data in FIPD. During the measurement of a sample, such as an irradiated EBR-II fuel element/capsule, a pinhole-sized region near the top of the element plenum was melted by a laser. Plenum gas then expanded into a calibrated volume (note: in this document, “sample” and “capsule/element” are used interchangeably consistent with GASR documents in FIPD). The pressure rise in the volume was recorded. Helium backfilling and expansion was then performed to determine the sample (e.g., fuel element plenum) volume using Boyle’s Law and assuming ideal gas behavior at constant temperature. With the plenum volume and the recorded pressure rise, the sample (e.g., fuel element plenum) pressure was derived with assumption of ideal gas law behavior. The plenum volume and pressure as well as the cladding temperature during the measurement were collected (GASR data in FIPD). Other records associated with the fission gas release data include: raw GASR data records including volumes and post-puncture pressures of seal head/sealing head and manifold, calibration data, backfilling gas pressure data, and the data analysis records. A sample(s) of the fission gas released from the plenum was collected by the GASR system into sample bottles. The chemical and isotopic composition of the gas sample was analyzed separately from GASR data, and will be discussed in a separate specification. The plenum volume, pressure, and cladding temperature during the measurement are typically utilized to determine the number of moles of gas in the plenum. This quantity is often compared to the number of moles of gas generated by fission events. However, calculating these values and their associated uncertainty is beyond the scope of this document, as it necessitates additional assumptions. The most important document to understand the FIPD fission gas data is the GASR operational manual (title: Gas Assay, Sample and Recharge System (GASR) operation and maintenance manual, HFEF/N OMM 4381, DOC. NO. W0018-0032-ES-00). This manual provides: (1) description of the GASR and the functions of each component (laser drilling, welding, seal head/sealing head, manifold, vacuum system, sample system, purge and gas tag system, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details relating to the structure and operation of the GASR. Note that the original GASR operated until 2020. A new GASR with the same design and measurement methodology was installed in 2021. The specifications of the GASR presented on the HFEF website at this time are consistent with the ones given in the operational manual. The methods to calculate the plenum volume and pressures were not included in the operational manual, but were recorded in the legacy data analysis files. Details of the methods are given in Chapter 3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of δ 13 C analyses of individual foraminifer ( Orbulina universa ) shells by secondary ion mass spectrometry and gas source mass spectrometry

Rationale: The use of secondary ion mass spectrometry (SIMS) to perform micrometer-scale in situ carbon isotope (δ 13 C) analyses of shells of marine microfossils called planktic foraminifers holds promise to explore calcification and ecological processes. The potential of this technique, however, cannot be realized without comparison to traditional whole-shell δ 13 C values measured by gas source mass spectrometry (GSMS). Methods: Paired SIMS and GSMS δ 13 C values measured from final chamber fragments of the same shell of the planktic foraminifer Orbulina universa are compared. The SIMS–GSMS δ 13 C differences (Δ 13 C SIMS-GSMS ) were determined via paired analysis of hydrogen peroxide-cleaned fragments of modern cultured specimens and of fossil specimens from deep-sea sediments that were either untreated, sonicated, and cleaned with hydrogen peroxide or vacuum roasted. After treatment, fragments were analyzed by a CAMECA IMS 1280 SIMS instrument and either a ThermoScientific MAT-253 or a Fisons Optima isotope ratio mass spectrometer (GSMS). Results: Paired analyses of cleaned fragments of cultured specimens (n = 7) yield no SIMS–GSMS δ 13 C difference. However, paired analyses of untreated (n = 18) and cleaned (n = 12) fragments of fossil shells yield average Δ 13 C SIMS-GSMS values of 0.8‰ and 0.6‰ (±0.2‰, 2 SE), respectively, while vacuum roasting of fossil shell fragments (n = 11) removes the SIMS–GSMS δ 13 C difference. Conclusions: The noted Δ 13 C SIMS-GSMS values are most likely due to matrix effects causing sample–standard mismatch for SIMS analyses but may also be a combination of other factors such as SIMS measurement of chemically bound water. The volume of material analyzed via SIMS is ~10 5 times smaller than that analyzed by GSMS; hence, the extent to which these Δ 13 C SIMS-GSMS values represent differences in analyte or instrument factors remains unclear.

58 GEOSCIENCES↗