Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Unreliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Exact minimal-state system reliability analysis

System reliability equation, an exact function of component reliabilities, for a system with a finite number of points is derived from the minimal states which are found by logical analysis of the configuration. The numerical value is obtained by substituting the component reliabilities or unreliabilities.

Locks, M. O.↗

MSPI False Indication Probability Simulations

This paper examines false indication probabilities in the context of the Mitigating System Performance Index (MSPI), in order to investigate the pros and cons of different approaches to resolving two coupled issues: (1) sensitivity to the prior distribution used in calculating the Bayesian-corrected unreliability contribution to the MSPI, and (2) whether (in a particular plant configuration) to model the fuel oil transfer pump (FOTP) as a separate component, or integrally to its emergency diesel generator (EDG). False indication probabilities were calculated for the following situations: (1) all component reliability parameters at their baseline values, so that the true indication is green, meaning that an indication of white or above would be false positive; (2) one or more components degraded to the extent that the true indication would be (mid) white, and “false” would be green (negative) or yellow (negative) or red (negative). In key respects, this was the approach taken in NUREG-1753. The prior distributions examined were the constrained noninformative (CNI) prior used currently by the MSPI, a mixture of conjugate priors, the Jeffreys noninformative prior, a nonconjugate log(istic)-normal prior, and the minimally informative prior investigated in (Kelly et al., 2010). The mid-white performance state was set at ?CDF = ?10 ? 10-6/yr. For each simulated time history, a check is made of whether the calculated ?CDF is above or below 10-6/yr. If the parameters were at their baseline values, and ?CDF > 10-6/yr, this is counted as a false positive. Conversely, if one or all of the parameters are set to values corresponding to ?CDF > 10-6/yr but that time history’s ?CDF < 10-6/yr, this is counted as a false negative indication. The false indication (positive or negative) probability is then estimated as the number of false positive or negative counts divided by the number of time histories (100,000). Results are presented for a set of base case parameter values, and three sensitivity cases in which the number of FOTP demands was reduced, along with the Birnbaum importance of the FOTP.

99 GENERAL AND MISCELLANEOUS↗

Comparative analysis of data base management systems

A study to determine if the Remote File Inquiry (RFI) system would handle the future requirements of the user community is discussed. RFI is a locally written and locally maintained on-line query/update package. The current and future on-line requirements of the user community were studied. Additional consideration was given to the types of data structuring the users required. The survey indicated the features of greatest benefit were: sort, subtotals, totals, record selection, storage of queries, global updating and the ability to page break. The major deficiencies were: one level of hierarchy, excessive response time, software unreliability, difficult to add, delete and modify records, complicated error messages and the lack of ability to perform interfield comparisons. Missing features users required were: formatted screens, interfield comparions, interfield arithmetic, multiple file access, security and data integrity. The survey team recommended Kennedy Space Center move forward to state-of-the-art software, a Data Base Management System which is thoroughly tested and easy to implement and use.

Smith, R.↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

Relatively scaled ECE temperature profiles of KSTAR plasmas

A scheme to obtain relatively scaled profiles of electron cyclotron emission (ECE) temperature directly from uncalibrated raw radiometer data is proposed and has been tested for the 2009 campaign KSTAR plasmas. The proposed method utilizes a position controlled system to move the plasma adiabatically and compares ECE radiometer channels at the same relative radial positions assuming the profile consistency during the adiabatic change. This scaling method is an alternative solution when an absolute calibration is unreliable or too time consuming. The application to the two dimensional ECE imaging data, wherein calibration is extremely difficult, may also prove to be useful.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the SURE Program, phase 1

Presented are the results of the first phase in the validation of the SURE (Semi-Markov Unreliability Range Evaluator) program. The SURE program gives lower and upper bounds on the death-state probabilities of a semi-Markov model. With these bounds, the reliability of a semi-Markov model of a fault-tolerant computer system can be analyzed. For the first phase in the validation, fifteen semi-Markov models were solved analytically for the exact death-state probabilities and these solutions compared to the corresponding bounds given by SURE. In every case, the SURE bounds covered the exact solution. The bounds, however, had a tendency to separate in cases where the recovery rate was slow or the fault arrival rate was fast.

Dotson, Kelly J.↗

Error detection process - Model, design, and its impact on computer performance

An analytical model is developed for computer error detection processes and applied to estimate their influence on system performance. Faults in the hardware, not in the design, are assumed to be the potential cause of transition to erroneous states during normal operations. The classification properties and associated recovery methods of error detection are discussed. The probability of obtaining an unreliable result is evaluated, along with the resulting computational loss. Error detection during design is considered and a feasible design space is outlined. Extension of the methods to account for the effects of extant multiple faults is indicated.

Shin, K. G.↗

Reliability of solid rocket motor cases and nozzles

A recent article in Aerospace America claims that 'the average success ratio of the current U.S. stable of launch vehicles, including upper stages, is about 92 percent (without upper stages it is close to 95 percent). The 8 percent failure probability implies an expected loss of $12M per flight, not including the lost opportunity costs'. Since payload costs are likely to be much greater than launch costs and even more so for the new launch vehicles for the Advanced Launch Development Program (ALDP), the cost of rocket motor unreliability at the current 8 percent rate can run into billions of dollars if expected increases in demand are realized. At an 8 percent failure rate, it is extremely unlikely that failure will occur during the first few ground tests of a new system. At that time, most of the design, analysis and tooling costs of the program have not expended. Since most systems are expected to be used ten to a hundred or more times, the likelihood of one or more failures is very large, and it can be expected that the above losses will be realized in the future. This will occur unless the problems are addressed and remedied. Recent trends suggest the problem is not being addressed adequately.

Crose, James G.↗

Providing Data Access and Analysis Capabilities to SERVIR’s Data-Sparse Regions

In developing regions of the world, the communications infrastructure pose enormous challenges for using Earth observation data. Limited internet bandwidth along with the high costs make it almost impossible to process and extract zonal statistics over large periods of time for even small geographic areas. In such cases, downloading daily rainfall data or dekadal series of NDVI data would take days and consume all the bandwidth allocated to an organization (for reference, internet connections in Niger would cost thousands of dollars per month at a maximum - and unreliable - bandwidth of just 10 Mbps). Running crop models or hydrological models typically require several years of historic data over the area of interest (AOI). In some cases, these AOIs are relatively small compared to the footprint of individual earth observation granules. Hence, systems that let the stakeholders subset the data to download to a user specified area, or even submit processing requests that let them download small result files for the AOI become critical. The SERVIR program has developed a tool to provide this type of access to help decision makers in developing regions use long time series of adjusted rainfall data (CHIRPS), NDVI values, seasonal weather forecasts, evaporative stress indices and others in a very efficient manner. This system, named ClimateSERV (https://climateserv.servirglobal.net) ingests the datasets in an automated fashion and allows interactive access (through a web application), or automated access through a simple API that developers can quickly incorporate in independent applications. This way, the extraction of daily averages of rainfall over a 50 square Km area through 30 years of archived data takes only a few seconds to process, and the results can be presented on an online chart or downloaded in a comma separated file that's only a few Kb.

Ashmall, William↗

SYSTEMATIC BIASES IN THE OBSERVED DISTRIBUTION OF KUIPER BELT OBJECT ORBITS

The orbital distribution of Kuiper Belt objects (KBOs) provides important tests of solar system evolution models. However, our understanding of this orbital distribution can be affected by many observational biases. An important but difficult to quantify bias results from tracking selection effects; KBOs are recovered or lost depending on assumptions made about their orbital elements when fitting the initial (short) observational arc. Quantitatively studying the effects and significance of this bias is generally difficult, because only the objects where the assumptions were correct are recovered and thus available to study 'the problem', and because different observers use different assumptions and methods. We have used a sample of 38 KBOs that were discovered and tracked, bias-free, as part of the Canada-France Ecliptic Plane Survey to evaluate the potential for losing objects based on the two most common orbit and ephemeris prediction sources: the Minor Planet Center (MPC) and the Bernstein and Khushalani (BK) orbit fitting code. In both cases, we use early discovery and recovery astrometric measurements of the objects to generate ephemeris predictions that we then compare to later positional measurements; objects that have large differences between the predicted and actual positions would be unlikely to be recovered and are thus considered 'lost'. We find systematic differences in the orbit distributions which would result from using the two orbit-fitting procedures. In our sample, the MPC-derived orbit solutions lost slightly fewer objects (five out of 38) due to large ephemeris errors at one year recovery, but the objects which were lost belonged to more 'unusual' orbits such as scattering disk objects or objects with semimajor axes interior to the 3:2 resonance. Using the BK code, more objects (seven out of 38) would have been lost due to ephemeris errors, but the lost objects came from a range of orbital regions, primarily the classical belt region. We also compare the accuracy of orbits calculated from one year arcs against orbits calculated from multiple years of observations and find that two-opposition orbits without additional observations acquired at least two months from opposition are unreliable for dynamical modeling.

79 ASTRONOMY AND ASTROPHYSICS↗

Several Small or Single Large? Quantifying the Catchment-Wide Performance of On-Site Wastewater Treatment Plants with Inaccurate Sensors

On-site wastewater treatment plants (OSTs) often lack monitoring, resulting in unreliable treatment performance. They thus appear to be a stopgap solution despite their potential contribution to circular water management. Low-maintenance but inaccurate soft sensors are emerging that address this concern. However, how their inaccuracy impacts the catchment-wide treatment performance of a system of many OSTs has not been quantified. Here, we develop a stochastic model to estimate catchment-wide OST performances with a Monte Carlo simulation. In our study, soft sensors with a 70% accuracy improved the treatment performance from 66% of the time functional to 98%. Soft sensors optimized for specificity, indicating the true negative rate, improve the system performance, while sensors optimized for sensitivity, indicating the true positive rate, quantify the treatment performance more accurately. This new insight leads us to suggest programming two soft sensors in practical settings with the same hardware sensor data as input: one soft sensor geared to high specificity for maintenance scheduling and one geared to high sensitivity for performance quantification. Our findings suggest that a maintenance strategy combining inaccurate sensors with appropriate alarm management can vastly improve the mean catchment-wide treatment performance of a system of OSTs.

54 ENVIRONMENTAL SCIENCES↗

Response to "The Iris Hypothesis: A Negative or Positive Cloud Feedback?"

Based on radiance measurements of Japan's Geostationary Meteorological Satellite, Lindzen et al. found that the high-level cloud cover averaged over the tropical western Pacific decreases with increasing sea surface temperature. They further found that the response of high-level clouds to the sea surface temperature had an effect of reducing the magnitude of climate change, which is referred as a negative climate feedback. Lin et al. reassessed the results found by Lindzen et al. by analyzing the radiation and clouds derived from the Tropical Rainfall Measuring Mission Clouds and the Earth's Radiant Energy System measurements. They found a weak positive feedback between high-level clouds and the surface temperature. We have found that the approach taken by Lin et al. to estimating the albedo and the outgoing longwave radiation is incorrect and that the inferred climate sensitivity is unreliable.

Chou, Ming-Dah↗

The BiDFET Device and Its Impact on Converters

The matrix converter topology for direct ac-to-ac conversion offers elimination of the bulky and unreliable D.C. link capacitors used in the popular Voltage-Source Inverter (VSI) with a front-end rectifier. The resulting more compact and higher efficiency implementation is a desirable solution for a wide variety of applications, such as photovoltaic energy generation, motor drives, and energy storage systems. The development of matrix converters has been hampered by the lack of availability of commercial bidirectional power switches with the ability to block high voltages in the first and third quadrants, carry on state current in both quadrants with low voltage drop, exhibit large forward-biased safe-operating-area (FBSOA), and low switching power losses. Consequently, many implementations have been tried in the past using discrete devices, as listed in Table I. Two implementations utilize commonly available asymmetric blocking IGBTs, while two cases make use of SiC power MOSFETs. They generally have a large parts count (4-6 individual switches) that occupies significant space in the converter where multiple bi-directional switches are required. They also have a high on-state voltage drop that degrades efficiency. As a result, one implementation utilizes symmetric blocking IGBT to achieve a low parts count (2), but its switching losses are unacceptably high.

42 ENGINEERING↗

Standard methods for heat capacity measurements on a Quantum Design Physical Property Measurement System

The commercial availability of the Physical Property Measurement System (PPMS) by Quantum Design has significantly increased access to heat capacity measurements on a wide variety of materials. Although the PPMS can routinely measure the heat capacities of thermally conducting materials with high accuracy, specialized sample mounting techniques must be used for insulating powders, and the analysis of first order transitions also requires non-standard methods. The concern is that many users are not aware of these constraints when measuring the heat capacity of a diverse array of materials, and therefore, the heat capacity data reported in the literature can be unreliable. In this paper, we provide an extensive and critical review of the heat capacity data reported in the literature measured using the Quantum Design PPMS. The purpose is to provide a de facto standard for sample mounting and data analysis methods suitable for the reporting of accurate thermodynamic data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Report on Data Quality Required for Modeling an MSR

Calculations were performed to assess how uncertainties in molten salt property values impact the results of behavior models of molten salt reactor systems under steady-state conditions. The thermophysical and thermochemical properties of salt mixtures being considered for use in molten salt reactors are not yet well characterized and methods used to measure property values to molten salts are not yet well established. The limited property data for salts of interest that are available in the literature are inconsistent and unreliable. Many methods used to measure property values remain developmental in the sense that not all variables affecting measured values have been identified or controlled during the measurement and not all aspects of the measurements affecting data quality are calibrated. A prior report described the repeatability of measurements made at Argonne and the reproducibility of measurements made with the same salts at several institutions is being evaluated. There is significant uncertainty in measured property values due to instrumental limitations and the effects of contaminants in the salts used to make the measurements that impacts predictions of salt behavior in a reactor. Most salts of interest are multicomponent eutectic or near-eutectic mixtures and both uncertainty in the salt composition and uncertainty in measured values. Furthermore, the salt composition evolves over time due to the uptake of impurities from the atmosphere and corrosion of containment vessels. More significantly, fission products will accumulate during operation that change the salt compositions and property values. MSR developers need to understand how this uncertainty in the basic property data of the fuel will impact modeling predictions for normal reactor operation as well was in transient scenarios that will impact the safety basis. The calculations and analyses in this report address the impact of uncertainty in measured property values under steady-state conditions through a generalized parametric study. The pooled uncertainty from contributions by a number of factors were considered and quantified, including varying composition due to impurities and fission products, imprecision in the measured values, and uncontrolled aspects of the measurement. In this way, we can begin to gain an understanding of the magnitude of the impact uncertainty will have in modeling MSR systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ActiveBAS: A Low-cost, Scalable Control Solution for Grid-Interactive Small and Medium Sized Commercial Buildings

This project aims to develop and enhance a low-cost, highly scalable control solution for Small and Medium-Sized Commercial Buildings (SMCB), assess the business potential at multiple sites, and perform commercialization efforts. The technology can be applied to any buildings served by multiple units, with the benefits being greatest for open-spaced buildings, such as banks, retail stores, restaurants, and factories. This project aims to develop an affordable control solution for: 1) SMCB grid responsiveness, 2) reduction of GHG by changing unit operations, 3) greater reduction in utility costs, and 4) rapid adoption in the marketplace. The proposed technology will be built on a previously developed and demonstrated MPC solution. The minimal sensor requirement and less need of control expertise are the unique feature of the algorithm that leads to low capital and maintenance costs, and short installation and implementation time. These attributes contribute to low capital and maintenance costs, as well as a short installation and implementation time. However, these advantages come with a trade-off: increased difficulties and unreliability when applying traditional modeling and MPC control approaches due to limited information. This final report describes the modeling approaches developed and tested to overcome these challenges. It begins by outlining the modeling challenge posed by minimal sensor requirements, then delves into the proposed modeling approaches, which primarily involve system identification. Finally, preliminary test results for a simulation case study are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗