Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Thermodynamic Analysis of Thermo-vacuum Clothes Drying Operation

Clothes drying accounts for a significant amount of energy consumed in residential and commercial sectors. A thermal vacuum clothes drying technology (TVCD) is proposed as an advanced clothes dryer which can significantly reduce the energy requirements by expediting the drying process. In the conventional convective clothes dryer, hot dry air is introduced into the drum which gets in direct contact to dry the clothes. This process is energy inefficient since the significant amount of heat and the water carried out with the exhaust stream are wasted. In contrast to the conventional convective drying technique, the drying mechanism of TVCD is through nucleate boiling at low temperature due to reduced vessel pressure. The process is not only efficient but also reduces the required time for drying. The objective of this paper is to develop a comprehensive thermodynamic model to predict the transient drying process of TVCD. The three-stage system model including the detail analysis of individual components is capable of simulating the variation of the water content in the textile under various operational conditions. The preliminary results show that the drying time of 3 lb textile from 70% to 2.5% in TVCD is approximately four times less than the time required in the conventional clothes dryer. Parametric studies are carried out to understand the effect of operation conditions and component geometry on the system performance. Energy consumption of the system is also analyzed.

Yang, Cheng-Min↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Certifying the Performance of Fixative Technologies under Open Air Demolition Activities for D and D - 20096

Department of Energy (DOE) facilities undergoing deactivation and decommissioning (D and D) activities struggle with safety concerns of residual radioactive contamination leftover after gross decontamination efforts have concluded. The positive effects of implementing fixative technologies for decommissioning and maintenance is known across the DOE complex. However, there is no standardized metric in place that quantifies the performance of these technologies such as incombustible fixative platforms that immobilize the contamination in a solid polymer material under normal operating conditions or when exposed to stressors. The primary focus of this research is to provide the empirical data necessary to properly characterize the effects of implementing fixative technologies on mitigating the release of contamination. In addition, this effort has been used to identify and establish uniform testing protocols to quantify operational parameters of fixating platforms and properly credit such systems under a variety of operational conditions and stressors that can arise during open air demolition efforts (e.g. impact, water, thermal, etc.). The established protocols will be provided to the ASTM International E10.03 Subcommittee on Radiological Protection for Decontamination and Decommissioning of Nuclear Facilities and Components for the potential of formal standardization. Attributes to be addressed during testing are material compromise from impact stress, thermal stress for incombustible fixative materials, and immobilization factors (how well an immobilizing platform is capable of retaining fixated material during thermal and impact stressors). In developing these test methods, a greater understanding of the material's behavior under anticipated and unanticipated events, such as decommissioning activities and contingency events as outlined in the Basis of Interim Operations (BIO), can be successfully characterized. There are several key components of the experimental methodology that is essential in empirically certifying fixative technologies. A surrogate contaminant with a unique signature has been utilized with the implementation of a uniform contamination process of test coupons that is quantifiable and replicable for direct fixative comparisons. A modular test chamber has also been used to apply the various stressors of interest. Collection of released contamination that includes airborne and resettled contaminant particles and analyzed using mass spectrometry. This research directly supports DOE complex-wide concerns in terms of final disposition of nuclear facilities and the considerations made during their time between ceasing facility operation and final disposition. The results of this effort aims to provide a standardized road map and logical decision flow to better facilitate fixative technologies into D and D activities required to achieve the desired facility end state. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a coupled experimental–computational approach for engineering optimization of spout-fluidized bed particle coating systems

The design of spout-fluidized bed (SFB) coating systems for nuclear particle fuels typically relies on trial-and-error processes, comprising iterative and time-consuming coating deposition experiments and post-deposition characterization. At an engineering scale, this approach to guided SFB system design is inefficient, highlighting the need for streamlined experimental methodologies which can correlate fluidization conditions to downstream coating outcomes. In this study, we combine time-resolved particle image velocimetry (PIV) with CFD–DEM simulations to benchmark hydrodynamic behavior in a 3D spout-fluidized bed. By exploiting easily accessible optical measurements of particle motion at the bed wall and within the spouting region, we obtain quantitative velocity fields that can be directly compared with model predictions of the occluded bed region, without resorting to complex imaging and characterization techniques such as X-ray or magnetic resonance tomography. Experimental benchmarking reveals strong agreement between CFD–DEM and PIV in the spout and annulus regions, while discrepancies near the wall highlight areas for future model development. Here, the proposed integrated experimental–numerical framework will enable a direct connection between measured variables and numerically predicted fluidization performance of dense, surrogate nuclear particle fuel feedstock such that experimental SFB component design can be rapidly evaluated, informing design decisions for nozzle geometry and operating conditions. Future work will extend this framework by correlating quantified fluidization metrics across nozzle geometries and operating conditions with the resulting coating morphology, microstructure, and uniformity. Establishing these correlations will enable predictive links between hydrodynamic performance and coating quality, providing a rational, scalable basis for optimizing SFB design prior to coating deposition.

CFD/DEM↗

EV Profile Capture

NextGen Profiles' EV profile capture efforts aimed to explore the variance in performance and evaluate how different operational conditions influence production EV charging behavior. Data were collected at a frequency of 10 Hz from both the EV and EVSE during each charge session. These charge session parameters were then entered into a time-series database for further analysis. The data were gathered under different operational conditions to examine the effects of various factors such as battery state of charge, battery temperature, vehicle condition, smart charge management, and EVSE limitations. The EV profile capture dataset includes extensive high-power charging data from 16 different EVs—comprising light-, medium-, and heavy-duty vehicles—along with EVSE from various suppliers. To protect confidentiality, the EV and EVSE metadata are anonymized, and the publicly released datasets are aggregated to 0.1-Hz frequency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Self-Organizing Nano Grid (SONG) for Energy Access Clusters

In this paper, a bottom-up dc Self-Organizing Nano Grid (SONG) for rural electrification at ultra-low-cost through a flexible and scalable topology is presented. The proposed nano grid requires no communication and uses dc-bus signaling to convey excess energy in the system through the bus voltage, allowing independent agents to conduct energy transactions based on their needs in a decentralized manner. Moreover, this article proposes a concept that uses a novel multi-source, multi-segment droop control strategy with demand coordination, allowing for dynamic self-balancing of the system under fluctuating operating conditions. The unique use of a surplus photovoltaic (PV) power droop mode precisely estimates energy availability to minimize load chattering that helps in stabilizing the dc-bus. In addition, this architecture uses standard dc/dc converters for a low-cost, modular, Plug and Play ( PnP ) solution with highly automated operation, enabling local assembly, operation, and maintenance by non-technical personnel. The proposed SONG concept was validated in simulation and with a 700W, laboratory-scale, custom made nano grid system. The simulation and experimental test cases show the feasibility of the SONG system by demonstrating the proposed multi-source, multi-segment droop control strategy without load chattering under varying operating conditions.

dc-dc converter↗

In-device Battery Failure Analysis

Lithium-ion batteries are indispensable power sources for a wide range of modern electronic devices. However, battery lifespan remains a critical limitation, directly affecting the sustainability and user experience. Conventional battery failure analysis in controlled lab settings may not capture the complex interactions and environmental factors encountered in real-world, in-device operating conditions. Here, this study analyzes the failure of commercial wireless earbud batteries as a model system within their intended usage context. Through multiscale and multimodal characterizations, the degradations from the material level to the device level are correlated, elucidating a failure pattern that is closely tied to the specific device configuration and operating conditions. The findings indicate that the ultimate failure mode is determined by the interplay of battery materials, cell structural design, and the in-device microenvironment, such as temperature gradients and their fluctuations. This holistic, in-device perspective on environmental influences provides critical insights for battery integration design, enhancing the reliability of modern electronics.

36 MATERIALS SCIENCE↗

Gaining Insights in Loading Events for Wind Turbine Drivetrain Prognostics

Wind energy is one of the largest sources of renewable energy in the world. To further reduce the operations and maintenance (O&M) costs of wind farms, it is essential to be able to accurately pinpoint the root causes of different failure modes of interest. An example of such a failure mode that is not yet fully understood is white etching cracks (WEC). This can cause the bearing lifetime to be reduced to 5–10% of its design value. Multiple hypotheses are available in literature concerning its cause. To be able to validate or disprove these hypotheses, it is essential to have historic high-frequency measurement data (e.g., load and vibration levels) available. In time, this will allow linking to the history of the turbine operating data with failure data. This paper discusses the dynamic loading on the turbine during certain events (e.g., emergency stops, run-ups, and during normal operating conditions). By combining the number of specific events that each turbine has seen with the severity of each event, it becomes possible to assess which turbines are most likely to show signs of damage.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Imaging Power Losses in CdSeTe Solar Cells

Much of the research on CdSeTe photovoltaics is focused on improving the open-circuit voltage (V oc ) of the solar cell. But solar cells operate at the maximum power point (MPP) rather than at V oc . The recombination processes at MPP may be different than those at V oc , and increasing the power output at MPP is the key to advancing efficiency. Here, we introduce a camera-based PL imaging system that enables power loss analysis under operating conditions and across cm-sized areas covering multiple cells. The instrument is demonstrated with CdSeTe devices having efficiencies greater than 19%. An implied current density versus implied voltage (iJV) curve can be produced at each pixel with <20 µm resolution. We find that regions with high implied open circuit voltage are often those with low implied fill factor, showing that voltage loss analysis at open circuit is not sufficient to understand power losses under operating conditions. Measurement of JV curves as a function of irradiance can also be performed in the system, which allows series resistance-free pseudo JV (pJV) curves to be produced. Comparison of pJV to measured JV and iJV curves allows further analysis of the operational losses, pointing the way to higher efficiency.

14 SOLAR ENERGY↗

Advanced sorbents for modular oxygen production for REMS gasifiers

Under a DOE funded effort, Thermosolv LLC has been developing a sorbent-based oxygen production technology for gasification and oxy-combustion applications. The sorbents utilize oxygen-storage properties of certain perovskites to (1) selectively adsorb oxygen at moderate temperature from compressed air and (2) release the adsorbed oxygen into a vacuum or a sweep gas such as CO2 and/or steam. Through cyclic operations of multiple sorbent beds such a process can be made continuous. Pressure drop across the sorbent bed and other similar design considerations dictate that the sorbent be in the form of a high surface-area-to-volume pellet and yet still possess sufficient crush strength and integrity. Process efficiency is determined by the sorption and desorption kinetics and sorbent capacity. Typical process involves cycle times in the order of 100 seconds, a time too short to fully utilize the full volume of the sorbent and the sorption capacity of the sorbent pellets. As a part of this project, Thermosolv LLC undertook the development of oxygen sorbents as a high-surface area supported sorbent on a light-weight inert support to (1) reduce the cost, (2) increase the productivity, and (3) reduce the overall weight of the reactor. Using a previously developed perovskite (LSCF 1991) with its well-characterized performance, composite sorbent pellets each consisting of an inert core coated by a thin layer of the functional perovskite material were produced. Several low-density, inexpensive inert solids supports in the 1/8”-1/4” size were selected to keep the pressure drop across the sorbent bed in the acceptable range. A number of commercial technologies including spray coating, dip coating, incipient impregnation of porous substrate followed by thermal annealing at various temperatures and duration were employed and tested to produce robust composite supported sorbent pellets. A sense of optimum coating thickness was developed by testing sorbent pellets of various increasing diameter pellets. LSCF-1991extrudates ranging in size from 1/32” to 3/16” were tested in a TGA and in a fixed-bed pressure swing test set-up for sorption/desorption cycles of interest. The data show that for the operational conditions of interest the coating thickness for a supported sorbent pellet needs to be approximately 1/32” (about 0.8 mm). Subsequent work thereby concentrated on developing composite pellets of various substrates, shapes and sizes with coating layer of about this size range. Candidate support materials were chosen based on cost, inertness, mechanical strength, thermal expansion and chemical stability with sorbent material, and in a size range to give an acceptable pressure drop in fixed-bad reactor configurations. Coating application methods used for application of the sorbent onto the support included precipitation, spray coating and dip coating from sorbent slurries and sol gels. For all coated supports where we could successfully apply a uniform coating of desired thickness with an acceptable handling performance in terms of exfoliation, TGA-based cyclic sorption/desorption testing was performed to determine cycling capacity of oxygen. Among nearly twenty different support materials tested, best adhesion performance was obtained from stainless saddle supports. In the bench-scale fixed-bad tests stainless steel saddle support composite pellets with a coating thickness in the 0.6 mm or so range, the composite sorbent pellet performance approached up to 95% of that of the 2 mm parent material pellets. In a parallel approach to reducing the cost of the sorbent, alternate sorbent formulations replacing/reducing the amount of cobalt in the LSCF family were also investigated. Successful formulations that could match the performance of LSCF 1991 were identified based on TGA cyclic tests as LSCF 1919 and LSF 1910. In the range of operational envelop of cycle times and other relevant process operating conditions, the reduced Co formulations showed comparable performance in the bench-scale fixed-bad cyclic operations. As a part of this project, we also attempted substitution of La and Sr with Ca and Ba, and Co with Mn, Ni and Cu with little success, but the overall project goal of reducing sorbent cost in terms of raw material and manufacturing expenses was successful.

01 COAL, LIGNITE, AND PEAT↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single Primary Heat Extraction and Removal Emulator (SPHERE) Power Transient Testing

For heat pipe cooled microreactor development, it is essential to understand the characteristics of heat pipes and how they function under a wide range of operating conditions. Modeling the startup and shutdown of heat pipe cooled microreactors has been a major challenge for the modeling code. Validating these parameters within the code is key for the development and licensing of heat pipe cooled microreactor designs. Idaho National Laboratory (INL) has completed testing on power transients of a heat pipe with a range of operating conditions. The resulting temperature profiles from this testing can be utilized to aid in the validation of the startup and shutdown portions of the heat pipe modeling code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of Numerical Models of the Offshore Wind Turbine From the Alpha Ventus Wind Farm Against Full-Scale Measurements Within OC5 Phase III

The main objective of the Offshore Code Comparison Collaboration Continuation, with Correlation (OC5) project is validation of aero-hydro-servo-elastic simulation tools for offshore wind turbines (OWTs) through comparison of simulated results to the response data of physical systems. Phase III of the OC5 project validates OWT models against the measurements recorded on a Senvion 5M wind turbine supported by the OWEC Quattropod from the alpha ventus offshore wind farm. The following operating conditions of the wind turbine were chosen for the validation: (1) idling below the cut-in wind speed, (2) rotor-nacelle assembly (RNA) rotation maneuver below the cut-in wind speed, (3) power production below and above the rated wind speed, and (4) shutdown. A number of validation load cases were defined based on these operating conditions. The following measurements were used for validation: (1) strains and accelerations recorded on the support structure and (2) pitch, yaw, and azimuth angles, generator speed, and electrical power recorded from the RNA. Strains were not directly available from the majority of the OWT simulation tools; therefore, strains were calculated based on out-of-plane bending moments, axial forces, and cross-sectional properties of the structural members. The simulation results and measurements were compared in terms of time series, discrete Fourier transforms, power spectral densities, and probability density functions of strains and accelerometers. A good match was achieved between the measurements and models setup by OC5 Phase III participants.

17 WIND ENERGY↗

Energy efficiency in industrial drying: A hybrid ultrasonic system with a novel dynamic optimization framework

Drying processes are among the most energy-consuming operations in industrial and manufacturing settings, demanding strategic selection, design, and control for enhanced efficiency. Advancing drying technologies is critical for improving sustainability, lowering energy use, reducing carbon emissions, and minimizing waste. This study explores two innovative strategies aimed at transforming drying processes into sustainable, low-carbon systems by reducing energy consumption, minimizing waste, and maintaining a strong emphasis on preserving product quality. The first strategy showcases a sub-pilot scale hybrid ultrasonic-convective dryer for agrifood products. This technology, powered by electricity (process electrification), integrates non-thermal ultrasonic dehydration with convective heating and is presented as a sustainable and energy-efficient solution that enhances eco-friendly practices. The second strategy involves introducing and implementing a novel, multiobjective, mixed integer dynamic optimization technique to determine the optimal time-dependent process parameter values for the drying operation. This optimization technique yields operating conditions that are piecewise constant in time aiming to maximize the energy efficiency of the hybrid ultrasonic-convective dryer while ensuring strict adherence to product quality constraints. By adopting the hybrid ultrasonic-convective dryer, a notable 35% improvement in energy efficiency was achieved compared to conventional hot-air drying systems for drying apple slices. The proposed optimization framework further enhanced energy efficiency by nearly 14% over the most efficient process on the identical testbed, under static operating conditions. The reported enhancements have been experimentally validated. Regarding drying time (thereby improving production yield), the developed hybrid ultrasonic-convective dryer demonstrates as much as a 41% reduction in total processing time, which is further optimized by an additional 10% using our proposed optimization framework. The research outcomes have profound implications for the design and operation of drying systems, encompassing crucial aspects such as process electrification, cost-effectiveness, energy savings, time efficiency, product yield, product quality, and process automation.

Dynamic optimization↗

Assessment of Near-Term Fuel Screening and Qualification Needs for Nuclear Thermal Propulsion Systems

Nuclear thermal propulsion (NTP) is an in-space propulsion technology capable of both high specific impulse (850–1000 s) and thrust (44–1112 kN), which can help reduce trip times for crewed missions beyond low Earth orbit. NTP technology has been demonstrated during historic programs. Over 20 ground test reactor experiments were performed, which demonstrated the prototypic reactor operations, during the Nuclear Engine for Rocket Vehicle Application (NERVA)/Rover program (1955–1972). Although historical programs have shown that NTP is a viable in-space propulsion technology, developing NTP in modern programs is contingent on the development and qualification of ultrahigh-temperature nuclear fuel technologies that can withstand engine operating conditions. In historical NTP development programs such as NERVA/Rover, prototypic reactor/engine schemes were ground tested to assess the overall system feasibility and to qualify the reactor fuel forms for eventual flight systems. Although this approach is effective to verify fuel performance under prototypic conditions, relying solely on full-scale NTP reactor tests as the pathway for verifying or qualifying fuel is inefficient and cost prohibitive today. Additionally, modern nuclear licensing requirements state that before test reactor approval, reactor components and fuel elements should be qualified via non-nuclear (out-of-pile) and nuclear (in-pile) testing under representative operating conditions. Using this methodology, fuel matures as production scale fabrication methods are established, and as produced fuel performance is demonstrated. Here, this paper provides an overview of historical approaches to NTP fuel performance maturation, including fuel screening and qualification needs, and provides insight for establishing an efficient testing paradigm that can be implemented to rapidly and affordably develop NTP fuel forms for eventual qualification.

42 ENGINEERING↗

CFD modeling of crystallization fouling with CO 2 desorption incorporated for a falling-film evaporator in thermal desalination

Seawater flowing around horizontal tubes in falling-film evaporators is a common configuration for thermal desalination. Heat is transferred from in-tube steam condensation to the shell-side seawater by conduction through the tube wall and scaling layer, and conduction and convection to the evaporating liquid film. CO 2 is simultaneously released from seawater and mixed with the produced vapor. Fouling coupled with CO 2 desorption has deleterious impacts on both evaporation and condensation. The evaluation of spatiotemporal dependent crystallization fouling and CO 2 desorption is vital to selecting optimal operating conditions. Here, in this work, a CO 2 desorption model is integrated into CFD modeling for predictions of coupled heat and mass transfer, to understand and predict scale formation and CO 2 desorption with local and transient profiles of temperature, carbonate species concentrations, pH, and total alkalinity. The porosity of the scale layer is experimentally determined as 67.7% and invoked in the calculation of effective thermal conductivity. The simulation results reveal that high steam temperatures increase seawater total alkalinity and accelerate scale formation. The scale thickness on the bottom tube reaches 0.30 μm and 5.24 μm for steam temperatures of 60 °C and 80 °C, respectively. High salinity leads to a large CO 2 desorption rates. The CO 2 desorption rate increases 43% when the seawater salinity increases from 35 to 55 g/kg. The effects of operating conditions on carbonate speciation and pH have been compared and analyzed. This model can serve as a comprehensive tool for the design of thermal desalination systems and optimal operation.

42 ENGINEERING↗

Computationally Guided Design of Multiple Impurities Tolerant Cathode for Solid Oxide Fuel Cell Applications

Solid oxide fuel cells (SOFCs) have been recognized as promising candidates in the demand of reducing the dependence on fossil fuels, which is one of the solutions to the threat of global warming. It was reported that the direct chemical-to-electrical energy conversion in SOFCs comes with negligible emission of greenhouse gases and up to 60% working efficiency. SOFC has unique advantages over traditional power generation technologies and other types of fuel cells due to the use of relatively inexpensive materials, low sensitivity to poisoning impurities in fuels, relatively high conversion efficiency, and fuel flexibility (like carbon-based fuels). However, during the SOFC operation, the cathode is exposed to intrinsic and extrinsic airborne contaminants at high temperatures (600–900°C), leading to their reaction with electrode materials, irreversible chemical and structural changes, and electrochemical performance degradation. of which CO2, SO2, Cr6+ and H2O are known to be concerns. Thus, developing a comprehensive understanding of the multiple impurities poisoning of SOFC cathodes in the presence of single or multiple impurities is necessary to address the long-term degradation of the SOFC cathode systems at operating conditions. An integrated computational and experimental approach has been utilized in the current work aiming at the comprehensive investigation of the cathode materials under single or multiple impurities poisoning effects, understanding the multiple impurities poisoning mechanism(s), and improving the long-term durability of the SOFC cathodes to develop better performing impurity-tolerant cathode materials. We first examined the agreement between the simulation approach and the experimental observations at various atmospheric and temperature conditions to confirm the reliability of CALPHAD for poisoning simulations in these cathodes. Then, using this approach, we investigated the accelerated testing protocol, which has become the standard method for conducting impurity poisoning experiments involving these cathode materials. We found our simulation approach is able to predict in which systems, i.e., cathode material and treatment environment, the accelerated testing protocols reflect actual operating conditions. Finally, in-depth simulations were done for these three candidate cathodes under different experimental conditions and suggested directions toward alternative cathode materials that have superior impurity tolerance.

36 MATERIALS SCIENCE↗