Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Laboratory Atom Interferometer Instrument

We have demonstrated a laboratory based, high bandwidth atom interferometer instrument and have performed an incipient gravity measurement with a fractional statistical uncertainty of ag/g = 4.4 x 10 -6 where g is the acceleration due to gravity. We have designed, constructed, and optimised numerous laser systems for this purpose, most notably a powerful Raman laser (12 W at 780 nm) which will allow large momentum transfer and large detuning interferometry to be carried out at high bandwidth for the first time. This experiment is a general purpose test bed for exploring the fundamental limitations of atom interferometer techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of Atom Interferometer Accelerometer

This report presents the theoretical effort to model and simulate the atom-interferometer accelerometer operating in a highly mobile environment. Multitudes of non-idealities may occur in such a rapidly-changing environment with a large acceleration whose amplitude and direction both change quickly. We studied the undesired effect of high mobility in the atom-interferometer accelerator in a detailed model and a simulator. The undesired effects include the atom cloud's movement during Raman pulses, the Doppler effect due to the relative movement between the atom-cloud and the supporting platform, the finite atom cloud temperature, and the lateral movement of the atom cloud. We present the relevant feed-forward mitigation strategies for each identified non-ideality to neutralize the impact and obtain accurate acceleration measurements.

43 PARTICLE ACCELERATORS↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The MAGIS-100 Experiment and a Future, Kilometer-scale Atom Interferometer

The dearth of signals unambiguously attributable to WIMP dark matter motivates exploring new parameter space, particularly the ultra-light dark matter (ULDM) regime, where the signal is not scattering events but wave phenomena. The proliferation of quantum technologies has enabled searches for ULDM at previously inaccessible sensitivity. One such technology is atom interferometry which can measure time-dependent fluctuations in the energy spacing of atoms as well as in the light-travel time across the apparatus, enabling searches for ULDM and gravitational waves, respectively. In this talk, I will review the science case for long baseline atom interferometers, such as MAGIS-100 at Fermilab, provide an update on the experiment’s status, and discuss the need for a future, kilometer-scale atom interferometer which would achieve unprecedented sensitivity to ULDM and gravitational waves in the “Mid-Band” region between LIGO and LISA.

Temples, Dylan J. [Fermilab] (ORCID:00000001601725↗

Measurements of Martin-Puplett Interferometer Limitations using Blackbody Source

Frequency domain measurements with Martin-Puplett interferometer is one of a few techniques capable of bunch length measurements at the level of ~ 100 fs. As the bunch length becomes shorter, it is important to know and be able to measure the limitations of the instrument in terms of shortest measurable bunch length. In this paper we describe an experiment using a blackbody source with the modified Martin-Puplett interferometer that is routine- ly used for bunch length measurements at the JLab FEL, as a way to estimate the shortest, measurable bunch length. The limitation comes from high frequency cut-off of the wire-grid polarizer currently used and is estimated to be 50 fs RMS. The measurements are made with the same Golay cell detector that is used for beam measure- ments. We demonstrate that, even though the blackbody source is many orders of magnitude less bright than the coherent transition or synchrotron radiation, it can be used for the measurements and gives a very good signal to noise ratio in combination with lock-in detection. We also compare the measurements made in air and in vacuum to characterize the very strong effect of the atmospheric absorption.

43 PARTICLE ACCELERATORS↗

39 GHz Interferometer System for Measuring Detonation Velocity

A new 39 GHz RF interferometer system is presented for use in velocity measurements of high explosives (HE) detonations. The frequency was chosen to compliment the currently available suite, and provide more spatial information. An RF signal is generated and coupled to a waveguide adapter serving as an antenna. The HE is initially transparent to the RF. When the HE detonates, the detonation front becomes reflective to the RF. This reflection is picked up by the waveguide adapter and mixed with an unperturbed RF signal to give a low frequency signal which can be digitized with an oscilloscope. By comparing the signal with a reference signal, velocity information can be obtained using Fourier Transforms and wavelet models. Bench test results using a “slapper” are shown. The 39 GHz microwave interferometer is used in Deflagration to Detonation shots. The signal is reflected off a moving surface, and the Doppler shift of the reflected signal is used to calculate the velocity.

Ross, Patrick W.↗

The Laser Interferometer Space Antenna: Unveiling the Millihertz Gravitational Wave Sky

The first terrestrial gravitational wave interferometers have dramatically underscored the scientific value of observing the Universe through an entirely different window, and of folding this new channel of information with traditional astronomical data for a multimessenger view. The Laser Interferometer Space Antenna (LISA) will broaden the reach of gravitational wave astronomy by conducting the first survey of the millihertz gravitational wave sky, detecting tens of thousands of individual astrophysical sources ranging from white-dwarf binaries in our own galaxy to mergers of massive black holes at redshifts extending beyond the epoch of reionization. These observations will inform - and transform - our understanding of the end state of stellar evolution, massive black hole birth, and the co-evolution of galaxies and black holes through cosmic time. LISA also has the potential to detect gravitational wave emission from elusive astrophysical sources such as intermediate-mass black holes as well as exotic cosmological sources such as inflationary fields and cosmic string cusps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional second harmonic dispersion interferometer

An interferometer having a fundamental beam generator, a first second harmonic generator, a waveplate, a second second harmonic generator, a harmonic separator, and a polarizing beam splitter, mounted uniaxially, (i.e., the components are aligned along one optical axis), wherein the interferometer is adapted to change a diameter of a beam to match a diameter of a sample, and to change the diameter of the beam back to its original diameter.

Wessel, Frank Joseph↗

Multi-axis Accelerometry and Rotation Sensing using a Point Source Atom Interferometer

A point source atom interferometer (PSI) is a device where atoms are split and recombined by applying a temporal sequence of Raman pulses during the expansion of a cloud of cold atoms behaving approximately as a point source. Unlike a conventional light pulse atom interferometer, the PSI can produce a signal that corresponds to multi-axis rotation only, independent of acceleration. In addition, it can be used to measure acceleration along one direction, independent of rotation. Here, we describe a modified PSI that can be used to measure multi-axis rotation and multi-axis acceleration. Specifically, this type of PSI can be used to measure two-axes rotation around the directions perpendicular to the light pulses, as well as the acceleration in all three directions, with only one pair of Raman beams. Using two pairs of Raman beams in orthogonal directions sequentially, such a scheme would enable the realization of a complete atom interferometric inertial measurement unit.

Li, Jinyang↗

Detection of Terahertz Pulses Using a Modified Sagnac Interferometer

We describe a time resolved, interferometric method to detect terahertz (THz) pulses based on Sagnac geometry. A ZnTe electro-optic crystal is placed in one arm of the interferometer, and the THz-induced optical phase shift is demodulated by allowing the two arms to optically interfere. The theorital principle behind this new method is illustrated and a detailed comparison with the traditional electro-optic (EO) sampling technique used in THz time domain spectroscopy is performed. Key features of this new method are highlighted, serving as an aid to identify where this method may be useful in future applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Internal structure of laser supported detonation waves by two-wavelength Mach-Zehnder interferometer

Characteristics of the internal structure of the laser supported detonation (LSD) waves, such as the electron density n{sub e} and the electron temperature T{sub e} profiles behind the shock wave were measured using a two-wavelength Mach-Zehnder interferometer along with emission spectroscopy. A TEA CO{sub 2} laser with energy of 10 J/pulse produced explosive laser heating in atmospheric air. Results show that the peak values of n{sub e} and T{sub e} were, respectively, about 2 x 10{sup 24} m{sup -3} and 30 000 K, during the LSD regime. The temporal variation of the laser absorption coefficient profile estimated from the measured properties reveals that the laser energy was absorbed perfectly in a thin layer behind the shock wave during the LSD regime, as predicted by Raizer's LSD model. However, the absorption layer was much thinner than a plasma layer, the situation of which was not considered in Raizer's model. The measured n{sub e} at the shock front was not zero while the LSD was supported, which implies that the precursor electrons exist ahead of the shock wave.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On open electromagnetic resonators: relation between interferometers and resonators

The physical difference between the concepts 'Fabry-Perot interferometer' and 'open resonator' is discussed. It is shown that the use of the term 'Fabry-Perot resonator' for open laser resonators is incorrect both from the historical viewpoint and from the viewpoint of the physical meaning of the processes occurring in these resonators. (laser beams and resonators)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-chip Optical Filters with Designable Characteristics Based on an Interferometer with Embedded Silicon Photonic Structures

We demonstrate chip-scale flat-top filters at near-IR wavelengths using negative index photonic crystal based Mach-Zehnder interferometers. Supported by full three-dimensional numerical simulations, we experimentally demonstrate a new approach for engineering high-pass, low-pass, bandpass, and band-reject filters, based on designing the photonic band diagram both within the bandgap frequency region and away from it. We further show that our approach can be used to design filters that have tunable multilevel response for different sections of the spectrum and for different polarizations. This configuration enables deterministic control of the bandwidth and the rejection ratio of filters for integrated photonic circuits.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Polarisation non-reciprocity cancelling in Sagnac fibre ring interferometer: an attempt of realistic study

Polarisation non-reciprocity (PNR) of Sagnac fibre ring interferometer (FRI) is one the fundamental limits of its long term bias stability. PNR value, being huge initially, then was reduced strongly, but after that PNR problem was left far from PNR cancelling. The latter may be defined as PNR reducing up to 10{sup −10} deg/h when it does not prevent detecting the general relativistic Lense–Thirring effect. Clearly, such PNR cancelling may be treated only theoretically at this point. In this case, one has to model all practical defects of FRI. Present paper describes such kind of study for FRI of commercial fibre optic gyro implementing medium quality components. It is shown that for PNR cancelling, several meters fibre polariser is enough, despite of the stringent limitations of its standard polarisation extinction ratio. Also, a complete FRI configuration is treated for the first time in available literature, including an imperfect fibre coupler. This yields one more PNR component which is non-zero even for completely unpolarised light and which can be effectively suppressed by the fibre polariser too.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiwavelength erbium-doped fiber laser based on a polarization-dependent in-line Mach–Zehnder interferometer

A multiwavelength erbium-doped fiber laser based on a polarization-dependent in-line Mach–Zehnder Interferometer (in-line MZI) is proposed and experimental demonstrated. The polarization-dependent in-line MZI demonstrated is constructed by sandwiching a length of polarization maintaining fiber (PMF) between two abrupt fiber tapers fabricated in SMF. The proposed in-line MZI can work as a cost-effective all-fiber-based polarizer. In combination with the nonlinear polarization rotation technique, stable multiwavelength laser comb with uniform wavelength spacing is achieved at room temperature. The wavelength spacing is 0.8 nm. By properly tuning the PCs, the output laser combs with double and triple channel spacing can be also obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Waveform modelling for the Laser Interferometer Space Antenna

LISA, the Laser Interferometer Space Antenna, will usher in a new era in gravitational-wave astronomy. As the first anticipated space-based gravitational-wave detector, it will expand our view to the millihertz gravitational-wave sky, where a spectacular variety of interesting new sources abound: from millions of ultra-compact binaries in our Galaxy, to mergers of massive black holes at cosmological distances; from the early inspirals of stellar-mass black holes that will ultimately venture into the ground-based detectors’ view to the death spiral of compact objects into massive black holes, and many sources in between. Central to realising LISA’s discovery potential are waveform models, the theoretical and phenomenological predictions of the pattern of gravitational waves that these sources emit. This White Paper is presented on behalf of the Waveform Working Group for the LISA Consortium. It provides a review of the current state of waveform models for LISA sources, and describes the significant challenges that must yet be overcome.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon wave function formalism for analysis of Mach–Zehnder interferometer and sum-frequency generation

Biakynicki-Birula introduced a photon wave function similar to the matter wave function that satisfies the Schrödinger equation. Its second quantization form can be applied to investigate nonlinear optics at nearly full quantum level. In this paper, we applied the photon wave function formalism to analyze both linear optical processes in the well-known Mach–Zehnder interferometer and nonlinear optical processes for sum-frequency generation in dispersive and lossless medium. Results by photon wave function formalism agree with the well-established Maxwell treatments and existing experimental verifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗